首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 394 毫秒
1.
Monitoring and predicting the microclimate in naturally ventilated barns (NVB) is important given the adverse effects of high summer temperatures on dairy cows in the context of global climate change. The aim of the work was to verify the accuracy of the microclimate forecast in a NVB using linear regression (LR). Our working hypothesis suggested that multiple periodic measurements of air temperature and relative humidity outside and inside the barns at the same time will allow us to build LR models for predicting the temperature-humidity index (THI). This was done not only for a specific dairy barn based on this indicator outside, but also in other dairy barns with a similar design, located in similar weather conditions. The results of the research indicate that the use of LR had a high accuracy of forecasting (93–96%) the THI in NVB of various designs during the summer heat. At the same time, differences were found between traits (air temperature, relative humidity as well as resulting THI) provided by meteorological weather stations and these data measured simultaneously next to the dairy barns. The proposed LR models can be used to predict THI in NVBs of different designs.  相似文献   

2.
During 1 year, samples were taken on 4 days, one sample in each season, from pigs, the floor, and the air inside pig barns and from the ambient air and soil at different distances outside six commercial livestock-associated methicillin-resistant Staphylococcus aureus (LA-MRSA)-positive pig barns in the north and east of Germany. LA-MRSA was isolated from animals, floor, and air samples in the barn, showing a range of airborne LA-MRSA between 6 and 3,619 CFU/m(3) (median, 151 CFU/m(3)). Downwind of the barns, LA-MRSA was detected in low concentrations (11 to 14 CFU/m(3)) at distances of 50 and 150 m; all upwind air samples were negative. In contrast, LA-MRSA was found on soil surfaces at distances of 50, 150, and 300 m downwind from all barns, but no statistical differences could be observed between the proportions of positive soil surface samples at the three different distances. Upwind of the barns, positive soil surface samples were found only sporadically. Significantly more positive LA-MRSA samples were found in summer than in the other seasons both in air and soil samples upwind and downwind of the pig barns. spa typing was used to confirm the identity of LA-MRSA types found inside and outside the barns. The results show that there is regular airborne LA-MRSA transmission and deposition, which are strongly influenced by wind direction and season, of up to at least 300 m around positive pig barns. The described boot sampling method seems suitable to characterize the contamination of the vicinity of LA-MRSA-positive pig barns by the airborne route.  相似文献   

3.
The severity of heat stress conditions in high-yielding dairy cows is currently underestimated. The present study aimed to determine the heat load threshold of the temperature-humidity index (THI) on physiological parameters of lactating Holstein-Friesian cows under a continental climatic zone in Germany. Physiological parameter measurements, such as respiration rate (RR), measured hourly, and heart rate (HR) and rectal temperature (RT), both measured twice daily, were performed in a total of 139 multiparous cows on three randomly chosen measurement days per week. In addition, the ambient temperature and relative humidity of the barn were recorded every 5 min to calculate the current THI. The physiological parameter data were linked to the THI, and the heat load thresholds were determined using the broken-stick model. The heat load duration effect of each physiological parameter was obtained by regression analysis. Considering the increases in the physiological parameters, our study provided reliable data to determine heat load thresholds for lactating high-yielding dairy cows in a moderate climatic zone. The heat load threshold could be determined for RR in standing cows (THI = 70) and lying cows (THI = 65) and for HR (THI = 72) and RT (THI = 70) in standing cows. The heat load duration also demonstrated a significant effect on the increases in physiological parameters among dairy cows. In particular, the present study enabled a strategy to be devised to initiate heat mitigation in high-yielding dairy cows when they are exposed to THIs above 65.  相似文献   

