1.

Objective

Reconduction across an ablation line is a common reason for arrhythmia recurrence over time. The hybrid procedure combines epicardial ablation of the pulmonary vein (PV) and creation of a box lesion with endocardial touch-ups for any electrical gaps. A high contact force (CF) between the ablation tip and cardiac tissue may increase the risk of thrombus formation, catheter tip charring, steam pop formation, and even cardiac perforation. CF monitoring is a significant new parameter for titration of the CF for creating an adequate lesion.

Methods

Thirty-eight consecutive patients underwent epicardial ablation using bipolar radiofrequency devices. After checking electrical bidirectional block of the ablation lines, an endocardial CF catheter was used for further ablation (if needed) to complete the isolation of PVs, box lesion, cavotricuspid isthmus (CTI), and complex fractionated atrial electrograms (CFAE).

Results

Endocardial touch-up was needed for 2 PVs (1.3 %) and 10 (26.3 %) box lesions. It was also used for the CTI line in 7 (18.4 %) patients, atrial tachycardia in 3 (7.9 %) patients, and additional CFAE ablation in 17 (44.7 %) patients. All 5 patients with arrhythmia recurrence had a mean CF < 10 g (p = 0.03). Procedure duration was significantly shorter in the CF group (223 ± 57 vs. 256 ± 60 min, p = 0.03) compared with control group.

Conclusion

Use of CF catheters is safe, feasible, and complementary to a hybrid procedure setup for atrial fibrillation ablation. Its real-time monitoring may predict future arrhythmia recurrence, and decrease procedure time.  相似文献   

2.

Introduction

Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an ablation catheter with enhanced tip irrigation.

Methods

A total of 59 patients were included in the analysis. In 30 patients circumferential PVI was performed using the Thermocool Smarttouch® ablation catheter (ST) whereas in 29 patients circumferential PVI using the Thermocool Surround Flow SF® ablation catheter (SF) was performed. Patients were compared in regard to procedure time, fluoroscopy time/dose as well as RF-application duration and completeness of PVI. Adverse events (pericardial effusion, PV stenosis, stroke, death) were evaluated. The presence of sinus rhythm off antiarrhythmic medication was assessed during 6 months follow-up using multiple 7 day Holter-ECGs.

Results

In both groups, all PVs were isolated without serious adverse events. Procedure time was 2.15 ± 0.5 h (ST) vs. 2.37 ± 1.13 h (SF) (p = 0.19). Duration of RF-applications was 46.6 ± 18 min (ST) and 49.8 ± 19 min (SF) (p = 0.52). Fluoroscopy time was 25.2 ± 13 min (ST) vs. 29 ± 18 min (SF), fluoroscopy dose 2675.6 ± 1658 versus 3038.3 ± 1997 cGym2 (p = 0.36 and 0.46 respectively). Sinus rhythm off antiarrhythmic medication validated with 7 day Holter ECGs was present in both groups in 72% of patients after 6 months of follow up.

Conclusion

PVI using the new contact force catheter is safe and effective in patients with paroxysmal AF.  相似文献   

3.

Aims

To evaluate the effects of pulmonary vein isolation (PVI) in terms of feasibility, safety and success rate on a midterm follow-up period in septuagenarians undergoing ablation with the Arctic Front Cryoballoon for atrial fibrillation (AF).

Methods and Results

We prospectively enrolled 21 patients aged 70 years or older (14 male; age 73 ± 2.5 years) elected to circumferential PVI with the 28mm cryoballoon for symptomatic drug resistant paroxysmal AF. A total number of 82 pulmonary veins (PV) were evidenced. Successful isolation could be obtained in all 82 (100%) PV ostia at the end of procedure. No major complication occurred during procedure. At a mean follow-up of 11.5 ± 4.7 months following ablation, 62% of patients did not present recurrence of atrial arrhythmias.

Conclusion

Cryoballoon ablation may be feasible and safe in older patients. Moreover a large proportion of the latter did not present AF recurrence during follow-up.  相似文献   

4.

Aims

This study investigated the possible association between hs-CRP as well as hs-CRP changes and rhythm outcome after AF catheter ablation.

