首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 250 毫秒
1.
For investigating effects of chemical stressors to cultured cells, we have developed a quartz crystal microbalance (QCM) system with a micro CCD camera that enables microscopic observations simultaneously with the QCM measurements. Human hepatoma cell line (HepG2) cells were cultured on the collagen coated quartz crystal which has indium tin oxide (ITO) electrodes that enable transmission imaging of the cultured cells by the micro CCD camera during the QCM measurements. Glutaraldehyde (GA) and t-butylhydroperoxide (t-BHP) were used for the chemical stressors. The response of the QCM was monitored and analyzed with the resonance frequency and the resonance resistance (F-R) diagram. At the same time, the photographs of the cells were recorded to observe the morphological change. In the case of GA, the QCM responded in two steps which consisted of the rapid response of the cross-linking reactions and successive decreasing cytoskeletons in the cells. In the case of t-BHP, the response showed two steps. At first, the cells changed their shapes to round, and then the weakened cells were unsticked from the surface.  相似文献   

2.
The processes of adhesion, spreading and proliferation of human mammary cancer cells MCF-7 on two Au electrodes with different surface roughness (R(f) and R(f)=3.2 or 1.1) were monitored and clearly identified with the quartz crystal microbalance (QCM) technique. Analyses of the QCM responses on the resonant frequency shifts (Deltaf(0)) vs. the motional resistance changes (DeltaR(1)) revealed a significant surface-stress effect in the involved courses, in addition to a viscodensity effect and a relatively small mass effect (especially at the smooth electrode). Experiments of fluorescence microscopy, cyclic voltammetry and electrochemical impedance spectroscopy were conducted to investigate the cell population on the electrode vs. the electrode-surface roughness. Simplified equations are deduced to quantitatively evaluate the surface stress, and a novel QCM method for dynamically measuring the surface stress on an electrode in cell-culture course is thus described. It was found that the smoother surface (R(f)=1.1) gave a higher surface stress during cell attachment and less cell population on it than the rougher surface (R(f)=3.2). In addition, real-time QCM monitoring showed on the same electrode the surface stress induced by hepatic normal cells being notably higher than that caused by hepatic cancer cells at cell-attachment stage, suggesting that the surface-stress measurement can exhibit the difference of adhesion-performance between the healthy and ill-behaved cells.  相似文献   

3.
用石英晶体微天平(quartz crystal microbalance,QCM)和活细胞成像技术实时监测人脐静脉内皮细胞(HUVEC)在ITO石英晶体电极上的动态粘附响应过程。在ITO晶体电极上加入不同浓度的HUVEC,测定细胞在QCM上谐振频率以及耗散的实时变化。通过ITO电极与光学显微镜的联用,监测了HUVEC在药物处理前后的动态变化过程。用细胞粘弹性指数(QCM的动态电阻变化与频移变化之比,CVI=ΔR/Δf)表征细胞的粘弹性变化,同时通过活细胞成像技术的联用,实时监测细胞的形态变化。结果表明:细胞浓度为10万个/m L时,细胞在ITO电极上铺展完全且粘弹性最大。抑制剂y-27632和激动剂凝血酶thrombin药物处理细胞前后,在显微镜的实时监测下细胞形态变化不明显,但CVI粘弹性指数变化较大,说明QCM信号比光学信号更为敏感,且在药物筛选方面有有很大的应用前景。  相似文献   

