首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Measuring low amounts of anti‐erythropoietin antibodies (anti‐EPO Abs) is important to evaluate the therapeutic safety of recombinant human erythropoietin (rhEPO). In this work, a simple, sensitive and high‐throughput chemiluminescent (CL) imaging assay was developed for the detection of anti‐EPO Abs in human sera. The influence of several physicochemical parameters, such as coating conditions, incubation time, detergent concentration and exposure time, were investigated. A calibration curve was established and the range of quantitative detection was 0.12–13.91 ng/mL. The limit of detection (LOD, 3σ) for the CL‐imaging assay was 0.033 ng/mL. Compared to conventional colorimetric enzyme‐linked immunosorbent assay (ELISA), the LOD of the CL‐imaging assay is 50‐fold lower. The recoveries of anti‐EPO Abs in the fortified serum were in the range 87.1–116.9% using the present method, which highlighted the validity of the CL‐imaging assay system to accurately determine the anti‐EPO Abs in serum samples. CL‐imaging assay was used to evaluate the presence of anti‐EPO Abs in serum samples obtained from chronic renal failure (CRF) patients treated with rhEPO. Contrary to what was expected, the sera from CRF patients did not contain anti‐EPO Abs. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

2.
Pesticides have become part of food protection since their inception. Endosulfan, an organochlorine insecticide, has been used against insect pests such as whiteflies, aphids, red spiders and mites. Methods of immunochemical assays have been devised for the determination and analysis of pesticides and commonly used for the analysis of contaminants in food, water, soil and body fluids. Chicken IgY antibodies raised against endosulfan haptens were used for the detection of endosulfan. We have compared colorimetric (CO) and chemiluminescence (CL) enzyme‐linked immunosorbent assay (ELISA) techniques for the detection of endosulfan isomers in a food matrix. CL ELISA assay was found to be more sensitive than CO assay. The mean recovery was 81.2–95.6% for α‐ and β‐endosulfan‐spiked food samples with 2.8–4.6% relative standard deviation. The detection of the endosulfan isomers was linear in the range 100 µg/mL–5 fg/mL, with a limit of detection at 100 µg/mL and 5 fg/mL for the CL ELISA method and 100 µg/mL and 1 ng/mL for the CO ELISA method respectively. These methods can be used for the rapid and reliable detection of organochlorine pesticide endosulfan. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
A non‐competitive immunoassay based on capillary electrophoresis (CE) with chemiluminescence (CL) detection has been developed for the determination of luteinizing hormone (LH) in human serum. The work involved the development of separation and CL conditions, allowing for routine analysis of serum samples. In this study, horseradish peroxidase (HRP)‐labelled monoclonal anti‐LH can catalyse the luminol–hydrogen peroxide reaction. The determined LH can react with excessive amount of HRP‐labelled anti‐LH. Within 14 min, free enzyme conjugate and immune complex could be separated in alkaline borate buffer by means of a high voltage (15 kV). To improve sensitivity, a series of measures were adopted, including the choice of para‐iodophenol as a CL enhancer, unique design in detect window. Under the optimal conditions, the calibration curve for LH was established in the concentration range 1–200 mIU/mL and the detection limit was 0.08 mIU/mL. Compared with ELISA, this method decreased the detection limit by about 12 times, and it has been successfully employed in the determination of LH in human serum. Copyright © 2007 John Wiley & Sons, Ltd.  相似文献   

4.
A high‐throughput and simple chemiluminescence (CL) enzyme immunoassay (CLEIA) for the determination of progesterone (P) in human serum was developed, with the highly sensitive 4‐methoxy‐4‐(3‐phosphatephenyl)‐spiro‐(1,2‐dioxetane‐3,2′‐adamantane) (AMPPD)–alkaline phosphatase (ALP) system as the CL detection system. The results showed that the indirect immobilization of rabbit anti‐progesterone polyclonal antibody (RAPA) through secondary antibody exhibited apparent advantages over direct coating in terms of antibody saving and improvement of the coating stability and uniformity. The direct analysis of P in human serum without extraction was realized by using 8‐anilino‐1‐naphthalenesulphonic acid (ANS) to displace P from its binding proteins. The effect of several relevant parameters of the immunoreaction were examined and optimized. Compared with some commercial progesterone kits, the presented CLEIA has higher sensitivity with detection limitation as low as 0.06 ng/mL. The recoveries were 95.9–101%. The coefficient of variation was <8.4% and 9.9% for intra‐ and inter‐assay precision, respectively. This method has been successfully applied to the evaluation of P in human serum. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

