首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
Isoenzyme c of horseradish peroxidase (HRP‐C) is widely used in enzyme immunoassay combined with chemiluminescence (CL) detection. For this application, HRP‐C activity measurement is usually based on luminol oxidation in the presence of hydrogen peroxide (H2O2). However, this catalysis reaction was enhancer dependent. In this study, we demonstrated that Jatropha curcas peroxidase (JcGP1) showed high efficiency in catalyzing luminol oxidation in the presence of H2O2. Compared with HRP‐C, the JcGP1‐induced reaction was enhancer independent, which made the enzyme‐linked immunosorbent assay (ELISA) simpler. In addition, the JcGP1 catalyzed reaction showed a long‐term stable CL signal. We optimized the conditions for JcGP1 catalysis and determined the favorable conditions as follows: 50 mM Tris buffer (pH 8.2) containing 10 mM H2O2, 14 mM luminol and 0.75 M NaCl. The optimum catalysis temperature was 30°C. The detection limit of JcGP1 under optimum condition was 0.2 pM. Long‐term stable CL signal combined with enhancer‐independent property indicated that JcGP1 might be a valuable candidate peroxidase for clinical diagnosis and enzyme immunoassay with CL detection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
Direct competitive chemiluminescence immunoassays (CLIA) based on gold‐coated magnetic nanospheres (Au‐MNPs) were developed for rapid analysis of chloramphenicol (CAP). The Au‐MNPs were modified with carboxyl groups and amino groups by 11‐mercaptoundecanoic acid (MUA) and cysteamine respectively, and then were respectively conjugated with CAP base and CAP succinate via an activating reaction using 1‐ethyl‐3‐(3‐dimethylaminopropyl)carbodiimide hydrochloride (EDC) and N‐hydroxysuccinimide (NHS). NSP‐DMAE‐NHS, a new and effective luminescence reagent, was employed to label anti‐CAP antibody (mAb) as a tracer in direct CLIA for CAP detection using a ‘homemade’ luminescent measurement system that was set up with a photomultiplier tube (PMT) and a photon counting unit linked to a computer. The sensitivities and limits of detection (LODs) of the two methods were obtained and compared according to the inhibition curves. The 50% inhibition concentration (IC50) values of the two methods were about 0.044 ng/mL and 0.072 ng/mL respectively and LODs were approximately 0.001 ng/mL and 0.006 ng/mL respectively. To our knowledge, they were much more sensitive than any traditional enzyme‐linked immunosorbent assay (ELISA) ever reported. Moreover, the new luminescence reagent NSP‐DMAE‐NHS is much more sensitive and stable than luminol and its derivatives, contributing to the sensitivity enhancement. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

3.
Highly sensitive detection of hepatitis C virus (HCV) in serum is a key method for diagnosing and classifying the extent of HCV infection. In this study, a p‐phenol derivative, 4‐(1,2,4‐triazol‐1‐yl)phenol (4‐TRP), was employed as an efficient enhancer of the luminol–hydrogen peroxide (H2O2)–horseradish peroxidase (HRP) chemiluminescence (CL) system for detection of HCV. Compared with a traditional enhancer, 4‐TRP strongly enhanced CL intensity with the effect of prolonging and stabilizing light emission. The developed CL system was applied to detecting HCV core antigen (HCV‐cAg) using a sandwich structure inside microwells. Our experimental results showed that there was good linear relationship between CL intensity and HCV‐cAg concentration in the 0.6–3.6 pg/mL range (R = 0.99). The intra‐ and inter‐assay coefficients of variation were 4.5–5.8% and 5.0–7.3%, respectively. In addition, sensitive determination of HCV‐cAg in serum samples using the luminol–H2O2–HRP–4‐TRP CL system was also feasible in clinical settings. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

