首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The lack of specific, low-cost, rapid, sensitive, and easy detection of biomolecules has resulted in the development of biosensor technology. Innovations in biosensor technology have enabled many biosensors to be commercialized and have enabled biomolecules to be detected onsite. Moreover, the emerging technologies of lab-on-a-chip microdevices and nanosensors offer opportunities for the development of new biosensors with much better performance. Biosensors were first introduced into the laboratory by Clark and Lyons. They developed the first glucose biosensor for laboratory conditions. Then in 1973, a glucose biosensor was commercialized by Yellow Springs Instruments. The commercial biosensors have small size and simple construction and they are ideal for point-of-care biosensing. In addition to glucose, a wide variety of metabolites such as lactate, cholesterol, and creatinine can be detected by using commercial biosensors. Like the glucose biosensors (tests) other commercial tests such as for pregnancy (hCG), Escherichia coli O157, influenza A and B viruses, Helicobacter pylori, human immunodeficiency virus, tuberculosis, and malaria have achieved success. Apart from their use in clinical analysis, commercial tests are also used in environmental (such as biochemical oxygen demand, nitrate, pesticide), food (such as glutamate, glutamine, sucrose, lactose, alcohol, ascorbic acid), and biothreat/biowarfare (Bacillus anthracis, Salmonella, Botulinum toxin) analysis. In this review, commercial biosensors in clinical, environmental, food, and biowarfare analysis are summarized and the commercial biosensors are compared in terms of their important characteristics. This is the first review in which all the commercially available tests are compiled together.  相似文献   

2.
The review discusses the diagnostic application of biosensors as point-of-care devices in the COVID-19 pandemic. Biosensors are important analytical tools that can be used for the robust and effective detection of infectious diseases in real-time. In this current scenario, the utilization of smart, efficient biosensors for COVID-19 detection is increasing and we have included a few smart biosensors such as smart and intelligent based biosensors, plasmonic biosensors, field effect transistor (FET) biosensors, smart optical biosensors, surface enhanced Raman scattering (SERS) biosensor, screen printed electrode (SPE)-based biosensor, molecular imprinted polymer (MIP)-based biosensor, MXene-based biosensor and metal–organic frame smart sensor. Their significance as well as the benefits and drawbacks of each kind of smart sensor are mentioned in depth. Furthermore, we have compiled a list of various biosensors which have been developed across the globe for COVID-19 and have shown promise as commercial detection devices. Significant challenges in the development of effective diagnostic methods are discussed and recommendations have been made for better diagnostic outcomes to manage the ongoing pandemic effectively.  相似文献   

3.
Survey of the 1998 optical biosensor literature   总被引:3,自引:0,他引:3  
The utilization of optical biosensors to study molecular interactions continues to expand. In 1998, 384 articles relating to the use of commercial biosensors were published in 130 different journals. While significant strides in new applications and methodology were made, a majority of the biosensor literature is of rather poor quality. Basic information about experimental conditions is often not presented and many publications fail to display the experimental data, bringing into question the credibility of the results. This review provides suggestions on how to collect, analyze and report biosensor data.  相似文献   

4.
We have developed a new method for highly selective determination of the ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) concentration using a surface plasmon resonance imaging (SPRI) technique and two different biosensors. UCH-L1 was captured from a solution by immobilized specific rabbit monoclonal antibody or specific LDN-57444 inhibitor due to formation of receptor–UCH-L1 complex on the biosensor surface. The analytically useful dynamic response range of both biosensors is between 0.1 and 2.5 ng/ml. The detection limit is 0.06 ng/ml for the biosensor with antibody and 0.08 ng/ml for the biosensor with inhibitor. Biosensors based on both antibody and inhibitor were found to be suitable for quantitative determination of the UCH-L1 and exhibit good tolerance to the potential interferents. Both biosensors gave comparable results in the range of 0 to 0.20 ng/ml for plasma samples and 0.30 to 0.49 ng/ml for cerebrospinal fluid samples. To validate the new methods, comparative determination of UCH-L1 by the commercial enzyme-linked immunosorbent assay (ELISA) kit was performed. In general, in terms of UCH-L1 concentration, a good correlation between SPRI and ELISA was found. The developed biosensors can be used successfully for the determination of UCH-L1 in body fluids.  相似文献   

5.
A survey of the year 2002 commercial optical biosensor literature   总被引:2,自引:0,他引:2  
We have compiled 819 articles published in the year 2002 that involved commercial optical biosensor technology. The literature demonstrates that the technology's application continues to increase as biosensors are contributing to diverse scientific fields and are used to examine interactions ranging in size from small molecules to whole cells. Also, the variety of available commercial biosensor platforms is increasing and the expertise of users is improving. In this review, we use the literature to focus on the basic types of biosensor experiments, including kinetics, equilibrium analysis, solution competition, active concentration determination and screening. In addition, using examples of particularly well-performed analyses, we illustrate the high information content available in the primary response data and emphasize the impact of including figures in publications to support the results of biosensor analyses.  相似文献   

6.
A new method of preparing fiber-optic DNA biosensor and its array for the simultaneous detection of multiple genes is described. The optical fibers were first treated with poly-l-lysine, and then were made into fiber-optic DNA biosensors by adsorbing and immobilizing the oligonucleotide probe on its end. By assembling the fiber-optic DNA biosensors in a bundle in which each fiber carried a different DNA probe, the fiber-optic DNA biosensor array was well prepared. Hybridization of fluorescent- labeled cDNA of p53 gene, N-ras gene and Rb1 gene to the DNA array was monitored by CCD camera. A good result was achieved.  相似文献   

