1.
采用间接酶联免疫法,即用神经节苷脂包被,加入待检样品,再加入兔抗霍乱毒素B亚单位抗体,用标准样品的吸光值(A值)对标准样品的浓度绘制4-参数拟合曲线,根据标准曲线计算出待测样品中的CT浓度。结果显示,在浓度范围(0.6~16)ng/ml之间,CT标准浓度和检测浓度成线性关系,r2=0.9986。精确度在浓度范围(0.6~16)ng/ml,CT的平均回收率在96.24%~114.44%之间。精密度:批内变异CV%≤12.98%,批间变异CV%≤18.48%。特异性CT浓度在10ng/ml时,平均回收率为102.6%;CT浓度在5ng/ml时,平均回收率为111.17%;CT浓度在2.5ng/ml时,平均回收率为123.83%。实验表明该方法可检测霍乱疫苗原液中CT的含量。  相似文献   

2.
目的:用RP-HPLC方法对注射用重组人尿激酶原制剂蛋白含量进行定量分析。方法:用反相C18柱、0.1%TFA水溶液与0.1%乙腈进行梯度洗脱,280nm波长紫外检测器监测;以重组人尿激酶原同质标准品作为对照品,根据进样量和相应的峰面积建立标准曲线方程,将待测定样品的峰面积代入标准曲线方程,可测得蛋白含量。结果:按照方法学验证要求对此方法进行了专属性、检测限、定量限、线形、精密度(重复性、中间精密度)、准确度(回收率)考察,线性范围为9~27μg,回收率在97%以上,RSD2.0%,完全满足对制剂蛋白的定量需求。结论:本方法准确,适用于注射用重组人尿激酶原成品制剂蛋白定量测定。  相似文献   

3.
研究和建立一种基于酶标仪-96孔板高通量测定虫草酸含量的检测方法,并对该方法进行性能评价。以酶标仪为检测仪器,在96孔板内按照设定反应条件微量加入样品和试剂进行显色反应,利用酶标仪测定吸光度值并计算虫草酸含量。通过检测精密度、重复性、回收率,并与分光光度计法进行比较,综合评价该方法的准确度、精确度。结果表明,测定数据具有较高的精密度(样品CM1的RSD值0.829%;样品CM2的RSD值1.772%)、重复性(标准样品B40的RSD值2.061%;样品CM2 的RSD值1.599%)、回收率(平均回收率99.24%,RSD值3.666%),测定结果与分光光度法检测结果无显著差异(P>0.05)。结果表明,酶标仪微量法测定准确、重复性好,并可大大减少样品和试剂的用量,该方法方便、快捷、高效,可以替代分光光度法用于虫草酸含量的测定。  相似文献   

4.
目的甲胺磷的微生物高通量定量分析法,并在待检蔬菜样品进行初步的探索。方法以短双歧杆菌LJM-006作为测试菌,选择浓度为0、0.25、0.5、1.0、2.0和4.0 mg/L的甲胺磷标准品溶液20μL加入所述检测管内,37℃厌氧培养8~10 h,分别测定反应管和阴性对照反应管的A500值,B值为样品反应管的A500值,B0值为阴性对照反应管的A500值;以B/B0为纵坐标Y,甲胺磷浓度的对数值为横坐标X,绘制标准曲线,建立甲胺磷含量与B/B0的线性回归方程;以此方法进行模拟食品样品中所含甲胺磷检测,进行准确度、精密度分析。结果双歧杆菌菌株LJM-006对甲胺磷敏感性高,与其他有机磷农药的交叉反应率均小于2%;在0.01~100 mg/L浓度范围内B/B0与甲胺磷浓度对数值的线性关系良好,甲胺磷检测的标准曲线为Y=-24.68X+66.72,R2为0.9902,IC50=0.25 mg/L,检测下限达到0.1 mg/L,回收率为78.5%~105.7%,批内变异系数≤12%,批间变异系数≤8.2%。结论该方法具有操作简便,具备一定灵敏度和特异性等优点,可作为一种食品中甲胺磷残留筛检方法。  相似文献   

