 共查询到20条相似文献,搜索用时 29 毫秒
1.
An automated online sample extraction method for rat plasma was developed and validated for the quantification of (R)- and (S)-propranolol following the intravenous administration of either the racemate or the individual enantiomers at 5 mg/kg. A dual-column extraction system coupled to a chiral stationary phase (CSP) was used in conjunction with liquid chromatography-tandem mass spectrometry. In this method, two Oasis HLB extraction columns (50x1.0 mm) in parallel were used for online plasma sample purification and teicoplanin CSP (Chirobiotic T) was used for the enantiomeric separation. This method allowed the use of one of the extraction columns for purification while the other was being equilibrated. Hence, the time required for re-conditioning the extraction columns did not contribute to the total analysis time per sample, which resulted in a relatively shorter run time and higher throughput. The lower limit of detection was 0.5 ng/ml and the lower limit of quantification was 2 ng/ml for each enantiomer using 25 microl of rat plasma. The method was validated with a linear calibration curve between 2 and 2000 ng/ml for (R)- and (S)-propranolol, respectively. The intra- and inter-day precision (C.V.) was no more than 7.6% and the accuracy of the assay was between 92 and 103%. The teicoplanin CSP proved to be rugged with excellent reproducibility of chromatographic parameters.  相似文献   

2.
Introduction – Biflavones of Hypericum perforatum L. are bioactive compounds used in the treatment of inflammation and depression. Determination of amentoflavone and biapigenin from blood is challenging owing to their similar structures and low concentrations. Objective – To develop a rapid, sensitive and accurate method based on liquid‐phase extraction followed by high‐performance liquid chromatography and electrospray ionisation mass spectrometry (HPLC‐ESI‐MS) for quantification of biflavones in human plasma. Methodology – After extraction from blood, the analytes were subjected to HPLC with an XTerra® MS C18 column and a binary mobile phase consisting of 2% formic acid in water and acetonitrile under isocratic elution conditions, with ESI‐MS detection in the negative ion mode and multiple reaction monitoring (MRM). Results – Both calibration curves showed good linearity within the concentration range 1–500 ng/mL. Limits of detection (S/N = 3) were 0.1 ng for pure substances and the limits of quantitation (S/N = 5) were 1.0 ng/mL from analyte‐spiked serum. The grand mean recovery was 90% from several subsamples of each biflavone. The imprecision (RSD) of peak areas was between 5% (intraday) and 10% (interday) for high concentrations (250 ng/mL) and between 10% (intraday) and 15% (interday) for low concentrations (1 ng/mL). Inaccuracy of the mean was less than 20% at the lower limit of quantitation. Conclusion – The developed and validated method for determination of biflavones from human plasma was effectively applied to pharmacokinetic studies of 13 probands and preliminary results indicate biphasic concentration–time curves. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

3.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

4.
A fast, sensitive, and enantioselective LC-MS/MS bioanalytical method was developed and validated for the direct determination of individual alprenolol enantiomers in human plasma using cellobiohydrolase (CBH) chiral stationary phases (CSP) along with supported liquid extraction (SLE) procedures. Complete baseline separation of enantiomeric alprenolol was achieved within 2 min in reversed phase chromatography at 0.9 ml/min. SLE in a 96-well plate format was used for sample extraction. The method validation was conducted over the curve range of 0.500-500 ng/ml for each alprenolol enantiomer using 0.0500 ml of plasma sample. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels showed < or = 7.3% relative standard deviation (RSD) and -6.2 to 8.0% relative error (RE) for both alprenolol enantiomers.  相似文献   

5.
A quantitative analytical method using automated on-line solid phase extraction (SPE) and liquid chromatography-electrospray tandem mass spectrometry (LC-ESI-MS/MS) for the determination of 8-OHdG (8-hydroxy-2'-deoxyguanosine) in human plasma was developed and validated. A one-step membrane extraction method for the plasma sample preparation and a C18 SPE column with simple extraction and purification were used for the on-line extraction. A C18 column was employed for LC separation and ESI-MS/MS was utilized for detection. (15)N(5)-8-OHdG ((15)N(5)-8-hydroxy-2'-deoxyguanosine) was used as an internal standard for quantitative determination. The extraction, clean-up and analysis procedures were controlled by a fully automated six-port switch valve as one strategy to reduce the matrix effect and simultaneously improve detection sensitivity. Identification and quantification were based on the following transitions: m/z 284→168 for 8-OHdG and m/z 289→173 for (15)N(5)-8-OHdG. Satisfactory recovery was obtained, and the recovery ranged from 95.1 to 106.1% at trace levels in human plasma and urine, with a CV lower than 5.4%. Values for intraday and interday precision were between 2.3 and 6.8% for plasma and between 2.7 and 4.5% for urine, respectively. Values for the method accuracy of intraday and interday assays ranged from 93.0 and 100.5% for plasma and 110.2 and 119.4% for urine, respectively. The limits of detection (LOD) and LOQ were 0.008 ng/mL and 0.02 ng/mL, respectively.The applicability of this newly developed method was demonstrated by analysis of human plasma samples for an evaluation of the future risk of oxidative stress status in human exposure to nanoparticles and other diseases.  相似文献   