4.
Acetaminophen, also called paracetamol, is found in Tylenol, Excedrin and other products as over–the‐counter medicines. In this study, acetaminophen as a luminol signal enhancer was used in the chemiluminescence (CL) substrate solution of horseradish peroxidase (HRP) for the first time. The use of acetaminophen in the luminol–HRP–H2O2 system affected not only the intensity of the obtained signal, but also its kinetics. It was shown that acetaminophen was to be a potent enhancer of the luminol–HRP–H2O2 system. A putative enhancement mechanism for the luminol–H2O2–HRP–acetaminophen system is presented. The resonance of the nucleophilic amide group and the benzene ring of acetaminophen structure have a great effect on O‐H bond dissociation energy of the phenol group and therefore on phenoxyl radical stabilization. These radicals act as mediators between HRP and luminol in an electron transfer reaction that generates luminol radicals and subsequently light emission, in which the intensity of CL is enhanced in the presence of acetaminophen. In addition, a simple method was developed to detect acetaminophen by static injection CL based on the enhanced CL system of luminol–H2O2–HRP by acetaminophen. Experimental conditions, such as pH and concentrations of substrates, have been examined and optimized. The proposed method exhibited good performance, the linear range was from 0.30 to 7.5 mM, the relative standard deviation was 1.86% (n = 10), limit of detection was 0.16 mM and recovery was 99 ± 4%. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

5.
This article describes a microfluidic immunosensor, developed for the detection of IgG antibodies specific to Echinococcus granulosus in human serum samples, which represents an alternative tool that can be used for the immunodiagnosis of hydatidosis in an automated way. Our device consists of a Plexiglas system with a central channel and a gold electrode. For immobilization of the E. granulosus antigen, a gold electrode was modified with the incorporation of gold nanoparticles. Immobilized antigen was allowed to react with IgG-anti-E. granulosus antibodies in samples, and these were quantified by horseradish peroxidase (HRP) enzyme-labeled secondary antibodies specific to human IgG using catechol (Q) as enzymatic mediator. HRP in the presence of hydrogen peroxide (H2O2) catalyzes the oxidation of Q to o-benzoquinone (P). The electrochemical reduction back to Q was detected on the gold electrode (AuE) at −0.15 V. The current obtained was proportional to the activity of the enzyme and to the concentration of antibodies of interest. The detection limit for electrochemical detection was 0.091 ng ml−1, and the within- and between-assay coefficients of variation were below 6.7%. The proposed system presents many benefits, the more relevant are: reduced complexity and costs that are considered as the most wanted features for the clinical-immunodiagnostic field.  相似文献   

6.
The polymerization of proteins can create newly active and large bio‐macromolecular assemblies that exhibit unique functionalities depending on the properties of the building block proteins and the protein units in polymers. Herein, the first enzymatic polymerization of horseradish peroxidase (HRP) is reported. Recombinant HRPs fused with a tyrosine‐tag (Y‐tag) through a flexible linker at the N‐ and/or Ctermini are expressed in silkworm, Bombyx mori. Trametes sp. laccase (TL) is used to activate the tyrosine of Y‐tagged HRPs with molecular O2 to form a tyrosyl‐free radical, which initiates the tyrosine coupling reaction between the HRP units. A covalent dityrosine linkage is also formed through a HRP‐catalyzed self‐crosslinking reaction in the presence of H2O2. The addition of H2O2 in the self‐polymerization of Y‐tagged HRPs results in lower activity of the HRP polymers, whereas TL provides site‐selectivity, mild reaction conditions and maintains the activity of the polymeric products. The cocrosslinking of Y‐tagged HRPs and HRP‐protein G (Y‐HRP‐pG) units catalyzed by TL shows a higher signal in enzyme‐linked immunosorbent assay (ELISA) than the genetically pG‐fused HRP, Y‐HRP‐pG, and its polymers. This new enzymatic polymerization of HRP promises to provide highly active and functionalized polymers for biomedical applications and diagnostics probes.  相似文献   

