首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
应用ELISA法检测风疹病毒IgG抗体   总被引:1,自引:0,他引:1  
实验证明,将0.1%脱氧胆酸钠制备的风疹病毒粗制抗原,用于ELISA法检测风疹病毒IgG抗体,效果较满意,方法的特异性好,与常规血凝抑制试验(HI)的相关性也好,所测抗体的几何平均值为HI的4倍。用本法初步调查了北京市不同年龄人群的风疹感染率,证明随年龄增长风疹感染率迅速上升,18岁以上人群达94%。检测河北省沧州地区孕妇的风疹IgG阳性率为99%。用於风疹病人的血清学诊断,获得较好结果。  相似文献   

2.
捕捉法ELISA检测流行性乙型脑炎IgM抗体用于早期快速诊断   总被引:3,自引:1,他引:2  
张礼壁  刘玉清 《病毒学报》1989,5(4):378-382
  相似文献   

3.
A shortened IgM capture ELISA for the detection of dengue IgM antibodies using simultaneous incubation of antigen and peroxidase-labeled monoclonal antibody was described. The shortened two-step assay was compared with the four-step IgM capture ELISA on sera from dengue patients confirmed by the hemagglutination inhibition (HI) test. When paired acute and convalescent sera were tested, the shortened ELISA showed 100% agreement with HI results. It detected dengue IgM antibodies in the acute sera of 66% of patients with a primary dengue infection, 60% of patients with a secondary infection, and 98% of patients with a presumptive secondary infection. When the results of 151 dengue patients were combined, 75% of the acute sera were positive by the shortened IgM capture ELISA.  相似文献   

4.
Toxoplasmosis, a world-wide zoonotic infection, is generally asymptomatic and benign in immunocompetent individuals, but it can be serious in immunodeficiencies particularly in patients with acquired immunodeficiency syndrome and in children infected in utero. So, it is important to dispose methods which permit discriminate between recent and chronic infections. In order to contribute to improve the diagnosis of toxoplasmosis ELISA IgG, IgM, IgA and ELISA IgG avidity were performed in 15 and 24 sera from patients suspected of having acute and chronic infection respectively, according dye test (DT) titres. ELISA IgG was positive in both groups, ELISA IgM was positive in 78.6 and 58.3% respectively, while ELISA IgA was positive in 85.7 and 33.3% of recent and chronic group respectively. In those sera with low IgG avidity (18.8%) we found specific IgM in 71.5 and 4.2% and IgA in 78.6 and 0.0% of recent and chronic groups respectively. Parallelling, 208 sera samples were classified according to the results of DT, indirect hemagglutination and complement fixation tests in the following groups: acute (97), intermediate (36), chronic (35) and negative (40). The results were: acute (96.9-64.9-55.6 and 65.9%); intermediate (97.2-63.8-44.4 and 47.2%); chronic (45.7-42.8-5.7 and 34.3%) for IgG, IgM, IgA and low IgG avidity respectively. The use of both acute markers, IgA and low IgG avidity in the diagnosis of toxoplasmosis is discussed.  相似文献   

5.
为了制备临床诊断用的风疹病毒抗原,建立了亲合色谱分离纯化的方法.风疹抗原以可溶性形式在大肠杆菌工程菌中获得高效表达,用GST亲合色谱在不变性的条件下直接从细菌裂解液中分离纯化.纯化的目的蛋白电泳为单一条带,EUISA试验表明,重组抗原与风疹病毒IgM阳性血清能特异反应,而与IgM阴性血清不反应,表明重组蛋白具有良好的抗原性,能满足临床检验要求.  相似文献   

6.
IgM and IgG immunoglobulins of human sera were separated by stepwise column chromatography in QAE-Sephadex A-25 ion exchanger gel bed. The procedure resulted within 30 min in a fraction suitable for direct titration of rubella-specific IgM antibodies by haemagglutination inhibition test. The method proved to be a useful diagnostic tool for primary rubella. Serum samples of 13 individuals with previously acquired immunity, 152 patients with a recent rubella-like illness, and 194 pregnant women exposed to rubella infection were tested for the presence of rubella-specific IgM antibodies. Sera of individuals with previous immunity proved to be negative for specific IgM antibodies. Specific IgM titre was demonstrated in the blood of all the 25 patients with significant titre-rise tested because of rubella-like illness, and also in the sera of additional 8 patients whose serum samples were taken too late for demonstration of a rise in titre. Significant titre-rises were found in 5 women exposed to rubella infection, but only two of them exhibited rubella-specific IgM antibodies. The absence of specific IgM antibodies refers presumably to subclinical reinfection in the other three cases.  相似文献   

