首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Electrochemical impedance spectroscopy (EIS) is a widely used technique for probing bioaffinity interactions at the surfaces of electrically conducting polymers. EIS methods can be employed to investigate 'labeless' detection of analytes via impedimetric transduction. This paper describes the development of a direct immunosensor for the detection of a cell-surface protein on Listeria monocytogenes, an extremely important food-borne pathogen. L. monocytogenes are facultative anaerobic, non-sporing, Gram-positive, motile rods that employ the surface bound protein, Internalin B (InlB), to promote invasion into host cells. A recombinant form of InlB was previously cloned and expressed in Escherichia coli and a panel of antibodies and antibody fragments directed against the protein were also produced. Here, we describe how a portion of the recombinant InlB protein, the F3 fragment, and an anti-InlB polyclonal antibody, were used to develop a platform for the labeless immunosensing of InlB. Sensors were fabricated by electropolymerisation of planar screen-printed carbon electrodes with polyaniline (PANI), to produce a conductive substrate. Polyclonal anti-InlB antibody was subsequently incorporated onto the PANI layer using a biotin-avidin system for site-specific immobilisation. The sensors were then probed with varying concentrations of InlB antigen and the impedimetric response at each concentration was recorded. An anti-IgG antibody was immobilised at the electrode surface, as a control and subsequently exposed to the same concentrations of InlB. Impedimetric data for the control sensors were also recorded. Upon exposure to a range of concentrations of antigen, complex plane impedance analyses were used to relate the differing redox states of the polymer layer, to the possible charge transfer at the surface, with respect to the related mechanisms between the antibody and the polymer. These effects were subsequently monitored to assess the impedance of the polymer thereby determining the amount of bound antigen at the sensor surface. Calibration profiles for both sample (InlB) and control (IgG) sensors were constructed. A limit of detection of 4.1 pg/ml was achieved for Internalin B.  相似文献   

2.
A biosensor for the serum cytokine, interleukin-12 (IL-12), based upon a label-free electrochemical impedance spectroscopy monitoring is described. Overexpression of IL-12 has been correlated to the diagnosis of multiple sclerosis (MS). The prototype biosensor was fabricated on a disposable gold-coated silver ribbon electrode by immobilizing anti-IL-12 monoclonal antibodies (mAbs) onto the surface of the electrode. This technique was advantageous as the silver electrodes provided a more rigid and conductive substrate than thin gold foil electrodes and helped in obtaining more reproducible data when used with the electrode holder. Results indicate that IL-12 can be detected at physiological levels, <100 fM with p<0.05 in a label-free and real-time manner. The cost-effective approach described here can be used for diagnosis of diseases (like MS) with known biomarkers in body fluids and for monitoring physiological levels of biomolecules with healthcare, food, and environmental relevance.  相似文献   

3.
A sonochemically fabricated alcohol oxidase enzyme micro-electrode array is reported. Sensors of this type were fabricated by first depositing an insulating polydiaminobenzene film on supporting gold electrodes. Sonication and subsequent ablation exposed discrete areas of the underlying conducting electrode, which collectively act as a microelectrode array. Electropolymerisation of aniline has been used to generate in situ polyaniline containing entrapped alcohol oxidase. The physical and electrochemical properties of these films were studied and reported within this paper. The final composites were shown to behave with microelectrode performance characteristics for the detection of aqueous ethanol concentrations.  相似文献   

4.
Ultrasensitive DNA hybridization biosensor based on polyaniline   总被引:1,自引:0,他引:1  
Ultrasensitive DNA hybridization biosensor based on polyaniline (PANI) electrochemically deposited onto Pt disc electrode has been fabricated using biotin-avidin as indirect coupling agent to immobilize single-stranded 5'-biotin end-labeled polydeoxycytidine (BdC) probes and 5'-biotin end-labeled 35 base-long oligonucleotide probe (BdE) to detect complementary target, using both direct electrochemical oxidation of guanine and redox electroactive indicator methylene blue (MB), respectively. These polyaniline-based disc electrodes have been characterized using differential pulse voltammetry (DPV), Fourier transform infrared spectroscopy (FT-IR), impedance measurements and scanning electron microscopy (SEM) techniques, respectively. Compared to direct electrochemical oxidation of guanine, hybridization detection using MB results in the enhanced detection limit by about 100 times. These DNA immobilized PANI electrodes have hybridization response time of about 60 s.  相似文献   

