首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
2.
Han X  Xu J  Chu Z  Dai D  Lu C  Wang X  Zhao L  Zhang C  Ji Y  Zhang H  Shang H 《PloS one》2011,6(12):e28792

Background

Recent studies have shown the public health importance of identifying acute HIV infection (AHI) in the men who have sex with men (MSM) of China, which has a much higher risk of HIV transmission. However, cost-utility analyses to guide policy around AHI screening are lacking.

Methodology/Principal Findings

An open prospective cohort was recruited among MSM living in Liaoning Province, Northeast China. Blood samples and epidemiological information were collected every 10 weeks. Third-generation ELISA and rapid test were used for HIV antibody screening, western blot assay (WB) served for assay validation. Antibody negative specimens were tested with 24 mini-pool nucleic acid amplification testing (NAAT). Specimens with positive ELISA but negative or indeterminate WB results were tested with NAAT individually without mixing. A cost-utility analysis of NAAT screening was assessed. Among the 5,344 follow-up visits of 1,765 MSM in 22 months, HIV antibody tests detected 114 HIV chronic infections, 24 seroconverters and 21 antibody indeterminate cases. 29 acute HIV infections were detected with NAAT from 21 antibody indeterminate and 1,606 antibody negative cases. The HIV-1 prevalence and incidence density were 6.6% (95% CI: 5.5–7.9) and 7.1 (95% CI: 5.4–9.2)/100 person-years, respectively. With pooled NAAT and individual NAAT strategy, the cost of an HIV transmission averted was $1,480. The addition of NAAT after HIV antibody tests had a cost-utility ratio of $3,366 per gained quality-adjusted life year (QALY). The input-output ratio of NAAT was about 1∶16.9.

Conclusions/Significance

The HIV infections among MSM continue to rise at alarming rates. Despite the rising cost, adding pooled NAAT to the HIV antibody screening significantly increases the identification of acute HIV infections in MSM. Early treatment and target-oriented publicity and education programs can be strengthened to decrease the risk of HIV transmission and to save medical resources in the long run.  相似文献   

3.

Background

A substantial proportion of HIV-infected individuals in the UK are unaware of their status and late presentations continue, especially in low prevalence areas. Fourth generation antigen/antibody rapid test kits could facilitate earlier diagnosis of HIV in non-clinical settings but lack data on performance under programmatic conditions.

Methods and Findings

We evaluated the performance of Determine HIV-1/2 Ag/Ab Combo Test (Determine Combo), a rapid test with indicators for both HIV antibodies and p24 antigen, in participants recruited from community outreach and hospital-based sexual health clinics. HIV infection was confirmed using laboratory enzyme-linked immunosorbent assay (EIA), Line Immuno Assay (LIA) and quantitative polymerase chain reaction (PCR). In total, 953 people underwent HIV testing. HIV antibody (Ab) prevalence was 1.8% (17/953). Four false positive rapid tests were identified: two antibody and two p24 antigen (Ag) reactions. Of participants diagnosed as HIV Ab positive, 2/17 (12%) were recent seroconverters based on clinical history and HIV antibody avidity test results. However, none of these were detected by the p24 antigen component of the rapid test kit. There were no other true positive p24 Ag tests.

Conclusion

These data lend support to an increasing body of evidence suggesting that 4th generation rapid HIV tests have little additional benefit over 3rd generation HIV kits for routine screening in low prevalence settings and have high rates of false positives. In order to optimally combine community-based case-finding among hard-to-reach groups with reliable and early diagnosis 3rd generation kits should be primarily used with laboratory testing of individuals thought to be at risk of acute HIV infection. A more reliable point of care diagnostic is required for the accurate detection of acute HIV infection under programmatic conditions.  相似文献   