6.
A sensitive method for the determination of Cloretazine (VNP40101M) and its metabolite (VNP4090CE) with an internal standard (ISTD) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Acidified plasma samples (500 microL) were prepared using solid phase extraction (SPE) columns, and 25 microL of the reconstituted sample was injected onto an Ascentis C18 HPLC column (3 microm, 5 cmx2.1 mm) with an isocratic mobile phase. Analytes were detected with an API-3000 LC-MS/MS System at unit (Q1) and low (Q3) resolution in negative multiple reaction monitoring mode: m/z 249.0 (precursor ion) to m/z 114.9 (product ion) for both Cloretazine (at 3.64 min) and VNP4090CE (at 2.91 min), and m/z 253.0 (precursor ion) to m/z 116.9 (product ion) for the ISTD. The mean recovery for Cloretazine (VNP40101M) and its metabolite (VNP4090CE) was greater than 87% with a lower limit of quantification of 1.0 ng/mL for Cloretazine (S/N=9.7, CV相似文献   

7.
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for simultaneous determination of the prodrug fosinopril and its major active metabolite fosinoprilat for pharmacokinetic studies in healthy subjects. In order to get the lower limit of quantification (LLOQ), especially for analysis of fosinopril, key points of the method have been investigated including chromatographic conditions and selection of LC-MS/MS conditions. The analytes were extracted from plasma samples by liquid-liquid extraction, separated on a reversed-phase C(8) column using gradient procedure, and detected by tandem mass spectrometry with a triple quadrupole ionization interface. The analytes and internal standard zaleplon were detected using positive electrospray ionization (ESI) in the SRM mode. The LLOQ of the method down to 0.1 ng mL(-1) for fosinopril and 1.0 ng mL(-1) for fosinoprilat were identifiable and reproducible. The standard calibration curves for both fosinopril and fosinoprilat were linear over the ranges of 0.1-15.0 and 1.0-700 ng mL(-1) in human plasma, respectively. The within- and between-batch precisions (relative standard deviation (RSD)%) and the accuracy were acceptable. The validated method was successfully applied to reveal the pharmacokinetic properties of fosinopril and fosinoprilat after oral administration.  相似文献   

8.
Sensitive and selective methods based on high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection were developed for the determination of vitamin D(3) in human serum. Derivatization of vitamin D(3) and its stable isotope labeled internal standard provided highly sensitive quantification and selective detection from endogenous compounds. Samples were prepared using the in-tube liquid-liquid extraction (LLE), 96-well plate LLE, and in-tip solid phase micro-extraction (SPME) in 96-well format. In all methods, the MS/MS detection was performed using Applied Biosystems-Sciex API 3000 tandem mass spectrometers interfaced with a heated nebulizer probe and operated in the positive ionization mode. Both tube and plate LLE methods achieved a lower limit of quantitation (LLOQ) of 0.5 ng/mL when 1.0 and 0.4 mL of human serum was processed, respectively, and were validated in the concentration range of 0.5-25 ng/mL; while for the in-tip SPME method, LLOQ was 5 ng/mL with only 0.1 mL of human serum required. Comparisons were made among three different methods, including precision and accuracy, sample throughput, recovery and matrix effects.  相似文献   

9.
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.  相似文献   

10.
Ultra-high pressure liquid chromatography (UHPLC) is a relatively new technology which utilizes chromatographic media with a 1.7 microm particle size. This technology has the potential to offer significant advantages in resolution, speed, and sensitivity for analytical determinations, particularly when coupled with mass spectrometric detection. Drug Candidate A, under development at Merck Research Laboratories, contains two chiral centers which have the absolute configuration R, S. Under in vivo and ex vivo conditions, one of the chiral centers readily epimerizes to produce the R, R diastereomer. Initially, a traditional high performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) method was developed to separate and quantify these two diastereomers in rat plasma. The lower limit of quantification (LOQ) of the two analytes was 2 ng/mL, and a chromatographic run time of approximately 11 min was needed to separate R, S-(A) and R, R-(A). In this study, we explored a simple and robust UHPLC-MS/MS method in order to increase sample throughput and productivity. We were able to achieve a two-fold reduction in the lower limit of quantification and a three-fold reduction in retention time utilizing the UHPLC method, while keeping the same sample extraction procedure and similar MS/MS methodology. The new method exhibited good intra- and inter-day accuracy and precision, and was linear over a dynamic range of 1-500 ng/mL for each diastereomer. The method was successfully applied for the determination of R, S-(A) and R, R-(A) concentrations for in vitro and in vivo studies of epimerization of A in Sprague-Dawley rats.  相似文献   

