首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Barnea E  Sorkin R  Ziv T  Beer I  Admon A 《Proteomics》2005,5(13):3367-3375
Prefractionations of proteins prior to their proteolysis, chromatography, and MS/MS analyses help reduce complexity and increase the yield of protein identifications. A number of methods were evaluated here for prefractionating serum samples distributed to the participating laboratories as part of the human Plasma Proteome Project. These methods include strong cation exchange (SCX) chromatography, slicing of SDS-PAGE gel bands, and liquid-phase IEF of the proteins. The fractionated proteins were trypsinized and the resulting peptides were resolved and analyzed by multidimensional protein identification technology coupled to IT MS/MS. The MS/MS spectra were clustered, combined, and searched against the IPI protein databank using Pep-Miner. The identification results were evaluated for the efficacy of the different prefractionation methodologies to identify larger numbers of proteins at higher confidence and to achieve the best coverage of the proteins with the identified peptides. Prefractionation based on SCX resulted in the largest number of identified proteins, followed by gel slices and then the liquid-phase IEF. An important observation was that each of the methods revealed a set of unique proteins, some identified with high confidence. Therefore, for comprehensive identification of the serum proteins, several different prefractionation approaches should be used in parallel.  相似文献   

2.
Four different immunoassay and antibody microarray methods performed at four different sites were used to measure the levels of a broad range of proteins (N = 323 assays; 39, 88, 168, and 28 assays at the respective sites; 237 unique analytes) in the human serum and plasma reference specimens distributed by the Plasma Proteome Project (PPP) of the HUPO. The methods provided a means to (1) assess the level of systematic variation in protein abundances associated with blood preparation methods (serum, citrate-anticoagulated-plasma, EDTA-anticoagulated-plasma, or heparin-anticoagulated-plasma) and (2) evaluate the dependence on concentration of MS-based protein identifications from data sets using the HUPO specimens. Some proteins, particularly cytokines, had highly variable concentrations between the different sample preparations, suggesting specific effects of certain anticoagulants on the stability or availability of these proteins. The linkage of antibody-based measurements from 66 different analytes with the combined MS/MS data from 18 different laboratories showed that protein detection and the quality of MS data increased with analyte concentration. The conclusions from these initial analyses are that the optimal blood preparation method is variable between analytes and that the discovery of blood proteins by MS can be extended to concentrations below the ng/mL range under certain circumstances. Continued developments in antibody-based methods will further advance the scientific goals of the PPP.  相似文献   

3.
Identification of novel diagnostic or therapeutic biomarkers from human blood plasma would benefit significantly from quantitative measurements of the proteome constituents over a range of physiological conditions. Herein we describe an initial demonstration of proteome-wide quantitative analysis of human plasma. The approach utilizes postdigestion trypsin-catalyzed 16O/18O peptide labeling, two-dimensional LC-FTICR mass spectrometry, and the accurate mass and time (AMT) tag strategy to identify and quantify peptides/proteins from complex samples. A peptide accurate mass and LC elution time AMT tag data base was initially generated using MS/MS following extensive multidimensional LC separations to provide the basis for subsequent peptide identifications. The AMT tag data base contains >8,000 putative identified peptides, providing 938 confident plasma protein identifications. The quantitative approach was applied without depletion of high abundance proteins for comparative analyses of plasma samples from an individual prior to and 9 h after lipopolysaccharide (LPS) administration. Accurate quantification of changes in protein abundance was demonstrated by both 1:1 labeling of control plasma and the comparison between the plasma samples following LPS administration. A total of 429 distinct plasma proteins were quantified from the comparative analyses, and the protein abundances for 25 proteins, including several known inflammatory response mediators, were observed to change significantly following LPS administration.  相似文献   