4.
Recently updated recommendations for diagnosis of HIV infection suggest a new diagnostic algorithm including HIV-1/HIV-2 antibody differentiation immunoassay instead of western blot (WB) as a confirmatory testing. We evaluated Bio-Rad Geenius HIV1/2 confirmation assay as a simple and reliable alternative to WB in the Korean population with low HIV prevalence. The Geenius HIV1/2 was performed in a total of 192 serum specimens (140 reactive and 52 nonreactive specimens by ARCHITECT HIV Ag/Ab Combo assay) that were prospectively collected from five institutions. HIV-1 nucleic acid amplification test (NAT) was performed in negative or indeterminate specimens by Geenius HIV1/2 or WB. Among 140 reactive specimens by HIV Ag/Ab assay, 82 (58.6%) were positive for HIV-1 Ab by Geenius HIV1/2. Among 58 negative or indeterminate specimens by Geenius HIV1/2, four specimens (6.9%) were positive by HIV-1 NAT. The sensitivity and specificity of Geenius HIV1/2 were 95.3% and 100.0%, respectively. When we considered only WB, the sensitivity and specificity of Geenius HIV1/2 were 100.0% and 99.1%, respectively. Agreement between Geenius HIV1/2 and WB was excellent (weighted Kappa = 0.89). The Geenius HIV1/2 is simple and time-saving compared with WB. It has an excellent performance and can be a reliable alternative to WB. HIV-1 NAT should be performed in negative or indeterminate specimens by Geenius HIV1/2 to detect acute HIV infection as recommended in new HIV testing algorithms.  相似文献   

5.

Background

Detection of acute HIV infection (AHI) with pooled nucleic acid amplification testing (NAAT) following HIV testing is feasible. However, cost-effectiveness analyses to guide policy around AHI screening are lacking; particularly after more sensitive third-generation antibody screening and rapid testing.

Methods and Findings

We conducted a cost-effectiveness analysis of pooled NAAT screening that assessed the prevention benefits of identification and notification of persons with AHI and cases averted compared with repeat antibody testing at different intervals. Effectiveness data were derived from a Centers for Disease Control and Prevention AHI study conducted in three settings: municipal sexually transmitted disease (STD) clinics, a community clinic serving a population of men who have sex with men, and HIV counseling and testing sites. Our analysis included a micro-costing study of NAAT and a mathematical model of HIV transmission. Cost-effectiveness ratios are reported as costs per quality-adjusted life year (QALY) gained in US dollars from the societal perspective. Sensitivity analyses were conducted on key variables, including AHI positivity rates, antibody testing frequency, symptomatic detection of AHI, and costs. Pooled NAAT for AHI screening following annual antibody testing had cost-effectiveness ratios exceeding US$200,000 per QALY gained for the municipal STD clinics and HIV counseling and testing sites and was cost saving for the community clinic. Cost-effectiveness ratios increased substantially if the antibody testing interval decreased to every 6 months and decreased to cost-saving if the testing interval increased to every 5 years. NAAT was cost saving in the community clinic in all situations. Results were particularly sensitive to AHI screening yield.

Conclusions

Pooled NAAT screening for AHI following negative third-generation antibody or rapid tests is not cost-effective at recommended antibody testing intervals for high-risk persons except in very high-incidence settings. Please see later in the article for the Editors'' Summary  相似文献   

6.
7.
8.
A simple nucleic acid amplification test (NAAT) was developed for detection of Ureaplasma urealyticum infection based on the PCR amplification of the urease gene (UU1/UU2 Test). DNA was extracted from urogenital swabs and a 225-bp long DNA fragment was amplified by PCR. NAAT was compared to the commercial amplification kit for sexually transmitted disease reference assay. The sensitivity and specificity of the UU1/UU2 Test were determined to be 100 and 98.9%, respectively. The overall prevalence rate in this group of patients was found to be about 236 per 1000 (283 and 166 per 1000 in females and males, respectively). These data demonstrate that UU1/UU2 Test is suitable for effective epidemiological screening and/or diagnostic practice.  相似文献   

9.
10.
Long EF 《PloS one》2011,6(11):e27625

Background

At least 10% of the 56,000 annual new HIV infections in the United States are caused by individuals with acute HIV infection (AHI). It unknown whether the health benefits and costs of routine nucleic acid amplification testing (NAAT) are justified, given the availability of newer fourth-generation immunoassay tests.