11.
Echinacea purpurea is one of the most popular herbal medicines and is known for its immunostimulatory effects. Alkylamides are the main lipophilic components of E. purpurea that contribute to its pharmacological actions. For quantification in human plasma of one of these alkylamides, undeca-2-ene-8,10-diynoic acid isobutylamide, a sensitive LC-MS/MS assay has been developed and validated. Plasma samples were pretreated using liquid-liquid extraction with a mixture of diethyl ether and n-hexane (50:50, v/v). Dried extracts were reconstituted in 50 μL of acetonitrile-water (50:50, v/v) after which 15 μL of sample was injected into the HPLC system. HPLC was performed using a Polaris 3 C18-A column (50 mm×2 mm ID) and isocratic elution with acetonitrile-water (50:50, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. Subsequently, electrospray ionization in the positive ion mode followed by tandem mass spectrometry was performed for detection. The total run time was 3 min. The assay was validated over a concentration range from 0.05 to 50 ng/mL for undeca-2-ene-8,10-diynoic acid isobutylamide, with 0.05 ng/mL being the lower limit of quantification using 1.0 mL plasma samples. Inter-assay inaccuracy (±12.7%), within-day and between-day precisions (CV≤8.23%) were acceptable. Further, undeca-2-ene-8,10-diynoic acid isobutylamide was found to be chemically stable under relevant conditions. Finally, the applicability of this assay has been successfully demonstrated in a pharmacokinetic experiment in which a human volunteer ingested a commercial extract of E. purpurea.  相似文献   

12.
A selective and sensitive method for the simultaneous determination of hypericin and hyperforin--the two main active ingredients of St. John's Wort (SJW) extract--in human plasma depending on liquid/liquid-extraction and LC/MS/MS detection has been developed, validated after specifying the stability of the photosensitive hypericin in plasma samples during light exposure and applied to samples of a patient. After extraction with ethyl acetate/n-hexane in the darkness, sample extracts were chromatographed isocratically within 6 min on a Kromasil RP-18 column. The analytes were detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source. The limit of quantification was 0.05 ng/mL for hypericin and 0.035 ng/mL for hyperforin. The accuracy of the method varied between 101.9 and 114.2% and the precision ranged from 4.7 to 15.4% (S.D., batch-to-batch) for both analytes. The method was linear at least between 0.05 and 10 ng/mL for hypericin and between 0.035 and 100 ng/mL for hyperforin. Using this method hypericin and hyperforin were determined successfully in a patient over seven days following discontinuation of exposure with therapeutic doses of St. John's Wort extract.  相似文献   

13.
A sensitive liquid chromatography-mass spectrometric (LC/MS) method for the quantification of schizandrin in rat plasma was developed and validated after solid-phase extraction (SPE). Chromatographic separation was achieved on a reversed-phase Shimadzu C(18) column with the mobile phase of acetonitrile-sodium acetate (10 micromol/L) and step gradient elution resulted in a total run time of about 11.7 min. The analytes were detected using an electrospray positive ionization mass spectrometry in the selected ion monitoring (SIM) mode. A good linear relationship was obtained in the concentration range studied (0.005-2.000 microg/mL) (r=0.9999). Lower limit of quantification (LLOQ) was 5 ng/mL and the lower limit of detection (LLOD) was 2 ng/mL using 100 microL plasma sample. Average recoveries ranged from 75.85 to 88.51% in plasma at the concentrations of 0.005, 0.100 and 1.000 microg/mL. Intra- and inter-day relative standard deviations were 5.95-12.93% and 3.87-14.53%, respectively. This method was successfully applied for the pharmacokinetic studies in rats.  相似文献   