4.
Beer I  Barnea E  Admon A 《Proteomics》2005,5(13):3491-3496
The human Plasma Proteome Project (PPP) is a large-scale collaboration between many laboratories. One of the most demanding tasks in the PPP involved the analysis of very large amounts of raw MS/MS data produced by the participants. The main approach for managing this task was letting the participants analyze their own data and submit the results to the central PPP repository as lists of identified proteins and peptides. To complement this distributed approach, we also performed centralized analysis of the raw MS/MS data provided by the participants. Due to the data redundancy inherent in such a project, centralized analysis has the potential to reduce the computational effort by reducing redundancy before the analysis. Centralized analysis can also unify the process and take advantage of data sharing among laboratories to improve protein identification and validation. The process we employed included removing low-quality spectra, clustering spectra by mutual similarity, and applying uniform peptide and protein identification procedures. To demonstrate the process, we analyzed 5.28 million MS/MS spectra derived by eight laboratories from tryptic peptides of serum and plasma proteins.  相似文献   

5.
Li X  Gong Y  Wang Y  Wu S  Cai Y  He P  Lu Z  Ying W  Zhang Y  Jiao L  He H  Zhang Z  He F  Zhao X  Qian X 《Proteomics》2005,5(13):3423-3441
Based on the same HUPO reference specimen (C1-serum) with the six proteins of highest abundance depleted by immunoaffinity chromatography, we have compared five proteomics approaches, which were (1) intact protein fractionation by anion-exchange chromatography followed by 2-DE-MALDI-TOF-MS/MS for protein identification (2-DE strategy); (2) intact protein fractionation by 2-D HPLC followed by tryptic digestion of each fraction and microcapillary RP-HPLC/microESI-MS/MS identification (protein 2-D HPLC fractionation strategy); (3) protein digestion followed by automated online microcapillary 2-D HPLC (strong cation-exchange chromatography (SCX)-RPC) with IT microESI-MS/MS; (online shotgun strategy); (4) same as (3) with the SCX step performed offline (offline shotgun strategy) and (5) same as (4) with the SCX fractions reanalysed by optimised nanoRP-HPLC-nanoESI-MS/MS (offline shotgun-nanospray strategy). All five approaches yielded complementary sets of protein identifications. The total number of unique proteins identified by each of these five approaches was (1) 78, (2) 179, (3) 131, (4) 224 and (5) 330 respectively. In all, 560 unique proteins were identified. One hundred and sixty-five proteins were identified through two or more peptides, which could be considered a high-confidence identification. Only 37 proteins were identified by all five approaches. The 2-DE approach yielded more information on the pI-altered isoforms of some serum proteins and the relative abundance of identified proteins. The protein prefractionation strategy slightly improved the capacity to detect proteins of lower abundance. Optimising the separation at the peptide level and improving the detection sensitivity of ESI-MS/MS were more effective than fractionation of intact proteins in increasing the total number of proteins identified. Overall, electrophoresis and chromatography, coupled respectively with MALDI-TOF/TOF-MS and ESI-MS/MS, identified complementary sets of serum proteins.  相似文献   

6.
The low molecular weight plasma proteome and its biological relevance are not well defined; therefore, experiments were conducted to directly sequence and identify peptides observed in plasma and serum protein profiles. Protein fractionation, matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) profiling, and liquid-chromatography coupled to MALDI tandem mass spectrometry (MS/MS) sequencing were used to analyze the low molecular weight proteome of heparinized plasma. Four fractionation techniques using functionally derivatized 96-well plates were used to extract peptides from plasma. Tandem TOF was successful for identifying peptides up to m/z 5500 with no prior knowledge of the sequence and was also used to verify the sequence assignments for larger ion signals. The peptides (n>250) sequenced in these profiles came from a surprisingly small number of proteins (n approximately 20), which were all common to plasma, including fibrinogen, complement components, antiproteases, and carrier proteins. The cleavage patterns were consistent with those of known plasma proteases, including initial cleavages by thrombin, plasmin and complement proteins, followed by aminopeptidase and carboxypeptidase activity. On the basis of these data, we discuss limitations in biomarker discovery in the low molecular weight plasma or serum proteome using crude fractionation coupled to MALDI-MS profiling.  相似文献   