7.
This paper presents the evaluation of an enzyme immunoassay in which Mayaro virus-infected cultured cells are used as antigen (EIA-ICC) and an IgM antibody capture ELISA (MAC-ELISA) for Mayaro serologic diagnosis using 114 human sera obtained during a Mayaro outbreak occurred in Bolivia, in 1987. Results were compared with those obtained by haemagglutination-inhibition test (HAI). MAC-ELISA was the most sensitive technique for anti-Mayaro IgM detection. MAC-ELISA was twice as sensitive as IgM EIA-ICC. The data shows that MAC-ELISA is a practical and valid technique for diagnosis of recent Mayaro infection. IgG EIA-ICC showed high sensitivity and high specificity compared to HAI. The combination of anti-Mayaro IgG and IgM EIA-ICC results presented the highest sensitivity of the study. Anti-Mayaro IgG and IgM simultaneous detection by EIA-ICC can be used for recent infection diagnosis (in spite of a less sensitive IgM detection than by MAC-ELISA), for surveillance and sero-epidemiologic studies, and for studies of IgG and IgM responses to Mayaro infection.  相似文献   

8.
A hemagglutination-inhibition (HI) test for rubella is described which utilizes human group O, rather than 1-day-old chick, erythrocytes. The test was found to be as sensitive and reproducible for detection of rubella antibody as HI tests employing chick erythrocytes. Advantages to the use of human erythrocytes are (i) they are more available, (ii) it is unnecessary to absorb natural agglutinins from human test sera, and (iii) heparin-MnCl2-treated sera do not agglutinate human erythrocytes, as is sometimes the case with chick erythrocytes. Factors influencing the reliability of the test are discussed.  相似文献   

9.
The applicability of the immunofluorescence (IF) test to the diagnosis of primary rubella infection was investigated. The test is based on the detection of rubella-specific antibodies in the IgM fraction of immunoglobulins. The results indicate the usefulness of the IF test for the diagnosis of primary rubella infection on a single serum specimen collected at a proper time. The test is also of value in the differentiation of primary infection from reinfection, since in reinfection no rubella-specific antibodies are found in the IgM fraction. The test is also valuable for the detection of fetal infection in utero since the persistence of IgM antibodies in pregnant women is indicative of fetal infection.  相似文献   

10.
Three foreign and one Russian ELISA test-systems for detection of IgM to Borrelia burgdorferi sensu lato were comparatively studied with the use of the clinical material in an encoded experiment. In the foreign ELISA test-systems based on the use of native antigens of borrelia, cross reactions with sera from patients with syphilis, Epstein-Barr infection, cytomegalovirus infection and systemic lupus erythematosus were detected. The Russian recombinant ELISA test-system Borreliosis-ELISA-IgM showed high sensitivity and specificity. The simultaneous use of the test-systems for detecting IgG and IgM significantly increased the efficacy of diagnosis of early borreliosis.  相似文献   

11.
We recently described the first recombinant Schistosoma mansoni protein RP26, which was capable of acute infection diagnosis. The aim of the present work was to further characterize the RP26 diagnostic properties in immunoblot and enzyme-linked immunosorbent (ELISA) assays. Testing sera from uninfected donors and sera from patients with acute or chronic Schistosoma infection by Western blot immunoassay revealed 100% specificity and 100% sensitivity for acute infection identification. Sera from uninfected, acute, and chronic schistosomiasis were also probed for IgG, IgG4, IgA, and IgM reactivity to RP26 plus soluble egg antigens (SEA) in ELISA. The mean IgG reactivity to RP26 by sera from acute schistosomiasis patients was significantly higher than the chronic ones. The IgG4, IgA, and IgM reactivities to RP26 were low and similar in both infected groups. The mean IgA and IgM reactivities to SEA were significantly higher in the group of acute compared to chronic group, whereas mean IgG4 reactivity was higher in chronic group. To estimate the specificity of Schistosoma infection diagnosis sera from patients infected with other different parasites were tested to detect IgG reactivity to RP26 and IgA and IgM reactivity to SEA. For IgA against SEA detection, 72% of sera were positive and 48% of sera were positive for IgM detection. Based on these results we can suggest that detection of sera IgG binding to RP26 is a sensitive and specific method for acute schistosomiasis diagnosis. Therefore, RP26 is a candidate for immunodiagnostic kit development.  相似文献   