5.
An enzyme-linked immunofiltration assay (ELIFA) and a microtitre plate enzyme-linked immunosorbent assay (ELISA) were developed and compared for their ability to detect staphylococcal enterotoxin B (SEB). The double antibody capture format was used for both assays. Factors which improved the sensitivity of the ELIFA system were (1) addition of casein and thimerosal to the antigen dilution buffer; (2) addition of polyethylene glycol (MW 6000) to the detection and conjugate antibody dilution buffers; and (3) washing with diethanolamine buffer prior to addition of the substrate/chromogen. The ELIFA system had a turnaround time of approximately 1 h and a detection limit of 1 ng/mL of purified SEB. The ELISA had a total turnaround time of 21 h, or 3 h using plates pre-coated overnight with the capture antibody. The detection limit of the ELISA for purified SEB was 0.05 ng/mL. The detection limit of SEB in cheese samples spiked with purified enterotoxin and subjected to a simple extraction procedure was 1 ng/mL and 0.1 ng/mL of extract, with the ELIFA and the ELISA, respectively.  相似文献   

6.
Highly sensitive detection of hepatitis C virus (HCV) in serum is a key method for diagnosing and classifying the extent of HCV infection. In this study, a p‐phenol derivative, 4‐(1,2,4‐triazol‐1‐yl)phenol (4‐TRP), was employed as an efficient enhancer of the luminol–hydrogen peroxide (H2O2)–horseradish peroxidase (HRP) chemiluminescence (CL) system for detection of HCV. Compared with a traditional enhancer, 4‐TRP strongly enhanced CL intensity with the effect of prolonging and stabilizing light emission. The developed CL system was applied to detecting HCV core antigen (HCV‐cAg) using a sandwich structure inside microwells. Our experimental results showed that there was good linear relationship between CL intensity and HCV‐cAg concentration in the 0.6–3.6 pg/mL range (R = 0.99). The intra‐ and inter‐assay coefficients of variation were 4.5–5.8% and 5.0–7.3%, respectively. In addition, sensitive determination of HCV‐cAg in serum samples using the luminol–H2O2–HRP–4‐TRP CL system was also feasible in clinical settings. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

7.
The area cultivated with Bt‐cottons expressing Cry1Ac gene increases year by year in China and other countries. To evaluate any potential adverse impacts on the environment from the release of Bt (Bacillus thuringiensis) technology, the development of a method for easily detecting the activity of the Cry1Ac toxins is of particular interest. The aim of this study was to develop sandwich‐ELISA for the detection of Cry1Ac protein in Bt‐cotton tissues. A specific antibody was obtained from rabbits inoculated with Cry1Ac protein derived from Bt strain HD‐73 and a secondary antibody conjugated to HRP could combine the Bt Cry1Ac protein specifically. The limit of detection was 5 ng/mL and there were no cross‐reactions between the positive control of Cry1Ab/1Ac, Cry1C, Cry2A, Cry3Bb1 and Cry9C. Extracts of proteins from cotton leaves were used to evaluate the suitability of the assay. Tris‐borate buffer and sodium carbonate buffer were employed for the extraction of protein, the limit absorbance of detection was 0.134 and 0.449, respectively, and the latter produced a higher background. The results showed that cultivars GK‐12, GK‐22, insect‐resistant cotton, bivalent transgenic cotton and shiyuan 321 assayed positively and NON was the negative sample. The PCR method was used for the validation of the developed assay. Although both methods allowed the same results to be obtained, ELISA needed simple equipment and took less time. The developed immunoassay method is considered reliable for the detection of Bt Cry1Ac protein.  相似文献   

