首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.

Background

Adenosine infusion after pulmonary vein isolation (PVI) with radiofrequency energy reveals dormant muscular sleeves and predicts atrial fibrillation (AF) recurrence. The aim of our study was to determine whether adenosine could reveal dormant PV sleeves after cryoballoon isolation and study its effect on long-term recurrence of AF.

Methods

Patients with paroxysmal AF underwent cryoballoon PVI. After PVI, adenosine 25 mg was infused to test for dormant muscular sleeves in each vein. If reconnection under adenosine was shown, further cryoballoon ablation was performed until no more reconnection occurred. Follow-up was performed with ECG, 24-h Holter recording, and a symptom questionnaire at three monthly intervals. Transtelephonic Holter monitoring was performed for 1 month before and 3 months after PVI. Patients who underwent cryoballoon PVI without adenosine administration were used as controls for comparison.

Results

In the study group (n = 34, 24 males), adenosine revealed dormant sleeves in 9/132 (8 %) veins, and 7/34 (21 %) patients. All but one vein was further treated until the dormant sleeves were isolated. During a mean follow-up of 520 ± 147 days, 23/34 (68 %) patients were free of AF without antiarrhythmic drugs (AADs). In the control group (n = 65, 46 males), 29/65 (46 %) were free of AF without AADs. There were significantly less AF recurrences in the study group (p = 0.04).

Conclusions

Adenosine administration after cryoballoon PVI reveals dormant muscular sleeves in 21 % of patients. Clinical follow-up shows that adenosine testing is effective in reducing AF recurrence after cryoballoon ablation.  相似文献   

2.

Background

The relationship between focal pulmonary vein potential and atrial fibrillation (AF) has been confirmed. Pulmonary vein (PV) isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation.

Methodology

For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD) were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up.

Principal Findings

During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05). Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

Conclusions

The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.  相似文献   

3.

Background

Ganglionated plexi (GP) ablation has been become an adjunct to pulmonary vein isolation (PVI). This study describes the long-term results of minimally invasive surgical PVI, ablation of GPs, and exclusion of the left atrial appendage for atrial fibrillation (AF).

Methods

Long-term follow-up of 55 months was performed in 139 consecutive patients (age 58.3±20.8 years) with symptomatic, drug-refractory lone AF who underwent minimally invasive surgical PVI, GPs ablation, and exclusion of the left atrial appendage. Success was defined as freedom from AF, atrial flutter, or atrial tachycardia off antiarrhythmic drugs.

Results

AF was paroxysmal in 77.7%, persistent in 12.2% and long-standing persistent in 10.1%. Single-procedure success rate was 71.7%, 59.4% and 46.6% at 12, 24 and 60 months respectively. Single-procedure success rate was 72.9%, 62.6% and 51.8% for paroxysmal AF, 64.7%, 35.3%, and 28.2% for persistent AF, 71.4%, 64.3% and 28.6% for long-standing persistent AF at 12, 24 and 60 months respectively. Duration of AF>24 months (hazard ratio [HR]: 3.09, 95% confidence interval [CI]: 1.51 to 6.32; p = 0.002), left atrial diameter≥40 mm (HR: 4.03, 95% CI: 1.88 to 8.65; p<0.001), early recurrence of AF (HR: 4.66, 95% CI: 2.25 to 9.63; p<0.001) independently predicted long-term recurrence of AF. There was no procedure-related death. One patient converted to median sternotomy because of uncontrolled bleeding. Two patients underwent perioperative cerebrovascular events.

Conclusions

At nearly 5-year of clinical follow-up, single-procedure success rate of minimally invasive surgical PVI with GP ablation was 51.8% for paroxysmal AF, 28.2% for persistent AF, 28.6% for long-standing persistent AF after initial procedure. Patients with AF duration≤24 months, left atrial diameter<40 mm and no early recurrence of AF, had favorable outcomes.  相似文献   

4.

