首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Capillary electrophoresis (CE) was employed to analyze lactate dehydrogenase (LDH) in human erythrocytes using an amperometric detector with a carbon fiber micro-disk bundle electrode. LDH activity was measured by determining the amount of NADH generated by LDH through a enzyme-catalyzed reaction between NAD(+) and lithium lactate. The factors influencing the enzyme-catalyzed reaction, separation and detection were examined and optimized. The following conditions were suitable for the determination of LDH: running buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 7.5); separation voltage, 20.0 kV; detection potential, 1.00 V (versus saturated calomel electrode (SCE)). The conditions of enzyme-catalyzed reaction were: reaction buffer, 5.0 x 10(-2)mol/l Tris-HCl (pH 9.3); substrates, 5.0 x 10(-2)mol/l lithium lactate and 5.0 x 10(-3)mol/l NAD(+); reaction time, 10 min. The concentration limit of detection (LOD) of the method was 0.017 U/ml at a signal-to-noise (S/N) ratio of 3, which corresponded to 1.10 x 10(-10)mol/l, and the mass LOD was 2 x 10(-20)mol. The linear dynamic range was 0.039-4.65 U/ml for the injection voltage of 5.0 kV and injection time of 10s. The relative standard deviation (R.S.D.) was 0.85% for the migration time and 1.8% for the electrophoretic peak area. The method was applied to determine LDH in human erythrocytes. The recovery of the method was between 98 and 101%.  相似文献   

2.
Capillary zone electrophoresis was employed for the determination of midecamycin using an end-column amperometric detection with a carbon fiber micro-disk bundle electrode at a constant potential of +1.15 V vs. saturated calomel electrode. The optimum conditions of separation and detection are 1.00x10(-3) mol l(-1) Na(2)HPO(4)-3.49x10(-4) mol l(-1) NaOH (pH 11.4) for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The limit of detection is 5.0x10(-7) mol l(-1) or 0.41 fmol (S/N=3). The linear range of the calibration curve is 1.00x10(-6)-1.00x10(-3) mol l(-1). The relative standard deviation is 1.4% for the migration time and 4.9% for the electrophoretic peak current. The method could be applied to the determination of midecamycin in human urine. In this case, a separation voltage of 14 kV was used.  相似文献   

3.
A simple method for determination of perphenazine by capillary zone electrophoresis with amperometric detection is described. The optimum conditions of separation and detection are 1.50 x 10(-3) mol/l Na(2)B(4)O(7)-1.0 x 10(-3) mol/l NaOH (pH 9.9) for the buffer solution, 18 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, and 0.80 V versus saturated calomel electrode for the detection potential, respectively. The limit of detection is 5.0 x 10(-8) mol/l or 44 amol (S/N=3). The linear range of the calibration curve is 1.00 x 10(-7) to 1.00 x 10(-4) mol/l. The relative standard deviation is 1.5% for the migration time and 2.9% for the electrophoretic current at peak maximum. The method is applied to the determination of perphenazine in human urine.  相似文献   

4.
Capillary zone electrophoresis was employed for the determination of lactate using end-column amperometric detection at a carbon fiber bundle microdisk electrode. The optimum conditions of separation and detection are 3.6 x 10(-3) mol/l Na(2)HPO(4)-1.4 x 10(-3) mol/l NaH(2)PO (pH 7.2) for the buffer solution, 18 kV for the separation voltage and 1.60 V versus the saturated calomel electrode for the detection potential. The limit of detection is 7.6 x 10(-7) mol/l or 1.7 fmol (S/N=3) and the linear range is 1.7 x 10(-6)-8.2 x 10(-4) mol/l for the injection voltage of 6 kV and injection time of 5 s. The RSD is 1.8% for the migration time and 3.3% for the electrophoretic peak current. The method was applied to the determination of lactate in human saliva. The recovery of the method is between 95 and 109%.  相似文献   

5.
A stable electroactive thin film of poly(caffeic acid) has been deposited on the surface of a glassy carbon electrode by potentiostatic technique in an aqueous solution containing caffeic acid. Poly(caffeic acid) was used as a modified electrode for the detection of ascorbic acid (AA), epinephrine (EP), uric acid (UA) and their mixture by cyclic voltammetry. This modified electrode exhibits potent and persistent electron-mediating behavior followed by well-separated oxidation peaks towards AA, EP and UA with activation overpotential. For the ternary mixture containing AA, EP and UA, the three compounds can well separate from each other at the scan rate of 20 mVs(-1) with a potential difference of 156, 132 and 288 mV between AA and EP, EP and UA and AA and UA, respectively, which was large enough to determine AA, EP and UA individually and simultaneously. The catalytic peak current obtained, was linearly dependent on the AA, EP and UA concentrations in the range of 2.0 x 10(-5) to 1.0 x 10(-3) mol l(-1), 2.0 x 10(-6) to 8.0 x 10(-5) mol l(-1) and 5.0 x 10(-6) to 3.0 x 10(-4) mol l(-1), and the detection limits for AA, EP and UA were 7.0 x 10(-6), 2.0 x 10(-7) and 6.0 x 10(-7) mol l(-1), respectively. The modified electrode shows good sensitivity, selectivity and stability, and has been applied to the determination of EP in practical injection samples and that of EP, UA and AA simultaneously with satisfactory results.  相似文献   