8.
Isoenzyme c of horseradish peroxidase (HRP‐C) is widely used in enzyme immunoassay combined with chemiluminescence (CL) detection. For this application, HRP‐C activity measurement is usually based on luminol oxidation in the presence of hydrogen peroxide (H2O2). However, this catalysis reaction was enhancer dependent. In this study, we demonstrated that Jatropha curcas peroxidase (JcGP1) showed high efficiency in catalyzing luminol oxidation in the presence of H2O2. Compared with HRP‐C, the JcGP1‐induced reaction was enhancer independent, which made the enzyme‐linked immunosorbent assay (ELISA) simpler. In addition, the JcGP1 catalyzed reaction showed a long‐term stable CL signal. We optimized the conditions for JcGP1 catalysis and determined the favorable conditions as follows: 50 mM Tris buffer (pH 8.2) containing 10 mM H2O2, 14 mM luminol and 0.75 M NaCl. The optimum catalysis temperature was 30°C. The detection limit of JcGP1 under optimum condition was 0.2 pM. Long‐term stable CL signal combined with enhancer‐independent property indicated that JcGP1 might be a valuable candidate peroxidase for clinical diagnosis and enzyme immunoassay with CL detection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid and sensitive two‐step time‐resolved fluorescence immunoassay (TRFIA) was developed for the detection of Shiga toxin 2 (Stx2) and its variants in Shiga toxin‐producing Escherichia coli (STEC) strains. In sandwich mode, a monoclonal antibody against Stx2 was coated on a microtiter plate as a capture antibody. A tracer antibody against Stx2 labeled with europium(III) (Eu3+) chelate was then used as a detector, followed by fluorescence measurements using time‐resolved fluorescence. The sensitivity of Stx2 detection was 0.038 ng/ml (dynamic range, 0.1–1000 ng/ml). The intra‐ and inter‐assay coefficients of variation of the assay were 3.2% and 3.6%, respectively. The performance of the established assay was evaluated using culture supernatants of STEC strains, and the results were compared to those of a common HRP (horseradish peroxidase) labeling immunosorbent assay. A polymerase chain reaction (PCR) for the detection of genes encoding Stx1 and Stx2 was used as the reference for comparison. Correlation between the Stx2‐specific TRFIA and PCR was calculated by the use of kappa statics, exhibiting a perfect level of agreement. The availability of the sensitive and reliable Stx2‐specific TRFIA method for quantifying Stx2 and its variants in STEC strains will complement bacteria isolation‐based platform and aid in the accurate and prompt diagnosis of STEC infections.  相似文献   

10.
Aflatoxin B1 (AFB1) is one of the most commonly found mycotoxins in food commodities, particularly cereals, oilseeds, spices and tree nuts. In the past decade, aptamers have come into limelight and emerged as a new biosensing element replacing antibodies in various detection formats. Herein we report a faster, more sensitive, high throughput method for the detection of AFB1 using AFB1‐specific aptamers. The assay format was based on a competitive reaction of the fluorescent tagged aptamer specific to AFB1 with the aflatoxin conjugate. Under optimal conditions, a linear range of detection (50 ng to 50 pg) was achieved with a limit of detection (LOD) of 10 pg/mL in the buffer system. Results of inter‐ and intra‐assay revealed that the assay was repeatable with standard deviation in acceptable range. The assay was also validated in food samples such as dried red chilies, groundnut and whole pepper with recovery in the range of 92 to 102% at 10 ng/mL and 100 pg/mL levels. The aptasensor assay was also compared with standard analytical method of HPLC and was found to be more sensitive. This detection technique has the potential to be developed into a biosensor platform for AFB1 detection.  相似文献   