5.
Sensitivity of Anthrax protective antigen (PA) detection has been improved by directly immobilizing a PA-specific peptide onto a multi-wall carbon nanotube (MWCNT). The MWCNT was covalently immobilized onto a polyaniline (PANI) electrode, which was prepared via electropolymerization of the aniline monomer onto a glassy carbon electrode (GCE). Then, the PA-specific peptide was covalently immobilized to the MWCNT layer for measurement. When comparing this technique to that of PA immobilization on an insulting self assembled organic layer, the advantages of the MWCNT are clear. The MWCNT sensor resulted in enhanced electron transfer across the sensing layer. The resulting limit of detection (LOD) was 0.4 pM, a 13-fold improvement over that of our previous self-assembled organic layer was used for immobilization of the same peptide. Neither positive nor negative interferences were observed when a sample containing both 100 pM PA and bovine serum albumin (BSA) was measured, indicating good selectivity of the proposed sensor.  相似文献   

6.
Polyaniline (PANI) is considered as one of the most fascinating conductive polymers in fabricating enzyme-based biosensors. Nevertheless, to improve both sensitivity and stability of the PANI-modified biosensor has been and continues to be a technical challenge. In this study, we have electrochemically synthesized the PANI film on a platinum (Pt) electrode and then used this electrode to construct a horseradish peroxidase (HRP)-based biosensor for the detection of hydrogen peroxide (H(2)O(2)). The electrochemical and structural properties of electrodes were characterized with scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier-transform infrared (FTIR) spectrophotometer, and cyclic voltammetry (CV). It was interestingly found that the PANI film synthesized in the presence of bovine serum albumin (BSA) has provided the electrode with enhanced sensitivity and excellent stability. Our results suggested that the embedded BSA might serve as an initial template for aniline polymerization and stabilized the microstructure of the PANI film significantly. The constructed HRP/PANI(BSA)/Pt electrode also exhibited a fine linear correlation with H(2)O(2) concentration. This approach by implanted BSA was useful for improving the sensitivity and stability of PANI-modified biosensor.  相似文献   

7.
This study describes the fabrication and performance of an endothelial cell compatible, optically thin, indium tin oxide (ITO) microimpedance biosensor. The biosensor was constructed by sputtering a thin insulating layer of silicon nitride (Si(3)N(4)) onto a 100 nm thick ITO layer. Indium tin oxide electrodes were formed by chemically etching 250 or 500 microm diameter holes through the Si(3)N(4) insulating layer. The exposed ITO electrode was electrically connected to an ITO counter electrode, approximately 2 cm(2) in area, via a 400 microL well containing cell culture media. A lock-in amplifier circuit monitored the impedance of porcine pulmonary artery endothelial cells (PPAECs) cultivated on the electrodes as a function of frequency, between 10 and 100 kHz, and as a function of time, at 5.62 kHz. The ITO-Si(3)N(4) microelectrodes provided consistent and repeatable impedance measurements to the attachment and spreading of PPAECs. In addition, the ITO-Si(3)N(4) electrodes were recyclable, robust, resistant to ethanol sterilization, and had a high optical transmittance. Most importantly, the ITO-Si(3)N(4) electrodes allowed optical access for dynamic cellular attachment imaging. The 5.62 kHz time dependent cellular impedance response to the drug Cytochalasin D further demonstrated the feasibility of using this electrode configuration for dynamic cellular impedance studies.  相似文献   

8.
Polyaniline protected gold nanoparticles (PPAuNPs) were electrophoretically deposited onto a gold electrode, and utilized to fabricate an electrochemical cortisol biosensor. Cortisol specific monoclonal antibody (C-Mab) was covalently immobilized onto the surface of a PPAuNP/Au electrode using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) chemistry. BSA was employed for blocking nonspecific adsorption on the electrode surface. PPAuNP formation and BSA/C-Mab/PPAuNP/Au electrode fabrication were characterized using transmission electron microscopy, atomic force microscopy and electrochemical impedance techniques, respectively. Cyclic voltammetry and differential pulse voltammetric techniques were used to determine the cortisol concentration in a phosphate buffer saline (PBS) solution. Results confirmed that the PPAuNP based electrode was stable during repeated scans and exhibited repeatable redox peaks. Further, the BSA/C-Mab/PPAuNP/Au electrode in the PBS buffer accurately detected cortisol in the range of 1 pM-100 nM with a sensitivity of 1.63 μAM(-1). The biosensor was found to be selective against BSA and 17-α-hydroxy progesterone. This research establishes the feasibility of using a PPAuNP based matrix for a label and mediator free electrochemical biosensor for cortisol, a stress biomarker.  相似文献   

