首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 21 毫秒
1.
A sensitive and high throughput off-line μElution 96-well solid-phase extraction (SPE) followed by strong cation exchange (SCX) liquid chromatography with tandem mass spectrometry (LC/MS/MS) quantification for determination of cefepime has been developed and validated in mouse plasma. Using the chemical analog, ceftazidime as an internal standard (IS), the linear range of the method for the determination of cefepime in mouse plasma was 4–2048 ng/mL with the lower limit of quantitation level (LLOQ) of 4 ng/mL. The inter- and intra-assay precision and accuracy of the method were below 9.05% and ranged from 95.6 to 113%, respectively, determined by quality control (QC) samples at five concentration levels including LLOQ. After μElution SPE, 71.1% of cefepime was recovered. The application of the validated assay for the determination of cefepime in mouse pharmacokinetics (PK) samples after intravenous (IV) and subcutaneous (SC) doses was demonstrated.  相似文献   

2.
A rapid and sensitive LC-MS/MS method for the quantification of ondansetron was developed and validated. The plasma samples were treated by a semi-automated liquid-liquid extraction (LLE) in 1.2 mL 96-well format micro-tubes. Ondansetron and the internal standard (IS) granisetron were analyzed by combined reversed phase LC-MS/MS, with positive ion electrospray ionization, using multiple reactions monitoring (MRM). The statistical evaluation for this method reveals excellent linearity, accuracy and precision values for the range of concentrations 0.25-40.0 ng/mL. The proposed method enabled the reliable determination of ondansetron in bioequivalence studies after per os administration of a 4 or 8 mg tablet.  相似文献   

3.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration.  相似文献   

4.
The predominant circulating folate monoglutamate in human plasma (>90%), and thus the most significant folate for accurately diagnosing folate deficiency, is 5-methyltetrahydrofolic acid (5 MT). Folate deficiency is typically indicated when circulating folate levels are < or = 3 ng/mL. The quantitative determination of plasma folates in general, and of 5 MT in particular, is complicated by their naturally low levels (pg/mL to ng/mL), their instability, and their tendency to interconvert. Highly specific and sensitive analytical methods are needed to accurately quantify endogenous 5 MT in human plasma. A method that utilizes the specific high-affinity binding sites of bovine folate binding protein (FBP) and the selectivity and sensitivity of selected ion monitoring mode isotope-dilution liquid chromatography/mass spectrometry (LC/MS) to quantify plasma 5 MT has been developed. The method is based on the solid-phase affinity extraction (SPAE) of 5 MT and its stable isotopically labeled analogue ([13C(5)]5 MT) from plasma (1 mL) using FBP immobilized to polymeric beads. The excess high-affinity binding sites on the affinity columns enable quantitative extraction of 5 MT from plasma under optimized sample pH conditions. Additionally, it is demonstrated that plasma proteins do not hinder the determination of 5 MT; therefore, protein precipitation is not required before the affinity extraction step. Detection and quantification of the extracted 5 MT is provided by positive-ion mode LC/MS in which the protonated molecular ions [M+H](+) of the analyte and the internal standard are monitored. The method shows linearity over three orders of magnitude (0.04-40 ng/mL) and has limits of detection and quantification of 0.04 and 0.4 ng/mL, respectively. Calibration curves obtained by spiking 5 MT into plasma exhibited good linearity between 0 and 25 ng/mL and both the plasma calibration standards and the plasma samples were stable for at least 48 h at room temperature. The recovery (average +/- % RSD) of 5 MT spiked into plasma from 5 to 25 ng/mL was 98.0% +/- 1.6% (n = 15). 5 MT levels determined by SPAE-LC/MS compared to "total folate" levels determined by radioassay and microbiological assay were discordant. Reasons for the discordancy are theorized, but it is clear that there exists an urgent need for clinical reference materials containing certified folate levels.  相似文献   