4.
The dairy industry in regions with moderate climates, such as Central Europe, will be increasingly challenged in the future by climate change. The problem of heat stress will especially affect dairy husbandry in naturally ventilated barns (NVB). The approach of the study was to determine a heat stress threshold of the average daily temperature-humidity index (THI) that results in changes in the daily rumination time (RT) of lactating, high-yielding cows. The data set was composed of a high sample size of 183 cows and long-duration measurements of 21240 daily observations over two years from June 2015 to May 2017, which were collected in an NVB in Groβ Kreutz, Germany. The THI was calculated in 5-min intervals by data from several sensors in different positions inside the barn. Additionally, every cow from the herd of an average of 53 cows in the experimental procedure was wearing a neck collar with a Lely Qwes HR system that provided the RT 24 h a day (12 2-h recordings were summarized). The study showed that heat stress also negatively influenced RT in moderate climates. The heat stress threshold of 52 THI was determined by broken-stick regression and indicated changes of RT of lactating dairy cows in Germany. During the experimental period, the heat stress threshold for RT was reached from April to September for up to 720 h per month. The changes in RT to the heat stress threshold will be affected by cows' characteristics. Therefore, we considered several cow-related factors, such as milk yield (MY), lactation number (LN), lactation stage (days in milk, or DIM) and pregnancy stage (P) to better understand cows’ individual reactions to heat stress. Multiparous, high-yielding cows in later lactation stages are potentially more strongly affected than other cows.  相似文献   

5.
With international demand for production systems aimed at thermal comfort and animal welfare, milk producers have become increasingly interested in compost barns. However, doubts about the behavioral aspects of cows in tropical and subtropical climates remain, because the compost barn system offers a larger bed area per animal at a lower stocking rate. The objective of this study was to evaluate whether the diurnal behaviors, hygiene and lameness of crossbred dairy cows are influenced by different number of lactations when housed in a compost-bedded pack barn system under hot and humid conditions. Crossbred cows (Holstein and Jersey), which were divided into two treatments based on number of lactations (primiparous and multiparous cows), were evaluated during lactation (n=12). The study was conducted from September 2015 to February 2016 in a compost barn in the southwest region of the state of Paraná, Brazil. Daytime behavior was observed between milking schedules using focal observations with 0/1 sampling. Cow hygiene and lameness were evaluated using subjective scores ranging from 1 to 4 and 1 to 5, respectively. Animal behavior and welfare was analyzed using Bayesian inference with a mixed effects model. The probabilities of dyspnea and pushing behaviors were higher (P<0.05) in multiparous cows, and the probability increased during the hottest hours of the day. For both multiparous and primiparous cows, the agonistic behaviors of pushing, butting and chasing peaked during the afternoon. Eating behaviors had the highest likelihood values (0.8 at 0800 h). The cows preferred to remain lying down in the morning, while rest and standing rumination were preferred in the afternoon. Primiparous cows were cleaner than multiparous cows, and the hygiene score for this group was significantly lower (P<0.05). The hygiene and lameness scores for all animals were low, and the highest scores were 1 and 2. In conclusion, multiparous cows exhibited more frequent agonistic behaviors during the hottest hours of the day. Regarding hygiene and lameness scores, multiparous cows exhibited a higher degree of dirtiness compared with the primiparous cows.  相似文献   

6.
In epidemiological studies, outdoor exposure to pollen is typically estimated using rooftop monitoring station data, whilst exposure overwhelmingly occurs at street level. In this study the relationship between street level and roof level grass pollen concentrations was investigated for city centre street canyon environments in Aarhus, Denmark, and London, UK, during the grass pollen seasons of 2010 and 2011 respectively. For the period mid-day to late evening, street level concentrations in both cities tended to be lower than roof-level concentrations, though this difference was found to be statistically significant only in London. The ratio of street/roof level concentrations was compared with temperature, relative humidity, wind speed and direction, and solar radiation. Results indicated that the concentration ratio responds to wind direction with respect to relative canyon orientation and local source distribution. In the London study, an increase in relative humidity was linked to a significant decrease in street/roof level concentration ratio, and a possible causative mechanism involving moisture mediated pollen grain buoyancy is proposed. Relationships with the other weather variables were not found to be significant in either location. These results suggest a tendency for monitoring station data to overestimate exposure in the canyon environment.  相似文献   

7.
赵圣菊 《生态学报》1981,1(4):315-326
我国位于盛行的东亚季风区域内,季节变化明显。粘虫(Mythimna separata Walker)远距离北迁南回,与东亚地区低层大气环流季节性变化有着密切的关系。因此根据诱蛾资料和气象观测记录,着重对我国粘虫的迁飞方向、迁飞高度、迁飞界限、起飞降落条件以及虫源基地等问题进行分析,绘制我国粘虫迁飞路径图,是十分必要的。  相似文献   