14.
A sensitive and rapid LC-MS/MS method was developed and validated for the determination of levamisole in human plasma. The assay was based on liquid-liquid extraction of analytes from human plasma with ethyl ether. Chromatographic separation was carried on an Agilent HC-C(8) column (150 mm × 4.6 mm, 5 μm) at 40°C, with a mobile phase consisting of acetonitrile-10 mM ammonium acetate (70:30, v/v), a flow rate of 0.5 mL/min and a total run time of 6 min. Detection and quantification were performed by mass spectrometry in the multiple reaction monitoring mode with positive electrospray ionization m/z at 205.1→178.2 for levamisole, and m/z 296.1→264.1 for mebendazole (internal standard). The assay was linear over a concentration range of 0.1-30 ng/mL with a lower limit of quantification of 0.1 ng/mL. The coefficient of variation of the assay precision was less than 8.5%. The assay was successfully used to analyze human plasma samples in a pharmacokinetic study where levamisole was administered as a liniment.  相似文献   

15.
A LC-MS/MS method was validated for the determination of BA011FZ041, a styrylquinoline derivative. After addition of BA011FZ055 as internal standard (IS), the method involved solid phase extraction (SPE), LC separation with an ether-phenyl column and quantification by MS/MS after positive ESI. The calibration curve, ranging from 1 to 500 ng/mL was fitted to a 1/x-weighted quadratic regression model. Lower limit of quantification (LLOQ) was 1 ng/mL using 100 microL of plasma. Intra- and inter-assay precision and accuracy values were within the regulatory limits. The method was successfully applied to the determination of BA011FZ041 in rat plasma and PBMCs after i.v. dosing.  相似文献   

16.
The predominant circulating folate monoglutamate in human plasma (>90%), and thus the most significant folate for accurately diagnosing folate deficiency, is 5-methyltetrahydrofolic acid (5 MT). Folate deficiency is typically indicated when circulating folate levels are < or = 3 ng/mL. The quantitative determination of plasma folates in general, and of 5 MT in particular, is complicated by their naturally low levels (pg/mL to ng/mL), their instability, and their tendency to interconvert. Highly specific and sensitive analytical methods are needed to accurately quantify endogenous 5 MT in human plasma. A method that utilizes the specific high-affinity binding sites of bovine folate binding protein (FBP) and the selectivity and sensitivity of selected ion monitoring mode isotope-dilution liquid chromatography/mass spectrometry (LC/MS) to quantify plasma 5 MT has been developed. The method is based on the solid-phase affinity extraction (SPAE) of 5 MT and its stable isotopically labeled analogue ([13C(5)]5 MT) from plasma (1 mL) using FBP immobilized to polymeric beads. The excess high-affinity binding sites on the affinity columns enable quantitative extraction of 5 MT from plasma under optimized sample pH conditions. Additionally, it is demonstrated that plasma proteins do not hinder the determination of 5 MT; therefore, protein precipitation is not required before the affinity extraction step. Detection and quantification of the extracted 5 MT is provided by positive-ion mode LC/MS in which the protonated molecular ions [M+H](+) of the analyte and the internal standard are monitored. The method shows linearity over three orders of magnitude (0.04-40 ng/mL) and has limits of detection and quantification of 0.04 and 0.4 ng/mL, respectively. Calibration curves obtained by spiking 5 MT into plasma exhibited good linearity between 0 and 25 ng/mL and both the plasma calibration standards and the plasma samples were stable for at least 48 h at room temperature. The recovery (average +/- % RSD) of 5 MT spiked into plasma from 5 to 25 ng/mL was 98.0% +/- 1.6% (n = 15). 5 MT levels determined by SPAE-LC/MS compared to "total folate" levels determined by radioassay and microbiological assay were discordant. Reasons for the discordancy are theorized, but it is clear that there exists an urgent need for clinical reference materials containing certified folate levels.  相似文献   

17.
Nifedipine (NIF), a calcium channel antagonist, is metabolized primarily by cytochrome P450 (CYP3A4) to dehydronifedipine (DNIF). As such, NIF is often used as a probe drug for determining CYP3A4 activity in human studies. A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated to simultaneously determine NIF and DNIF in human plasma using nitrendipine as the internal standard (IS). After extraction of the plasma samples by ether-n-hexane (3:1, v/v), NIF, DNIF and the IS were subjected to LC/MS/MS analysis using electro-spray ionization (ESI). Chromatographic separation was performed on a Hypersil BDS C(18) column (50 mm x 2.1 mm, i.d., 3 microm). The method had a chromatographic running time of approximately 2.5 min and linear calibration curves over the concentrations of 0.5-100 ng/mL for NIF and DNIF. The recoveries of the one-step liquid extraction method were 81.3-89.1% for NIF and 71.6-80.4% for DNIF. The lower limit of quantification (LLOQ) of the analytical method was 0.5 ng/mL for both analytes. The intra- and inter-day precision was less than 15% for all quality control samples at concentrations of 2, 10, and 50 ng/mL. The validated LC/MS/MS method has been successfully used to study pharmacokinetic interactions of NIF with the herbal antidepressant St. John's wort in healthy volunteers. These results indicated that the developed LC/MS/MS method was efficient with a significantly shorter running time (2.5 min) for NIF and DNIF compared to those methods previously reported in the literature. The presented LC/MS/MS method had acceptable accuracy, precision and sensitivity and was used in a clinical pharmacokinetic interaction study of NIF with St. John's wort, a known herbal inducer of CYP3A4. St. John's wort was shown to induce NIF metabolism with increased plasma concentrations of DNIF.  相似文献   