5.
A sensitive spectrofluorimetric method was developed for the determination of tizanidine in human plasma, urine and pharmaceutical preparations. The method is based on reaction of tizanidine with 1‐dimethylaminonaphthalene‐5‐sulphonyl chloride (dansyl chloride) in an alkaline medium to form a highly fluorescent derivative that was measured at 511 nm after excitation at 383 nm. The different experimental parameters affecting the fluorescence intensity of tizanidine was carefully studied and optimized. The fluorescence–concentration plots were rectilinear over the ranges 50–500 and 20–300 ng/mL for plasma and urine, respectively, detection limits of 1.81 and 0.54 ng/mL and quantification limits of 5.43 and 1.62 ng/mL for plasma and urine, respectively. The method presents good performance in terms of linearity, detection and quantification limits, precision, accuracy and specificity. The proposed method was successfully applied for the determination of tizanidine in pharmaceutical preparations. The results obtained were compared with a reference method, using t‐ and F‐tests. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

6.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   

7.
Protodioscin (3-O-[alpha-L-rhamnopyranosyl-(1-->2)-{alpha-L-rhamnopyranosyl-(1-->4)}-beta-D-glucopyranosyl]-26-O-[beta-D-glucopyranosyl]-(25 R)-furost-5-ene-3 beta,26-diol) is a naturally occurring saponin present in many oriental vegetables and traditional medicinal plants, which has been associated with potent bioactivity. However, there is no specific and sensitive assay for quantitative determination of protodioscin in biological samples. We have established a rapid, sensitive and selective LC-ESI-MS/MS method to measure protodioscin in rat plasma and investigated the pharmacokinetics of protodioscin after intravenous administrations. Plasma samples were prepared after plasma protein precipitation, and a aliquot of the supernatant was injected directly onto an analytical column with a mobile phase consisted of acetonitrile-water-formic acid (80:20:0.1, v/v/v). Analytes were detected with a LC-ESI-MS/MS system in positive selected multiple reaction-monitoring mode. The lower limit of quantification (LLOQ) was 20.0 ng/mL and a linear range of 20-125,000 ng/mL. The intra- and inter-day relative standard deviation (R.S.D.) across three validation runs over the entire concentration range was <8.0%. Accuracy determined at three concentrations (50, 5000 and 50,000 ng/mL for protodioscin) ranged from 0.2 to 1.8% as terms of relative error (R.E.). Each plasma sample was chromatographed within 3.5 min. This LC-ESI-MS/MS method allows accurate, high-throughput analysis of protodioscin in small amounts of plasma.  相似文献   

8.
A new LC-ESI-MS/MS assay method has been developed and validated for the quantification of swertiamarin, a representative bioactive substance of Swertia plants, in rat plasma using gentiopicroside, an analog of swertiamarin on chemical structure and chromatographic action, as the internal standard (IS). The swertiamarin and IS were extracted from rat plasma using solid-phase extraction (SPE) as the sample clean-up procedure, and they were chromatographed on a narrow internal diameter column (Agilent ZORBAX ECLIPSE XDB-C(18) 100 mm × 2.1 mm, 1.8 μm) with the mobile phase consisting of methanol and water containing 0.1% acetic acid (25:75, v/v) at a flow rate of 0.2 mL/min. The detection was performed on an Agilent G6410B tandem mass spectrometer by negative ion electrospray ionisation in multiple-reaction monitoring mode while monitoring the transitions of m/z 433 [M+CH(3)COO](-)→179 and m/z 415 [M+CH(3)COO](-)→179 for swertiamarin and IS, respectively. The lower limit of quantification (LLOQ) was 5 ng/mL within a linear range of 5-1000 ng/mL (n=7, r(2)≥0.994), and the limit of detection (LOD) was demonstrated as 1.25 ng/mL (S/N≥3). The method also afforded satisfactory results in terms of sensitivity, specificity, precision (intra- and inter-day), accuracy, recovery, freeze/thaw, long-time stability and dilution integrity. This method was successfully applied to determination of the pharmacokinetic properties of swertiamarin in rats after oral administration at a dose of 20 mg/kg. The following pharmacokinetic parameters were obtained (mean): maximum plasma concentration, 1920.1 ng/mL; time to reach maximum plasma concentration, 0.945 h; elimination half-time, 1.10h; apparent total clearance, 5.638 L/h/kg; and apparent volume of distribution, 9.637 L/kg.  相似文献   

