The chromogenic substrate Limulus amebocyte lysate (LAL) assay method for the detection of endotoxin was automated by a Zymate robotic system. The software developed enables the robot to automatically dilute a stock reference endotoxin standard (20,000 endotoxin units per ml) for the construction of a five-point standard curve, make sample dilutions to the proper testing concentration, and perform chromogenic substrate LAL assays in duplicate. The linearity of the standard curve and the endotoxin concentration in each sample are calculated and results are printed automatically. In 48 min the automated system assays three samples and a reference standard in duplicate along with a water blank. Sensitivity of the assay is a function of incubation time. The assay is linear (r greater than 0.99) in the region of 0 to 1.0 endotoxin units per ml or 0 to 0.2 endotoxin units per ml with incubation times of 10 or 16 min, respectively. The method can be made very sensitive, detecting as low as 0.003 endotoxin units per ml with 30 min of incubation. The precision of the assay method, determined by assaying an endotoxin reference solution eight times, is ca. 6%. The LAL reagent designed for gel-clot assay was modified for the chromogenic substrate assay. We describe the optimum conditions for the performance of the chromogenic substrate LAL assay and stability of the LAL reagent.  相似文献   

2.
Here, we report the development of an electrochemical detection method for endotoxin based on the Limulus amebocyte lysate (LAL) assay. A mixture of LAL reagent and endotoxin sample solution was incubated for 1 h. The endotoxin activated a cascade reaction of zymogens contained in the LAL to generate p-nitroaniline (pNA) which was then electrochemically detected by differential pulse voltammetry (DPV). The generated pNA gave a clear peak at -0.75 V vs. silver/silver chloride (Ag/AgCl), which increased with the concentration of endotoxin in the LAL assay solution. This DPV detection was performed using an electrode chip device fabricated from a diamond-like carbon-coated glass substrate. This chip device could detect as low as 10 endotoxin units l(-1) at room temperature within 1 h. This novel electrochemical method for the detection of endotoxin appears promising for the development of compact, low-cost and easy-to-use sensors for on-site monitoring of potentially contaminated medical supplies, including dialysis fluid, transplanted tissue and culture medium for assisted reproduction.  相似文献   

3.
The rabbit pyrogen test and Limulus amoebocyte lysate (LAL) assay have been used to detect endotoxins in vaccines, but interactions between the endotoxins and proteins or aluminum hydroxide can interfere with the results. Currently, the rabbit pyrogen test is used to detect endotoxin in hepatitis B (HB) vaccines even though the HB surface protein, the active ingredient, is over-expressed in and purified from eukaryotic cells which lack endotoxin. Therefore, we examined the possibility of replacing the animal tests with the more efficient LAL test. To this end, we determined whether the aluminum hydroxide in the HB vaccines affects the rabbit pyrogen test and the LAL assay. HB vaccines and HB protein solutions spiked with lipopolysaccharide (LPS) produced almost the same dose-dependent temperature rise in rabbits, indicating that the aluminum hydroxide in the HB vaccine does not interfere with the pyrogenic response in rabbit. In contrast, a spike recovery study showed that aluminum hydroxide interfered with the LAL clot and kinetic assays; however, the LAL clot assay was effective at detecting endotoxin without loss of LAL activity after serial dilution of the samples. Furthermore, there was good correlation in the LAL clot assay between the amount of LPS added and the amount recovered. However, both turbidimetric and chromogenic kinetic assays displayed no correlation between the LPS amount added and recovered. Our results suggest that the LAL clot assay is sensitive and reliable when samples are properly prepared, and can be used to replace the rabbit pyrogen test for the detection of endotoxin in HB vaccines.  相似文献   