Methods

We studied 68 consecutive patients with AF undergoing catheter ablation. hs-CRP levels were measured using commercially available assays before and 6 months after catheter ablation. Serial 7-day Holter ECGs were used to detect AF recurrences.

Results

Early AF recurrence (ERAF, within one week) was observed in 38%, while late AF recurrence (LRAF, between 3 and 6 months) occurred in 18% of the patients. None of the baseline clinical or echocardiographic variables was predictive of ERAF or LRAF. Baseline hs-CRP measured 2.07±1.1 µg/ml and was not associated with ERAF and LRAF. At 6 months, hs-CRP levels were comparable with baseline values (2.14±1.19 µg/ml, p = 0.409) and were also not related with LRAF. However, patients with LRAF showed an hs-CRP increase from 2.03±0.61 to 2.62±1.52 µg/ml (p = 0.028). Patients with an hs-CRP change in the upper tertile (>0.2 µg/ml) had LRAF in 32% as opposed to 11% (p = 0.042) in patients in the lower (<−0.3 µg/ml) or intermediate (−0.3–0.2 µg/ml) tertile.

Conclusions

Changes in hs-CRP but not baseline hs-CRP are associated with rhythm outcome after AF catheter ablation. This finding points to a link between an inflammatory response and AF recurrence in this setting.  相似文献   

5.

Background

Galectin-3 (Gal-3) is an emerging biomarker in heart failure that is involved in fibrosis and inflammation. However, its potential value as a prognostic marker in atrial fibrillation (AF) is unknown. The aim of this study was to assess the impact of AF catheter ablation on Gal-3 and evaluate its prognostic impact for predicting rhythm outcome after catheter ablation.

Methods

Gal-3 was measured at baseline and after 6 months using specific ELISA. AF recurrences were defined as any atrial arrhythmia lasting longer than 30 sec within 6 months after ablation.

Results

In 105 AF patients (65% males, age 62±9 years, 52% paroxysmal AF) undergoing catheter ablation, Gal-3 was measured at baseline and after 6 months and compared with an AF-free control cohort (n=14, 50 % males, age 58±11 years). Gal-3 was higher in AF patients compared with AF-free controls (7.8±2.9 vs. 5.8±1.8, ng/mL, p=0.013). However, on multivariable analysis, BMI (p=0.007) but not AF (p=0.068) was associated with Gal-3. In the AF cohort, on univariable analysis higher Gal-3 levels were associated with female gender (p=0.028), higher BMI (p=0.005) and both CHADS2 (p=0.008) and CHA2DS2-VASC (p=0.016) scores, however, on multivariable analysis only BMI remained significantly associated with baseline Gal-3 (p=0.016). Gal-3 was similar 6 months after AF catheter ablation and was not associated with sinus rhythm maintenance.

Conclusions

Although galectin-3 levels are higher in AF patients, this is driven by cardiometabolic co-morbidities and not heart rhythm. Gal-3 is not useful for predicting rhythm outcome of catheter ablation.  相似文献   

6.

Background

Left atrial (LA) enlargement is a predictor of worse outcome after catheter ablation for atrial fibrillation (AF). Widely used two-dimensional (2D)-echocardiography is inaccurate and underestimates real LA volume (LAV). We hypothesized that baseline clinical characteristics of patients can be used to adjust 2D-ECHO indices of LAV in order to minimize this disagreement.

Methods

The study enrolled 535 patients (59 ± 9 years; 67% males; 43% paroxysmal AF) who underwent catheter ablation for AF in three specialized centers. We investigated multivariately the relationship between 2D-echocardiographic indices of LA size, specifically LA diameter in M-mode in the parasternal long-axis view (LAD), LAV assessed by the prolate-ellipsoid method (LAVEllipsoid), LAV by the planimetric method (LAVPlanimetry), and LAV derived from 3D-electroanatomic mapping (LAVCARTO).

Results

Cubed LAD of 106 ± 45 ml, LAVEllipsoid of 72 ± 24 ml and LAVPlanimetry of 88 ± 30 ml correlated only modestly (r = 0.60, 0.69, and 0.53, respectively) with LAVCARTO of 137 ± 46 ml, which was significantly underestimated with a bias (±1.96 standard deviation) of -31 (-111; +49) ml, -64 (-132; +2) ml, and -49 (-125; +27) ml, respectively; p < 0.0001 for their mutual difference. LA enlargement itself, age, gender, type of AF, and the presence of structural heart disease were independent confounders of measurement error of 2D-echocardiographic LAV.