8.
为了探明我国西南稻区褐飞虱早期迁入种群的虫源地,为后期预测和防治提供依据,通过对2007—2016年云南植保站4—5月份褐飞虱虫情进行分析,选取出云南省勐海、芒市、江城、师宗、麻栗坡、广南6个代表性站点,利用WRF-FlexPart耦合模式对2013年、2015年和2016年这些站点的早期迁入峰进行了数值模拟,得到近年来云南省褐飞虱早期迁入虫源的虫源地。选取了2013年褐飞虱早期迁入量较大的迁入峰进行了大气背景分析,结合峰期影响褐飞虱迁飞的大气动力场、温度场和相对湿度场,探讨了影响云南省褐飞虱早期迁入的大气背景。研究结果表明:(1)近年来云南省褐飞虱迁入的虫源主要来自缅甸,部分来自老挝和泰国,少数来自越南,还有极少量来自孟加拉国。(2)这一时期,当释放高度分别为1500、2000 m时,褐飞虱的迁飞高度分别集中在2216 m和2489 m,平均迁飞高度分别是2167、2454 m,从不同释放高度回推的褐飞虱迁飞高度的起伏趋势具有较好的一致性,表明模式能较好地反映系统性垂直气流和下垫面起伏对其上层三维流场和种群迁飞的影响。(3)选取2013年5月22—26日发生在云南勐海、麻栗坡和广南的一次典型褐飞虱迁入过程,分析了大气背景场对褐飞虱迁飞的影响,结果显示:受印缅低压控制或影响,高空从境外虫源区至云南降虫区有西南水平气流作为种群输送动力;温场在降虫区东北侧有"低温屏障墙"存在,阻止了种群的继续北迁;垂直速度场上虫源区有上升气流促使种群起飞迁出,降虫区有下沉气流促使种群降落;弱降水形成的拖曳下沉气流对降虫也十分有利;相对湿度场对此次迁飞过程不形成任何胁迫。  相似文献   

9.
A better understanding of how livestock respond to weather is essential to enable farming to adapt to a changing climate. Climate change is mainly expected to impact dairy cattle through heat stress and an increase in the frequency of extreme weather events. We investigated the effects of weather on milk yield and composition (fat and protein content) in an experimental dairy herd in Scotland over 21 years. Holstein Friesian cows were either housed indoors in winter and grazed over the summer or were continuously housed. Milk yield was measured daily, resulting in 762 786 test day records from 1369 individuals, and fat and protein percentage were sampled once a week, giving 89 331 records from 1220 cows/trait. The relative influence of 11 weather elements, measured from local outdoor weather stations, and two indices of temperature and humidity (THI), indicators of heat stress, were compared using separate maximum likelihood models for each element or index. Models containing a direct measure of temperature (dry bulb, wet bulb, grass or soil temperature) or a THI provided the best fits to milk yield and fat data; wind speed and the number of hours of sunshine were most important in explaining protein content. Weather elements summarised across a week’s timescale from the test day usually explained milk yield and fat content better than shorter-scale (3 day, test day, test day −1) metrics. Then, examining a subset of key weather variables using restricted maximum likelihood, we found that THI, wind speed and the number of hours of sunshine influenced milk yield and composition. The shape and magnitude of these effects depended on whether animals were inside or outside on the test day. The milk yield of cows outdoors was lower at the extremes of THI than at average values, and the highest yields were obtained when THI, recorded at 0900 h, was 55 units. Cows indoors decreased milk yield as THI increased. Fat content was lower at higher THIs than at intermediate THIs in both environments. Protein content decreased as THI increased in animals kept indoors and outdoors, and the rate of decrease was greater when animals were outside than when they were inside. Moderate wind speeds appeared to alleviate heat stress. These results show that milk yield and composition are impacted at the upper extreme of THI under conditions currently experienced in Scotland, where animals have so far experienced little pressure to adapt to heat stress.  相似文献   