4.
We developed a simple new endotoxin-specific assay method that uses Limulus amebocyte lysate (LAL) containing a sufficient amount of a water-soluble (1----3)-beta-D-glucan derivative as a blocker of the (1----3)-beta-D-glucan-mediated coagulation pathway. The addition of 0.1 mg/ml or more of carboxymethylated (1----3)-beta-D-glucan completely blocked the activation of LAL by (1----3)-beta-D-glucan itself. The assay of endotoxin was unaffected by the presence of 1 mg/ml carboxymethylated (1----3)-beta-D-glucan. Spiked endotoxin was recovered well from beta-glucans by the turbidimetric kinetic method with LAL containing 1 mg/ml of carboxymethylated (1----3)-beta-D-glucan. Besides, this new LAL formulation was applied for an endotoxin-specific assay by the conventional gel-clot method or the chromogenic method. Gram-negative bacteria were specifically detected by the turbidimetric kinetic method with the LAL formulation. This LAL formulation may be used for an endotoxin-specific assay not only in pharmacology but also in clinical microbiology.  相似文献   

5.
The gelation of standard Limulus amoebocyte lysate (LAL) is triggered by the addition of a small amount of beta-glucan (1-1000 ng/ml plasma), but in the presence of an excessive amount of beta-glucan (1 mg/ml plasma), the gelation becomes insensitive to beta-glucan. Utilizing this property, a method to determine quantitatively the amount of endotoxin circulating in humans was developed. When a modified LAL, or LAL-ES, which contains an excessive amount of CM-curdlan as beta-glucan, was used for the assay, a linear relation in the logarithmic scales was obtained between the gelation time measured by the turbidimetry (min) and the concentration of endotoxin. This relation was not affected by a considerable amount of beta-glucan (100 ng/ml). The sensitivity of the endotoxin assay was estimated to be as low as 3 pg/ml. The following aspects of the method were found by clinical application to normal and febrile subjects. (1) Using both LAL and LAL-ES, it was possible to distinguish the effect of endotoxin from that of beta-glucan in plasma, i.e., bacterial sepsis from fungal sepsis. (2) The amount of circulating endotoxin determined by the present method showed good correlation to those obtained by chromogenic assay using modified LAL devoid of Factor G which could be activated by beta-glucan.  相似文献   

6.
A convenient kinetic chomogenic Limulus amoebocyte lysate (LAL) method, based on components originally intended for a two-stage end-point method, has been developed. The components (LAL and chromogenic substrate) can be pooled and subsequently used in a single-stage kinetic procedure adapted to microplates. With the help of a kinetic software, it is possible to measure over the three log range 0.005–12 EU/ml in one test run — a range considerably wider than the range of the end-point procedure. A good linearity of log-log standard curve, reflected by coefficients of regression between 0.997 and 1.0, is shown as well as high-resolution (> 700 s) between the negative control and the lowest standard point. Moreover a good precision (C.V.<10%) is obtained in both water and plasma, showing the usefulness of the method in different applications. Finally, a strong correlation (4 = 0.95–0.99) to other LAL methods is demonstrated.  相似文献   

7.
A chromogenic Limulus amoebocyte lysate (LAL) endpoint assay was found to be an accurate and rapid means of gauging levels of beef carcass microbial contamination within 10 min. The assay demonstrated a high correlation with the total mesophilic bacterial and coliform surface populations from inoculated beef carcass surface tissues. This assay was tested on a set of actual beef carcass surface samples (n = 121) demonstrating the utility of the chromogenic LAL test as a means of monitoring carcass microbial contamination in a near real-time fashion. Classifying the chromogenic LAL results into four contamination groups was found to be a sound means of utilizing the resultant chromogenic LAL data for detecting carcasses with high levels of microbial contamination. For beef carcass testing, this assay can be used with no instrumentation other than the required 37 degrees C incubator and, as an option, a microplate reader.  相似文献   

8.
显色基质鲎试剂法在人血白蛋白热原检测中的应用   总被引:1,自引:0,他引:1  
为了对显色基质法测定人血白蛋白中的内毒素含量方法进行探讨。以内毒素,鲎试剂及显色基质,在一定的条件下反应释放出对硝基苯胺(PNA),溶液呈现黄色,于波长545nm处比色读数,其产色深浅与内毒素浓度呈线性关系,从而定量测定出检品中内毒素含量。结果表明标准曲线的线性相关系数r≥0.98,人血白蛋白经3.3倍稀释后无干扰作用。显色基质法与家兔法比较,有灵敏、快速、能定量、重复性好的特点,可用于人血白蛋白内毒素含量的测定。  相似文献   