6.
A novel determination method for josamycin (JOS) based on capillary electrophoresis-electrochemiluminescence detection has been described. In this study, platinum disk electrode (300 microm in diameter) was used as a working electrode and the conditions affecting separation and detection were investigated in detail. Under optimal condition: 40 cm separation capillary (75 microm i.d.); 1.25 V applied potential on the Pt disc of the ECL detector cell; 5 mM Ru(bpy)3(2+) and 50mM phosphate buffer (pH 7.5) in the detection cell; 12 kV separation voltage; 8s injection time; 10 kV injection voltage and 15 mM running buffer (pH 7.5), calibration curve was linear over the range from 10 ng/mL to 5.0 microg/mL with a detection limit of 3.1 ng/mL at a signal-to-noise ratio of 3. The method can be successfully applied for the determination of josamycin in rat plasma in 6 min and the extraction recoveries with spiked plasma samples were over 92%.  相似文献   

7.
Capillary zone electrophoresis was employed for the measurement of chloramphenicol using end-column amperometric detection with a carbon fiber micro-disk array electrode, at a constant potential of −1.00 V vs. saturated calomel electrode. The effect of oxygen in the buffer has been investigated. It is found that when the area of the carbon fiber electrode is smaller than 1.1 mm2, the interference of oxygen can be overcome. In this procedure deoxygenation is not necessary. The effect of pH, the concentration of the buffer and the high separation voltage across the capillary on the migration time, electrophoretic peak current and separation efficiency has been studied. The optimum conditions of separation and detection are 8.4×10−4 mol/l HOAc–3.2×10−3 mol/l NaOAc for the buffer solution, 20 kV for the separation voltage, 5 kV and 5 s for the injection voltage and the injection time, respectively. The calibration plot was found to be linear in the range 5×10−6 to 1×10−3 mol/l and the limit of detection is 9.1×10−7 mol/l or 1.4 fmol (S/N=2). The relative standard deviation is 1.1% for the migration time and 2.3% for the electrophoretic peak current. The method was applied to the determination of chloramphenicol in human serum.  相似文献   

8.
Direct electron transfer of hemoglobin (Hb) can be achieved in a Hb/montmorillonite (MMT)/polyvinyl alcohol multi-assembly at a pyrolytic graphite (PG) electrode. Accordingly, a novel nitric oxide (NO) biosensor is proposed. The reduction of NO is observed at a potential of approximately -783 mV (vs. SCE) at pH 5.5. At optimum pH, this biosensor shows a wide linear range of 1.0x10(-6)-2.5x10(-4) mol/l with a detection limit of 5.0x10(-7) mol/l. The sensor-to-sensor reproducibility is good consideringmacr; a relative standard deviation of 3.5% in five independent determinations at 5.0x10(-5) mol/l NO. The modified electrode is conveniently constructed and durable in long-term operations.  相似文献   

9.
In this paper, the amount of ascorbic acid (AA) in single rat peritoneal mast cell was determined by the method of capillary electrophoresis (CE) with electrochemical detection (ED) at a carbon fiber microdisk bundle electrode. The CE–ED system and the single-cell injection system were rearranged to make the operation more convenient and efficient. In the experiment, a self-made holder made of foam was used to keep the capillary from swing, which kept the stability of the baseline of the electropherogram. The single cell was lysed completely within 5 s using the 0.1% sodium dodecylsulfate (SDS) as the cell lysis solution together with the lysis voltage of 2 kV. The quantitation analysis was accomplished by the use of calibration curves, and the amount of AA in single rat peritoneal mast cell was from 2.4 to 7.1 fmol.  相似文献   