Background

It is suggested that an elevated left atrial pressure (LAP) promotes ectopic beats emanating in the pulmonary veins (PVs) and that LAP might be a marker for structural remodeling. This study aimed to identify if the quantification of LAP correlates with structural changes of the LA and may therefore be associated with outcomes following pulmonary vein isolation (PVI).

Methods

We analysed data from 120 patients, referred to PVI due to drug-refractory atrial fibrillation (AF) (age 63±8; 57% men). The maximum (mLAP) and mean LAP (meLAP) were measured after transseptal puncture.

Results and Conclusions

Within a mean follow-up of 303±95 days, 60% of the patients maintained in sinus rhythm after the initial procedure and 78% after repeated PVI. Performing univariate Cox-regression analysis, type of AF, LA-volume (LAV), mLAP and the meLAP were significant predictors of recurrence after PVI (p=0.03; p=0.001; p=0.01). In multivariate analysis mLAP>18mmHg, LAV>100 ml and the presence of persistent AF were significant predictors (p=0.001; p=0.019; p=0.017). The mLAP >18 mmHg was associated with a hazard ratio of 3.8. Analyzing receiver-operator characteristics, the area under the curve for mLAP was 0.75 (p<0.01). mLAP >18 mmHg predicts recurrence with a sensitivity of 77 % and specificity of 60 %. There was a linear correlation between the LAV from MDCT and mLAP (p = 0.01, R2 = 0.61). The mLAP measured invasively displays a significant predictor for AF recurrence after PVI. There is a good correlation between LAP and LAV and both factors may be useful to quantify LA remodeling.  相似文献   

5.

Background

The aim of the study was to compare in our center the effect of different ablation techniques on intermediate term freedom from atrial fibrillation (AF) or atrial tachycardia (AT) in patients affected by refractory AF.

Methods and Results

We retrospectively selected 94 patients who underwent AF ablation in our electrophysiological laboratory from June 2007 to December 2009. 29 patients underwent manual circumferential pulmonary vein isolation (mCPVI), 35 underwent remote magnetic navigation assisted CPVI (rmtCPVI) and 30 cryoballoon CPVI (cCPVI). Antiarrhythmic drugs were systematically stopped 2 months after the procedure (end of the "blanking period").At a mean follow-up of 12,64 ± 6,41 months (range 2-31), the success rate for mCPVI group was 65.5% (19 patients), 66.7 % (20 patients) for the rmtCPVI group and 65.7 % (23 patients) for the cCPVI group (p = 0.625). Procedural and fluoroscopy times were significantly reduced in the cCPVI group (both p < 0.001). Univariate Cox regression showed that no clinical variables were independently associated with recurrence.

Conclusions

In our center''s experience cCPVI and rmtCPVI have been demonstrated to be as effective as mCPVI. cCPVI seemed to be associated with lower procedural and fluoroscopy times.  相似文献   

6.

Background

Silent cerebral events (SCE) have been identified on magnetic resonance imaging (MRI) in asymptomatic patients after atrial fibrillation (AF) ablation. Procedural determinants influencing the risk for SCE still remain unclear.

Objective

Comparing the risk for SCE depending on exchanges of catheters (ExCath) over a single transseptal sheath.

Methods

88 Patients undergoing pulmonary vein isolation (PVI) only ablation using either single-tip or balloon-based technique underwent pre- and post-ablation cerebral MRI. Ablations were either performed with double transseptal access and without exchanging catheters over the transseptal sheaths (group 1: no ExCath) or after a single transseptal access and exchanges of therapeutic and diagnostic catheters (group 2: ExCath). Differences in regard to SCE rates were analyzed. Multivariate analysis was performed to identify factors related to the risk for SCE.