4.
With the goal of developing a quartz crystal microbalance (QCM)-based DNA sensor, we have conducted an in situ QCM study along with fluorescence measurements using oligonucleotides (15-mer) as a model single-stranded DNA (ss-DNA) in two different aqueous buffer solutions; the sequence of 15-mer is a part of iduronate-2-sulphate exon whose mutation is known to cause Hunter syndrome, and the 15-mer is thiolated to be immobilized on the Au-coated quartz substrate. The fluorescence data indicate that the initial immobilization as well as the subsequent hybridization with a complementary strand is hardly dependent on the kind of buffer solution. In contrast, the mass increases deducible from the decrease of QCM frequency via the Sauerbrey equation are 2.7-6.2 and 3.0-4.4 times larger than the actual mass increases, as reflected in the fluorescence measurements, for the immobilization and the subsequent hybridization processes, respectively. Such an overestimation is attributed to the trapping of solvent as well as the formation of quite a rigid hydration layer associated with the higher viscosities and/or densities of the buffer solutions. Another noteworthy observation is the excessively large frequency change that occurs when the gold electrode is deposited in advance with Au nanoparticles. This clearly illustrates that the QCM detection of DNA hybridization is also affected greatly by the surface morphology of the electrode. These enlarged signals are altogether presumed to be advantageous when using a QCM system as an in situ probing device in DNA sensors.  相似文献   

5.
The electroformation of giant vesicles from 1,2-Dimyristoyl-sn-Glycero-3-Phosphocholine (DMPC) was monitored using quartz crystal microbalance with dissipation monitoring (QCM-D) and optical microscopy, simultaneously using a novel sample cell design. A gold-coated QCM crystal was used as one of the electrodes and an Indium–tin-oxide (ITO)-coated glass slide was used as the second electrode for electroformation. Increases in the frequency and decreases in the dissipation were observed immediately upon voltage application between the two electrodes, indicating the loss of lipid from the QCM surface. Concurrently, we observed vesicles on the QCM electrode surface by differential interference contrast (DIC)-optical microscopy. The lipid-coated substrates were measured with AFM at various stages in the electroformation, and a significant change in the morphology of the lipid film was observed. Ellipsometry was used to find the average thickness of lipid film. The QCM data were fitted to a viscoelastic model to determine the viscoelastic properties and time dependence of the film thickness. All methods used to determine film thickness give values in reasonable quantitative agreement. Differences between the methods are consistent with what one might expect due to what is actually measured in the individual techniques. The comparison between mass loss and observed vesicles suggest that the vesicles formed are first localized to the substrate and then slowly released into the solution. By comparing the mass lost from the lipid film, to the total surface area of lipid vesicles observed, it is apparent that only a relatively small fraction of the lipid goes into the production of unilamellar vesicles with sizes detectable with optical microscopy.  相似文献   

6.
Recent applications of quartz crystal resonant sensor technology to monitor cell adhesion and specific ligand interaction processes has triggered the development of a new category of quartz crystal microbalance (QCM) based biosensors. In this study human oral epithelial cells (H376) were cultured on quartz sensors and their response to microspheres investigated in situ using the QCM technique. The results demonstrated that this novel biosensor was able to follow cell-microsphere interactions in real-time and under conditions of flow as would occur in the oral cavity. Unique frequency profiles generated in response to the microspheres were postulated to be due to phases of mass addition and altered cellular rigidity. Supporting microscopic evidence demonstrated that the unique frequency responses obtained to these interactions were in part due to binding between the cell surface and the microspheres. Furthermore, a cellular uptake process, in response to microsphere loading was identified and this, by influencing the rigidity of the cellular cytoskeleton, was also detectable through the frequency responses obtained.  相似文献   

7.
A biofilm reactor was constructed to monitor the long-term growth and removal of biofilms as monitored by the use of a quartz crystal microbalance (QCM) and a novel optical method. The optical method measures the reflectance of white light off the surface of the quartz crystal microbalance electrode (gold) for determination of the biofilm thickness. Biofilm growth of Pseudomonas aeruginosa (PA) on the surface was used as a model system. Bioreactors were monitored for over 6 days. Expressing the QCM data as the ratio of changes in resistance to changes in frequency (DeltaR/Deltaf) facilitated the comparison of individual biofilm reactor runs. The various stages of biofilm growth and adaptation to low nutrients showed consistent characteristic changes in the DeltaR/Deltaf ratio, a parameter that reflects changes in the viscoelastic properties of the biofilm. The utility of white light reflectance for thickness measurements was shown for those stages of biofilm growth when the solution was not turbid due to high numbers of unattached cells. The thickness of the biofilms after 6 days ranged from 48 mum to 68 mum. Removal of the biofilm by a disinfectant (chlorine) was also measured in real time. The combination of QCM and reflectance allowed us to monitor in real time changes in the viscoelastic properties and thickness of biofilms over long periods of time.  相似文献   