Methods

Using a dynamic HIV transmission model instantiated with U.S. epidemiologic, demographic, and behavioral data, I estimated the number of acute infections identified, HIV infections prevented, quality-adjusted life years (QALYs) gained, and the cost-effectiveness of alternative screening strategies. I varied the target population (everyone aged 15-64, injection drug users [IDUs] and men who have sex with men [MSM], or MSM only), screening frequency (annually, or every six months), and test(s) utilized (fourth-generation immunoassay only, or immunoassay followed by pooled NAAT).

Results

Annual immunoassay testing of MSM reduces incidence by 9.5% and costs <$10,000 per QALY gained. Adding pooled NAAT identifies 410 AHI per year, prevents 9.6% of new cases, costs $92,000 per QALY gained, and remains <$100,000 per QALY gained in settings where undiagnosed HIV prevalence exceeds 4%. Screening IDUs and MSM annually with fourth-generation immunoassay reduces incidence by 13% with cost-effectiveness <$10,000 per QALY gained. Increasing the screening frequency to every six months reduces incidence by 11% (MSM only) or 16% (MSM and IDUs) and costs <$20,000 per QALY gained.

Conclusions

Pooled NAAT testing every 12 months of MSM and IDUs in the United States prevents a modest number of infections, but may be cost-effective given sufficiently high HIV prevalence levels. However, testing via fourth-generation immunoassay every six months prevents a greater number of infections, is more economically efficient, and may obviate the benefits of acute HIV screening via NAAT.  相似文献   

11.
建立一种便捷、灵敏的检测方法,即逆转录环介导等温核酸扩增技术(RT-LAMP)用于H5N1亚型禽流感病毒基因检测.该技术使用特异对应于靶序列中8个基因区段的6条特异引物,在等温条件下进行核酸扩增反应.对51份实验感染动物及病毒培养标本的H5N1亚型禽流感病毒的HA、NA基因区进行了RT-LAMP检测,并以SYBR Green Ⅰ为反应指示剂进行了逆转录环介导等温核酸扩增技术,对该反应进行实时监控,经对扩增产物做内切酶验证和测序分析,证明RT-LAMP技术的特异性;同时,用10倍系列稀释的RNA样品对该检测方法的灵敏度进行了测试.结果显示:利用RT-LAMP技术成功检测到H5N1禽流感病毒的HA、NA基因区,且RT-LAMP与Real-time PCR结果呈现很好的一致性.此方法的灵敏度可达到能检测10个拷贝RNA分子水平.因此,RT-LAMP技术应用于H5N1亚型禽流感病毒的快速检测是一种可行的方法.  相似文献   

12.
小鼠肝炎病毒逆转录环介导等温扩增检测技术的建立   总被引:1,自引:0,他引:1  
袁文  刘忠华  张钰  刘香梅  黄韧 《中国实验动物学报》2009,17(5):354-359,I0007,I0008
  相似文献   

13.
The present report describes an alternative method for in vitro detection of HIV-1-specific antibody secretion in 24h of culture employing as stimulant of peripheral blood mononuclear cells the disrupted inactivated whole virus adsorbed onto microwells in a commercial ELISA kit plates. The results obtained from this technique have showed high sensitivity and specificity since it was capable of detecting HIV-1 infection early after birth. There were neither false-positivity nor false-negativity when blood samples obtained from HIV-1 seronegative asymptomatic individuals, and HIV-1 seropositive adult patients were analyzed. This rapid, low cost, simple, highly sensitive and specific assay can be extremely useful for early diagnosis of pediatric HIV infection.  相似文献   