10.
The fabrication and application of a novel electrochemical detection (ED) method with the functionalized multi-wall carbon nanotubes (MWNTs) chemically modified electrode (CME) for liquid chromatography (LC) were described. The electrochemical behaviors of dopamine (DA) and other monoamine neurotransmitters at the CME were investigated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The results indicated that the CME exhibited efficient electrocatalytic effects on the current responses of monoamine neurotransmitters and their metabolites with high sensitivity, high stability and long-life activity. In LC-ED, DA, norepinephrine (NE), 3-methoxy-4-hydroxyphenylglycol (MHPG), 3,4-dihydroxyphenylacetic acid (DOPAC), 5-hydroxytryptamine (5-HT), 5-hydroxyindoleacetic acid (5-HIAA) and homovanillic acid (HVA) had good and stable current responses at the CME. The linear ranges of seven analytes were over four orders of magnitude and the detection limits were 2.5 x 10(-10) mol/l for DA, 2.5 x 10(-10) mol/l for NE, 5.0 x 10(-10) mol/l for MHPG, 3.0 x 10(-10) mol/l for DOPAC, 3.5 x 10(-10) mol/l for 5-HT, 6.0 x 10(-10) mol/l for 5-HIAA, 1.25 x 10(-9) mol/l for HVA. The application of this method coupled with microdialysis sampling for the determination of monoamine neurotransmitters and their metabolites in Parkinsonian patients' cerebrospinal fluid was satisfactory.  相似文献   

11.
A novel mercury-doped silver nanoparticles film glassy carbon (Ag/MFGC) electrode was prepared in this study. Electrochemical behaviors of cysteine on the Ag/MFGC electrode were investigated by electrochemical impedance spectroscopy and cyclic voltammetry (CV). The results indicated that cysteine could be strongly adsorbed on the surface of the Ag/MFGC electrode to form a thin layer. The doped electrode could catalyze the electrode reaction process of cysteine, and the cysteine displayed a pair of well-defined and nearly reversible CV peaks at the electrode in an acetate buffer solution (pH 5.0). The Ag/MFGC electrode was used for determination of cysteine by differential pulse voltammetry. The linear range was between 4.0x10(-7) and 1.3x10(-5) mol/L, with a detection limit of 1.0x10(-7) mol/L and a signal-to-noise ratio of 3. The relative standard deviation was 2.4% for seven successive determinations of 1.0x10(-5) mol/L cysteine. The determinations of cysteine in synthetic samples and urinal samples were carried out and satisfactory results were obtained. Amperometric application of the Ag/MFGC electrode as biosensors is proposed.  相似文献   

12.
Yu Q  Zhao S  Ye F  Li S 《Analytical biochemistry》2007,369(2):187-191
A new analytical method based on capillary electrophoresis (CE) separation and optical fiber light-emitting diode (LED)-induced fluorescence detection has been developed for the determination of octopamine. Naphthalene-2,3-dicarboxaldehyde (NDA) was used for precolumn derivatization of octopamine. The separation and determination of the derivative was performed using a laboratory-built CE system with an optical fiber LED-induced fluorescence detector. Optimal separation was obtained at 20 kV using a background electrolyte solution consisting of 25 mM sodium borate (pH 9.2). High sensitivity detection was achieved by the optical fiber LED-induced fluorescence detection using a purple LED as the excitation source. The limit of detection (signal/noise=3) for octopamine was 5.0 x 10(-9)M. A calibration curve ranging from 1.0 x 10(-8) to 5.0 x 10(-7)M was shown to be linear. Using this method, the levels of octopamine in human plasma from healthy donors were determined.  相似文献   

13.
Gao D  Hu J  Yang M  Li Q 《Analytical biochemistry》2006,358(1):70-75
A novel COOH+ ion implantation-modified indium tin oxide (COOH/ITO) electrode was prepared for the first time and applied for determination of daunomycin (or daunorubicin [DNR]). The electrode showed higher catalytic activity than bare ITO electrode with good reproducibility and stability. The determination condition of linear voltammetry was optimized. A calibration curve was obtained over the range 2.0 x 10(-7) to 5.0 x 10(-6)mol/L, with a correlation coefficient of 0.9909 and a limit of detection of 1.0 x 10(-7)mol/L. The selectivity of the electrode was illustrated by determination of DNR in samples prepared of urine. X-ray photoelectron spectroscopy (XPS) analysis results showed that the implanted COOH+ maintained characteristics of organic group -COOH. A field emission-scanning electron microscope (FSEM) result showed that the implanted surface caused defects and partial dislocations and formed many active centers.  相似文献   