Results

Included patients underwent PVI using single tip irrigated radiofrequency in 41, endoscopic laser balloon in 27 and cryoballoon in 20 cases. Overall SCE were identified in 23 (26%) patients. In group 1 (no ExCath; N=46) 6 patients (13%) and in group 2 (N=42) 17 patients (40%) had documented SCE (p=0.007). The applied ablation technology did not affect SCE rate. In multivariate analysis age (OR 1.1, p=0.03) and catheter exchanges over a single transseptal sheath (OR 12.1, p=0.007) were the only independent predictors of a higher risk for SCE.

Conclusions

Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.  相似文献   

7.

Introduction

Pulmonary vein reconnection after pulmonary vein isolation (PVI) is a significant problem in the treatment of paroxysmal atrial fibrillation (AF). We report about patients who underwent contact force (CF) guided PVI using CF catheter and compared them to patients with PVI using an ablation catheter with enhanced tip irrigation.

Methods

A total of 59 patients were included in the analysis. In 30 patients circumferential PVI was performed using the Thermocool Smarttouch® ablation catheter (ST) whereas in 29 patients circumferential PVI using the Thermocool Surround Flow SF® ablation catheter (SF) was performed. Patients were compared in regard to procedure time, fluoroscopy time/dose as well as RF-application duration and completeness of PVI. Adverse events (pericardial effusion, PV stenosis, stroke, death) were evaluated. The presence of sinus rhythm off antiarrhythmic medication was assessed during 6 months follow-up using multiple 7 day Holter-ECGs.

Results

In both groups, all PVs were isolated without serious adverse events. Procedure time was 2.15 ± 0.5 h (ST) vs. 2.37 ± 1.13 h (SF) (p = 0.19). Duration of RF-applications was 46.6 ± 18 min (ST) and 49.8 ± 19 min (SF) (p = 0.52). Fluoroscopy time was 25.2 ± 13 min (ST) vs. 29 ± 18 min (SF), fluoroscopy dose 2675.6 ± 1658 versus 3038.3 ± 1997 cGym2 (p = 0.36 and 0.46 respectively). Sinus rhythm off antiarrhythmic medication validated with 7 day Holter ECGs was present in both groups in 72% of patients after 6 months of follow up.

Conclusion

PVI using the new contact force catheter is safe and effective in patients with paroxysmal AF.  相似文献   

8.

Background

Cryoballoon-based pulmonary vein isolation (PVI) is a treatment option for atrial fibrillation (AF). Left atrial volume (LAV) and left atrial volume index (LAVi) are important parameters for long term success of PVI. Galectin-3 (Gal-3) and neutrophil to lymphocyte ratio (N/L ratio) are biomarkers to demonstrate the cardiac fibrosis and remodelling.

Methods

50 patients with symptomatic PAF despite ≥1 antiarrhythmic drug(s), who underwent PVI were enrolled. LAV, LAVi, Gal-3 and N/L ratio were calculated before ablation and after ablation at 6 and 12 months. According to AF recurrence patients were divided into two groups, recurrent AF (n?=?14) and non-recurrent AF (n?=?36).

Results

In both groups (recurrent and non-recurrent), initial and 12 months follow-up LAV values were 41.39?±?18.13?ml and 53.24?±?22.11?ml vs 48.85?±?12.89?ml and 42.08?±?13.85 (p?=?0.037). LAVi were 20.9?±?8.91 ml/m2 and 26.85?±?11.28 ml/m2 vs 25.36?±?6.21 and 21.87?±?6.66 (p?=?0.05) for recurrent and non-recurrent AF groups, respectively. In both groups PVI had no significant effect on serum Gal-3 levels and N/L ratio during 12 months follow-up. The comparison between two groups at the end of 12th month showed Gal-3 values of 6.66?±?4.09?ng/ml and 6.02?±?2.95?ng/ml (p?=?0.516), N/L ratio values of 2.28?±?1.07 103/μl and 1.98?±?0.66?103/μl (p?=?0.674).

Conclusion

LAV and LAVi are useful to predict the remodelling of the left atrium and AF recurrence after cryoballoon-based PVI. However, biomarkers such as Gal-3 and N/L ratio are not associated with AF recurrence.  相似文献   

9.