7.
The human plasma proteome: analysis of Chinese serum using shotgun strategy   总被引:8,自引:0,他引:8  
He P  He HZ  Dai J  Wang Y  Sheng QH  Zhou LP  Zhang ZS  Sun YL  Liu F  Wang K  Zhang JS  Wang HX  Song ZM  Zhang HR  Zeng R  Zhao X 《Proteomics》2005,5(13):3442-3453
We have investigated the serum proteome of Han-nationality Chinese by using shotgun strategy. A complete proteomics analysis was performed on two reference specimens from a total of 20 healthy donors, in which each sample was made from ten-pooled male or female serum, respectively. The methodology used encompassed (1) removal of six high-abundant proteins; (2) tryptic digestion of low- and high-abundant proteins of serum; (3) separation of peptide mixture by RP-HPLC followed by ESI-MS/MS identification. A total of 944 nonredundant proteins were identified under a stringent filter condition (X(corr) > or = 1.9, > or = 2.2, and > or = 3.75, < or = C(n) > or = 0.1, and R(sp) > or = 4.0) in both pooled male and female samples, in which 594 and 622 entire proteins were found, respectively. Compared with the total 3020 protein identifications confirmed by more than one laboratory or more than one specimen in HUPO Plasma Proteome Project (PPP) participating laboratories recently, 206 proteins were identified with at least two distinct peptides per protein and 185 proteins were considered as high-confidence identification. Moreover, some lower abundance serum proteins (ng/mL range) were detected, such as complement C5 and CA125, routinely used as an ovarian cancer marker in plasma and serum. The resulting nonredundant list of serum proteins would add significant information to the knowledge base of human plasma proteome and facilitate disease markers discovery.  相似文献   

8.
Shotgun proteome analysis platforms based on multidimensional liquid chromatography-tandem mass spectrometry (LC-MS/MS) provide a powerful means to discover biomarker candidates in tissue specimens. Analysis platforms must balance sensitivity for peptide detection, reproducibility of detected peptide inventories and analytical throughput for protein amounts commonly present in tissue biospecimens (< 100 microg), such that platform stability is sufficient to detect modest changes in complex proteomes. We compared shotgun proteomics platforms by analyzing tryptic digests of whole cell and tissue proteomes using strong cation exchange (SCX) and isoelectric focusing (IEF) separations of peptides prior to LC-MS/MS analysis on a LTQ-Orbitrap hybrid instrument. IEF separations provided superior reproducibility and resolution for peptide fractionation from samples corresponding to both large (100 microg) and small (10 microg) protein inputs. SCX generated more peptide and protein identifications than did IEF with small (10 microg) samples, whereas the two platforms yielded similar numbers of identifications with large (100 microg) samples. In nine replicate analyses of tryptic peptides from 50 microg colon adenocarcinoma protein, overlap in protein detection by the two platforms was 77% of all proteins detected by both methods combined. IEF more quickly approached maximal detection, with 90% of IEF-detectable medium abundance proteins (those detected with a total of 3-4 peptides) detected within three replicate analyses. In contrast, the SCX platform required six replicates to detect 90% of SCX-detectable medium abundance proteins. High reproducibility and efficient resolution of IEF peptide separations make the IEF platform superior to the SCX platform for biomarker discovery via shotgun proteomic analyses of tissue specimens.  相似文献   

9.
This report describes a new method for desorption of low-molecular weight (LMW) peptides from abundant blood proteins for use in subsequent mass spectrometry analyses. Heating of diluted blood serum to 98°C for 15min resulted in dissociation of LMW peptides from the most abundant blood proteins. Application of blood plasma/serum fractionation using magnetic beads with a functionalized surface followed by heating of the resultant fractions significantly increases the number of LMW peptides detected by MALDI-TOF MS, enhances the general reproducibility of mass spectrometry profiles and considerably increases the number of identified blood serum peptides by LC-MS/MS using an Agilent 6520 Accurate-Mass Q-TOF.  相似文献   