7.
In this article, a novel sandwich-type electrochemical immunosensor based on the signal amplification strategy of diazotization-coupling concept for ultrasensitive detection of carcinoembryonic antigen (CEA) was reported. It operates through physisorption of monoclonal anti-CEA on 4-aminothiophenol (4Atp) functionalized gold electrode interface as the detection platform. Diazo-4Atp-coupled-thionine (Thi)-conjugated gold nanoparticles (GNPs) were prepared for immobilization of horseradish peroxidase (HRP) and secondary anti-CEA to form core-shell bioconjugates that were used as electrochemical signal amplification reagent. The sensitivity of the immunosensor was greatly amplified by a dual amplification: one is that a large number of thionine and HRP was introduced on the electrode surface through sandwich immunoreaction, the other is that HRP as enhancer could catalyze the oxidation reaction of thionine by H(2)O(2), which results in great enhancement of the reduction peak current. Thus, the bioconjugates-based assay provided an amplification approach for detecting CEA at trace levels and led to a detection limit as low as 0.7 pg/mL (at a three times signal-to-noise ratio) that is well-below the threshold value of 2.5 ng/mL for clinical diagnosis. The assay was evaluated for clinical serum samples with various CEA concentrations and received in excellent accordance with the results obtained from the referenced enzyme-linked immunosorbent assay (ELISA).  相似文献   

8.
A simple and ultrasensitive flow injection chemiluminescence competitive immunoassay based on gold nanoparticle‐loaded enzyme for the detection of chloramphenicol (CAP) residues in shrimp and honey has been developed. Due to their good biocompatibility and large specific surface area, carboxylic resin beads can be used as solid phase carriers to immobilize more coating antigens (Ag). In addition, gold nanoparticles could provide an effective matrix for loading more CAP antibody and horseradish peroxidase, which would effectively catalyze the system of luminol–p‐iodophenol (PIP)–H2O2. A competitive immunoassay strategy was used for detection of CAP, in which CAP in the sample would compete with the coating Ag for the limited antibodies, leading to a chemiluminescence (CL) signal decrease with increase in CAP concentration. A wide linear range 0.001–10 ng ml?1 (R2 = 0.9961) was obtained under optimized conditions, and the detection limit (3σ) was calculated to be 0.33 pg ml?1. This method was also been successfully applied to determine CAP in shrimp and honey samples. The immunosensor proposed in this study not only has the advantages of high sensitivity, wider linear range, and satisfactory stability, but also expands the application of flow injection CL immunoassay in antibiotic detection.  相似文献   

9.
《Luminescence》2002,17(1):5-10
A sensitive and simple chemiluminescent assay (CL) for alkaline phosphatase (ALP) using dihydroxyacetone phosphate or its ketal (DHAP or DHAP‐ketal) was developed. New substrates were transformed to dihydroxyacetone (DHA) after they were hydrolysed by ALP, which reacts with lucigenin and produces strong chemiluminescence. Under the optimum assay condition, the detection limits were 3.8 × 10?19 and 1.5 × 10?18 moles of ALP, respectively. The coefficients of variation (CV) at each points on the standard curve were 0.8–5.4% and 1.8–7.1% (n = 6), respectively. The mechanism of lucigenin CL with DHA was investigated by ESR spectrometry using the spin‐trapping method. The mechanism was speculated as follows: the O2? generated by the reaction of DHA and O2 in alkaline solution reacts with lucigenin, and then emit light. The proposed CL assay was applied to the enzyme immunoassay of 17β‐oestradiol, using ALP as a label enzyme. The measurable range of 17β‐oestradiol was 15–4000 pg/mL, and the proposed method was four times more sensitive than the colorimetric assay for ALP by using 4‐nitrophenyl phosphate as substrate. Copyright © 2002 John Wiley & Sons, Ltd.  相似文献   

10.
The occurrence of many diseases is closely related to the high expression of DNA methyltransferase 1 (DNMT1). However, most studies are focused on the detection of DNMT1 activity, a few are concerned with the detection of DNMT1 content. In this study, we developed a simple and highly sensitive chemiluminescence (CL) assay for the detection of DNMT1 content. In this method, anti‐DNMT1 monoclonal antibody was coated on a polystyrene microplate to capture DNMT1. Then anti‐DNMT1 polyclonal antibody and goat anti‐rabbit immunoglobulin G with horseradish peroxidase (IgG‐HRP) were respectively added to combine with captured DNMT1 to form a sandwich structure. Finally, the HRP could catalyze CL substrate and achieve CL signal response. Based on this novel sensitive strategy, the recovery percents were in the ranges from 71.5% to 91.0%. The precision of intra‐assays and inter‐assays were 5.45%–11.29% and 7.03%–11.25%, respectively. The method was successfully applied for the determination of DNMT1 in human serum. The detection results of serum samples showed that the proposed assay had a high correlation with enzyme‐linked immunosorbent assay (ELISA) kit. Compared with the ELISA kit (limit of detection = 0.1 ng/mL), the method has a lower limit of detection of 0.042 ng/mL. Therefore, our method has the potential for the detection of DNMT1 content in clinical diagnosis.  相似文献   