14.
On the top of a multi-walled carbon nanotubes (MWNTs) modified glassy carbon electrode (MWNTs/GCE), Pt nanoclusters were electrochemically deposited, fabricating a Pt/MWNTs composite modified electrode, Pt/MWNTs/GCE. X-ray photoelectron spectroscopy, powder X-ray diffraction and field emission scanning electron microscope were used for the surface characterization of the electrode, and demonstrated the formation and distribution of Pt clusters of Pt nanoparticles of 8.4 nm in averaged size in the MWNTs matrix. The preliminary study found that this composite modified electrode has strong electrocatalytic activity toward the oxidation of estrogens involving estradiol, estrone and estriol. The voltammetric behavior of estrogens on this electrode was investigated by cyclic voltammetry, linear sweep voltammetry and square-wave voltammetry. In comparison with the MWNTs/GCE or a Pt nanoparticles modified GCE prepared in the similar way, this composite modified electrode exhibited much higher current sensitivity and catalytic activity. This electrode is also stable. The linear range of square-wave voltammetric determination was 5.0 x 10(-7)-1.5 x 10(-5)mol/L for estradiol, 2.0 x 10(-6)-5.0 x 10(-5)mol/L for estrone, and 1.0 x 10(-6)-7.5 x 10(-5)mol/L for estriol. Under an assumption that the concentration ratio of estradiol:estrone:estriol is 2:2:1, the real sample of blood serums was tested for the determination using this electrode. Satisfactory result was obtained with averaged recovery of 105%.  相似文献   

15.
A high-performance capillary electrophoresis with electrochemical detection method has been developed for the determination of the pharmacologically active ingredients, acacetin, rutin, umbelliferone, kaempferol, apigenin, luteolin and quercetin, in Herba Saussureae Involucratae. Under optimum conditions, the seven analytes could be completely separated within 19 min in a 75 cm length capillary at a separation voltage of 16 kV in a 50 mM borax running buffer (pH 9.2). A 300 microm diameter carbon disk electrode, positioned opposite the outlet of the capillary in a wall-jet configuration at a potential of +950 mV (vs a saturated calomel electrode) was used as the working electrode. A good linear relationship was established between peak current and concentration of the analytes over two orders of magnitude with detection limits (signal-to-noise ratio = 3) ranging from 1.2 x 10(-7) to 4.1 x 10(-8) g/mL for all analytes. The proposed method has been successfully applied to the analyses of bio-active components of Herba Saussureae Involucratae samples after a relatively simple extraction procedure. The assay results show that the resultant electrochemical profiles are indicative of the content diversity of each electrochemically active ingredient in the various samples, and may also offer some evidence for phytotaxonomy.  相似文献   

16.
A recently constructed carbon composite electrode using room temperature ionic liquid as pasting binder was employed as a novel electrode for sensitive, simultaneous determination of dopamine (DA), ascorbic acid (AA), and uric acid (UA). The apparent reversibility and kinetics of the electrochemical reaction for DA, AA, and UA found were improved significantly compared to those obtained using a conventional carbon paste electrode. The results show that carbon ionic liquid electrode (CILE) reduces the overpotential of DA, AA, and UA oxidation, without showing any fouling effect due to the deposition of their oxidized products. In the case of DA, the oxidation and reduction peak potentials appear at 210 and 135mV (vs Ag/AgCl, KCl, 3.0M), respectively, and the CILE shows a significantly better reversibility for dopamine. The oxidation peak due to the oxidation of AA occurs at about 60mV. For UA, a sharp oxidation peak at 340mV and a small reduction peak at 250mV are obtained at CILE. Differential pulse voltammetry was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Relative standard deviation for DA, AA, and UA determinations were less than 3.0% and DA, AA, and UA can be determined in the ranges of 2.0x10(-6)-1.5x10(-3), 5.0x10(-5)-7.4x10(-3), and 2.0x10(-6)-2.2x10(-4)M, respectively. The method was applied to the determination of DA, AA, and UA in human blood serum and urine samples.  相似文献   