5.
目的:利用小鼠神经生长因子(mNGF)和纯化的兔抗mNGF IgG,建立mNGF直接竞争酶联免疫检测方法。方法:以亲和纯化兔抗mNGF IgG作为包被抗体,封闭、洗涤后加入用稀释液稀释的不同浓度的标准mNGF或样品液和生物素标记的mNGF混合液,于37℃孵育80 min或室温孵育120 min,洗涤后加入辣根过氧化物酶标记的链酶亲和素,洗涤后加入显色液显色,测定D450nm值,通过标准曲线计算待测样品中mNGF含量。结果与结论:建立了mNGF直接竞争酶联免疫检测方法;该方法的灵敏度约20 ng,变异系数为批内≤10%、批间≤15%,回收率为85%~115%;利用该方法检测了3批样品中mNGF的含量。  相似文献   

6.
目的采用双波长(492 nm/630 nm)微孔板赖氏法检测人血浆中丙氨酸氨基转移酶(alanine aminotransferase, ALT)的含量,并对该方法进行系统性的评价。方法按照ALT测定试剂盒的要求加样,应用双波长(492 nm/630 nm)微孔板赖氏法测定人血浆中的ALT含量,并对检测系统的专属性、线性范围、准确度和精密度进行验证。结果专属性分析结果显示,血浆样品与不同比例的抗凝剂混合,其中的ALT均能有效被检出,回收率分别为100%、95%和90%;对28和150个单位丙酮酸钠标准溶液进行倍比稀释5个梯度以制作标准曲线,采用多项式对标准曲线进行拟合,结果显示丙酮酸钠标准溶液分别在9.375~150、1.75~28和1.75~150个单位范围内线性关系均良好,相关系数r均达到0.99以上;准确度检测结果显示,已知含量的厂家质控血清和国家能力验证样品的实测值和理论值相比,回收率均在90%~110%之间;同一样品,重复加样18孔,重复性检测结果变异系数(CV)为5.29%;两位试验人员在不同日期对同一样品重复测定6次,中间精密度检测结果变异系数为5.49%。结论该检测方法专属性强、检测结果稳定可靠、线性良好、重复性好、检测通量大,可以有效降低成本,提高工作效率,适用于大规模检测人血浆中ALT的含量。  相似文献   

7.
对金针菇中棒曲霉素的分析检测方法进行了研究,旨在建立一种以液-液萃取为前处理方法,采用高效液相色谱(HPLC)分析检测金针菇中棒曲霉素含量的方法。主要研究结果如下:通过组织破碎,制备金针菇汁,采用乙酸乙酯重复萃取,用碳酸钠溶液净化萃取液,制备金针菇供试品。该方法处理和测定棒曲霉素精密度高,检出限低。棒曲霉素标准品的标准曲线为y=112.8x-14.23,R2=0.998 4,标准曲线范围为0.01~25μg/m L。  相似文献   

8.
目的建立肠道病毒71型(EV71)抗原ELISA定量检测方法,用于EV71疫苗生产工艺中抗原定量检测。方法选取抗EV71单克隆抗体作为包被抗体,HRP标记抗EV71多克隆抗体作为酶标二抗,建立EV71抗原ELISA定量检测方法。该方法经系统验证后,应用于定量检测2BS及Vero细胞基质EV71疫苗生产工艺过程样品的抗原含量。结果验证结果显示,该方法的线性范围为3.125~50.000 U/m L,样品回收率为92.0%~110.0%,变异系数小于8.8%;孵育时间及温度在一定范围内偏差的样品回收率为100.8%~113.8%;检测其他肠道病毒中抗原其A值均小于cut-off值;试剂于37℃孵育3 d后的检测样品回收率为101.4%~112.4%;2BS及Vero细胞基质EV71疫苗生产工艺过程样品的适用性检测中,抗原回收率为92.1%~114.9%。结论建立并验证EV71抗原ELISA定量检测方法,其准确度、精密度、耐用性均优良,特异性强、稳定性好,适用于不同细胞基质的EV71疫苗及多价手足口病疫苗生产工艺过程的质量控制。  相似文献   