9.
A sensitive, specific and rapid liquid chromatographic/tandem mass spectrometric (LC/MS/MS) assay for the determination of allylestrenol in human plasma was established. Plasma samples were extracted by tert-butyl ether and separated by LC/MS/MS using a Phenomenex Curosil-PFP column (250 mm x 4.6 mm ID, dp 5 microm) with a mobile phase of methanol-water (95:5, v/v). The analytes were monitored with atmospheric pressure chemical ionization (APCI) by selected reaction monitoring (SRM) mode. The linear calibration curves covered a concentration range of 0.04-20.0 ng/mL with lower limit of quantification (LLOQ) at 0.04 ng/mL. The mean extraction recovery of allylestrenol was greater than 81.8%. The intra- and inter-day precisions were less than 1.3% and 3.1% respectively, determined from quality control (QC) samples of three representative concentrations. The method has been successfully applied to determining the plasma concentration of allylestrenol and a clinical pharmacokinetics study in healthy Chinese female volunteers.  相似文献   

10.
A selective and sensitive method for the simultaneous determination of hypericin and hyperforin--the two main active ingredients of St. John's Wort (SJW) extract--in human plasma depending on liquid/liquid-extraction and LC/MS/MS detection has been developed, validated after specifying the stability of the photosensitive hypericin in plasma samples during light exposure and applied to samples of a patient. After extraction with ethyl acetate/n-hexane in the darkness, sample extracts were chromatographed isocratically within 6 min on a Kromasil RP-18 column. The analytes were detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source. The limit of quantification was 0.05 ng/mL for hypericin and 0.035 ng/mL for hyperforin. The accuracy of the method varied between 101.9 and 114.2% and the precision ranged from 4.7 to 15.4% (S.D., batch-to-batch) for both analytes. The method was linear at least between 0.05 and 10 ng/mL for hypericin and between 0.035 and 100 ng/mL for hyperforin. Using this method hypericin and hyperforin were determined successfully in a patient over seven days following discontinuation of exposure with therapeutic doses of St. John's Wort extract.  相似文献   

11.
Isosorbide 5-mononitrate (5-ISMN) is an organic nitrate widely used for its vasodilating properties in the treatment of angina pectoris. In the present study, an efficient, sensitive, robust method was developed for the determination and quantification of isosorbide 5-mononitrate, in human plasma, by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS), using photospray ionization. Isosorbide 5-mononitrate was extracted from 0.5 mL human plasma by liquid-liquid extraction (LLE). The method had a chromatographic run of 2.0 min using a C(8) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 20 to 2000 ng mL(-1) (r(2)>0.995). The between-run precision, based on the relative standard deviation replicate quality controls, was 7.9% (60 ng mL(-1)), 5.2% (300 ng mL(-1)) and 7.0% (1800 ng mL(-1)). The between-run accuracy was 94.9%, 94.1% and 88.8% for the above-mentioned concentrations, respectively. The method herein described was employed in a bioequivalence study of two tablet formulations of isosorbide 5-mononitrate 40 mg.  相似文献   

12.
A sensitive, specific and fast high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) assay for the determination of vinorelbine in mouse and human plasma is presented. A 200 microL aliquot was extracted with solid-phase extraction (SPE) using Bond-Elut C(2) cartridges. Dried extracts were reconstituted in 100 microL 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) containing the internal standard vintriptol (100 ng/mL) and 10 microL volumes were injected onto the HPLC system. Separation was achieved on a 50 mm x 2.0 mm i.d. Gemini C(18) column using isocratic elution with 1 mM ammonium acetate pH 10.5-acetonitrile-methanol (21:9:70, v/v/v) at a flow rate of 0.4 mL/min. HPLC run time was only 5 min. Detection was performed using positive ion electrospray ionization followed by tandem mass spectrometry (ESI-MS/MS). The assay quantifies vinorelbine from 0.1 to 100 ng/mL using human plasma sample volumes of 200 microL. With this method vinorelbine can be measured in mouse plasma samples when these samples are diluted eight times in control human plasma. Calibration samples prepared in control human plasma can be used for the quantification of the drug. The lower limit of quantification in mouse plasma is 0.8 ng/mL. This assay is used to support preclinical and clinical pharmacologic studies with vinorelbine.  相似文献   