17.
An improved high-performance liquid chromatographic (HPLC) method using electrochemical detection (ED) is described capable of routinely measuring the low levels of acetylcholine (ACh) typically found in rat brain microdialysis samples. Microdialysis was performed in the striatum of the urethane anesthetized rat using a 4-mm membrane length, high recovery (40% at 1.0 μl/min; ambient conditions), loop-design probe perfused with an artificial cerebrospinal fluid (aCSF) solution containing physiologically normal calcium levels (1.2 mM). The HPLC method utilizes a polymeric stationary phase to resolve choline (Ch) from ACh. These analytes are then converted to hydrogen peroxide (H2O2) by a solid-phase reactor (containing immobilized choline oxidase and acetylcholinesterase enzymes). The H2O2 is detected amperometrically and quantitated on a platinum (Pt) working electrode (+300 mV; with a unique analytical cell featuring a solid-state palladium reference electrode). Two designs of the Pt working electrode were examined, differing only in the support material used (Kel-F or PEEK). The Kel-F/Pt electrode had a limit of detection (LOD) for both analytes of <30 fmol per 10 μl with a signal-to-noise ratio of 3:1. Striatal microdialysis perfusates were monitored for ACh and Ch over a 0–1000 nM range of neostigmine (NEO) in the CSF perfusion medium. Using the 4-mm probe, basal ACh and Ch levels were detected with a NEO level as low as 10 nM and were found to be 37 ± 3 fmol and 22 ± 1 pmol per 10 μl (mean ± S.E.M., n = 6 replicates) respectively. In similar experiments using 3-mm concentric probes comparable (lower) levels of ACh were found with the 50 and 1000 nM NEO doses (n = 4–21 animals). ACh could not be reliably quantitated when animals were perfused with the 10 nM dose of NEO (n = 4). The PEEK/Pt electrode had an improved LOD of < 20 fmol per 10 μl due to a two- to three-fold decrease in the background noise component. Basal striatal levels of ACh in the absence of NEO approached the LOD and were found to be 15 ± 2 fmol per 10 μl; Ch was 5 ± 1 pmol per 10 μl (n = 2, mean of five basal samples). The analytical system requires very little maintenance; a simple electrochemical electrode cleaning step eliminates the need for routine polishing of the Pt electrode and the mobile phase is stable for up to one week. Both ACh and Ch are resolved in under 7 min making this method highly suitable for analysis of microdialysis samples.  相似文献   

18.
Wu S  Wang T  Gao Z  Xu H  Zhou B  Wang C 《Biosensors & bioelectronics》2008,23(12):1776-1780
A beta-cyclodextrin (CD) modified copolymer membrane of sulfanilic acid (p-ASA) and N-acetylaniline (SPNAANI) on glassy carbon electrode (GCE) was prepared and used to determine uric acid (UA) in the presence of a large excess of ascorbic acid (AA) by differential pulse voltammetry (DPV). The properties of the copolymer were characterized by X-ray photoelectron spectra (XPS) and Raman spectroscopy. The oxidation peaks of AA and UA were well separated at the composite membrane modified electrode in phosphate buffer solution (PBS, pH 7.4). A linear relationship between the peak current and the concentration of UA was obtained in the range from 1.0 x 10(-5) to 3.5 x 10(-4)mol L(-1), and the detection limit was 2.7 x 10(-6)mol L(-1) at a signal-to-noise ratio of 3. Two hundred and fifty-fold excess of AA did not interfere with the determination of UA. The application of the prepared electrode was demonstrated by measuring UA in human serum samples without any pretreatment, and the results were comparatively in agreement with the spectrometric clinical assay method.  相似文献   

19.
We discovered that 4-(2-pyridylazo) resorcinol (PAR) has a strong catalytic effect on luminol-potassium ferricyanide chemiluminescence (CL). Results indicated that the chemiluminescence intensities at maximum light emission were linearly corrected with the concentration of PAR over the range 1.0 x 10(-5)-1.0 x 10(-7) mol/L. A detection limit of 5.7 x 10(-8) mol/L for PAR was achieved. It was found that some metal ions strongly affected this catalytic reaction. Based on this finding, the luminol-potassium ferricyanide-PAR reaction was developed for the determination of metal ions. The detection limits (S/N = 3) for Ni2+, Cr3+, Zn2+, Co2+ and Mn2+ were determined to be 1.0 x 10(-9) mol/L, 5.0 x 10(-9) mol/L, 5.0 x 10(-8) mol/L, 1.0 x 10(-9) mol/L and 1.0 x 10(-8) mol/L, respectively. In addition, the relative standard deviation values for these metal ion assays were in the range 0.82-2.72% (n = 6).  相似文献   

20.
The fast analysis of ranitidine is of clinical importance in understanding its efficiency and a patient's treatment history. In this paper, a novel determination method for ranitidine based on capillary electrophoresis-electrochemiluminescence detection is described. The conditions affecting separation and detection were investigated in detail. End-column detection of ranitidine in 5 mM Ru(bpy)(3)(2+) solution at applied voltage of 1.20 V was performed. Favorable ECL intensity with higher column efficiency was achieved by electrokinetic injection for 10s at 10 kV. The R.S.D. values of ECL intensity and migration time were 6.38 and 1.84% for 10(-4) M and 6.01 and 0.60% for 10(-5) M, respectively. A detection limit of 7 x 10(-8) M (S/N=3) was achieved. The proposed method was applied satisfactorily to the determination of ranitidine in urine in 6 min.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号