10.
In two consecutive summers, 21 and 18 cows, respectively, were monitored for blood parameters and milk yield, to assess their variation according to the level of heat stress at different stages of lactation. During both years, the cows were monitored according to their lactation phase (early, mid-, and late) at the beginning of the summer. Climatic conditions were described through the temperature humidity index. Cows were monitored for breathing rate, rectal temperature, blood metabolites and enzymes, and milk yield. In the first year, two hotter periods were identified, with more severe conditions in the second one, when cows had rectal temperatures higher than 40°C. In the second year, only one hotter period was identified, with a heat stress comparable to that of the first period of the first year. Milk yield declined during the hotter period; in both years, a higher reduction in milk yield was recorded for cows in the mid-stage of lactation. The decrease in plasma glucose during the hotter period was evident in both years. Plasma cholesterol also decreased in those periods. The reduction in plasma ALP activity in the hotter period of both years confirmed the role of this enzyme as a quick and reliable heat-stress blood marker.  相似文献   

11.
孙武  沈子桐  乔志强  孙靓  张佳滨  张坤  许伟 《生态学报》2021,41(7):2632-2641
以22 km×21 km的广州主城区为例,以40 m建筑间距作为风道宽度低限、用容积高度对建筑高度赋值和垂向拔高为建模特色,概括构建了城市尺度的立体模型。在此基础上,分别模拟了广州主城区中性流条件下,弱风(2 m/s)和强风(5 m/s)、近地面10、25、50 m三个高度的风环境。模拟表明:来流5 m/s下主城区存在不同风速等级、不同平面形态以及不同高度面的风道;白云山、珠江新城等面积较大的地形或建筑高地形成了减速明显的背风区条带,并相互组合形成了重要的风口和具有较高基面的强风道;在不同高度上主城区风速均由周边向城市中心降低;风道风速强烈地依赖于风道走向,风道风速与走向夹角呈三次函数递减,两者拟合优度R2为0.512。模拟结果很好地呈现了城市尺度宏观地形白云山和建筑密集区相互间的作用,反映了城市尺度模型构建与模拟的优势。  相似文献   

12.
H2S, PM2.5, O3, NO2, SO2 and meteorological parameters such as temperature, relative humidity, precipitation, wind speed and wind direction were measured simultaneously in an eastern Croatian town called Slavonski Brod during the season winter/spring 2010. Emissions from the nearby cross-border (Bosnia and Herzegovina) oil refinery were identified as sources of temporary elevated concentrations of H2S. The maximum daily averages of PM2.5 concentrations during the winter period were as high as 240 microg m(-3) which is a value 10 times greater than the threshold prescribed by the World Health Organization. It is considered that the heating season, dense traffic, intense industrial activities and temperature inversion during stable weather conditions are prevailing contributors to higher winter concentrations of PM2.5. The results of the principal component analysis technique (PCA) have shown that lower air temperature, lower wind speed and higher relative humidity play a significant role in the winter pollution episodes. From a public health point of view, implementation of measures aimed at reducing the levels of H2S and PM2.5 should be considered.  相似文献   

13.
Eight days of September 1985 were spent in a Swiss high-altitude meteorological station. The main facts apparent in this study at the end of summer are a great cold, with a long duration of below zero; sometimes, a severe dryness, decreasing to 1% of relstive humidity but also nearing 99%; a very high wind, blowing to 17 m/s at the maximum; and a considerable variability of these parameters in a very short time. A comparison is made with two nearby, lower altitude stations. The consequences for human confort are also considered.  相似文献   

14.
Avian influenza virus-infected poultry can release a large amount of virus-contaminated droppings that serve as sources of infection for susceptible birds. Much research so far has focused on virus spread within flocks. However, as fecal material or manure is a major constituent of airborne poultry dust, virus-contaminated particulate matter from infected flocks may be dispersed into the environment. We collected samples of suspended particulate matter, or the inhalable dust fraction, inside, upwind and downwind of buildings holding poultry infected with low-pathogenic avian influenza virus, and tested them for the presence of endotoxins and influenza virus to characterize the potential impact of airborne influenza virus transmission during outbreaks at commercial poultry farms. Influenza viruses were detected by RT-PCR in filter-rinse fluids collected up to 60 meters downwind from the barns, but virus isolation did not yield any isolates. Viral loads in the air samples were low and beyond the limit of RT-PCR quantification except for one in-barn measurement showing a virus concentration of 8.48x104 genome copies/m3. Air samples taken outside poultry barns had endotoxin concentrations of ~50 EU/m3 that declined with increasing distance from the barn. Atmospheric dispersion modeling of particulate matter, using location-specific meteorological data for the sampling days, demonstrated a positive correlation between endotoxin measurements and modeled particulate matter concentrations, with an R2 varying from 0.59 to 0.88. Our data suggest that areas at high risk for human or animal exposure to airborne influenza viruses can be modeled during an outbreak to allow directed interventions following targeted surveillance.  相似文献   