Conclusion

Accuracy and precision of all 2D-echocardiographic LAV indices are poor. Their agreement with true LAV can be significantly improved by multivariate adjustment to clinical characteristics of patients.  相似文献   

7.

Background

Ganglionated plexi (GP) ablation has been become an adjunct to pulmonary vein isolation (PVI). This study describes the long-term results of minimally invasive surgical PVI, ablation of GPs, and exclusion of the left atrial appendage for atrial fibrillation (AF).

Methods

Long-term follow-up of 55 months was performed in 139 consecutive patients (age 58.3±20.8 years) with symptomatic, drug-refractory lone AF who underwent minimally invasive surgical PVI, GPs ablation, and exclusion of the left atrial appendage. Success was defined as freedom from AF, atrial flutter, or atrial tachycardia off antiarrhythmic drugs.

Results

AF was paroxysmal in 77.7%, persistent in 12.2% and long-standing persistent in 10.1%. Single-procedure success rate was 71.7%, 59.4% and 46.6% at 12, 24 and 60 months respectively. Single-procedure success rate was 72.9%, 62.6% and 51.8% for paroxysmal AF, 64.7%, 35.3%, and 28.2% for persistent AF, 71.4%, 64.3% and 28.6% for long-standing persistent AF at 12, 24 and 60 months respectively. Duration of AF>24 months (hazard ratio [HR]: 3.09, 95% confidence interval [CI]: 1.51 to 6.32; p = 0.002), left atrial diameter≥40 mm (HR: 4.03, 95% CI: 1.88 to 8.65; p<0.001), early recurrence of AF (HR: 4.66, 95% CI: 2.25 to 9.63; p<0.001) independently predicted long-term recurrence of AF. There was no procedure-related death. One patient converted to median sternotomy because of uncontrolled bleeding. Two patients underwent perioperative cerebrovascular events.

Conclusions

At nearly 5-year of clinical follow-up, single-procedure success rate of minimally invasive surgical PVI with GP ablation was 51.8% for paroxysmal AF, 28.2% for persistent AF, 28.6% for long-standing persistent AF after initial procedure. Patients with AF duration≤24 months, left atrial diameter<40 mm and no early recurrence of AF, had favorable outcomes.  相似文献   

8.

Background

Adenosine infusion after pulmonary vein isolation (PVI) with radiofrequency energy reveals dormant muscular sleeves and predicts atrial fibrillation (AF) recurrence. The aim of our study was to determine whether adenosine could reveal dormant PV sleeves after cryoballoon isolation and study its effect on long-term recurrence of AF.

Methods

Patients with paroxysmal AF underwent cryoballoon PVI. After PVI, adenosine 25 mg was infused to test for dormant muscular sleeves in each vein. If reconnection under adenosine was shown, further cryoballoon ablation was performed until no more reconnection occurred. Follow-up was performed with ECG, 24-h Holter recording, and a symptom questionnaire at three monthly intervals. Transtelephonic Holter monitoring was performed for 1 month before and 3 months after PVI. Patients who underwent cryoballoon PVI without adenosine administration were used as controls for comparison.

Results

In the study group (n = 34, 24 males), adenosine revealed dormant sleeves in 9/132 (8 %) veins, and 7/34 (21 %) patients. All but one vein was further treated until the dormant sleeves were isolated. During a mean follow-up of 520 ± 147 days, 23/34 (68 %) patients were free of AF without antiarrhythmic drugs (AADs). In the control group (n = 65, 46 males), 29/65 (46 %) were free of AF without AADs. There were significantly less AF recurrences in the study group (p = 0.04).

Conclusions

Adenosine administration after cryoballoon PVI reveals dormant muscular sleeves in 21 % of patients. Clinical follow-up shows that adenosine testing is effective in reducing AF recurrence after cryoballoon ablation.  相似文献   

9.