9.
紫外分光光度法测定珍珠菜中总黄酮含量   总被引:10,自引:0,他引:10  
目的:建立珍珠菜提取液中总黄酮的含量测定方法。方法:采用紫外分光光度法,通过紫外可见扫描确定最大吸收波长,以芦丁为对照品制定标准曲线,并进行样品溶液稳定性试验和方法回收率与精密度试验。结果:最大吸收波长为405 nm,标准曲线线性范围为4.014-32.112μg/mL,r=0.999 9。样品液经A l3 络合后在0.5-2.5h内稳定性较好,平均加样回收率为102.00%±1.64%,RSD为1.61%,日内、日间精密度RSD小于2%,符合要求。结论:该方法简单方便、准确可靠,可以用来测定珍珠菜中总黄酮的含量。  相似文献   

10.
目的 建立C1酯酶抑制剂(C1 esterase inhibitor, C1-INH)抗原含量的双抗体夹心ELISA检测方法,验证后用于C1-INH纯化工艺摸索。方法 用羊抗人C1-INH抗体作为捕获抗体,用过氧化物酶(HRP)标记的羊抗人C1-INH抗体作为检测抗体,进行棋盘滴定初步确定捕获抗体的工作质量浓度,用西门子血浆标准品进行系列稀释作为标准品经过2轮实验来确定拟合曲线和线性范围及检测抗体的工作质量浓度,用血浆标准品标定电泳C1-INH标准品(电泳纯度>92%),分析与血浆标准品的平行性来选择本方法最终使用的标准品,最终建立了C1-INH抗原含量的双抗体夹心ELISA检测方法。对此方法进行线性、准确度、精密度、加样回收率、电泳标准品稳定性的验证。将验证后的方法用于C1-INH纯化工艺的摸索及产品质量分析,并与特定蛋白检测仪的结果进行比较。结果 捕获抗体质量浓度为400.000 ng/mL,检测抗体质量浓度为400.000 ng/mL,标准曲线采用四参数方程拟合,电泳标准品的质量浓度为0.895 mg/mL,血浆标准品作为本方法标准品;标准曲线的线性范围为1.560~100...  相似文献   

11.
烟草种质资源AFLP分析中DNA模板的制备   总被引:10,自引:1,他引:9  
采用CTAB法和SDS法提取烟草基因组DNA,经检测表明,CTAB法提取的基因组DNA纯度高于SDS法;CTAB法提取的DNA,其OD260/OD280值均高于1.8,相对分子量23kb左右,且能完全被EcoRⅠ和MseⅠ酶切消化,并能获得清晰的AFLP指纹图谱。  相似文献   

12.
This paper suggests a simple modification of the Ellman procedure when used to measure accurate changes in sulfhydryl (-SH) content induced by reactive oxygen intermediates (ROI). This modification became necessary when we found that the standard technique did not produce time invariant results in the presence of ROI-generating systems. Cysteine (cys; 20–100 μM) in 20 mM imidazole buffer (pH 7.0) containing 1.0 mM EDTA was reacted with excess (0.2 mM) 5,5′-dithiobis(2-nitrobenzoic acid), DTNB. The absorbance of the product (p-nitrothiophenol anion) was recorded at 412 nm (A412). This A412 was stable for 60 min and gave a linear relationship with cys concentrations used. ROI were generated either by 0.01 U xanthine oxidase (XO) + 0.01–1.0 mM hypoxanthine (HX), 0.01–1.0 mM H2O2, or H2O2 + 100 μM FeSO4. In the presence of ROI, A412 decreased with time and its rate of decrease was dependent upon the concentration of components of the ROI-generating system. This time-dependent decrease in A412 was prevented completely by the addition of 100 U of catalase (CAT). Therefore, we modified the DTNB method as follows: -SH groups were reacted with ROI for 30 min; this was followed by the addition of 100 U of CAT to scavenge the excess unreacted ROI before the addition of DTNB to generate the product. Using this modification the ROI-induced decrease in A412 was stable with time and was linearly related to the cys concentration. We further tested the modified procedure using metallothionein (MT) as a substrate for the ROI-induced changes in -SH content. MT, at concentrations of 2.5, 5.0, and 7.5 μM, was treated with XO + 100 μM HX. Using the modified procedure, an average decrease (as compared to the untreated control) of 15, 22, and 33 μM in -SH content was observed consistently at the respective MT concentrations. However, without the modification in the procedure, these average decrease were 20, 38, and 51 μM, respectively and continued to further increase with time. These discrepancies could give rise to errors ranging from 28 to 35% or higher in determination of the ROI-induced decrease in the -SH groups of MT. This data suggests that scavenging the unreacted H2O2 with C prior to the addition of DTNB to the assay mixture gives a stable and accurate estimate of the ROI-induced oxidative damage to -SH groups.  相似文献   