15.
The results of numerical modelling of large-scale circulation in Lakes Onega and Ladoga are presented, with primary emphasis on the temporal variability of currents with time scales of days. Some typical circulation patterns have been inferred from model calculations. They reflect the existence of different dynamic regimes in the lakes, namely, forced and free circulation regimes. The forced circulation regime is the well-known wind-induced double-gyre circulation accompanied by coastal upwelling and downwelling. A case of double-gyre circulation in Lake Onega was investigated in particular detail. The second dynamic regime is a free response (or a relaxation) of the stratified lake to wind cessation, and is connected closely with the evolution of wind-induced upwelling and thermal front propagation. Diagnostic calculations demonstrate that the regime of relaxation supports the restoration of cyclonic circulation in Lake Onega. Barotropic circulation patterns in Lake Ladoga were calculated with the emphasis on prevailing winds from west to south-east. Our calculations show that the bottom relief of Lake Ladoga causes asymmetry in the double-gyre circulation patterns. In particular, approximately equal cyclonic and anticyclonic circulation cells appearing in the case of southerly wind transform to a single dominant cyclonic cell and several small anticyclonic cells in the case of westerly wind. We also found especially strong sensitivity of the sense of rotation of the largest gyre to the east-west components of the wind vector.  相似文献   

16.
The prevalence and seasonal variations of infection by Coxiella burnetii in cattle were investigated seroepidemiologically on a farm in Hokkaido, Japan, by an immunofluorescent antibody test. A total of 364 serum samples from 28 cows were collected from August 1993 to October 1995 in two barns on the farm. It was found that the number of antibody-positive cows and their antibody titers were significantly elevated in winter and decreased in summer. In addition, antibodies were detectable in seroconverted cows for about five months.  相似文献   

17.
In this paper airborne pollen concentration is compared to meteorological data of Trento and S. Michele all’Adige, two sites in the Adige Valley, in Trentino (North Italy). Pollen ofCorylus, Alnus, Betula andOstrya, four winter-spring flowering plants are considered. Pollen sampling was carried out in 1996 by volumetric Hirst-type samplers. For all pollen types considered, maximum pollen concentration coincided in both stations and there was a good overlap of the main pollen season length; the pollen curves of S. Michele a/A and Trento showed a highly positive correlation. The daily airborne pollen concentrations, defined as the number of pollen grains per cubic meter of air (P/m3), were compared to daily meteorological data: minimum and maximum air temperature (°C), average relative humidity (%), precipitation (mm), global incident radiation (cal/cm2), average wind direction (°) and wind speed (m/s). A highly positive correlation was found forCorylus and maximum temperature in both monitoring stations.Betula was positively, whereasOstrya was negatively correlated to relative humidity. With this first analytical approach sharp differences in the atmospheric pollen presence between the stations located at Trento and S. Michele all’Adige were not found.  相似文献   