Objective

The aim of this study was to quantify the effects of right ventricular apical pacing (RVAP) on hemodynamics in left anterior descending coronary artery (LAD) and anterior interventricular vein (AIV) contrast to baseline condition in open chest beagles using Doppler ultrasound imaging.

Methods

In 6 anesthetized open chest beagles, the spectral Doppler waveforms of the middle segmental LAD and the AIV were acquired with a 5 MHz linear array transducer at baseline condition and during RVAP. The aortic pressure-time curves were recorded synchronously. The Doppler hemodynamic parameters of the LAD and AIV at both states were derived and compared.

Results

The spectral Doppler waveforms of the LAD had a principal diastolic positive wave (Dp), which heelled by a momentary negative wave and a positive wave during early systole at baseline condition. During RVAP, an additional negative wave appeared in the LAD at late systole. The duration of the Dp shortened (227.83±12.16 ms vs 188.50±8.97 ms, P<0.001), and the acceleration of the Dp decreased (11.85±2.22 m/s2 vs 3.54±0.42 m/s2, P<0.001). The spectral Doppler waveforms of the AIV only had a principal positive wave (Sp) at baseline condition, but an additional diastolic negative wave appeared during RVAP. The duration of the Sp shortened (242.99±7.98 ms vs 215.38±15.44 ms, P<0.001), and the acceleration of the Sp decreased (9.61±1.93 m/s2 vs 1.01±0.11 m/s2, P<0.001).

Conclusions

Obvious hemodynamic changes in the LAD and AIV during RVAP were observed, and these abnormal flow patterns in epicardial coronary arteries and vena coronaria may be sensitive and important hints of the disturbed cardiac electrical and mechanical activity sequences.  相似文献   

10.

Background

Combination of riboflavin/UVA cross-linking (CXL) and excimer laser ablation is a promising therapy for treating corneal ectasia. The cornea is strengthened by cross-linking, while the irregular astigmatism is reduced by laser ablation. This study aims to compare the efficacy of excimer laser ablation on porcine corneas with and without cross-linking.

Methods and Findings

The porcine cornea was de-epithelialized and treated with 0.1% riboflavin solution for 30 minutes. A half of the cornea was exposed to UVA-radiation for another 30 minutes while the controlled half of the cornea was protected from the UVA using a metal shield. Photo therapeutic keratectomy (PTK) was then performed on the central cornea. Corneal thickness of 5 paired locations on the horizontal line, ±0.5, ±1.0, ±1.5, ±2.0, and ±2.5 mm from the central spot, were measured using optical coherence tomography prior to and after PTK. The ablation depth was then determined by the corneal thickness. There was a 9% difference (P<0.001) in the overall ablation depth between the CXL-half corneas (158±22 µm) and the control-half corneas (174±26 µm). The ablation depths of all 5 correspondent locations on the CXL-half were significantly smaller (P<0.001).

Conclusion

The efficacy of the laser ablation seems to be lower in cross-linked cornea. Current ablation algorithms may need to be modified for cross-linked corneas.  相似文献   

11.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

12.

Background

Catheter ablation (CA) of atrial fibrillation (AF) is associated with inflammatory response, endothelial damage and with increased risk of thrombosis. However, whether these processes differ in peripheral and cardiac circulation is unknown.

Methods

Plasma markers (von Willebrand factor (vWf), soluble P-selectin (sPsel) and interleukin-6 (IL-6)) were measured by ELISA at three time points in 80 patients (62±10 years, 63% males, 41% paroxysmal AF) undergoing CA. These were at baseline – from femoral vein (FV) and left atrium (LA) before ablation; directly after ablation – from the pulmonary vein (PV), LA and FV; and 24 hours after procedure – from a cubital vein (CV).

Results

The levels of vWF and IL6 – but not sP-sel – increased significantly 24h after procedure (p<0.001). Baseline vWF was significantly associated with persistent AF (Beta = .303, p = 0.006 and Beta = .300, p = 0.006 for peripheral and cardiac levels, respectively), while persistent AF (Beta = .250, p = 0.031) and LAA flow pattern (Beta = .386, p<0.001) remained associated with vWF in cardiac blood after ablation. Advanced age was significantly associated with IL6 levels at baseline and after ablation in peripheral and cardiac blood. There were no clinical, procedural or anti-coagulation characteristics associated with sP-sel levels in cardiac blood, while peripheral sP-sel levels were associated with hypertension before (Beta = −.307, p = 0.007) and with persistent AF after ablation (Beta = −.262, p = 0.020).