14.
15.
Sensitive diagnostic tests for infectious diseases often employ nucleic acid amplification technologies (NAATs). However, most NAAT assays, including many isothermal amplification methods, require power-dependent instrumentation for incubation. For use in low resource settings (LRS), diagnostics that do not require consistent electricity supply would be ideal. Recombinase polymerase amplification (RPA) is an isothermal amplification technology that has been shown to typically work at temperatures ranging from 25–43°C, and does not require a stringent incubation temperature for optimal performance. Here we evaluate the ability to incubate an HIV-1 RPA assay, intended for use as an infant HIV diagnostic in LRS, at ambient temperatures or with a simple non-instrumented heat source. To determine the range of expected ambient temperatures in settings where an HIV-1 infant diagnostic would be of most use, a dataset of the seasonal range of daily temperatures in sub Saharan Africa was analyzed and revealed ambient temperatures as low as 10°C and rarely above 43°C. All 24 of 24 (100%) HIV-1 RPA reactions amplified when incubated for 20 minutes between 31°C and 43°C. The amplification from the HIV-1 RPA assay under investigation at temperatures was less consistent below 30°C. Thus, we developed a chemical heater to incubate HIV-1 RPA assays when ambient temperatures are between 10°C and 30°C. All 12/12 (100%) reactions amplified with chemical heat incubation from ambient temperatures of 15°C, 20°C, 25°C and 30°C. We also observed that incubation at 30 minutes improved assay performance at lower temperatures where detection was sporadic using 20 minutes incubation. We have demonstrated that incubation of the RPA HIV-1 assay via ambient temperatures or using chemical heaters yields similar results to using electrically powered devices. We propose that this RPA HIV-1 assay may not need dedicated equipment to be a highly sensitive tool to diagnose infant HIV-1 in LRS.  相似文献   

16.
17.
HIV-1 transmission and viral evolution in the first year of infection were studied in 11 individuals representing four transmitter-recipient pairs and three independent seroconverters. Nine of these individuals were enrolled during acute infection; all were men who have sex with men (MSM) infected with HIV-1 subtype B. A total of 475 nearly full-length HIV-1 genome sequences were generated, representing on average 10 genomes per specimen at 2 to 12 visits over the first year of infection. Single founding variants with nearly homogeneous viral populations were detected in eight of the nine individuals who were enrolled during acute HIV-1 infection. Restriction to a single founder variant was not due to a lack of diversity in the transmitter as homogeneous populations were found in recipients from transmitters with chronic infection. Mutational patterns indicative of rapid viral population growth dominated during the first 5 weeks of infection and included a slight contraction of viral genetic diversity over the first 20 to 40 days. Subsequently, selection dominated, most markedly in env and nef. Mutants were detected in the first week and became consensus as early as day 21 after the onset of symptoms of primary HIV infection. We found multiple indications of cytotoxic T lymphocyte (CTL) escape mutations while reversions appeared limited. Putative escape mutations were often rapidly replaced with mutually exclusive mutations nearby, indicating the existence of a maturational escape process, possibly in adaptation to viral fitness constraints or to immune responses against new variants. We showed that establishment of HIV-1 infection is likely due to a biological mechanism that restricts transmission rather than to early adaptive evolution during acute infection. Furthermore, the diversity of HIV strains coupled with complex and individual-specific patterns of CTL escape did not reveal shared sequence characteristics of acute infection that could be harnessed for vaccine design.  相似文献   

18.
19.
20.
该文介绍了一种便捷、灵敏而又特异的环介导逆转录等温扩增基因检测技术,该技术分别使用特异对应于靶序列中8个基因区段的3对特殊引物,并在反转录酶和Bst-DNA聚合酶的作用下对靶序列进行等温核酸扩增反应,整个检测反应只需1~2h。利用这种技术成功检测了丙型肝炎病毒基因,对60份经Real-time PCR或RT-PCR验证阳性的血清样品检测,阳性符合率为98%。同时,对扩增终产物进一步进行酶切分析,并与HIV、HBV和不同亚型流感病毒RNA进行交叉反应和特异性测试,均与预期结果吻合。将Real-time PCR定量后的RNA系列稀释后对检测方法的灵敏度进行了测试。结果显示,该技术的检测灵敏度在理论上可达到10个拷贝的RNA分子。以上结果证明,RT-LAMP扩增技术是一种检测程序简单、灵敏度和特异性较高的基因检测手段,在丙型肝炎病毒的快速检测方面具有一定的开发潜力。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号