Introduction

The advent of electroanatomical mapping (EAM) systems for pulmonary vein isolation (PVI) has dramatically decreased radiation exposure. However, the need for some fluoroscopy remains for obtaining left atrial (LA) access. The aim was to test the feasibility of fluoroscopy-free PVI in patients with atrial fibrillation (AF) and a patent foramen ovale (PFO) guided solely by an EAM system.

Methods

Consecutive patients with AF undergoing PVI and documented PFO were studied. An EAM-guided approach without fluoroscopy and ultrasound was used. After completing the map of the right atrium, the superior vena cava and the coronary sinus, a catheter pull-down to the PFO was performed allowing LA access. The map of the LA and subsequent PVI was also performed without fluoroscopy.

Results

30 patients [age 61±12 years, 73% male, ejection fraction 0.64 (0.53–0.65), LA size in parasternal long axis 38±7 mm] undergoing PVI were included. The time required for right atrial mapping including transseptal crossing was 9±4 minutes. Total procedure time was 127±37 minutes. Fluoroscopy-free PVI was feasible in 26/30 (87%) patients. In four patients, fluoroscopy was needed to access (n = 3) or to re-access (n = 1) the LA. In these four patients, total fluoroscopy time was 5±3 min and the DAP was 14.9±13.4 Gy*cm2. Single-procedure success rate was 80% (24/30) after a median follow-up of 12 months.

Conclusion

In patients with a documented PFO, completely fluoroscopy-free PVI is feasible in the vast majority of cases.  相似文献   

10.

Background

Paroxysmal atrial fibrillation (PAF) is defined as recurrent AF terminating spontaneously within 7 days. This definition allows the consideration of any AF occurrence lasting < 7 days as paroxysmal, irrespective of the frequency and duration of episodes. The aim of this study was to investigate symptomatic AF burden (AFB) defined as total duration of symptomatic AF episodes within 3 months prior to abalation, for prediction of outcome after pulmonary vein isolation (PVI).

Methods

A total of 320 consecutive patients with symptomatic AF (PAF=244, men=214, age=58 y) were enrolled. AFB in patients with PAF was defined as time spent in AF within 3 months prior to PVI. After the AFB cut-off point was optimized at 500 h, patients with PAF were categorized into 2 groups: Group 1 - patients with AFB< 500 h (n=192), Group 2 - patients with AFB≥ 500 h (n=52). Patients with persistent AF (PersAF, n = 76) comprised control group (Group 3). PVI was performed either with irrigated tip catheter (n=215) or using cryoballoon (n=105). The endpoint of study was first documented recurrence of AF >30 sec.

Results

Symptomatic AFB was found to be appropriate for prediction of outcome after PVI. The freedom from AF within 2 years was observed in 69%, 31%, and 43% patients in Group 1, 2 and 3, respectively (Group 1 vs. Group 2, p < .001; Group 1 vs. Group 3, p< .001; Group 2 vs. Group 3, p = 0.46).

Conclusions

Low AFB < 500 h /3 months was associated with better outcome after PVI. Patients with PAF and high AFB should be treated as patients with PersAF.  相似文献   

11.

Introduction

Recurrence of atrial fibrillation after pulmonary vein isolation (PVI) occurs frequently and may be associated with electrical reconnection of the pulmonary veins (PV). We investigated spatial distribution of electrical reconnection during re-do procedures in patients with paroxysmal atrial fibrillation who had previous successful acute electrical PVI with either single irrigated tip, antral ablation (s-RF; n = 38) or multi-electrode, duty-cycled ablation (PVAC; n = 48).

Methods and Results

EP navigator, mapping and irrigated tip ablation catheters were used in all re-do procedures. Sites of reconnection were assessed in a 12-segment model. Baseline clinical and demographic characteristics were similar in both groups. The number of PVs reconnected per patient was similar in both groups (2.9 ± 0.9 and 3.2 ± 0.7 (p = 0.193), s?RF and PVAC, respectively), and each PV was equally affected. However, the inferior quadrant of the right lower PV was significantly more vulnerable to reconnection after previous PVAC ablation, whereas the superior quadrant of the right upper PV showed significantly more reconnection in the s?RF group.