10.
A novel strategy, termed protein array pixelation, is described for comprehensive profiling of human plasma and serum proteomes. This strategy consists of three sequential high-resolution protein prefractionation methods (major protein depletion, solution isoelectrofocusing, and 1-DE) followed by nanocapillary RP tryptic peptide separation prior to MS/MS analysis. The analysis generates a 2-D protein array where each pixel in the array contains a group of proteins with known pI and molecular weight range. Analysis of the HUPO samples using this strategy resulted in 575 and 2890 protein identifications from plasma and serum, respectively, based on HUPO-approved criteria for high-confidence protein assignments. Most importantly, a substantial number of low-abundance proteins (low ng/mL - pg/mL range) were identified. Although larger volumes were used in initial prefractionation steps, the protein identifications were derived from fractions equivalent to approximately 0.6 microL (45 microg) of plasma and 2.4 microL (204 microg) of serum. The time required for analyzing the entire protein array for each sample is comparable to some published shotgun analyses of plasma and serum proteomes. Therefore, protein array pixelation is a highly sensitive method capable of detecting proteins differing in abundance by up to nine orders of magnitude. With further refinement, this method has the potential for even higher capacity and higher throughput.  相似文献   

11.
The pilot phase of the HUPO Plasma Proteome Project (PPP) is an international collaboration to catalog the protein composition of human blood plasma and serum by analyzing standardized aliquots of reference serum and plasma specimens using a variety of experimental techniques. Data management for this project included collection, integration, analysis, and dissemination of findings from participating organizations world-wide. Accomplishing this task required a communication and coordination infrastructure specific enough to support meaningful integration of results from all participants, but flexible enough to react to changing requirements and new insights gained during the course of the project and to allow participants with varying informatics capabilities to contribute. Challenges included integrating heterogeneous data, reducing redundant information to minimal identification sets, and data annotation. Our data integration workflow assembles a minimal and representative set of protein identifications, which account for the contributed data. It accommodates incomplete concordance of results from different laboratories, ambiguity and redundancy in contributed identifications, and redundancy in the protein sequence databases. Recommendations of the PPP for future large-scale proteomics endeavors are described.  相似文献   

12.
MS/MS and database searching has emerged as a valuable technology for rapidly analyzing protein expression, localization, and post-translational modifications. The probability-based search engine Mascot has found widespread use as a tool to correlate tandem mass spectra with peptides in a sequence database. Although the Mascot scoring algorithm provides a probability-based model for peptide identification, the independent peptide scores do not correlate with the significance of the proteins to which they match. Herein, we describe a heuristic method for organizing proteins identified at a specified false-discovery rate using Mascot-matched peptides. We call this method PROVALT, and it uses peptide matches from a random database to calculate false-discovery rates for protein identifications and reduces a complex list of peptide matches to a nonredundant list of homologous protein groups. This method was evaluated using Mascot-identified peptides from a Trypanosoma cruzi epimastigote whole-cell lysate, which was separated by multidimensional LC and analyzed by MS/MS. PROVALT was then compared with the two traditional methods of protein identification when using Mascot, the single peptide score and cumulative protein score methods, and was shown to be superior to both in regards to the number of proteins identified and the inclusion of lower scoring nonrandom peptide matches.  相似文献   

13.
The proteomic analysis of serum (plasma) has been a major approach to determining biomarkers essential for early disease diagnoses and drug discoveries. The determination of these biomarkers, however, is analytically challenging since the dynamic concentration range of serum proteins/peptides is extremely wide (more than 10 orders of magnitude). Thus, the reduction in sample complexity prior to proteomic analyses is essential, particularly in analyzing low-abundance protein biomarkers. Here, we demonstrate a novel approach to the proteomic analyses of human serum that uses an originally developed serum protein separation device and a sequentially linked 3-D-LC-MS/MS system. Our hollow-fiber-membrane-based serum pretreatment device can efficiently deplete high-molecular weight proteins and concentrate low-molecular weight proteins/peptides automatically within 1 h. Four independent analyses of healthy human sera pretreated using this unique device, followed by the 3-D-LC-MS/MS successfully produced 12 000-13 000 MS/MS spectra and hit around 1800 proteins (>95% reliability) and 2300 proteins (>80% reliability). We believe that the unique serum pretreatment device and proteomic analysis protocol reported here could be a powerful tool for searching physiological biomarkers by its high throughput (3.7 days per one sample analysis) and high performance of finding low abundant proteins from serum or plasma samples.  相似文献   