8.
The quartz crystal microbalance (QCM) was used to monitor endothelial cell (EC) adhesion on the gold surface of an oscillating quartz crystal contained in a QCM device. A number of parameters were investigated. First, we observed differential QCM O-ring toxicities for ECs. Second, appropriate conditions for cell culture and QCM cell environment were identified that can eliminate large-scale frequency oscillations in the measurements. These artifacts are not due to added cells but originate in the time-dependent evaporation of water. Having eliminated these artifacts, we then demonstrated that the measured steady-state crystal frequency shift, Delta f, and motional resistance shift, DeltaR, were determined by the number of firmly attached ECs requiring trypsinization from the crystal surface. Last, following steady-state attachment of ECs, the EC growth stimulation by fibroblast growth factor was monitored in a continuous fashion by measuring f and R values over a 72 h. period. We observed the Delta f values to increase in a way that reflected the increase in EC number bound to the QCM surface. Following addition of ECs to the QCM, the time-dependent increase in DeltaR can be interpreted in terms of increase by the ECs of the energy dissipation properties of the solution at the solution-gold surface interface. This effect is due to their rapid surface attachment and the elaboration of their cytoskeletal properties. These results indicate that the QCM technique can be used for the study of EC attachment and growth and suggest its potential for the real time study of per unit surface area cell mass distribution dynamics and viscoelastic properties and the cells' responses to stresses or perturbations brought about using biologically active molecules.  相似文献   

9.
In vitro and in situ enzymatic polymerization of polyhydroxyalkanoate (PHA) on two hydrophobic surfaces, a highly oriented pyrolytic graphite (HOPG) and an alkanethiol self-assembled monolayer (SAM), was studied by atomic force microscopy (AFM) and quartz crystal microbalance (QCM), using purified Ralstonia eutropha PHA synthase (PhaC(Re)) as a biocatalyst. (R)-Specific enoyl-CoA hydratase was used to prepare R-enantiomer monomers [(R)-3-hydroxyacyl-CoA] with an acyl chain length of 4-6 carbon atoms. PHA homopolymers with different side-chain lengths, poly[(R)-3-hydroxybutyrate] [P(3HB)] and poly[(R)-3-hydroxyvalerate] [P(3HV)] were successfully synthesized from such R-enantiomer monomers on HOPG substrates. After the reaction, the surface morphologies were analyzed by AFM, revealing a nanometer thick PHA film. The same biochemical polymerization process was observed on an alkanethiol (C18) SAM surface fabricated on a gold electrode using QCM. This analysis showed that a complex sequence of PhaC(Re) adsorption and PHA polymerization has occurred on the hydrophobic surface. On the basis of these observations, the possible mechanisms of the PhaC(Re)-catalyzed polymerization reaction on the surface of hydrophobic substrates are proposed.  相似文献   

10.
We investigate the feasibility of coupling the quartz crystal microbalance (QCM) with magnetic separation for on-line analysis. A flow cell was integrated with QCM and magnetic force for the analysis of magnetic and nonmagnetic samples. The resonant frequency change (Deltaf) of QCM was related to the amount of deposited magnetic nanoparticles. This experiment demonstrates that QCM can be used as an on-line detector for magnetic separation. The QCM also gives a characteristic response of the binding between the streptavidin and biotin labeled on the magnetic nanoparticles. Biotin-labeled magnetic nanoparticles were flowed through a gold electrode of QCM to deposit as a matrix for selective capturing streptavidin. The resonant frequency change of QCM was proportional to the amounts of streptavidin captured by biotin. This technique can provide a simple, economic, and automatic method for on-line detection of biomarkers.  相似文献   