9.
The bacterial endotoxins test (BET) is the most sensitive assay for measuring endotoxin levels in solution. However, it is difficult to quantify endotoxin levels in some solutions because unknown interfering factors may inhibit or enhance the Limulus amebocyte lysate (LAL) coagulation reaction. We investigated the mechanisms of this interference and found that interference can be reduced or totally suppressed by preparing sample solutions in saline, Dulbecco’s phosphate-buffered saline (D-PBS), N,N-bis-(2-hydroxyethyl)-2-aminoethanesulfonic acid (BES), or 2-amino-2-hydroxymethyl-1,3-propanediol (Tris) buffers. We examined the inhibitory effect on the interfering action of various reagents. The reagents examined were classified into two groups: a weak interference and a strong interference group. The interference of the strong interference group was suppressed by adding endotoxin and the test factors to LAL individually. Endotoxin peaks analyzed by gel-filtration HPLC disappeared in the presence of interfering factors. When buffers were used to prepare sample solutions instead of water, endotoxin peaks were maintained and interference with LAL reaction was suppressed. These results indicate that for the strong interference group, interference of the LAL reaction was a direct consequence of interfering factors binding to endotoxin. This alters endotoxin complexation, but this effect may be suppressed by preparing solutions in saline or other buffers instead of in water.  相似文献   

10.
Increased sensitivity of the Limulus amoebocyte lysate (LAL) assay for the detection of endotoxin was attained by the reconstitution of commercially available LAL reagent with a magnesium-containing solution. As little as 2 to 6 pg (0.002 to 0.006 ng) of Escherichia coli O127:B8 endotoxin per ml was detected, an increase in sensitivity of 10 to 30 times. The optimum magnesium concentration range for the LAL reagent used and the optimum pH range were approximately 50 to 65 mM and pH 6.0 to 8.0, respectively. Reconstitution of five commercially available brands of LAL with a solution containing magnesium resulted in greater assay sensitivity than the identical LAL reconstituted with pyrogen-free water. Use of LAL reconstituted with a solution containing magnesium is crucial for the assay of some parenteral products, wherein increased sensitivity is essential to meet the requirement for the maximum valid dilution criteria. The mode of action of magnesium for enhanced sensitivity of LAL has been postulated.  相似文献   

11.
Five different intravenous IgG (i.v. IgG) preparations were assessed for their capacity to modify the pyrogenic response to bacterial lipopolysaccharide (LPS) of rabbits under the conditions of a pharmacopoeal test. Four of the five preparations were found to mitigate the reaction rendering the result "non-pyrogenic" with an LPS dose proved pyrogenic when administered in saline or in albumin. Bacterial LPS was found readily detectable by a simple Limulus amoebocyte lysate (LAL) gelation test. Four of six brands of i.v. IgG were found reactive in the test under conditions adjusted to detect the FDA limit. The reaction obtained upon addition of standard LPS to the negative preparations supported the validity of the assay. The LAL reactivity of two of the reactive preparations was inhibited by laminarin, a compound known to inhibit Limulus lysate gelation by beta-D-glucan, but not by Polymyxin B. Specific detection of bacterial endotoxins in i.v. IgG solutions requires inhibition of the beta-D-glucan pathway of the Limulus lysate coagulation. Using an appropriate inhibitor, the LAL gelation test is suitable to detect a potential endotoxin contamination in i.v. IgG which might have not been unravelled by the in vivo test for pyrogens.  相似文献   

12.
采用鲎试剂法检测重组 (CHO细胞 )乙型肝炎疫苗中的细菌内毒素含量 ,研究了甲醛、硫柳汞、氢氧化铝等疫苗成分对鲎试剂试验的影响。结果表明 ,疫苗中各成分对检测未见影响 ,所以检测本疫苗中内毒素含量时 ,采用鲎试剂法是可行的。同时 ,用此试验方法对本室所生产的重组 (CHO细胞 )乙型肝炎疫苗进行了检测 ,疫苗中内毒素含量全部合格  相似文献   