Conclusion

The overall number of PVs reconnected was equally high in both groups, and each PV was affected equally. However, there were significant differences in the spatial distribution of electrical reconnection. Better understanding of predilection sites for reconnection might help to improve the long-term success rate of PVI.
  相似文献   

12.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

13.

Background

Recent studies have demonstrated that radiofrequency isolation of the pulmonary veins (PVI) is an effective treatment for symptomatic atrial fibrillation. Based on these positive results, non- pharmacological therapy has been incorporated in the guidelines for drug refractory atrial fibrillation, resulting in an increased popularity. The prevention of thromboembolic complications remains an important issue.

Methods

In January 2010, we adopted an anticoagulation strategy based on continuation of vitamin K antagonists (VKAs) and selective use of transoesophageal echocardiogram (TEE). We retrospectively analysed the results of this strategy in all patients referred for PVI treatment. VKAs were started for all patients 2 months prior to treatment. Discontinuation of oral anticoagulation was considered 3 months after treatment based on thromboembolic and bleeding risk profile. Bleeding and thromboembolic complications were registered during outpatient clinic follow-up up until 3 months.

Results

We performed 151 PVI procedures from January 2010 to March 2011. All patients were seen 6 weeks after discharge. No transient ischaemic accidents or ischaemic cerebrovascular incidents occurred pre-, peri- or postprocedure. Four (2.7%) procedures were complicated by tamponade requiring pericardiocentesis.

Conclusions

Our data support the increasing evidence for continuation of periprocedural administration of VKAs complemented by a selective TEE approach as a safe therapy for thromboembolic complications.  相似文献   

14.

Background

Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Elective electrical cardioversion is often performed in patients with persistent AF to attempt sinus rhythm (SR) restoration. However, AF recurrences are frequent after successful cardioversion and several predictors have been identified.

Aim of the study

The present study was designed to prospectively analyse the correlation between NT-pro-BNP levels and AF recurrence in consecutive patients referred for electrical cardioversion of persistent atrial fibrillation.

Results

Forty consecutive patients referred for elective cardioversion of AF were enrolled in the study. Cardioversion restored sinus rhythm in 34/40 patients but 2 of them presented an early recurrence of AF before discharge. Patients were then followed for 6 months to assess AF recurrence. Cox regression analysis was performed using the parameters found predictive on univariate survival analysis (NT-pro-BNP quartiles, beta-blockers). The only independent predictor of AF recurrence on Cox-regression analysis was a level of NT-pro-BNP in the fourth quartile (HR 3.21 95%CI 1.26-8.14, p=0.014). On receiver operating curve (ROC) analysis, NT-pro-BNP levels above 1707 pg/ml had a specificity of 92% (and a sensitivity of 36%) in predicting atrial fibrillation recurrence by 6 months.

Conclusions

Baseline NT-pro-BNP levels are an independent predictor of AF recurrence at 6 months follow-up in candidates for elective direct current cardioversion.  相似文献   

15.

Aims

Cryoballoon pulmonary vein (PV) isolation in patients with atrial fibrillation has proven to be effective in short-term and long-term follow-up. To visualise the PV anatomy, pre-ablation contrast pulmonary venography is commonly performed. Three-dimensional (3D) computed tomography (CT) overlay is a new technique creating a live 3D image of the left atrium by integrating a previously obtained CT scan during fluoroscopy. To evaluate the benefits of 3D CT overlay during cryoballoon ablation, we studied the use of 3D CT overlay versus contrast pulmonary venography in a randomised fashion in patients with paroxysmal atrial fibrillation undergoing cryoballoon PV isolation.