14.
In high-throughput mass spectrometry proteomics, peptides and proteins are not simply identified as present or not present in a sample, rather the identifications are associated with differing levels of confidence. The false discovery rate (FDR) has emerged as an accepted means for measuring the confidence associated with identifications. We have developed the Systematic Protein Investigative Research Environment (SPIRE) for the purpose of integrating the best available proteomics methods. Two successful approaches to estimating the FDR for MS protein identifications are the MAYU and our current SPIRE methods. We present here a method to combine these two approaches to estimating the FDR for MS protein identifications into an integrated protein model (IPM). We illustrate the high quality performance of this IPM approach through testing on two large publicly available proteomics datasets. MAYU and SPIRE show remarkable consistency in identifying proteins in these datasets. Still, IPM results in a more robust FDR estimation approach and additional identifications, particularly among low abundance proteins. IPM is now implemented as a part of the SPIRE system.  相似文献   

15.
Human plasma and serum proteins are subject to intrinsic proteolytic degradation both during and after blood collection. By monitoring peptides, we investigated the stability of plasma and serum samples and the effects of anticoagulants and protease inhibitors on the plasma samples. Serum and plasma were subjected to time-course incubation, and the peptides (750-3200 Da) were extracted and analyzed with MALDI-TOF MS. Peptides of interest were further identified by MALDI-TOF/TOF MS and ESI-MS/MS analyses. Our observations indicate that plasma peptides are significantly different from serum peptides. Intrinsic proteases cause these differences between plasma and serum samples, as well as the differences among three plasma samples using either EDTA, sodium citrate, or heparin as the anticoagulant, which accounts for partial inhibitory effects on plasma proteolytic activities. Proteases and peptidases, including both aminopeptidases and carboxypeptidases, also cause time-dependent, sequential generation and digestion of the peptides in serum and all three plasmas, specifically during early sample collection and processing. Protease inhibitors within an EDTA-plasma-collection device inhibit both intrinsic plasma peptidases and proteases and moderate the time-dependent changes of the plasma peptides, including bradykinin, and complement C4- and C3- derived peptides. Our results suggest that mixing protease inhibitors immediately with blood during blood collection provides enhanced stabilization of the plasma proteome.  相似文献   

16.
We describe the application of a peptide retention time reversed phase liquid chromatography (RPLC) prediction model previously reported (Petritis et al. Anal. Chem. 2003, 75, 1039) for improved peptide identification. The model uses peptide sequence information to generate a theoretical (predicted) elution time that can be compared with the observed elution time. Using data from a set of known proteins, the retention time parameter was incorporated into a discriminant function for use with tandem mass spectrometry (MS/MS) data analyzed with the peptide/protein identification program SEQUEST. For singly charged ions, the number of confident identifications increased by 12% when the elution time metric is included compared to when mass spectral data is the sole source of information in the context of a Drosophila melanogaster database. A 3-4% improvement was obtained for doubly and triply charged ions for the same biological system. Application to the larger Rattus norvegicus (rat) and human proteome databases resulted in an 8-9% overall increase in the number of confident identifications, when both the discriminant function and elution time are used. The effect of adding "runner-up" hits (peptide matches that are not the highest scoring for a spectra) from SEQUEST is also explored, and we find that the number of confident identifications is further increased by 1% when these hits are also considered. Finally, application of the discriminant functions derived in this work with approximately 2.2 million spectra from over three hundred LC-MS/MS analyses of peptides from human plasma protein resulted in a 16% increase in confident peptide identifications (9022 vs 7779) using elution time information. Further improvements from the use of elution time information can be expected as both the experimental control of elution time reproducibility and the predictive capability are improved.  相似文献   