11.
目的建立百日咳组分疫苗丝状血凝素(FHA)抗原含量监控的ELISA检测法。方法制备的多克隆抗血清,经辛酸硫酸铵法纯化抗体,用过碘酸钠氧化法辣根过氧化物酶标记,以棋盘滴定法确定最佳包被抗体及酶标抗体的浓度配伍,建立了双抗体夹心ELISA检测法。结果对双抗体夹心ELISA法的特异性、最佳线性范围、检测限度、精密度、准确度、测定限量、适用性的一系列验证试验表明,该方法与百日咳组分疫苗中PT和Prn无明显交叉反应,特异性较好。在0至20 ng/mL测量区间有最佳线性,相关系数大于0.99;经实验内12次及不同试验间3次测定16、8、4 ng/mL中的FHA含量,变异系数在0.2%~11.4%间,回收率在96.9%~114.5%间,精密度及准确度验证均符合常规质控要求,因此测定限量为4 ng/mL。结论该方法能有效检测出百日咳杆菌培养上清中的FHA含量,可用于百日咳组分疫苗生产过程的中间品质量控制。  相似文献   

12.
目的:为检测血清中HSA-GLP-1融合蛋白整体分子的浓度,建立一种特异、灵敏的定量检测食蟹猴体内HSA-GLP-1融合蛋白浓度的双抗体夹心ELISA的方法。方法:采用双抗体夹心ELISA方法,以GLP-1单克隆抗体为包被抗体、HSA-GLP-1融合蛋白为夹心抗原、anti-HSA-Biotin为检测抗体,用Streptavidin-HRP进行免疫放大,TMB显色。结果:建立了检测HSA-GLP-1融合蛋白的ELISA方法,其线性范围为15.6~1000 ng/mL,最低检测限为15.6 ng/mL,与GLP-1、HSA、IL2-HSA均无交叉反应,板内和板间精密度均小于15%,准确度为±15%,冻融稳定性和稀释稳定性良好。结论:建立的HSA-GLP-1蛋白检测方法符合新生物制品临床前药代动力学研究指导原则要求,可用于HSA-GLP-1融合蛋白在临床前药代动力学试验的定量检测。  相似文献   

13.
A rapid, simple, facile, sensitive and enzyme‐amplified chemiluminescence immunoassay (CLIA) method to detect antibodies against porcine parvovirus has been developed. Horseradish peroxidase (HRP) and the detection antibody were simultaneously co‐immobilized on the surface of gold nanoparticles using the electrostatic method to form gold nanoparticle‐based nanoprobes. This nanoprobe was employed in a sandwich‐type CLIA, which enables CL signal readout from enzymatic catalysis and results in signal amplification. The presence of porcine parvovirus infection was determined in porcine parvovirus antibodies by measuring the CL intensity caused by the reaction of HRP–luminol with H2O2. Under optimal conditions, the obtained calibration plot for the standard positive serum was approximately linear within the dilution range of 1:80 to 1:5120. The limit of detection for the assay was 1:10,240 (S/N = 3), which is much lower than that typically achieved with an enzyme‐linked immunosorbent assay (1:160; S/N = 3). A series of repeatability measurements using 1:320‐fold diluted standard positive serum gave reproducible results with a relative standard deviation of 4.9% (n = 11). The ability of the immunosensor to analyze clinical samples was tested on porcine sera. The immunosensor had an efficiency of 90%, a sensitivity of 93.3%, and a specificity of 87.5% relative to the enzyme‐linked immunosorbent assay results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
《Luminescence》2003,18(2):72-78
We developed a competitive chemiluminescent (CL) enzyme immunoassay for rapid, sensitive analysis of 19‐nortestosterone (19‐NT) in bovine urine. Anti‐19‐NT polyclonal antibodies were raised in rabbits using a 19‐NT‐hemisuccinate derivative conjugated with ovalbumin; the derivative was also conjugated with horseradish peroxidase (HRP) as a label. Antibodies were immobilized on 384‐well black polystyrene microtitre plates and HRP‐labelled 19‐NT activity was measured using an efficient chemiluminescent substrate (SuperSignal® ELISA Femto) after 3 min incubation. Emitted light was recorded using a conventional, photomultiplier‐tube‐based microtitre plate reader or a sensitive back‐illuminated, cooled CCD camera. The developed method fulfils all the requirements of precision (intra‐ and inter‐assay CV < 10%) and accuracy (mean recovery 94–112%), with a detection limit of 0.03 ppb (1.1 × 10?9 mol/L) in a urine matrix. Chemiluminescence enhances detectability of the HRP‐labelled tracer (thus lowering the limit of detection with respect to colorimetry) and reduces analysis time. The 384‐well microtitre plate cuts the sample/reagent volume (20 µL), a five‐fold reduction with respect to the conventional 96‐well microtitre plate. The developed method is suitable for high‐throughput screening of 19‐NT in urine samples, with reduced costs as compared with conventional colorimetric enzyme immunoassays. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