Methods and results

Between October 2012 and June 2013, 30 patients accepted for PV isolation were randomised to cryoballoon PV isolation using either 3D CT overlay or contrast pulmonary venography. All patients underwent a pre-procedural cardiac CT for evaluation of the anatomy of the left atrium (LA) and the PVs. In the 3D CT overlay group, a 3D reconstruction of the LA and PVs was made. An overlay of the CT reconstruction was then projected over live fluoroscopy. Patients in the contrast pulmonary venography group received significantly more contrast agent (77.1 ± 21.2 cc vs 40.1 ± 17.6 cc, p < 0.001) and radiation (43.0 ± 21.9?Gy.cm2 vs 28.41 ± 11.7?Gy.cm2, p = 0.04) than subjects in the 3D CT overlay group. There was no difference in total procedure time, fluoroscopy time and the amount of cryoapplications between the two groups.

Conclusion

The use of 3D CT overlay decreases radiation and contrast dye exposure and can assist in guiding cryoballoon-based PV isolation.
  相似文献   

16.
IntroductionThe endoscopic laser balloon ablation system (EAS) is a relatively novel technique to perform pulmonary vein isolation (PVI) in the treatment of atrial fibrillation (AF). The present study aimed to report the results of the first 50 patients treated in the Netherlands with the EAS in terms of procedural characteristics and AF-free survival.MethodsFifty patients successfully underwent EAS PVI. Median follow-up was 17 months. Mean age was 56 years, 82 % had paroxysmal AF.Results99 % of the pulmonary veins were successfully isolated with the EAS. Mean procedure time was 171 min and mean fluoroscopy time was 36 min. One procedure was complicated by a temporary phrenic nerve palsy (2 %). During follow-up, 58 % of patients remained free of AF without the use of antiarrhythmic drugs.ConclusionPVI with EAS is associated with a low risk of complications and a medium-term AF-free survival comparable with other PVI techniques.

Electronic supplementary material

The online version of this article (doi:10.1007/s12471-014-0624-y) contains supplementary material, which is available to authorized users.  相似文献   

17.

Objective

To assess the outcome and associated risks of atrial defragmentation for the treatment of long-standing persistent atrial fibrillation (LSP-AF).

Methods

Thirty-seven consecutive patients (60.4 ± 7.3 years; 28 male) suffering from LSP-AF who underwent pulmonary vein isolation (PVI) and linear ablation were compared. All patients were treated with the Stereotaxis magnetic navigation system (MNS). Two groups were distinguished: patients with (n = 20) and without (n = 17) defragmentation. The primary endpoint of the study was freedom of AF after 12 months. Secondary endpoints were AF termination, procedure time, fluoroscopy time and procedural complications. Complications were divided into two groups: major (infarction, stroke, major bleeding and tamponade) and minor (fever, pericarditis and inguinal haematoma).

Results

No difference was seen in freedom of AF between the defragmentation and the non-defragmentation group (56.2 % vs. 40.0 %, P = 0.344). Procedure times in the defragmentation group were longer; no differences in fluoroscopy times were observed. No major complications occurred. A higher number of minor complications occurred in the defragmentation group (45.0 % vs. 5.9 %, P = 0.009). Mean hospital stay was comparable (4.7 ± 2.2 vs. 3.4 ± 0.8 days, P = 0.06).

Conclusion

Our study suggests that complete defragmentation using MNS is associated with a higher number of minor complications and longer procedure times and thus compromises efficiency without improving efficacy.  相似文献   

18.

Objective

Reconduction across an ablation line is a common reason for arrhythmia recurrence over time. The hybrid procedure combines epicardial ablation of the pulmonary vein (PV) and creation of a box lesion with endocardial touch-ups for any electrical gaps. A high contact force (CF) between the ablation tip and cardiac tissue may increase the risk of thrombus formation, catheter tip charring, steam pop formation, and even cardiac perforation. CF monitoring is a significant new parameter for titration of the CF for creating an adequate lesion.