9.
A simple and novel electrochemical biosensor based approach is described for differentiating between differing species of fish on the basis of DNA hybridisation events. Screen-printed carbon electrodes modified with a variety of polymers were used to immobilise commercially available DNA in a single-stranded form. AC impedimetric measurements were firstly carried out on these systems and then upon exposure to single-stranded DNA solutions. When the electrode and solution DNA were complementary, a large drop in impedance was measured; this did not occur for non-matching DNA exposures. DNA hybridisation sensors for closely related species of fish were in the first instance developed as a demonstration for this approach. Species of fish such as herrings and salmon could be differentiated by this method. This sensor format offers great promise for many DNA hybridisation applications and lends itself to mass fabrication due to the simplicity and inexpensiveness of the materials and methods used. The hybridisation results were confirmed by use of ellipsometry to measure the characteristics of similar films deposited on silicon substrates.  相似文献   

10.
A polymer-modified sonochemically fabricated glucose oxidase microelectrode array with microelectrode population densities of up to 2.5 x 10(5) microelectrodes per square centimetres is reported. These microelectrode sensors were formed by first depositing an insulating film on commercial screen printed electrodes which was subsequently sonicated to form cavities of regular sizes in the film. Electropolymerisation of aniline at the microelectrode cavities formed polyaniline protrusions containing entrapped glucose oxidase. Chemical deposition of polysiloxane from dichlorodimethysilane was used to deposit a thin protective and diffusion mass transport controlling coating over the electrodes. The physical and electrochemical properties of these films were studied. The performance of the final glucose oxidase based microelectrode sensor array is reported.  相似文献   

11.
The evolution in impedance at the electrode-skin interface of Beckman and Red Dot electrodes was assessed during long-term recordings. Impedance was measured between each pair of electrodes, arranged in a bipolar configuration on tibialis anterior (n=13). A waveform constructed of sinusoids of known frequencies, evenly distributed on a log scale from 1-16,384 Hz, was applied through the electrodes, and the result recorded by a DAQ system. SEMG signals were recorded at 1000 Hz during isometric dorsiflexion contractions of 30 s, performed every 15 min for 2 h. Impedance data were acquired at 65,536 Hz immediately before and after SEMG recordings. Large individual differences in impedance levels were observed at low frequencies. At high frequencies, impedance values depended only on the electrode type. Impedance decreased steadily with time for Beckman electrodes (p < 0.05), but did not decrease significantly for Red Dot electrodes. The magnitude of the reduction over time varied widely between individuals, and was related to the initial impedance values. The impedance-bandwidth product remained constant for each electrode type (95% confidence intervals 146.2-148.2 and 126.1-127.8 for Beckman and Red Dot electrodes respectively). When skin impedance is electrically modelled with a simple network containing a resistor and a capacitor, the capacitance varies with the properties of the electrode used, whereas resistance is dependent on the subject. Furthermore, the EMG spectrum is unaffected by impedance provided skin preparation is sufficient to reduce the impedance below 55 komega.  相似文献   

12.
An open question in the literature of nitric oxide detection was investigated: does electrochemical activation account for the enhanced properties of certain presumed chemically-modified electrodes? Uniform electrodes of graphite, iridium, palladium, platinum, and ruthenium were exposed to potential cycling and then tested for amperometric response to nitric oxide to identify principles that govern electrochemical activation of nitric oxide electrodes. These electrodes were compared to similar electrodes that were not cycled. Only cycled graphite and ruthenium showed significantly increased responses. Graphite demonstrated enhanced performance after exposure to cycling potentials at which oxygen, CO2, and soluble carbonates form, suggesting that erosion of the electrode enhanced its response by increasing the surface area accessible to nitric oxide. This may explain the performance of carbon fibers cycled to the same potentials in solutions containing metalloporphyrins. The response of ruthenium was enhanced after cycling to less extreme potentials at which soluble species do not form and at which a metallic conductive oxide, RuO2, could lay down a stable, adherent layer on the electrode surface. Cycled ruthenium also exhibited a much greater increase in capacitance after cycling, consistent with the formation of a conductive surface layer.  相似文献   

13.
A new current amplified immunosensor for the determination of carcinoembryonic antigen (CEA) was demonstrated in this work. The electrode architecture was fabricated by positively charged toluidine blue (TB) coated on negatively charged poly-sulfanilic acid (PSAA) modified glassy carbon electrode (GCE) surface through electrostatic interactions to form a TB/PSAA film, which provided an interface containing amine groups to assemble gold nanoparticles (nano-Au) for immobilization of carcinoembryonic antibody (anti-CEA) and horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to characterize the electrochemical properties of the modified processes. The CVs reduction current of the immunosensor charged linearly in two concentration ranges of CEA from 0.5 to 5.0 and 5.0 to 120.0 ng/ml in presence of 0.3mM H2O2 in analyte solution, and the detection limit was 0.2 ng/ml at three times background noise. The proposed method is economical, efficient and potentially attractive for clinical immunoassays.  相似文献   