15.
A rapid and sensitive time‐resolved fluoroimmunoassay (TR–FIA) based on the biotin–streptavidin amplification system was developed for the determination of diethylstilbestrol (DES). Europium‐labelled streptavidin derivatives combined with europium and anhydride of diethylene triamine penta‐acetic acid were used to label streptavidin; biotin was coupled with goat anti‐rabbit IgG to form a biotin–goat anti‐rabbit IgG bridge between streptavidin–europium and the anti‐DES antibody in the immunoassay. The DES assay was carried out by measuring the fluorescence of Eu3+–SA at 615 nm. The presented method produced a wide linear range, 0.001–1000.0 ng/mL, and a detection limit up to 0.81 pg/mL for DES. The method was applied to determine DES in serum samples, with recoveries of 97.4–107.8% and RSD 1.32–4.04%. The assay results by the present method showed that biotin–streptavidin amplified TR–FIA for DES detection; it may offer high sensitivity and promising alternative special methods in biological samples. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
Despite the availability of many assays to measure concentrations of tumour necrosis factor alpha (TNF-alpha) in body fluids, these assays often lack specificity or sensitivity and are often of questionable reliability, resulting in inconsistent results. Therefore, we have developed an ELISA that is sensitive, reliable and not susceptible to disturbances by interfering substances such as heterophilic antibodies. The assay involves a combination of four polyclonal antibodies. The antibodies, which capture the analyte, were raised in chicken and the trapping anti-analyte antibodies were raised in rabbit. The immobilization of capture antibodies was achieved via a coating antibody raised in a duck against chicken IgY and the recognition of trapping antibodies was achieved by a detection antibody raised in a goat against rabbit IgG and labelled with HRP. The analytical and functional sensitivities of the ELISA are 8 pg/mL and 13 pg/mL, respectively. The assay showed good precision and, in contrast to our in-house RIA, excellent parallelism in serial dilutions. The recovery of TNF-alpha spiked to plasma samples ranged from 97% to 119%. Comparison of the newly developed, sensitive ELISA with our in-house RIA showed that the median TNF-alpha value obtained by RIA (range: 0.095-10.0, median 0.578 ng/mL) was found to be 1.5-2 times higher than that obtained with the ELISA (range 0.008-5.84, median 0.213 ng/mL). Spearman correlation was 0.755 (p < 0.0001). In addition, analysis of the TNF-alpha concentrations in blood from healthy individuals and from patients suffering from tuberculosis, with RIA and ELISA, showed the same differences although TNF-alpha levels obtained with ELISA were lower. We feel that this ELISA is a major improvement compared to the currently available assays for TNF.  相似文献   

17.
Direct competitive chemiluminescence immunoassays (CLIA) based on gold‐coated magnetic nanospheres (Au‐MNPs) were developed for rapid analysis of chloramphenicol (CAP). The Au‐MNPs were modified with carboxyl groups and amino groups by 11‐mercaptoundecanoic acid (MUA) and cysteamine respectively, and then were respectively conjugated with CAP base and CAP succinate via an activating reaction using 1‐ethyl‐3‐(3‐dimethylaminopropyl)carbodiimide hydrochloride (EDC) and N‐hydroxysuccinimide (NHS). NSP‐DMAE‐NHS, a new and effective luminescence reagent, was employed to label anti‐CAP antibody (mAb) as a tracer in direct CLIA for CAP detection using a ‘homemade’ luminescent measurement system that was set up with a photomultiplier tube (PMT) and a photon counting unit linked to a computer. The sensitivities and limits of detection (LODs) of the two methods were obtained and compared according to the inhibition curves. The 50% inhibition concentration (IC50) values of the two methods were about 0.044 ng/mL and 0.072 ng/mL respectively and LODs were approximately 0.001 ng/mL and 0.006 ng/mL respectively. To our knowledge, they were much more sensitive than any traditional enzyme‐linked immunosorbent assay (ELISA) ever reported. Moreover, the new luminescence reagent NSP‐DMAE‐NHS is much more sensitive and stable than luminol and its derivatives, contributing to the sensitivity enhancement. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