18.
A sensitive method for the determination of lapatinib (GW572016) in human plasma was developed using high-performance liquid chromatographic separation with tandem mass spectrometric detection. Plasma samples (100 microL) were prepared using solid phase extraction (SPE) columns, and 6.0 microL of the reconstituted eluate was injected onto a Phenomenex CuroSil-PFP 3 mu analytical column (50 mm x 2.0mm) with an isocratic mobile phase. Analytes were detected with a PE SCIEX API-365 LC-MS/MS system at unit (Q1) and low (Q3) resolution in positive multiple reaction monitoring mode (m/z 581 (precursor ion) to m/z 364 (product ion) for lapatinib). The mean recovery for lapatinib was 75% with a lower limit of quantification of 15 ng/mL (S/N=11.3, CV< or =14%). This method was validated over a linear range of 100-10,000 ng/mL, and results from a 5-day validation study demonstrated good within-day and between-day precision and accuracy. This method has been used to measure plasma lapatinib concentrations in a Phase I study in children with cancer.  相似文献   

19.
A sensitive and enantioselective vancomycin chiral stationary phase high‐performance liquid chromatography–tandem mass spectrometry method was developed for the determination of trantinterol enantiomers in human plasma. Baseline resolution was achieved using the vancomycin chiral stationary phase known as Chirobiotic V with polar ionic mobile phase consisting of acetonitrile–methanol (60:40, v/v) containing 0.01% ammonia and 0.02% acetic acid at a flow rate of 1.0 mL/min. Waters Oasis HLB C18 solid phase extraction cartridges were used in the sample preparation of trantinterol samples from plasma. The detection was performed on a triple‐quadrupole tandem mass spectrometer by multiple reaction monitoring mode via electrospray ionization. The calibration curve was linear in a concentration range from 0.0606 to 30.3 ng/mL in plasma, with the lower limit of quantification of 0.0606 ng/mL. The intra‐ and interday precision (relative standard deviation) values were within 9.7% and the accuracy (relative error) was from ?6.6 to 7.2% at all quality control levels. The method was successfully applied to a study of stereoselective pharmacokinetics in human. Chirality 27:327–331, 2015.© 2015 Wiley Periodicals, Inc.  相似文献   

20.
Glycyrrhizin (GLY) which has been widely used in traditional Chinese medicinal preparation possesses various pharmacological effects. In order to investigate the pharmacokinetic behavior of GLY in human after oral administration of GLY or licorice root, a liquid chromatography/tandem mass spectrometry (LC-MS/MS) method was developed and validated for the simultaneous determination of GLY and its major metabolite glycyrrhetic acid (GA) in human plasma. The method involved a solid phase extraction of GLY, GA, and alpha-hederin, the internal standard (IS), from plasma with Waters Oasis MCX solid phase extraction (SPE) cartridges (30 mg) and a detection using a Micromass Quattro LC liquid chromatography/tandem mass spectrometry system with electrospray ionization source in positive ion mode. Separation of the analytes was achieved within 5min on a SepaxHP CN analytical column with a mobile phase of acetonitrile:water (50:50, v:v) containing 0.1% formic acid and 5mM ammonium acetate. Multiple reaction monitoring (MRM) was utilized for the detection monitoring 823--> 453 for GLY, 471--> 177 for GA and 752--> 456 for IS. The LC-MS/MS method was validated for specificity, sensitivity, accuracy, precision, and calibration function. The assay had a calibration range from 10 to 10,000 ng/mL and a lower limit of quantification of 10 ng/mL for both GLY and GA when 0.2 mL plasma was used for extraction. The percent coefficient of variation for accuracy and precision (inter-run and intra-run) for this method was less than 11.0% with a %Nominal ranging from 87.6 to 106.4% for GLY and 93.7 to 107.8% for GA. Stability of the analytes over sample processing (freeze/thaw, bench-top and long-term storage) and in the extracted samples was also tested and established.  相似文献   