Conclusions

vWF levels are higher in persistent AF and are associated with LAA rheological pattern after AF ablation. Increase of peripheral vWF and IL6 levels after procedure supports current AF ablation management with careful control of post-procedural anticoagulation to avoid ablation-related thromboembolism.  相似文献   

13.

Aims

Cardiovascular magnetic resonance (MR) provides non-invasive assessment of early (24-hour) edema and injury following pulmonary vein isolation (by ablation) and subsequent scar formation. We hypothesize that 24-hours after ablation, cardiovascular MR would demonstrate a pattern of edema and injury due to ablation and the severity would correlate with subsequent scar.

Methods

Fifteen atrial fibrillation patients underwent cardiovascular MR prior to pulmonary vein isolation, 24-hours post (N = 11) and 30-days post (N = 7) ablation, with T2-weighted (T2W) and late gadolinium enhancement (LGE) imaging. Left atrial wall thickness, edema enhancement ratio and LGE enhancement were assessed at each time point. Volumes of LGE and edema enhancement were measured, and the circumferential presence of injury was assessed at 24-hours, including comparison with LGE enhancement at 30 days.

Results

Left atrial wall thickness was increased 24-hours post-ablation (10.7±4.1 mm vs. 7.0±1.8 mm pre-PVI, p<0.05). T2W enhancement at 24-hours showed increased edema enhancement ratio (1.5±0.4 for post-ablation, vs. 0.9±0.2 pre-ablation, p<0.001). Edema and LGE volumes at 24-hours were correlated with 30-day LGE volume (R = 0.76, p = 0.04, and R = 0.74, p = 0.09, respectively). Using a 16 segment model for assessment, 24-hour T2W had sensitivity, specificity, and accuracy of 82%, 63%, and 79% respectively, for predicting 30-day LGE. 24-hour LGE had sensitivity, specificity, and accuracy of 91%, 47%, and 84%.

Conclusions

Increased left atrial wall thickening and edema were characterized on cardiovascular MR early post-ablation, and found to correlate with 30-day LGE scar.  相似文献   

14.
15.

Introduction

Pulmonary vein (PV) reconnection is frequently the cause of recurrence of atrial fibrillation (AF) after ablation. The second-generation gold multi-electrode ablation (Gold-MEA) catheter has a new design possibly resulting in improved lesion formation compared with its predecessor. We aimed to determine the association between effective radiofrequency applications with the Gold-MEA catheter and outcome after AF ablation.

Methods

50 consecutive patients with paroxysmal AF underwent Gold-MEA (PVAC GOLDTM, Medtronic Inc.) ablation. The Gold-MEA catheter was navigated to the PV ostium by fluoroscopy. Duty-cycled radiofrequency ablations were performed at all PV ostia. Lesions were considered transmural when electrode temperature was >50 °C and power >3 W for >30 seconds. After the ablation procedure, patients visited the outpatient clinic at 3?month intervals including 24-hour Holter ECGs.

Results

Mean age was 56 years. All PVs were acutely isolated with the Gold-MEA catheter. Procedure time was 111 ± 22 minutes, ablation time was 24 ± 6.7 minutes and fluoroscopy time was 20 ± 8.1 minutes. No procedure-related complications were observed. One year after ablation, 60?% of patients were still free of arrhythmia recurrences after a single PV isolation attempt. The number of transmural lesions was associated with arrhythmia-free survival: 25.0?% in <72 transmural lesions, 64.3?% in 72–108 transmural lesions and 71.4?% in >108 transmural lesions (p = 0.029).

Conclusion

PV isolation can be performed successfully with the Gold-MEA catheter, with a favourable safety profile. Transmurality of lesions was associated with ablation success and may improve AF ablation success.
  相似文献   

16.