12.
Hitherto, epidemiological surveys of viral disease in Nigeria had been concentrated mostly on arboviral infections. This could be due to prevalence of the arthropod vectors responsible for the arboviral infections in this country. Recently, however, the Departments of Paediatrics and Ophthalmology of the University College Hospital, Ibadan, reported an alarming number of cases of congenital heart defects and cataracts in some infants in the wards. The clinical histories of these cases seemed to incriminate congenital rubella infection. A serological survey of females of child-bearing age was carried out the detection of antibodies to rubella virus using the haemagglutination-inhibition (HI) test. The results showed that over 70% of the sera tested were positive for rubella HI antibody.  相似文献   

13.
首次建立了用于脊髓灰质炎快速、分型诊断的血清IgM抗体捕捉法ELISA。检测了52例疑似病人,IgM阳性率为76.9%(40/52),而粪便病毒分离率仅为44.2%(23/52),前者的阳性检出率明显高于后者。做病毒分型诊断结果,与分离病毒中和试验定型的总符合率为92.86%(39/42)。检测601例来自全国各省的脊灰疑似病人血清,其阳性率波动于13%~92.3%,平均为61.1%。阳性率与收集血清的病日相关,发病0~3天收集者,阳性检出率为69.5%,4~25天者为64%,26~54天者为52%,55天以上者则未能检出。本检测方法需时1.5天,简便、敏感、特异,重复性良好,适用于脊灰的早期快速诊断。对其实用性进行了讨论。  相似文献   

14.
The rubella haemagglutination inhibition (HI) test can be simplified and the probelm of non-specific inhibitors circumvented by allowing the haemagglutinin to react with erythrocytes before addition of the serum specimen. The elaboration of the test procedure is described, and preliminary studies indicate that the new method may prove useful both in the diagnosis of rubella infection and for determination of immunity status.  相似文献   

15.
Toxoplasmosis has been well known as an important human infection to consider especially in pregnant women. Although many serologic methods are available, the diagnosis of toxoplasmosis can be extremely difficult. The presence of increased levels of Toxoplasma-specific IgG antibodies indicates an infection, but it does not differentiate between a recent and past infection. The purpose of our study was to compare the performance of the ELISA T. gondii IgG/IgM test, a widely used enzyme-linked immunosorbent assay, to the ELISA IgG avidity method. One hundred and four serum samples (from 38 males and 66 females) were tested and evaluated from symptomatic patients (chorioretinitis, lymphadenopathy), and from women in their first trimester of pregnancy who were suspected of having toxoplasmosis. The high IgG avidity and ELISA IgG antibody levels were in agreement for 51 of the specimens (49.0%). Thirty-eight discrepant (borderline) results from the IgG avidity method were positive for IgM (3 specimens) and IgG (37 specimens). Interestingly, out of the eight serum samples that were positive for both IgG and IgM antibodies, two samples were low IgG avidity, and three samples were borderline. There was no statistically significant relation observed between the results of the IgG avidity method and the ELISA IgG test, and the IgG avidity method and ELISA IgM test (chi2 = 1.987; p = 0.370 and chi2 = 2.152; p = 0.341, respectively). The IgG avidity method was considered easy to perform and an acceptable approach for the differentiation of discrepant results (recent/chronic) and for the current detection of T. gondii antibodies. We concluded that the determination of IgG avidity is a helpful tool for the diagnosis of the ocular form of toxoplasmosis and it is a safe method for screening this disease in the first trimester of pregnancy.  相似文献   

16.
抗体捕捉ELISA法在诊断柯萨奇A16病毒感染中的应用   总被引:2,自引:0,他引:2  
朱托夫  张礼壁 《病毒学报》1989,5(2):172-175
  相似文献   

17.
Immunopathogenesis studies employing West Nile virus (WNV) mice model are important for the development of antivirals and vaccines against WNV. Since antibodies produced in mice early during WNV infection are essential for clearing virus from the periphery, it is important to detect early and persistent anti-WNV antibodies. ELISA and plaque reduction neutralization tests are traditionally used for detection of anti-WNV antibodies and WNV-neutralizing antibodies, respectively. Although these assays are sensitive and specific, they are expensive and time consuming. Microsphere immunoassays (MIA) are sensitive, specific, allow for high throughput, are cost effective, require less time to perform than other methods, and require low serum volumes. Several assay parameters such as serum heat-inactivation (HI) and dilution can alter WNV MIA sensitivity. We examined the effect of these parameters on WNV E-protein MIA (WNV E-MIA) for the enhanced detection of anti-WNV IgM and IgG antibodies. WNV E-MIA was conducted using serial dilutions of HI and non-HI (NHI) serum collected at various time points from mice inoculated with WNV. HI significantly enhanced detection of IgM and IgG antibodies as compared to NHI serum. WNV IgM and IgG antibodies in HI sera were detected earlier at day 3 and IgM antibodies persisted up to day 24 after infection. HI serum at 1∶20 dilution was found to be optimal for detection of both IgM and IgG antibodies as compared to higher-serum dilutions. Further, addition of exogenous complement to the HI serum decreased the WNV E-MIA sensitivity. These results suggest that serum-HI and optimal dilution enhance WNV E-MIA sensitivity by eliminating the complement interference, thereby detecting low-titer anti-WNV antibodies during early and late phases of infection. This improved MIA can also be readily employed for detection of low-titer antibodies for detection of other infectious agents and host proteins.  相似文献   