13.
A rapid and sensitive liquid chromatography/mass spectrometry (LC/MS) method was developed and validated for the determination of rimantadine in rat plasma. Rimantadine was extracted by protein precipitation with methanol, and the chromatographic separation was performed on a C(18) column. The total analytical run time was relatively short (4.6 min), and the limit of assay quantification (LLOQ) was 2 ng/mL using 50 microL of rat plasma. Rimantadine and the internal standard (amantadine) were monitored in selected ion monitoring (SIM) mode at m/z 180.2 and 152.1, respectively. The standard curve was linear over a concentration range from 2 to 750 ng/mL, and the correlation coefficients were greater than 0.999. The mean intra- and inter-day assay accuracy ranged from 100.1-105.0% to 100.3-104.0%, respectively, and the mean intra- and inter-day precision was between 1.3-2.3% and 1.8-3.0%, respectively. The developed assay method was successfully applied to a pharmacokinetic study in rats after oral administration of rimantadine hydrochloride at the dose of 20 mg/kg.  相似文献   

14.
A sensitive and reliable method for the determination of gamma-aminobutyric acid (GABA), a major inhibitory neurotransmitter, in human plasma and cerebrospinal fluid (CSF) has been developed. The method is based on capillary liquid chromatography (LC)/tandem mass spectrometry (MS/MS) using deuterium-labeled GABA (gamma-aminobutyric acid-2,2-D(2), GABA-d(2)) as internal standard. Pre-column derivatization with 7-fluoro-4-nitrobenzoxadiazole (NBD-F) was deployed, allowing both effective in-line pre-concentration and sensitive tandem MS detection of the analyte. An extraction column (10 mm x 0.25 mm, 7 microm, C(18)) was used for preconcentrating and stacking the sample. Separation was carried out on an analytical column (50 mm x 0.25 mm, 5 microm, C(18)). Characteristic precursor-to-product ion transitions, m/z 267--> 249 (for NBD-GABA) and m/z 269--> 251 (for NBD-GABA-d(2)) were monitored for the quantification. A linear calibration curve from 10 to 250 ng/mL GABA with an r(2) value of 0.9994 was obtained. Detection limit was estimated to be 5.00 ng/mL GABA (S/N = 3). Human plasma and CSF samples were analyzed. The concentrations of GABA were found to be 98.6 +/- 33.9 ng/mL (mean +/- S.D., n = 12), and 44.3 +/- 10.0 ng/mL (n = 6) in plasma and CSF, respectively.  相似文献   

15.
A simple and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method using an atmospheric pressure chemical ionization source (APCI) for the quantification of fenretinide (4-HPR) in mouse plasma was developed and validated. After a simple protein precipitation of plasma sample by acetonitrile, 4-HPR was analyzed by LC-APCI-MS/MS. High-performance liquid chromatography (HPLC) separation was conducted on a Hypurity C18 column (50mmx2.1mm, 5microm) with a flow rate 0.60mL/min using a gradient mobile phase comprised of 0.05% formic acid in water (A) and methanol (B), and a run time of 4.5min. The elimination of a tedious sample preparation process and a shorter run time substantially reduced total analysis time. The method was linear over the range 0.5-100ng/mL, with r>0.998. The intra- and inter-assay precisions were 1.4-9.2% and 5.1-8.2%, respectively, and the intra- and inter-assay accuracies were 93.9-98.6% and 92.7-95.3%, respectively. The absolute recoveries were 90.3% (1.5ng/mL), 97.0% (7.5ng/mL) and 92.1% (75.0ng/mL) for 4-HPR, and 99.1% for the internal standard (150ng/mL). The analytical method had excellent sensitivity using a small sample volume (30microL) with the lower limit of quantification (LLOQ) 0.5ng/mL. This method is robust and has been successfully employed in a pharmacokinetic study of 4-HPR in a mouse xenograft model of neuroblastoma.  相似文献   