14.
Quantitative electrochemiluminescence (ECL) detection of a model protein, bovine serum albumin (BSA) was achieved via biotin–avidin interaction using an avidin-based sensor and a well-developed ECL system of tris(2,2′-bipyridine) ruthenium(II) derivative as label and tri-n-propylamine (TPA) as coreactant. To detect the protein, avidin was linked to the glassy carbon electrode through passive adsorptions and covalent interaction with carboxylate-terminated carbon nanotubes that was used as binder to immobilize avidin onto the electrode. Then, biotinylated BSA tagged with tris(2,2′-bipyridine) ruthenium(II) label was attached to the prepared avidin surface. After binding of BSA labeled with tris(2,2′-bipyridine) ruthenium(II) derivative to the surface-immobilized avidin through biotin, ECL response was generated when the self-assembled modified electrode was immersed in a TPA-containing electrolyte solution. Such double protein labeling protocol with a biotin label for biorecognition and ruthenium label for ECL detection facilitated the detection of protein compared to the classical double antibody sandwich format. The ECL intensity was linearly proportional to the feed concentration of BSA over two orders of magnitude in the range of 15 nM to 7.5 μM. The detection limit was estimated to be 1.5 nM. Further application to the lysozyme analysis was carried out to validate the present approach for an effective and favorable protocol for the quantitative detection of proteins. The dynamic range of lysozyme was from 0.001 g L−1 to 0.1 g L−1 and the detection limit was 0.1 mg L−1. Electrochemical impedance and cyclic voltammetric measurements along with some necessary control experiments were conducted to characterize the successful formation of self-assembled modified electrodes and to grant the whole detection process.  相似文献   

15.
Gold electrodes modified by nanogold aggregates (nanogold electrode) were obtained by the electrodeposition of gold nanoparticles onto planar gold electrode. The Electrochemical response of single-stranded DNA (ssDNA) probe immobilization and hybridization with target DNA was measured by cyclic voltammograms (CV) using methylene blue (MB) as an electroactive indicator. An improving method using long sequence target DNA, which greatly enhanced the response signal during hybridization, was studied. Nanogold electrodes could largely increase the immobilization amount of ssDNA probe. The hybridization amount of target DNA could be increased several times for the manifold nanogold electrodes. The detection limit of nanogold electrode for the complementary 16-mer oligonucleotide (target DNA1) and long sequence 55-mer oligonucleotide (target DNA2) could reach the concentration of 10(-9) mol/L and 10(-11) mol/L, respectively, which are far more sensitive than that of the planar electrode.  相似文献   

16.
There is continued interest in the development of conductive polymer coatings to improve the electrical properties and biocompatibility of electrodes for neural prostheses. We present here a new type of coating, based on mixed self-assembled monolayers (SAMs) of thiolated poly(alkylthiophene)s and functionalized alkanethiols. When assembled as a SAM on electrodes designed for in vitro electrophysiology, these polymers are able to significantly lower electrode impedance at 1 kHz. The same mixed formulation is able to promote the outgrowth of neurites from primary mouse cortical neurons when the alkanethiol component is functionalized with a neural cell adhesion molecule (NCAM) binding antibody. Atomic force microscopy of the SAMs shows that they exert their effect through the well-known mechanism of increasing electrode surface area. These new covalently bound films have the potential to be more robust and are more controllable in their composition than existing electrodeposited conductive polymer coatings.  相似文献   

17.
This study was conducted to monitor the electrochemical responses of two proteins (bovine serum albumin (BSA) and gelatin) and their thiol derivatives adsorbed onto gold (Au) electrodes, which were analyzed by a "nonlinear" impedance method. A sinusoidal voltage is applied to a protein-containing aqueous solution and the waveform of the output current is analyzed by fast Fourier transformation (FFT). The intensities of the higher harmonics in the FFT varied with the species of protein and their thiol derivatives, and with time. From the higher harmonics, voltage-dependent capacitance and conductance were quantitatively evaluated to differentiate the state of adsorbed protein. Adsorption and desorption characteristics of BSA and its thiol derivative on the Au surface were continuously measured by a quartz crystal microbalance (QCM) in situ. The microscopic state of thiol-derivatized BSA adsorbed onto the Au surface was imaged by atomic force microscopy (AFM). In general, thiol-derivatized proteins were tightly adsorbed on the Au surface and showed no desorption. The present electrochemical measurements clearly differentiated adsorption characteristics of physically adsorbed (physisorbed) and chemically adsorbed (chemisorbed) proteins on Au surfaces.  相似文献   