11.
In this paper, a simple, easily-operated and enzyme-amplified fluorescence immunoassay method using magnetic particles for the detection of antibody against Actinobacillus pleuropneumoniae (APP) has been presented. The A protein of APP Repeats-in-Toxin IV (ApxIVA) with high specificity to the APP species was immobilized onto the magnetic bead surfaces. Horseradish peroxidase (HRP), which can catalyze the substrate 4-hydroxyphenylacetic acid (p-HPA), generating fluorescent bi-p, p'-hydroxyphenylacetic acid (DBDA), was selected as an enzymatic-amplified tracer. The ApxIVA antibody was detected for the presence of APP infection by measuring the fluorescence intensity of DBDA. Under optimal conditions, the calibration plot obtained for standard positive serum was approximately linear within the dilution range 1:160-1:5120. The limit of detection (LOD) for the assay was 1:10240, considerably lower than that of ApxIVA-ELISA (1:320) (S/N=3). A series of repeatability measurements of using 1:320-fold diluted standard positive serum gave reproducible results with a relative standard deviation (RSD) of 4.8% (n=11). The ability of the immunosensor to analyze clinical samples was tested on porcine sera. The immunosensor yielded an efficiency of 89.7%, sensitivity of 90.9% and specificity of 89.3% compared with ApxIVA-ELISA.  相似文献   

12.
In this study, a novel tracer, horseradish peroxidase (HRP) functionalized gold nanorods (Au NRs) nanocomposites (HRP–Au NRs), was designed to label the signal antibodies for sensitive electrochemical measurement of alpha-fetoprotein (AFP). The preparation of HRP–Au NRs nanocomposites and the labeling of secondary antibody (Ab2) were performed by one-pot assembly of HRP and Ab2 on the surface of Au NRs. The immunosensor was fabricated by assembling carbon nanotubes (CNTs), Au NRs, and capture antibodies (Ab1) on the glassy carbon electrode. In the presence of AFP antigen, the labels were captured on the surface of the Au NRs/CNTs via specific recognition of antigen–antibody, resulting in the signal intensity being clearly increased. Differential pulse voltammetry (DPV) was employed to record the response signal of the immunosensor in phosphate-buffered saline (PBS) containing hydrogen peroxide (H2O2) and 3,3′,5,5′-tetramethylbenzidine (TMB). Under optimal conditions, the signal intensity was linearly related to the concentration of AFP in the range of 0.1–100 ng ml−1, and the limit of detection was 30 pg ml−1 (at signal/noise [S/N] = 3). Furthermore, the immunoassay method was evaluated using human serum samples, and the recovery obtained was within 99.0 and 102.7%, indicating that the immunosensor has potential clinical applications.  相似文献   

13.
8‐Amino‐5‐chloro‐7‐phenylpyrido[3,4‐d]pyridazine‐1,4(2H,3H)dione (L‐012) was recently synthesized as a new chemiluminescence (CL) probe; the light intensity and the sensitivity of L‐012 are higher than those of other CL probes such as luminol. Previously, our group developed four lophine‐based CL enhancers of the horseradish peroxidase (HRP)‐catalyzed CL oxidation of luminol, namely 2‐(4‐hydroxyphenyl)‐4,5‐diphenylimidazole (HDI), 2‐(4‐hydroxyphenyl)‐4,5‐di(2‐pyridyl)imidazole (HPI), 4‐(4,5‐diphenyl‐1H‐imidazol‐2‐yl)phenylboronic acid (DPA), and 4‐[4,5‐di(2‐pyridyl)‐1H‐imidazol‐2‐yl]phenylboronic acid (DPPA), and showed that DPPA was suitable for the photographic detection of HRP. In this study, we replaced luminol with L‐012 and evaluated these as L‐012‐dependent CL enhancers. In addition, to detect HRP and/or H2O2 with higher sensitivity, each detection condition for the L‐012–HRP–H2O2 enhanced CL was optimized. All the derivatives enhanced the L‐012‐dependent CL as well as luminol CL; HPI generated the highest enhanced luminescence. Under optimized conditions for HRP detection, the detection limit of HRP was 0.08 fmol. By contrast, the detection limit of HRP with the enhanced L‐012‐dependent CL using 4‐iodophenol, which is a common enhancer of luminol CL, was 1.1 fmol. With regard to H2O2 detection, the detection limits for enhanced CL with HPI and 4‐iodophenol were 0.29 and 1.5 pmol, respectively. Therefore, it is demonstrated that HPI is the most superior L‐012‐dependent CL enhancer. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