11.
A piezoelectric DNA biosensor was prepared by immobilizing DNA probes on a quartz crystal microbalance (QCM) using a lipid-based method. A QCM electrode was coated with a hybrid bilayer membrane composed of an octadecanethiol monolayer and a lipid monolayer containing biotinylated lipids to establish biotin groups on the electrode surface. A DNA biosensor was prepared by sequentially immobilizing avidin and the biotinylated probe. The DNA biosensor was stable throughout repeated surface regeneration and showed higher sensitivity than that prepared by the conventional chemical method using diimide. We also optimized the surface regeneration conditions and flow rate for flow injection analysis.  相似文献   

12.
A bilirubin imprinted polymer (BIP) was coated on a thiol pretreated Au electrode on a quartz crystal microbalance (QCM) chip. The BIP thin film was synthesized using 4-vinylpyridine (4-Vpy) as the monomer, divinylbenzene (DVB) as the cross-linker, and benzophenone as the initiator. By using a photo-graft surface polymerization technique with irradiation by ultra-violet (UV) light, a thin BIP film was prepared, from which a biomimetic sensor for the detection of bilirubin was developed. The sensor was able to discriminate bilirubin in solution owing to the specific binding of the imprinted sites. The BIP/QCM chip has been repeatedly used for more than 7 months in many continuous experiments. The detection signal of bilirubin from the BIP thin film/QCM was compared with the non-BIP thin film/QCM. Biliverdin, an analogue of bilirubin, was used for comparison. The analogue comparison confirmed the binding specificity of the BIP film toward bilirubin. The selectivity can be as high as 31.2. The effect of pH on the detection of bilirubin is also discussed. With proper solvent for elution and recovery, flow injection analysis (FIA) could be applied to the system. The performance of the BIP/QCM chip was evaluated. A linear calibration of the bilirubin concentration with respect to the frequency shift was successfully obtained. The reproducibility of measurements from the same BIP/QCM chip was confirmed. In addition, repeatability of detection was also confirmed from different BIP/QCM chips. In conclusion, a combined BIP thin film/QCM/FIA method was successfully established for the detection of bilirubin concentration using a molecularly imprinted film.  相似文献   

13.
The quartz crystal microbalance (QCM) technique has been applied to the real time monitoring of endothelial cell (EC) adhesion and spreading on the QCM gold surface. We previously showed that the measured QCM Deltaf and DeltaR shifts were due to cells adhering to the gold crystal surface, requiring proteolytic enzyme treatment to be removed from the surface, in order for the Deltaf and DeltaR shifts to return to zero. In the present report, we demonstrate the quantitative dependence and saturation of the measured Deltaf and DeltaR shifts on the number of firmly attached ECs as measured by electronic counting of the cells. We demonstrate through a light microscope simulation experiment that the different Deltaf and DeltaR regions of the QCM temporal response curve correspond to the incident ECs contacting the surface, followed by their adhesion and spreading, which reflect cellular mass distribution and cytoskeletal viscoelasticity changes. Also, we demonstrate that the dose response curve of Deltaf and DeltaR values versus attached EC number is more sensitive and possesses less scatter for the hydrophilically treated surface compared to the native gold surface of the QCM. For both surfaces, a Deltaf and DeltaR versus trypsinized, attached EC number plot 1 h post-seeding exhibits a sigmoid curve shape whereas a similar plot 24 h post-seeding exhibits a hyperbolic curve shape. This number dependence suggests cell-cell cooperativity in the initial cell adhesion and spreading processes. These QCM data and our interpretation are corroborated by differences in cell appearance and spreading behavior we observed for ECs in a light microscope fluorescence simulation experiment of the cell density effect. For a stably attached EC monolayer at 24 h post-addition, steady-state Deltaf and DeltaR values are higher and exhibit saturation behavior for both the hydrophilically treated gold surface as compared to the untreated surface. The steady-state 24 h Deltaf and DeltaR values of stably attached ECs are shifted from the 1 h attached ECs. The 24 h values are characteristic of a more energy-dissipative structure. This is consistent with the time-dependent elaboration of surface contacts in anchorage-dependent ECs via the attachment of intregrins to underlying extracellular matrix. It is also in agreement with the known energy dissipation function of the ECs that cover the interior of blood vessels and are exposed to continuous pulsatile blood flow.  相似文献   