17.
Peptide-based mass spectrometry approaches, such as multiple reaction monitoring, provide a powerful means to measure candidate protein biomarkers in plasma. A potential confounding problem is the effect of preanalytical variables, which may affect the integrity of proteins and peptides. Although some blood proteins undergo rapid physiological proteolysis ex vivo, the stability of most plasma proteins to preanalytical variables remains largely unexplored. We applied liquid chromatography-tandem mass spectrometry shotgun proteomics and multiple reaction monitoring analyses to characterize the stability of proteins at the peptide level in plasma. We systematically evaluated the effects of delay in plasma preparation at different temperatures, multiple freeze-thaw cycles and erythocyte hemolysis on peptide and protein inventories in prospectively collected human plasma. Time course studies indicated few significant changes in peptide and protein identifications, semitryptic peptides and methionine-oxidized peptides in plasma from blood collected in EDTA plasma tubes and stored for up to a week at 4 °C or room temperature prior to plasma isolation. Similarly, few significant changes were observed in similar analyses of plasma subjected to up to 25 freeze-thaw cycles. Hemolyzed samples produced no significant differences beyond the presence of hemoglobin proteins. Finally, paired comparisons of plasma and serum samples prepared from the same patients also yielded few significant differences, except for the depletion of fibrinogen in serum. Blood proteins thus are broadly stable to preanalytical variables when analyzed at the peptide level. Collection protocols to generate plasma for multiple reaction monitoring-based analyses may have different requirements than for other analyses directed at intact proteins.  相似文献   

18.
A very popular approach in proteomics is the so-called "shotgun LC-MS/MS" strategy. In its mostly used form, a total protein digest is separated by ion exchange fractionation in the first dimension followed by off- or on-line RP LC-MS/MS. We replaced the first dimension by isoelectric focusing in the liquid phase using the Off-Gel device producing 15 fractions. As peptides are separated by their isoelectric point in the first dimension and hydrophobicity in the second, those experimentally derived parameters (pI and R(T)) can be used for the validation of potentially identified peptides. We applied this strategy to a cellular extract of Drosophila Kc167 cells and identified peptides with two different database search engines, namely PHENYX and SEQUEST, with PeptideProphet validation of the SEQUEST results. PHENYX returned 7582 potential peptide identifications and SEQUEST 7629. The SEQUEST results were reduced to 2006 identifications by validation with PeptideProphet. Validation of the PeptideProphet, SEQUEST and PHENYX results by pI and R(T) parameters confirmed 1837 PeptideProphet identifications while in the remainder of the SEQUEST results another 1130 peptides were found to be likely hits. The validation on PHENYX resulted in the fixation of a solid p-value threshold of <1 x 10(-04) that sets by itself the correct identification confidence to >95%, and a final count of 2034 highly confident peptide identifications was achieved after pI and R(T) validation. Although the PeptideProphet and PHENYX datasets have a very high confidence the overlap of common identifications was only at 79.4%, to be explained by the fact that data interpretation was done searching different protein databases with two search engines of different algorithms. The approach used in this study allowed for an automated and improved data validation process for shotgun proteomics projects producing MS/MS peptide identification results of very high confidence.  相似文献   

19.
A high throughput process including subcellular fractionation and multiple protein separation and identification technology allowed us to establish the protein expression profile of human fetal liver, which was composed of at least 2,495 distinct proteins and 568 non-isoform groups identified from 64,960 peptides and 24,454 distinct peptides. In addition to the basic protein identification mentioned above, the MS data were used for complementary identification and novel protein mining. By doing the analysis with integrated protein, expressed sequence tag, and genome datasets, 223 proteins and 15 peptides were complementarily identified with high quality MS/MS data.  相似文献   

20.
We introduce the computer tool “Know Your Samples” (KYSS) for assessment and visualisation of large scale proteomics datasets, obtained by mass spectrometry (MS) experiments. KYSS facilitates the evaluation of sample preparation protocols, LC peptide separation, and MS and MS/MS performance by monitoring the number of missed cleavages, precursor ion charge states, number of protein identifications and peptide mass error in experiments. KYSS generates several different protein profiles based on protein abundances, and allows for comparative analysis of multiple experiments. KYSS was adapted for blood plasma proteomics and provides concentrations of identified plasma proteins. We demonstrate the utility of the KYSS tool for MS based proteome analysis of blood plasma and for assessment of hydrogel particles for depletion of abundant proteins in plasma. The KYSS software is open source and is freely available at http://kyssproject.github.io/.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号