18.
A new commercial anti-Japanese encephalitis virus IgM and IgG indirect immunofluorescence test (IIFT) was evaluated for the detection of the humoral immune response after Japanese encephalitis vaccination. The IgM IIFT was compared to two IgM capture ELISAs and the IgG IIFT was analysed in comparison to a plaque reduction neutralization test (PRNT50) and an IgG ELISA. Moreover, the course of the immune reaction after vaccination with an inactivated JEV vaccine was examined. For the present study 300 serum samples from different blood withdrawals from 100 persons vaccinated against Japanese encephalitis were used. For the IgM evaluation, altogether 78 PRNT50 positive samples taken 7 to 56 days after vaccination and 78 PRNT50 negative sera were analyzed with the Euroimmun anti-JEV IgM IIFT, the Panbio Japanese Encephalitis - Dengue IgM Combo ELISA and the InBios JE Detect IgM capture ELISA. For the IgG evaluation, 100 sera taken 56 days after vaccination and 100 corresponding sera taken before vaccination were tested in the PRNT50, the Euroimmun anti-JEV IgG IIFT, and the InBios JE Detect IgG ELISA. The Euroimmun IgM IIFT showed in comparison to the Panbio ELISA a specificity of 95% and a sensitivity of 86%. With respect to the InBios ELISA, the values were 100% and 83.9%, respectively. The analysis of the Euroimmun IgG IIFT performance and the PRNT50 results demonstrated a specificity of 100% and a sensitivity of 93.8%, whereas it was not possible to detect more than 6.6% of the PRNT50 positive sera as positive with the InBios JE Detect IgG ELISA. Thus, the IIFT is a valuable alternative to the established methods in detecting anti-JEV antibodies after vaccination in travellers and it might prove useful for the diagnosis of acutely infected persons.  相似文献   

19.
In immunoglobulin fractions or after elimination of IgG by absorption the immunofluorescence test for rubella IgM antibodies is more sensitive than in whole serum. Blocking of IgM activity by IgG antibodies was eliminated when the time of incubation of the serum with virus antigen was prolonged. After prolonged incubation higher titres of rubella antibodies were also obtained in the IgM immunoglobulin fractions. Protein A in Staphylococcus aureus suspension effectively absorbs antibodies of IgG class. The IgM antibody titres in absorbed sera of patients infected with rubella were in some cases 2 to 4 times higher than in unabsorbed sera.  相似文献   

20.
Considering the short lifetime of IgA antibodies in serum and the key advantages of antibody detection ELISAs in terms of sensitivity and specificity, Bio-Rad has just developed a new ELISA test based on the detection of specific anti-dengue IgA. This study has been carried out to assess the performance of this Platelia Dengue IgA Capture assay for dengue infection detection. A total of 184 well-characterized samples provided by the French Guiana NRC sera collection (Laboratory of Virology, Institut Pasteur in French Guiana) were selected among samples collected between 2002 and 2013 from patients exhibiting a dengue-like syndrome. A first group included 134 sera from confirmed dengue-infected patients, and a second included 50 sera from non-dengue infected patients, all collected between day 3 and day 15 after the onset of fever. Dengue infection diagnoses were all confirmed using reference assays by direct virological identification using RT-PCR or virus culture on acute sera samples or on paired acute-phase sera samples of selected convalescent sera. This study revealed: i) a good overall sensitivity and specificity of the IgA index test, i.e., 93% and 88% respectively, indicating its good correlation to acute dengue diagnosis; and ii) a good concordance with the Panbio IgM capture ELISA. Because of the shorter persistence of dengue virus-specific IgA than IgM, these results underlined the relevance of this new test, which could significantly improve dengue diagnosis accuracy, especially in countries where dengue virus is (hyper-) endemic. It would allow for additional refinement of dengue diagnostic strategy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号