13.
Incorporation of lipopolysaccharide (LPS) into liposomes dramatically reduces its ability to coagulateLimulusamebocyte lysate (LAL). The coagulation of LAL is commonly used to signal the presence of endotoxinin vitro.This study demonstrates a simple method to release masked endotoxin from liposomal dispersions using moderate amounts of detergent to form mixed micelles containing lipid, detergent, and LPS. Several parameters were found to affect the degree of liposome solubilization and/or the sensitivity of the LAL assay. These included detergent type and concentration, temperature for solubilization, lipid composition, liposome morphology, and time for test incubation. The nonionic detergent polyoxyethylene 10 lauryl ether (C12E10) proved to be unique in its ability to solubilize liposomes and minimally interfere with endotoxin detection. The LAL endotoxin detection limit for samples dispersed in C12E10varied with the phospholipid component; the sensitivity decreased in the order DSPC > DPPC = EPC DMPC. Cholesterol lowered the solubility limit of the liposomes, but did not appear to affect the LAL assay sensitivity once the liposomes were completely solubilized. The presence of negatively charged phospholipids, DSPG and Pops, also lowered the solubility limit. Pops, but not DSPG, at 10 mol% further decreased the LAL endotoxin detection limit. This detergent-solubilization method should be useful in liposomal LPS immunological studies or in other situations where accurate determination of endotoxin concentration is important.  相似文献   

14.
Recent new data on the important role played by lipopolysaccharides (endotoxin) of Gram negative bacteria in physiology and pathogenesis of the most important human infectious and noninfectious diseases testify to the necessity of wide clinical trials of different methods for LPS detection in blood and other physiological fluids. Among presently available diagnostic methods for endotoxinemia detection, the highly sensitive LAL (Limulus Amebocyte Lysate) test in various modifications is most widely used. The LAL test is known to be non-specific, however many drawbacks of this test have been successfully overcome. The results of clinical studies on the determination of the LPS activity in the systemic blood stream and antibody titers to its most common determinants, as well as the reserves of endotoxin binding with granulocytes give grounds for optimistic evaluation of the future studies on the role of LPS in human physiology and pathology. In clinical practice both positive sides and drawbacks of the presently known methods for LPS detection, including the LAL test, must be borne in mind for the complex evaluation of endotoxinemia levels.  相似文献   

15.
We developed a selective endotoxin (lipopolysaccharide; LPS) assay using poly(ε-lysine)-immobilized cellulose beads (PL-Cellufine) and Limulus amoebocyte lysate (LAL). First, LPS was selectively adsorbed on the beads in a solution containing various LAL-inhibiting or LAL-enhancing compounds (e.g., amino acids, enzymes) and the LPS adsorbed on the beads was separated from the compounds by centrifugation. Second, the LPS adsorbed on the beads directly reacted with the LAL reagent, and the LPS concentration was determined by a turbidimetric time assay. The accuracy of the adsorption method with PL-Cellufine was high compared with that of a common solution method. Apparent recovery of LPS from compound solution was 88-120%.  相似文献   

16.
The gelation of Limulus amebocyte lysate (LAL) evoked by bacterial endotoxins can be detected earlier than with usual methods by using laser scattering photometry to recognize the formation of small particles of clotted enzyme produced when the reaction mixture is agitated. The appearance of these small particles means that the influence of endotoxins has stimulated activation of the clotting enzyme across the LAL cascade, and the timing of their appearance is related to endotoxin concentration. This new method can be used for quick and sensitive endotoxin assay. The average endotoxin level of healthy volunteers was assayed to be 0.0738 pg/ml [0.0312-0.3445 pg/ml] (n = 11) within 70 min from the start of the assay.  相似文献   