13.
精氨酸在医药和食品工业上具有广泛用途。集胞藻PCC 6803是单细胞蓝藻, 能利用工业废气(主要成分是氮氧化物NOx)与水反应生成的硝酸盐和亚硝酸盐合成氨基酸等化合物, 因而选育高产精氨酸藻株, 不仅能提高精氨酸产量, 而且能去除工业废气中的NOx, 具有潜在的应用前景。研究在集胞藻PCC 6803中利用紫外诱变, 筛选抗0.8 g/L D-精氨酸和抗0.2 g/L 6-氮尿嘧啶的突变株, 选育到了一株精氨酸产量显著提高的突变株#13807-111-55, 它每OD730值细胞的胞外精氨酸产量相比出发株提高了62.3倍, 达到(0.76±0.1) mg/(L·OD730), 总精氨酸产量相比出发株提高了6.0倍, 达到(0.82±0.08) mg/(L·OD730)。该突变株每OD730值细胞的胞外精氨酸产量明显高于胞内, 表明该突变藻株是精氨酸分泌型, 因而具有潜在的应用前景。  相似文献   

14.
毛豆中腈菌唑残留量的气相色谱法测定   总被引:4,自引:0,他引:4  
采用气相色谱法定量分析毛豆上腈菌唑的微量残留量。样品经乙腈提取,液液分配,中性氧化铝柱层析净化后,以气相色谱电子俘获检测器法(GC-ECD)测定,DB-1701毛细管柱、氮气为载气,柱温150℃20℃/min 260℃(10 min),气化室温度240℃,检测器温度300℃,外标法定量。该方法快速、准确,在0.05~2.00 mg/L范围内线性相关系数r2=0.9998,平均回收率91.1%~99.0%,变异系数1.22%~2.94%,最小检测量1.0×10-12 g,最低检出浓度5.0×10-4 mg/kg。  相似文献   

15.
目的:建立高灵敏度的阿特拉津酶联免疫吸附检测法。方法:将间接竞争ELISA进行条件优化以提高检测灵敏度,包括包被抗原与一抗的最佳工作浓度筛选、选择一抗的最佳稀释度对包被抗原进行细化筛选、不同有机溶剂对竞争结合反应的影响、酶标二抗稀释度筛选等。用建立的酶联免疫检测法检测实际样品,再与高效液相色谱法(HPLC)检测进行比较。结果:利用优化后条件建立了阿特拉津间接竞争ELISA检测曲线,标准曲线的相关系数R2=0.9958,相关性较好。另由此标准曲线可得LOD (最低检出限)为1.972 ng/ml。用于检测实际样品,回收率在80%-120%之间。当添加样品浓度为(0~6) ng/ml时,该法的检测灵敏度高于HPLC。结论:新建立的阿特拉津ELISA特异性好、精密度高,可代替大型仪器用于阿特拉津实际样品检测。  相似文献   

16.
Ellman’s assay is the most commonly used method to measure cholinesterase activity. It is cheap, fast, and reliable, but it has limitations when used for biological samples. The problems arise from 5,5-dithiobis(2-nitrobenzoic acid) (DTNB), which is unstable, interacts with free sulfhydryl groups in the sample, and may affect cholinesterase activity. We report that DTNB is more stable in 0.09 M Hepes with 0.05 M sodium phosphate buffer than in 0.1 M sodium phosphate buffer, thereby notably reducing background. Using enzyme-linked immunosorbent assay (ELISA) to enrich tissue homogenates for cholinesterase while depleting the sample of sulfhydryl groups eliminates unwanted interactions with DTNB, making it possible to measure low cholinesterase activity in biological samples. To eliminate possible interference of DTNB with enzyme hydrolysis, we introduce a modification of the standard Ellman’s assay. First, thioesters are hydrolyzed by cholinesterase to produce thiocholine in the absence of DTNB. Then, the reaction is stopped by a cholinesterase inhibitor and the produced thiocholine is revealed by DTNB and quantified at 412 nm. Indeed, this modification of Ellman’s method increases butyrylcholinesterase activity by 20 to 25%. Moreover, high stability of thiocholine enables separation of the two reactions of the Ellman’s method into two successive steps that may be convenient for some applications.  相似文献   