16.
A selective, rapid and sensitive ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was developed for the quantitative determination of azithromycin in human plasma and its application in a pharmacokinetic study. With roxithromycin as internal standard, sample pretreatment involved a one-step extraction with diethyl ether of 0.5 mL plasma. The analysis was carried out on an ACQUITY UPLC BEH C(18) column (50 mm x 2.1 mm, i.d., 1.7 microm) with gradient elution at flow rate of 0.35 mL/min. The mobile phase was 50 mM ammonium acetate and acetonitrile. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via electrospray ionization (ESI). Linear calibration curves were obtained in the concentration range of 1-1000 ng/mL, with a lower limit of quantification of 1 ng/mL. The intra- and inter-day precision (RSD) values were below 15% and accuracy (RE) was -1.3% to 5.7% at all QC levels. The method was applicable to clinical pharmacokinetic study of azithromycin in healthy volunteers following oral administration.  相似文献   

17.
A sensitive high-performance liquid chromatography method coupled to UV and single mass spectrometry (MS) detection was developed for the determination of tenofovir in human plasma. A solid phase extraction procedure (Bond-Elut C18 Varian cartridges) provided high extraction efficiency (91% for tenofovir and 68.8% for the internal standard, 3-methylcytidine). An atlantis-dC-18 analytical column is used with an isocratic mode elution of a mixture (pH 2.5) of ammonium acetate/methanol (98.5:1.5, v/v). Detection was performed at 260 nm and by using the ion at m/z 288. The signals from both detectors were validated over the range of 10-1000 ng mL(-1) and were found to be linear, accurate and precise. At the lowest limit of quantification, 10 ng mL(-1) for UV and 5 ng mL(-1) for MS, the average coefficient of variation was 6.9 and 3.9%, respectively. To investigate the potential of the validated method for clinical studies, more than 170 samples from HIV-infected adult patients were then analyzed with this assay. A good correlation was observed between the results obtained with both detectors. However, in several cases discordant results were observed between UV and MS detections. Therefore, tenofovir can sometimes suffer from interferences using either UV or single MS detection. We concluded that the double detection allows to obtain a more specific quantification of tenofovir. The present assay is sound and can be used for therapeutic drug monitoring allowing a higher reliability of the results which are transmitted to the medical team.  相似文献   

18.
A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method for the determination of scutellarin in human plasma has been developed. Samples were prepared using solid phase extraction and analyzed on a C(18) column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of methanol-water (0.1% formic acid), using gradient procedure. The analyte and internal standard baicalin were both detected by use of selected reaction monitoring mode. The method was linear in the concentration range of 0.2-20.0 ng/mL. The lower limit of quantification (LLOQ) was 0.2 ng/mL. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 12.4%. The accuracy determined at three concentrations (1.0, 5.0 and 10.0 ng/mL for scutellarin) was within +/-5.0% in terms of relative error. The method herein described was successfully applied for the evaluation of pharmacokinetic profiles of scutellarin guttate pills in 20 healthy volunteers.  相似文献   

19.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

20.
A LC–MS/MS method was developed and validated for the determination of dehydroandrographolide succinate (DAS), a traditional Chinese medicine derivative used for the treatment of pneumonia, upper respiratory tract infection, and chronic bronchitis. Following protein precipitation, DAS was detected by ion transition at m/z 531.2/99.0 in multiple reaction monitoring mode with negative electrospray ionization-tandem mass spectrometry. The limit of detection was 0.5 ng/mL, and the lower limit of quantification was 10 ng/mL in human plasma. Good linearity was maintained over the range of 10–5000 ng/mL, and the correlation coefficient was better than 0.99. The accuracy ranged from 95.3% to 113%, RSD from 0.928% to 6.47%, for the within- and between-run analysis at all QC levels. The recovery ranged from 85.5% to 93.4% and the matrix effect from 107% to 119%. No significant carryover and good stability were found during method validation. The developed method was successfully applied to the determination of DAS in human plasma in a pharmacokinetic study following intravenous infusion of potassium sodium DAS to nine healthy volunteers.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号