14.
A novel piezoelectric method for DNA point mutation detection based on DNA ligase reaction and nano-Au-amplified DNA probes is proposed. A capture probe was designed with the potential point mutation site located at the 3' end and a thiol group at the 5' end to be immobilized on the gold electrode surface of quartz crystal microbalance (QCM). Successive hybridization with the target DNA and detection probe of nano-Au-labeled DNA forms a double-strand DNA (dsDNA). After the DNA ligase reaction and denaturing at an elevated temperature, the QCM frequency would revert to the original value for the target with single-base mismatch, whereas a reduced frequency response would be obtained for the case of the perfect match target. In this way, the purpose of point mutation discrimination could be achieved. The current approach is demonstrated with the identification of a single-base mutation in artificial codon CD17 of the beta-thalassemia gene, and the wild type and mutant type were discriminated successfully. The scanning electron microscope (SEM) image showing that plenty of gold nanoparticles remained on the electrode surface demonstrated that the nano-Au label served as an efficient signal amplification agent in QCM assay. A detection limit of 2.6 x 10(-9)mol/L of oligonucleotides was achieved. Owing to its ease of operation and low detection limit, it is expected that the proposed procedure may hold great promise in both research-based and clinical genomic assays.  相似文献   

15.
A factor limiting the detection time of biological particles using a quartz crystal microbalance (QCM) system is the kinetics of the particles arriving within the sensing region of the crystal surface. A device has been developed which, for the first time, combines ac electro-kinetic particle manipulation with simultaneous acoustic sensing on an electrode surface. We have termed this device a dielectrophoretic quartz crystal microbalance (DEP-QCM). Particles within the system are rapidly driven by electro-hydrodynamic and dielectrophoretic forces on to the crystal surface. Frequency shift analysis of mass-loaded DEP-QCM, induced by fluid motion, has shown significant improvements in rates of detection based on particle concentration, with steady-state responses established by a factor of five times faster than other quartz crystal microbalance surface loading techniques described in the literature. Comparisons of the static fluid case for QCM devices revealed that particles with a concentration of less than 10(8) nano-spheres/ml could not be detected within a 1h time period when allowed to sediment.  相似文献   

16.
A quartz crystal microbalance (QCM) cell biosensor utilizing living endothelial cells (ECs) or human breast cancer cells (MCF-7) adhering to the gold QCM surface was used to study the relative contributions of the cells and their underlying extracellular matrix (ECM) to the measured QCM Deltaf and DeltaR shifts. The ECM represents a natural biomaterial that is synthesized by the cells to enable their attachment to surfaces. We followed the detachment of the ECs or MCF-7 cells from their ECM using a nonproteolytic method and were able to apportion the total frequency, Deltaf, decrease of the biosensor into contributions from cell attachment and from the intact underlying ECM. We also demonstrated that the Deltaf shift remaining after EC removal corresponds to ECM as determined by light microscopic visualization of the stained protein. During the process of cell detachment, we observed a novel transient increase in viscoelastic behavior expressed as a transient increase in the motional resistance, DeltaR, parameter. Then we showed via a simulation experiment using ECs stained with fluorescent rhodamine-labeled phalloidin, an actin stain, that the transient viscoelastic increase correlated with cellular stress exhibited by the cells during removal with ethylene glycol bis(2-aminoethyl ether)-N,N,N',N'- tetraacetic acid. Prior to cells lifting from their ECM, the attached ECs rearrange their actin microfilaments first into peripheral stress fibers and second into internal aggregates, to maintain cell-cell connectivity, retain their spread morphology, and attempt to adhere more tightly to their underlying ECM. The decrease in DeltaR following its transient rise corresponds to cells finally losing their attachment focal points and lifting from the ECM. We also characterized the normalized f shifts, -Delta(Deltaf)(ECM)/attached cell and -Delta(Deltaf)(cells)/attached cell, as a function of varying the number of adherent cells. Finally, we demonstrate that the underlying native ECM biomaterial, from which all cells have been removed, does not exhibit any significant level of energy dissipation, in contrast to the cells when they are attached to the ECM.  相似文献   