Background

Ablation of cardiac tissue is an essential tool for the treatment of arrhythmias, particularly of atrial fibrillation, atrial flutter, and ventricular tachycardia. Current ablation technologies suffer from substantial recurrence rates, thermal side effects, and long procedure times. We demonstrate that ablation with nanosecond pulsed electric fields (nsPEFs) can potentially overcome these limitations.

Methods

We used optical mapping to monitor electrical activity in Langendorff-perfused New Zealand rabbit hearts (n = 12). We repeatedly inserted two shock electrodes, spaced 2–4 mm apart, into the ventricles (through the entire wall) and applied nanosecond pulsed electric fields (nsPEF) (5–20 kV/cm, 350 ns duration, at varying pulse numbers and frequencies) to create linear lesions of 12–18 mm length. Hearts were stained either with tetrazolium chloride (TTC) or propidium iodide (PI) to determine the extent of ablation. Some stained lesions were sectioned to obtain the three-dimensional geometry of the ablated volume.

Results

In all animals (12/12), we were able to create nonconducting lesions with less than 2 seconds of nsPEF application per site and minimal heating (< 0.2°C) of the tissue. The geometry of the ablated volume was smoother and more uniform throughout the wall than typical for RF ablation. The width of the lesions could be controlled up to 6 mm via the electrode spacing and the shock parameters.

Conclusions

Ablation with nsPEFs is a promising alternative to radiofrequency (RF) ablation of AF. It may dramatically reduce procedure times and produce more consistent lesion thickness than RF ablation.  相似文献   

17.

Rationale

There is growing evidence that obstructive sleep apnea is associated with coronary artery disease. However, there are no data on the course of coronary stenosis after percutaneous coronary intervention in patients with obstructive sleep apnea.

Objectives

To determine whether sleep apnea is associated with increased late lumen loss and restenosis after percutaneous coronary intervention.

Methods

78 patients with coronary artery disease who underwent elective percutaneous coronary intervention were divided in 2 groups: 43 patients with an apnea hypopnea – Index < 10/h (group I) and 35 pt. with obstructive sleep apnea and an AHI > 10/h (group II). Late lumen loss, a marker of restenosis, was determined using quantitative coronary angiography after 6.9 ± 3.1 months.

Main results

Angiographic restenosis (>50% luminal diameter), was present in 6 (14%) of group I and in 9 (25%) of group II (p = 0.11). Late lumen loss was significant higher in pt. with an AHI > 10/h (0.7 ± 0.69 mm vs. 0.38 ± 0.37 mm, p = 0.01). Among these 35 patients, 21(60%) used their CPAP devices regularly. There was a marginally lower late lumen loss in treated patients, nevertheless, this difference did not reach statistical significance (0.57 ± 0.47 mm vs. 0.99 ± 0.86 mm, p = 0.08). There was no difference in late lumen loss between treated patients and the group I (p = 0.206).

Conclusion

In summary, patients with OSA and coronary artery disease have a higher degree of late lumen loss, which is a marker of restenosis and vessel remodeling after elective percutaneous intervention.  相似文献   

18.

Introduction

Radiofrequency(RF) ablation has become the first line of therapy for atrial flutter(AFL). Advances in catheter and mapping technologies have led to better understanding and different approaches for treating this arrhythmia. We describe the results of different approaches to ablate this arrhythmia.

Materials and Methods

A cohort of 198 patients with isthmus dependent AFL. The techniques used were: 10mm-tip catheter with power set to 100w, 8mm-tip catheter with power set to 60W and irrigated tip catheter.

Results

212 procedures, including redos were done in 198 consecutive patients. We used irrigated tip catheters in 14 procedures, 8mm-tip in 55 procedures, and 10mm-tip in 143 procedures. Bidirectional block was achieved in 97.6% of cases with all techniques, with no difference among them. Procedure time was shorter in the 10mm-tip versus 8mm-tip(69.6±30.6min vs.105±43min) or irrigated tip(180±90min) (P<0.05). Fluoroscopy time was also shorter in the 10mm-tip versus 8mm-tip (24±18min vs. 37±23min) or irrigated tip (110±25min)(P<0.05). The cumulative incidence of failure during follow-up was 1.2%/year in the 10mm, 10.1%year in the 8mm and 6.9%year in the irrigated tip. The survival free of a new procedure was significantly higher among 10mm patients.