18.
The protein-resistant polycationic graft polymer, poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG), was uniformly adsorbed onto a homogenous titanium surface and subsequently subjected to a direct current (dc) voltage. Under the influence of an ascending cathodic and anodic potential, there was a steady and gradual loss of PLL-g-PEG from the conductive titanium surface while no desorption was observed on the insulating silicon oxide substrates. We have implemented this difference in the electrochemical response of PLL-g-PEG on conductive titanium and insulating silicon oxide regions as a biosensing platform for the controlled surface functionalization of the titanium areas while maintaining a protein-resistant background on the silicon oxide regions. A silicon-based substrate was micropatterned into alternating stripes of conductive titanium and insulating silicon oxide with subsequent PLL-g-PEG adsorption onto its surfaces. The surface modified substrate was then subjected to +1800 mV (referenced to the silver electrode). It was observed that the potentiostatic action removed the PLL-g-PEG from the titanium stripes without inducing any polyelectrolyte loss from the silicon oxide regions. Time-of-flight secondary ions mass spectroscopy and fluorescence microscopy qualitatively confirmed the PLL-g-PEG retention on the silicon oxide stripes and its absence on the titanium region. This method, known as "Locally Addressable Electrochemical Patterning Technique" (LAEPT), offers great prospects for biomedical and biosensing applications. In an attempt to elucidate the desorption mechanism of PLL-g-PEG in the presence of an electric field on titanium surface, we have conducted electrochemical impedance spectroscopy experiments on bare titanium substrates. The results showed that electrochemical transformations occurred within the titanium oxide layer; its impedance and polarization resistance were found to decrease steadily upon both cathodic and anodic polarization resulting in the polyelectrolyte desorption from the titanium surface.  相似文献   

19.
In this study we describe the preparation of a colored conductive paint electrode containing In(2)O(3), SnO(2), or TiO(2) for the electrochemical inactivation of marine bacteria. When each colored conductive paint electrode was immersed in seawater containing 10(6) cells/mL for 90 min, marine microbe attachment to the TiO(2)/SnO(2)/Sb electrode surface was minimal. Preparation of electrodes coated with 40% particles is shown to be more cost-effective, and because of their more translucent coatings they can be painted over with bright colors. When a potential of 1.0 V was applied for 30 min to the colored conductive paint electrode (40 wt% TiO(2)/SnO(2)/Sb) in sterile seawater, the survival ratio decreased to 55%. When 1.5 V vs. saturated calomel electrode (SCE) was applied, all attached cells were inactivated. Chlorine was not detected below an applied potential of 1.5 V. A change in pH was not observed in the range of 0 to 1.5 V. This method might be effective for preventing bacterial cell accumulation and the formation of biofilms.  相似文献   

20.
目的 植入式脑机接口在神经疾病的治疗方面已经得到了广泛应用,治疗的效果依赖于与神经组织接触的电极。与刚性材料制作的电极相比,碳基微纤维电极尺度小、生物兼容性好、组织炎症反应小,可以减少植入后的异物反应,改善神经记录信号的信噪比,可以长期保持稳定的电极特性。方法 本文设计了一种柔性碳纳米管(carbon nanotubes,CNTs)纤维电极的修饰方法,该方法采用电化学聚合的方式可以将聚3,4-乙烯二氧噻吩(poly(3,4-ethylenedioxythiophene),PEDOT)薄膜沉积到CNTs纤维电极上,作为微电极涂层。为了证明修饰涂层在电极表面具有良好的机械稳定性,对修饰电极进行了超声处理。此外,本文将PEDOT薄膜沉积到ITO玻璃上,评价了PEDOT薄膜的生物相容性。结果 恒电流方式在CNTs纤维电极表面沉积的PEDOT涂层降低了电极的电化学阻抗,提高了电极的电化学性能,且PEDOT沉积的时间越长阻抗减少的幅度越明显。对电极进行超声处理后,电极的电化学阻抗没有产生显著变化,说明超声处理后PEDOT涂层剥离较少,证明了修饰涂层在电极表面具有良好的机械稳定性。最后,细胞实验表明,PEDOT薄膜具有与ITO导电玻璃相当的细胞相容性。结论 PEDOT薄膜可以提高CNTs纤维电极的稳定性,有望提高脑机接口系统的寿命和可靠性,具有应用于长时间记录神经电信号的前景。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号