18.
This summer study evaluated the effect of providing additional fans (cooling) in the resting area within a free-stall dairy barn that had fans and sprinklers in the feeding area and paddock availability. Thirty cows were divided into two homogenous groups and kept in two pens: one had the resting area equipped with two fans (FAN) while no fans were added to the other resting area (CON). Microclimatic parameters, rectal temperature (RT), breathing rate (BR), milk yield, and milk pH traits were recorded. Time budgeting and the behaviour of the cows (time spent in the feeding area, standing and lying in other areas) were also recorded using digital video technology. Two slight-to-moderate heat waves were observed. During the hottest period the daily maximum temperature recorded was 33.5 °C and the daily maximum THI was 81.6. During this period, the BR and RT increased only slightly in both groups, with lower BR (n.s.) in FAN compared with CON. Milk yield was better maintained (n.s.) in FAN compared with CON during the hottest period. The FAN cows showed a greater (P?<?0.05) lying time in the free stalls (9.5 and 8.6 h/day in FAN and CON, respectively), whereas CON cows made greater (P?<?0.05) use of the paddock during evening and late evening hours. Consequently, the total daily lying time was 13.5 h/day in both groups. In conclusion, the results suggest that using fans in the resting area improves cow comfort, which increases use of the resting area. The lying time results also suggest that the benefits of providing ventilation in the resting area might be more evident in barns where there is no paddock.  相似文献   

19.
The aim of this study was to determine how evaporative cooling modifies body function with respect to water metabolism and other variables relevant to milk synthesis in crossbred cattle. The study was conducted on two groups of 0.875HF:0.125RS crossbred Holstein cattle (87.5%) housed in an open-sided barn with a tiled roof (non-cooled animals) and in a close-sided barn under an evaporative cooling system (cooled animals). The maximum ambient temperature and relative humidity for the non-cooled group were 33 degrees C and 61%, with the corresponding values for the evaporatively cooled barn being 28 degrees C and 84%, respectively. The temperature humidity index (THI) of under non-cooled conditions was higher (P < 0.05) than that in the cooled barn. Rectal temperatures and respiration rates of non-cooled animals were higher (P < 0.05) than those of cooled animals. Daily dry matter intake (DMI) of cooled animals was higher while water intakes were lower (P < 0.05) than those of non-cooled animals. The mean absolute values of plasma volume, blood volume, and extracellular fluid (ECF) of cooled animals were significantly higher (P < 0.05) than those of non-cooled animals throughout all stages of lactation. Milk yields of cooled animals were higher by 42%, 36% and 79% on average than those of non-cooled animals during early-, mid- and late-lactation, respectively. The decline in milk yields as lactation advances was markedly apparent in late-lactating non-cooled animals, while no significant changes in milk composition at different stages of lactation were observed in either group. Mean arterial plasma concentrations, arteriovenous concentration differences (A-V differences) and the extraction ratio across the mammary gland for acetate, glucose and triglyceride of cooled animals were not significantly different compared with values for non-cooled animals. No differences were seen in plasma hormonal levels for triiodotyronine (T(3)) and insulin-like growth factor-1 (IGF-1), but plasma cortisol and thyroxine (T(4)) levels tended to be lower in non-cooled animals. This study suggests that low cooling temperature accompanied by high humidity influences a galactopoietic effect, in part through increases in ECF, blood volume and plasma volume in association with an increase in DMI, which partitions the distribution of nutrients to the mammary gland for milk synthesis. Cooled animals were unable to maintain high milk yield as lactation advances even though a high level of body fluids was maintained during long-term cooled exposure. The decline in milk yield, coinciding with a decrease in net energy for lactation as lactation advances, could be attributed to a local change within the mammary gland.  相似文献   

20.
ABSTRACT

Some animals emit sounds usable for acoustic monitoring of their population size. Such signals should be loud, omni-directional and easy to recognise and localise. Eurasian Bittern Botaurus stellaris mating calls (booms) are known to be loud and probably omni-directional but there is no data on acoustic localisation of this species. We made recordings of bittern booms with a 4-element GPS-linked microphone array, calibrated for absolute sound pressure level measurements. Receiver spacing was 65 to 294 m. The source level was 101 ± 3 dB re 20 μPa @ 1 m. The source level did not vary more than 7 dB for the same boom recorded at two different locations, with angular separations of 3°-27° as seen from the source. The geometric transmission loss was close to spherical, and the excess attenuation was much smaller than what was expected from the prevailing temperature and humidity conditions. The prevailing wind conditions caused sound velocity variations of up to 3%. The source location error was 104 ± 113 m (mean ± 1 s.d.). The prevalence of large location errors was probably caused by problems of discerning the direct path from multipath arrivals of the signal at the receivers and by sound velocity variations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号