17.
水稻(Oryza sativa)根系照光实验表明, 光的效应随循环水影响到不照光的植株, 暗示营养液中发生了化学变化。在Si (K2SiO3)和Fe (FeEDTA)组成的溶液模拟系统中, 分别照射LED-紫光或阳光, 观察到反应液的OD400值随光照时间的延长而增加。光照引起的化学变化发生在FeEDTA和K2SiO3之间。化学变化只与光能量有关, 与溶液温度无关, 这是一种光化学反应。光化反应溶液的光吸收从OD360到OD560都有明显增高。LED-蓝光和阳光诱导产生的并含FeEDTA-SiO3成分并能吸收光的二元螯合铁硅酸盐复合物附着在衬底膜上, 形成三元复合物。衬底膜上可见大量的颗粒, 其中有些是反光的微晶颗粒。除LED-蓝光和阳光外, LED-紫光、LED-红光和LED-红外光也能诱导产生光谱性质相同的螯合铁硅酸盐复合物。制备含螯合铁硅酸盐复合分子的溶液并进行植物生长实验, 结果显示小球藻生长好, 死亡的藻体分解褪色后留下的是褐色的蓬松团状铁-硅化物。经螯合铁硅酸盐复合物处理的水稻干重增加明显。  相似文献   

18.
The influence of the pH of the mobile phase with some modifiers on the chromatographic behavior and fluorescence properties of closantel have been investigated. At acidic pH values (2–6), the benzamide moiety of the closantel forms a six-membered ring by hydrogen bonding and possesses a native fluorescence. Using the fluorescence emission of closantel at λex=335 nm, λem=510 nm, and pH 2.5 of the mobile phase, a linear calibration curve was estimated over a concentration range of about two orders of magnitude with a correlation coefficient larger than 0.992. The limit of the fluorescence detection was 10 μg/kg. This value was at least 10 times lower than that using UV detection. The method was applied to the determination of closantel in plasma and tissue samples, purified by a solid-phase extraction with C18 cartridges.  相似文献   

19.
目的:苯甲酸脱羧酶能够催化羧化反应固定CO2,为了获得高效的苯甲酸脱羧酶,需要利用高通量分子克隆与突变体筛选系统对产生的大量突变体进行筛选,因此建立、开发高效的筛选评价方法对于获得高羧化效率的突变体至关重要。方法:利用2,3-二羟基苯甲酸脱羧酶催化邻苯二酚固定CO2的反应体系,建立了光谱法-图像灰度法高通量筛选和评价固定CO2的苯甲酸脱羧酶突变体。利用分光光度法在308 nm快速定量羧化产物2,3-二羟基苯甲酸。同时利用高效液相色谱(HPLC)法对分光光度法的测定结果进行了校正,确定了分光光度法估算的2,3-二羟基苯甲酸浓度与HPLC方法测定的准确浓度之间具有良好的线性关系(R2 = 0.996)。利用HPLC-分光光度法的相关性可以获得实际样品中准确的2,3-二羟基苯甲酸浓度。利用Image J软件获得蛋白质标准品和突变体的灰度均值,根据灰度法定量蛋白质标准品的标准曲线计算突变体的蛋白质表达量。利用单位酶量催化邻苯二酚获得2,3-二羟基苯甲酸的浓度比较突变体的催化活性。结果:纯酶和粗酶体系下HPLC法测定的2,3-二羟基苯甲酸浓度与分光光度法测定的吸光度值的关系分别为C1=0.500A1-0.010(R2 = 0.996)和C2=1.458A2+0.431 9(R2 = 0.991)。从13个突变体中获得了两个正向突变体,羧化活性分别是WT的3.5倍和1.7倍。结论:基于光谱法-图像灰度法可以实现高通量筛选固定CO2的苯甲酸脱羧酶,该方法可用于具有相似功能的苯甲酸脱羧酶对其他取代基的酚类和水杨酸类似物的底物选择性筛选。  相似文献   