17.
The measurement of airborne endotoxins is thus far not standardized. Earlier studies reported higher endotoxin yields when Tween 20 was added to the media used for filter extraction and in the Limulus amebocyte lysate (LAL) assay. This study compared four common media and assessed the effects of Tween during extraction and analysis separately. Parallel airborne dust samples from five work environments (n = 250) were used to compare the four media (pyrogen-free water [PFW], PFW-Tween 20, PFW-Tris, and PFW-triethylamine-phosphate [TAP]) and an extraction time of 10 or 60 min. A subset of the extracts in PFW or PFW-Tween (n = 40) were analyzed in parallel LAL assays with PFW or PFW-Tween as the assay medium. The results produced by a shorter extraction time or the presence of Tris were similar to the results for the reference procedure (PFW and 60 min of shaking). The use of PFW-TAP showed overall lower yields and a deviant calibration curve. The presence of Tween in the extraction medium resulted in significantly (P < 0.05) higher endotoxin yields from all dust types, independent of the effect of Tween in the assay. Tween in the LAL assay, however, also strongly inhibited the reactivity of the lipopolysaccharide (LPS) standard, thus shifting the calibration curve to higher values. The inhibition of LPS in test samples was less pronounced and varied between dust sources, resulting in enhanced calculated concentrations. This assay effect could be circumvented by diluting extracts at least 50-fold before the LAL assay. In conclusion, of the media tested, only Tween enhances the efficiency of endotoxin extraction from airborne dust samples in a consistent manner. We recommend extraction in PFW-Tween combined with dilution and LAL analysis in PFW.  相似文献   

18.
A fast and sensitive HPLC method using fluorescence detection is developed to quantitate 1-pyrenyldiazomethane (PDAM) derivatized fatty acids derived from the lipid components of both the capsular meningococcal polysaccharide and other impurities such as endotoxin in various meningococcal vaccine samples. The HPLC method is capable of well resolving 13 relevant fatty acids within 40min by using a multi-stage acetonitrile/water gradient. Endotoxin values measured by HPLC well correlated with results from the standard Limulus amebocyte lysate (LAL) assay. Furthermore, the fatty acid profiles of various process intermediate samples as well as final purified polysaccharide products were determined to better understand and characterize the purification process.  相似文献   

19.
This paper presents a rapid, highly-sensitive, and low-cost method of endotoxin quantification based on the use of stress-responsive magnetoelastic sensors, that monitor the gel formation (viscosity change) of the Limulus Amoebocyte Lysate (LAL) assay in response to endotoxin. Ribbon-like magnetoelastic sensors, 12.7 mm × 6 mm × 28 μm, were immersed in a LAL assay after mixing with test samples of variable endotoxin concentration, and the decrease in resonance amplitude of the sensor was recorded as a function of time. Experimental results show excellent correlation between endotoxin concentration and the maximum clot rate, determined by taking the minimum point of the first derivative of the amplitude–time curve, as well as the clotting-time, defined as the time that corresponds to the maximum clot rate. Using a LAL gel–clot assay with a sensitivity of 0.06 EU/ml (EU: endotoxin unit), the magnetoelastic sensor based technology can detect the presence of endotoxin at 0.0105 EU/ml in test requiring approximately 20 min. Unlike optical methods used for determining endotoxin concentration, the color of the test solution does not impact the magnetoelastic sensor measurement. Due to the small size of the sensor reader electronics and low cost, the magnetoelastic sensor based endotoxin detection system is ideally suited for wide-spread use in endotoxin screening for sepsis prevention.  相似文献   

20.
The Limulus in vitro endotoxin assay was evaluated as a possible method for the prompt detection of significant gram-negative bacteriuria in children. This assay is capable of detecting endotoxin associated with intact cell walls of viable gram-negative bacteria as well as free endotoxin. Quantitative results are obtained following a 1-h incubation of Limulus lysate and 10-fold dilutions of otherwise untreated urine. A standard curve of Limulus activity and viable cell counts of Escherichia coli and Klebsiella pneumoniae in urine demonstrated that a positive Limulus reaction at a dilution of 1:100 or 1:1,000 indicated a colony count of at least 100,000 bacteria/ml. A positive Limulus reaction only from undiluted urine or at a dilution of 1:10 indicated less than 100,000 cells/ml. These experimental observations were confirmed by comparing the Limulus test with quantitative plate counts on 209 urine specimens from a mixed pediatric population. These results indicate that the Limulus assay is a simple, accurate method for rapid presumptive detection of gram-negative bacteriuria in patients where an immediate diagnosis is needed. This test would also seem promising for screening large patient populations for bacteriuria or for monitoring the effectiveness of treatment of urinary tract infections.  相似文献   