14.
A strategy has been applied to chloramphenicol (CAP) detection with chemiluminescence immunoassays (CLIA) based on cheap functionalized Fe3O4@SiO2 magnetic nanoparticles (Fe–MNPs). The strategy that bovine serum albumin (BSA) was immobilized on cheap functionalized Fe–MNPs and that the CAP molecules were then immobilized on BSA, avoided the long process of dialysis for preparation of the BSA‐CAP conjugates. The samples were detected for both methods that utilized two different kinds of functionalized Fe–MNPs (amine‐functionalized Fe3O4@SiO2 and carboxylic acid‐functionalized Fe3O4@SiO2). The sensitivities and limits of detection (LODs) of the two methods were obtained and compared based on inhibition curves. The 50% inhibition concentrations (IC50) values of the two methods were about 0.024 ng ml?1 and 0.046 ng ml?1 respectively and LODs were approximately 0.0002 ng ml?1 and 0.001 ng ml?1 respectively. These methods were much more sensitive than that of any traditional enzyme‐linked immunosorbent assay (ELISA) previously reported. Therefore, such chemiluminescence methods could be easily adapted for small molecule detection in a variety of foods using Fe–MNPs.  相似文献   

15.
Porcine parvovirus is a widespread infectious viral disease with serious consequences to the reproductive health of swine. We have expressed the VP2 capsid protein of porcine parvovirus in the leaves of low alkaloid transgenic tobacco at approximately 0.3% of total soluble protein. Self-assembled virus-like particles were observed in planta by electron microscopy. Total soluble protein was extracted from the plant tissue and administered to mice by subcutaneous injection. An immune response was detected in these mice. The ability of serum antibodies to neutralize the infectivity of porcine parvovirus was further examined by a serum neutralization assay and was determined to be 1:2700–1:3900, a clear indication of the potential of VP2 expressed in plant material as a subunit vaccine against porcine parvovirus.  相似文献   