Methods

Thirty-eight consecutive patients underwent epicardial ablation using bipolar radiofrequency devices. After checking electrical bidirectional block of the ablation lines, an endocardial CF catheter was used for further ablation (if needed) to complete the isolation of PVs, box lesion, cavotricuspid isthmus (CTI), and complex fractionated atrial electrograms (CFAE).

Results

Endocardial touch-up was needed for 2 PVs (1.3 %) and 10 (26.3 %) box lesions. It was also used for the CTI line in 7 (18.4 %) patients, atrial tachycardia in 3 (7.9 %) patients, and additional CFAE ablation in 17 (44.7 %) patients. All 5 patients with arrhythmia recurrence had a mean CF < 10 g (p = 0.03). Procedure duration was significantly shorter in the CF group (223 ± 57 vs. 256 ± 60 min, p = 0.03) compared with control group.

Conclusion

Use of CF catheters is safe, feasible, and complementary to a hybrid procedure setup for atrial fibrillation ablation. Its real-time monitoring may predict future arrhythmia recurrence, and decrease procedure time.  相似文献   

19.

Background

To facilitate the creation of circumferential lines in pulmonary vein (PV) antrum isolation, three-dimensional (3D) navigation systems are used widely. Alternatively, 3D reconstructions of the left atrium (LA) can be superimposed directly on fluoroscopy to guide ablation catheters and to mark ablation sites.

Methods

In 71 atrial fibrillation patients circumferential PV ablation was performed. 3D reconstructions of the LA were derived from contrast cardiac-computed tomography and circumferential PV isolation was performed. In subsequent ablation procedures, veins were re-isolated, and defragmentation or linear lesions were performed if necessary.

Results

Adequate 3D reconstructions were formed and registered to fluoroscopy in all patients. All veins, except 2 in one single patient, could be isolated, resulting in freedom of AF in 45 patients (63?%). In 19 patients a second procedure was performed, in which 2.7?±?1.1 PV per patient were re-isolated; in 3 patients a third procedure was performed. After follow-up of 15?±?8?months, 51 (91?%) of patients with paroxysmal and 10 (67?%) with persistent AF were free of AF.

Conclusions

The results of 3D overlay for circumferential PV isolation are good, although the reconduction rate and need for subsequent ablations remains high, and the outcomes of this technique appear to be equivalent to other mapping techniques.  相似文献   

20.

Background

Pulmonary vein (PV) reconduction after PV isolation (PVI) unmasked by adenosine is associated with a higher risk for paroxysmal atrial fibrillation (PAF) recurrence. It is unknown if the reconnected PVs after adenosine testing and immediate re-ablation can predict reconnection and reconnection patterns of PVs at repeat procedures. We assessed reconnection of PVs with and without dormant-conduction (DC) during the first and the repeat procedure.

Methods

We included 67 patients undergoing PVI for PAF and a second procedure for PAF recurrence. DC during adenosine administration at first procedure was seen in 31 patients (46%). 264 PVs were tested with adenosine; DC was found in 48?PVs (18%) and re-ablated during first procedure. During the second procedure, all PVs where checked for reconnection.

Results

Fifty-eight patients (87%) showed PV reconnection during the second procedure. Reconnection was found in 152/264?PVs (58%). Of 216?PVs without reconnection during adenosine testing at the first ablation, 116?PVs (53.7%) showed reconnection at the repeat procedure. Overall, 14.9% of patients showed the same PV reconnection pattern in the first and second procedure, expected statistical probability of encountering the same reconnection pattern was only 6.6%(p?=?0.012).

Conclusions

In repeat procedures PVs showed significantly more often the same reconnection pattern as during first procedure than statistically expected. More than 50% of initial isolated PVs without reconnection during adenosine testing showed a reconnection during repeat ablation. Techniques to detect susceptibility for PV re-connection like prolonged waiting-period should be applied. Elimination of DC should be expanded from segmental to circumferential re-isolation or vaster RF application.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号