Conclusions

In our series we found a high rate of acute success with the use of different techniques for AFL ablation. Procedure and fluoroscopic times were shorter with the use of 10mm-tip as compared with the others techniques. The long-term risk of recurrence was lower when we used the 10mm-tip catheter and the survival free of a second procedure was higher among patients treated with this catheter.  相似文献   

19.

Background

To date, no experimental or clinical study provides detailed analysis of vascular impedance changes after total aortic arch replacement. This study investigated ventriculoarterial coupling and vascular impedance after replacement of the aortic arch with conventional prostheses vs. decellularized allografts.

Methods

After preparing decellularized aortic arch allografts, their mechanical, histological and biochemical properties were evaluated and compared to native aortic arches and conventional prostheses in vitro. In open-chest dogs, total aortic arch replacement was performed with conventional prostheses and compared to decellularized allografts (n = 5/group). Aortic flow and pressure were recorded continuously, left ventricular pressure-volume relations were measured by using a pressure-conductance catheter. From the hemodynamic variables end-systolic elastance (Ees), arterial elastance (Ea) and ventriculoarterial coupling were calculated. Characteristic impedance (Z) was assessed by Fourier analysis.

Results

While Ees did not differ between the groups and over time (4.1±1.19 vs. 4.58±1.39 mmHg/mL and 3.21±0.97 vs. 3.96±1.16 mmHg/mL), Ea showed a higher increase in the prosthesis group (4.01±0.67 vs. 6.18±0.20 mmHg/mL, P<0.05) in comparison to decellularized allografts (5.03±0.35 vs. 5.99±1.09 mmHg/mL). This led to impaired ventriculoarterial coupling in the prosthesis group, while it remained unchanged in the allograft group (62.5±50.9 vs. 3.9±23.4%). Z showed a strong increasing tendency in the prosthesis group and it was markedly higher after replacement when compared to decellularized allografts (44.6±8.3dyn·sec·cm−5 vs. 32.4±2.0dyn·sec·cm−5, P<0.05).

Conclusions

Total aortic arch replacement leads to contractility-afterload mismatch by means of increased impedance and invert ventriculoarterial coupling ratio after implantation of conventional prostheses. Implantation of decellularized allografts preserves vascular impedance thereby improving ventriculoarterial mechanoenergetics after aortic arch replacement.  相似文献   

20.

Purpose

The aim was to assess atrial fibrillation (AF) and vulnerability in Wolff-Parkinson-White (WPW) syndrome patients using two-dimensional speckle tracking echocardiography (2D-STE).

Methods

All patients were examined via transthoracic echocardiography and 2D-STE in order to assess atrial function 7 days before and 10 days after RF catheter ablation. A postoperative 3-month follow-up was performed via outpatient visit or telephone calls.

Results

Results showed significant differences in both body mass index (BMI) and supraventricular tachycardia (SVT) duration between WPW patients and DAVNP patients (both P<0.05). Echocardiography revealed that the maximum left atrial volume (LAVmax) and the left ventricular mass index (LVMI) in diastole increased noticeably in patients with WPW compared to patients with DAVNP both before and after ablation (all P<0.05). Before ablation, there were obvious differences in the levels of SRs, SRe, and SRa from the 4-chamber view (LA) in the WPW patients group compared with patients in the DAVNP group (all P<0.05). In the AF group, there were significant differences in the levels of systolic strain rate (SRs), early diastolic strain rate (SRe), and late diastolic strain rate (SRa) from the 4-chamber view (LA) both before and after ablation (all P<0.05). In the non-AF group, there were decreased SRe levels from the 4-chamber view (LA/RA) pre-ablation compared to post-ablation (all P<0.05).

Conclusion

Our findings provide convincing evidence that WPW syndrome may result in increased atrial vulnerability and contribute to the development of AF. Further, RF catheter ablation of AAV pathway can potentially improve atrial function in WPW syndrome patients. Two-dimensional speckle tracking echocardiography imaging in WPW patients would be necessary in the evaluation and improvement of the overall function of RF catheter ablation in a long-term follow-up period.  相似文献   