16.
Prostaglandin E2 is one of the major cyclooxygenase metabolites of arachidonic acid. We developed a competitive immunosorbent assay for prostaglandin E2 utilizing a bioluminescent enzyme Cypridina luciferase. The prostaglandin E2 amount could be quantified over the concentration ranging from 7.8 to 500 pg/mL. The amount of unlabeled prostaglandin E2 required to displace 50% of the maximal binding of Cypridina luciferase‐labeled prostaglandin E2 (B/B0) was approximately 35 pg/mL. The results show a great potential of Cypridina luciferase as a new labeling enzyme for enzyme‐linked immunosorbent assay. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
Colloidals solution of Fe3O4 magnetic nanoparticles (MNPs), capped with β‐cyclodextrins (β‐CD) as inclusion complexes, were found to enhance the chemiluminescence (CL) intensity of the luminol–diperiodatoargentate(III) (DPA) system. On injection of cysteine into the luminol–DPA–β‐CD–Fe3O4 MNPs inclusion complexes system, the CL intensity is strongly enhanced. The enhanced CL signal is ascribed to the catalytic effect of Fe3O4 MNPs capped with β‐CD, which is assumed to stabilize the CL intermediate. Based on these findings, a rapid and sensitive assay was developed for the determination of cysteine in human serum. The effects of analytical variables on the CL signal were studied and optimized. Under the optimum conditions, the CL intensity was directly proportional to the concentration of cysteine in the range 8.0 × 10–9–1.0 × 10–6 mol/L. The detection limit was 2.8 × 10–9 mol/L (3 Sb/m) and the relative standard deviation (RSD) for 10 replicate determinations of 1.0 × 10–7 mol/L cysteine was 3.5%. The proposed method was applied to the sensitive determination of cysteine in human serum samples, and compared with the Ellman method with satisfactory results. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
A novel and sensitive chemiluminescence (CL) procedure based on the synergetic catalytic effects of gold nanoclusters (Au NCs) and graphene quantum dots (GQDs) was developed for the reliable measurement of cimetidine (CM). The initial experiments showed that the KMnO4‐based oxidation of alkaline rhodamine B (RhoB) generated a very weak CL emission, which was intensively enhanced in the simultaneous presence of Au NCs and GQDs. CL intermediates can be adsorbed and gathered on the surface of Au NCs, becoming more stable. GQDs participate in the energy transferring processes and facilitate them. These improving effects were simultaneously obtained by adding both Au NCs and GQDs into the RhoB‐KMnO4 reaction. Consequently, the increasing effect of the Au NCs/GQDs mixture was more than that of pure Au NCs or GQDs, and a new nano‐assisted powerful CL system was achieved. Furthermore, a marked quenching in the emission of the introduced CL system was observed in the presence of CM, so the system was examined to design a sensitive sensor for CM. After optimization of influencing parameters, the linear lessening in CL emission intensity of KMnO4‐RhoB‐Au NCs/GQDs was verified for CM concentrations in the range 0.8–200 ng ml?1. The limit of detection (3Sb/m) was 0.3 ng ml?1. Despite being a simple CL method, good sensitivity was obtained for CM detection with reliable results for CM determination in human urine samples.  相似文献   

19.
Reactive oxygen species (ROS) are presently thought to play important role in an increasing number of the physiological and pathological processes in living organisms. Various chemiluminescent (CL) compounds have been studied in order to find suitable and specific probes for the detection of particular ROS species. The CL of luminol is known to be non‐specific and can be induced by various oxidants. Two Cypridina luciferin analogues, CLA and MCLA, have been used for the detection of ROS in vivo. CLAs are thought to emit light only when reacting with superoxide and singlet oxygen. It is possible to distinguish the particular ROS by using a specific quencher or scavenger, e.g. superoxide dismutase (SOD) or sodium azide (NaN3). The CL reactions of luminol (3‐aminophthalhydrazide), CLA [2‐methyl‐6‐phenyl‐3,7‐dihydroimidazo(1,2α) pyrazin‐3‐one] and MCLA [2‐methyl‐6‐(p‐methoxyphenyl)‐3,7‐dihydroimidazo(1,2α) pyrazin‐3‐one] were studied in three hydrogen peroxide decomposition systems (H2O2–HRP; H2O2–CuSO4; and H2O2–NaOCl). The measurements were carried out in phosphate buffer, pH 7.4, at 25 °C, using a luminometer (Fluoroskan Ascent FL and Sirius C). NaN3 was used as the specific quencher of singlet oxygen. The results demonstrate that the proclaimed specifity of the CL of Cypridina luciferin analogues towards singlet oxygen has to be discussed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

20.
This paper presents a comparison between surface plasmon resonance (SPR) and capacitive immunosensors for a flow injection label-free detection of cancer antigen 125 (CA 125) in human serum. Anti-CA 125 was immobilized on gold surface through a self-assembled monolayer. Parameters affecting the responses of each system were optimized. Under optimal conditions, SPR provided a detection limit of 0.1 U ml−1 while 0.05 U ml−1 was obtained for the capacitive system. Linearity for SPR was between 0.1 and 40 U ml−1 and 0.05–40 U ml−1 for capacitive system. These immunosensors were applied to analyze CA 125 concentrations in human serum samples and compared with conventional enzyme linked fluorescent assay (ELFA). Both systems showed good agreement with ELFA (P < 0.05). Moreover, these immunosensors were very stable and provided good reproducible responses after regeneration, up to 32 times for SPR and 48 times for capacitive system with relative standard deviation lower than 4%. The SPR immunosensor provided advantages in term of fast response and real-time monitoring while capacitive immunosensor offered a sensitive and cost-effective method for CA 125 detection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号