18.
Phage display method was used to clone anti‐carbofuran (CBF) single chain Fv (scFv) gene. The heavy chain and light chain variable region genes were amplified by the polymerase chain reaction from the CBF‐specific hybridoma cell lines 5D3 and assembled as a scFv DNA fragment with linker peptide (Gly4Ser)3. The scFv DNA fragment was cloned into M13 phagemid vector pCANTAB5E and the anti‐CBF antibody libraries were then constructed. After one round of panning with CBF‐ovalbumin (CBF‐OVA) as a conjugate, antigen‐binding positive recombinant phage clones were successfully selected by enzyme‐linked immunosorbent assay (ELISA). The positive phages were used to infect Escherichia coli HB2151 cells and the expression of the soluble scFv antibodies was then induced by IPTG. The scFv antibody was about 31 kDa by SDS‐PAGE and showed HRP‐anti‐E‐tag antibody‐recognized activity by Western blotting. The indirect competitive ELISA (icELISA) showed that the recombinant scFv antibody could competitively combine with CBF, with the IC50 value of 1.07 ng/mL. The cross reactivity studies showed that the anti‐CBF scFv antibody, similar to the parent monoclonal antibody, poses high specificity to CBF and has little reactivity to the analogs. Taken together, these findings suggest that the recombinant scFv antibody can be used for further developing immunoassay method for CBF. © 2009 American Institute of Chemical Engineers Biotechnol. Prog., 2009  相似文献   

19.
In this study, we applied tyramide signal amplification (TSA) to fluorescence enzyme-linked immunosorbent assay (ELISA) employing horseradish peroxidase (HRP) as the detection enzyme. When used with a human epidermal growth factor ELISA kit, the TSA method led to a >100-fold increase in fluorescence signal intensity in comparison to an unamplified method. It also showed wider dynamic range and better sensitivity compared to a conventional method using tetramethylbenzidine as the HRP substrate.  相似文献   

20.
8‐Amino‐5‐chloro‐7‐phenylpyrido[3,4‐d]pyridazine‐1,4(2H,3H)dione (L‐012) was recently synthesized as a new chemiluminescence (CL) probe; the light intensity and the sensitivity of L‐012 are higher than those of other CL probes such as luminol. Previously, our group developed four lophine‐based CL enhancers of the horseradish peroxidase (HRP)‐catalyzed CL oxidation of luminol, namely 2‐(4‐hydroxyphenyl)‐4,5‐diphenylimidazole (HDI), 2‐(4‐hydroxyphenyl)‐4,5‐di(2‐pyridyl)imidazole (HPI), 4‐(4,5‐diphenyl‐1H‐imidazol‐2‐yl)phenylboronic acid (DPA), and 4‐[4,5‐di(2‐pyridyl)‐1H‐imidazol‐2‐yl]phenylboronic acid (DPPA), and showed that DPPA was suitable for the photographic detection of HRP. In this study, we replaced luminol with L‐012 and evaluated these as L‐012‐dependent CL enhancers. In addition, to detect HRP and/or H2O2 with higher sensitivity, each detection condition for the L‐012–HRP–H2O2 enhanced CL was optimized. All the derivatives enhanced the L‐012‐dependent CL as well as luminol CL; HPI generated the highest enhanced luminescence. Under optimized conditions for HRP detection, the detection limit of HRP was 0.08 fmol. By contrast, the detection limit of HRP with the enhanced L‐012‐dependent CL using 4‐iodophenol, which is a common enhancer of luminol CL, was 1.1 fmol. With regard to H2O2 detection, the detection limits for enhanced CL with HPI and 4‐iodophenol were 0.29 and 1.5 pmol, respectively. Therefore, it is demonstrated that HPI is the most superior L‐012‐dependent CL enhancer. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号