17.
Electrical frequency dependent characterization of DNA hybridization   总被引:2,自引:0,他引:2  
The hybridization of oligomeric DNA was investigated using the frequency dependent techniques of electrochemical impedance spectroscopy (EIS) and quartz crystal microgravimetry (QCM). Synthetic 5'-amino terminated single stranded oligonucleotides (ssDNA) were attached to the exposed glass surface between the digits of microlithographically fabricated interdigitated microsensor electrodes using 3-glycidoxypropyl-trimethoxysilane. Similar ssDNA immobilization was achieved to the surface of the gold driving electrodes of AT-cut quartz QCM crystals using 3-mercaptopropyl-trimethoxysilane. Significant changes in electrochemical impedance values (both real and imaginary components) (11% increase in impedance modulus at 120 Hz) and resonant frequency values (0.004% decrease) were detected as a consequence of hybridization of the bound ssDNA upon exposure to its complement under hybridization conditions. Non-complementary (random) sequence sowed a modest decrease in impedance and a non-detectable change in resonant frequency. The possibility to detect the binding state of DNA in the vicinity of an electrode, without a direct connection between the measurement electrode and the DNA, has been demonstrated. The potential for development of label-free, low density DNA microarrays is demonstrated and is being pursued.  相似文献   

18.
In this work, we describe a method of constructing a film of linear poly(glycidyl methacrylate) (PGMA) polymer onto the surface of quartz crystal microbalance (QCM) electrode as a coating material that allows easy coupling of heparin molecules onto the electrode and facilitates the determination of the interaction between heparin and antithrombin III (AT III). The PGMA film was characterized with atomic force microscopy (AFM) and infra-red spectroscopy. The coupling of heparin was accomplished in one step solution reaction. A home-made quartz crystal microbalance-flow injection analysis (QCM-FIA) system with data analysis software developed in our laboratory was used to determine the interaction. The interactions between immobilized heparin and AT III were studied with various concentrations under various conditions. The obtained constants are kass=(1.49+/-0.12)x10(3)mol-1ls-1, kdiss=(3.94+/-0.63)x10(-2)s-1, KA=(3.82+/-0.33)x10(4)mol-1l.  相似文献   

19.
An immunosensing system based on a quartz crystal microbalance (QCM) is presented for the selection of both antigen specific recombinant antibodies and antigen specific human pancreatic secretory trypsin inhibitor (hPSTI) mutants isolated from large phage libraries. The QCM was integrated into a flow injection analysis system for the straightforward analysis of large sample numbers. Measurements were performed using a biotinylated antigen immobilized by streptavidin onto the gold surface of the quartz crystal and phages displaying recombinant antibodies or hPSTI mutants. The results obtained by the QCM were in accordance to those of a well established enzyme linked immunosorbent assay (ELISA). Therefore, the QCM is well suited for the detection of single high affinity clones isolated from large phage display libraries.  相似文献   

20.
By means of the quartz crystal microbalance (QCM), a convenient method was developed to determine the degree of orientation of purple membrane (PM) sheets on the air/water interface. Langmuir-Blodgett films from both wild-type and SH-mutant PM (bR D36C) were vertically deposited on the surface of gold-sputtered AT-cut quartz crystals. The shift of resonance frequency of the QCM during a special washing protocol allowed us to differentiate between physically adsorbed PM fragments and any PM attached to the gold surface via chemical bonds. By washing with organic solvents, complete desorption of the wild-type PM was achieved, whereas for the SH-mutant, approximately 60% of the PM fragments could not be detached from the surface. These PM sheets should be oriented with the cytoplasmic side facing the water subphase to that their SH-groups can chemically bind to the gold surface of the quartz plate.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号