7.
Despite the amount of resources that have been invested by national and international academic, government, and commercial sectors to develop affinity-based biosensor products, little obvious success has been realized through commercialization of these devices for specific applications (such as the enzyme biosensors for blood glucose analysis). Nevertheless, the fastest growing area in the biosensors research literature continues to involve advances in affinity-based biosensors and biosensor-related methods. Numerous biosensor techniques have been reported that allow researchers to better study the kinetics, structure, and (solid/liquid) interface phenomena associated with protein-ligand binding interactions. In addition, potential application areas for which affinity-based biosensor techniques show promise include clinical/diagnostics, food processing, military/antiterrorism, and environmental monitoring. The design and structural features of these devices—composed of a biological affinity element interfaced to a signal transducer—primarily determine their operational characteristics. This paper although not intended as a comprehensive review, will outline the principles of affinity biosensors with respect to potential application areas.  相似文献   

8.
The biosensor field has grown enormously since the first demonstration of the biosensor concept by Leland C. Clark, Jr. in 1962. Today's biosensor market is dominated by glucose biosensors, mass-produced enzyme electrodes for the rapid self-diagnosis of blood glucose levels by diabetes sufferers. Here we take a historical look at the inception, growth, and development of the enzyme biosensor field from a commercial viewpoint. The current status of the technology is evaluated and future trends in this dynamic and fastmoving field are also anticipated.  相似文献   

9.
Survey of the year 2004 commercial optical biosensor literature   总被引:4,自引:0,他引:4  
The year 2004 represents a milestone for the biosensor research community: in this year, over 1000 articles were published describing experiments performed using commercially available systems. The 1038 papers we found represent an approximately 10% increase over the past year and demonstrate that the implementation of biosensors continues to expand at a healthy pace. We evaluated the data presented in each paper and compiled a 'top 10' list. These 10 articles, which we recommend every biosensor user reads, describe well-performed kinetic, equilibrium and qualitative/screening studies, provide comparisons between binding parameters obtained from different biosensor users, as well as from biosensor- and solution-based interaction analyses, and summarize the cutting-edge applications of the technology. We also re-iterate some of the experimental pitfalls that lead to sub-optimal data and over-interpreted results. We are hopeful that the biosensor community, by applying the hints we outline, will obtain data on a par with that presented in the 10 spotlighted articles. This will ensure that the scientific community at large can be confident in the data we report from optical biosensors.  相似文献   

10.
Survey of the 1999 surface plasmon resonance biosensor literature   总被引:7,自引:0,他引:7  
The application of surface plasmon resonance biosensors in life sciences and pharmaceutical research continues to increase. This review provides a comprehensive list of the commercial 1999 SPR biosensor literature and highlights emerging applications that are of general interest to users of the technology. Given the variability in the quality of published biosensor data, we present some general guidelines to help increase confidence in the results reported from biosensor analyses.  相似文献   

11.
With the escalation of drug discovery programmes, it has become essential to visualize and monitor biological activities in healthy and pathological cells, with high spatial and temporal resolution. To this aim, the development of probes and sensors, which can report on the levels and activities of specific intracellular targets, has become essential. Together with the discovery of the Green Fluorescent Protein (GFP), and the development of GFP-based reporters, recent advances in the synthesis of small molecule fluorescent probes, and the explosion of fluorescence-based imaging technologies, the biosensor field has witnessed a dramatic expansion of fluorescence-based reporters which can be applied to complex biological samples, living cells and tissues to probe protein/protein interactions, conformational changes and posttranslational modifications. Here, we review recent developments in the field of fluorescent biosensor technology. We describe different varieties and categories of fluorescent biosensors together with an overview of the technologies commonly employed to image biosensors in cellulo and in vivo. We discuss issues and strategies related to the choice of synthetic fluorescent probes, labelling, quenching, caging and intracellular delivery of biosensors. Finally, we provide examples of some well-characterized genetically encoded FRET reporter systems, peptide and protein biosensors and describe biosensor applications in a wide variety of fields.  相似文献   

12.
生物传感芯片是一类综合了生物芯片和生物传感器的优点的新型生物芯片,在保持传统生物芯片的高通量、可寻址、并行处理等特点的基础上,与生物传感器技术相结合,进一步提高了芯片检测的灵敏度和特异性。常见的生物传感芯片主要有光纤传感芯片、表面等离子体共振传感芯片、热生物传感芯片、压电晶体传感芯片等,可用于各种生物大分子,如蛋白质、核酸等的检测,金属离子的测定,病原体的检测,药物筛选等。  相似文献   

13.
A new method of preparing fiber-optic DNA biosensor and its array for the simultaneous detection of multiple genes is described. The optical fibers were first treated with poly-1-lysine, and then were made into fiber-optic DNA biosensors by adsorbing and immobilizing the oligonucleotide probe on its end. By assembling the fiber-optic DNA biosensors in a bundle in which each fiber carried a different DNA probe, the fiber-optic DNA biosensor array was well prepared. Hybridization of fluorescent- labeled cDNA ofp53 gene,N-ras gene andRb1 gene to the DNA array was monitored by CCD camera. A good result was achieved.  相似文献   

14.
Mixing deficiencies can be potentially detected by the use of a dedicated whole cell microbial biosensor. In this work, a csiE promoter induced under carbon-limited conditions was involved in the elaboration of such biosensor. The cisE biosensor exhibited interesting response after up and down-shift of the dilution rate in chemostat mode. Glucose limitation was accompanied by green fluorescent protein (GFP) leakage to the extracellular medium. In order to test the responsiveness of microbial biosensors to substrate fluctuations in large-scale, a scale-down reactor (SDR) experiment was performed. The glucose fluctuations were characterized at the single cell level and tend to decrease the induction of GFP. Simulations run on the basis of a stochastic hydrodynamic model have shown the variability and the frequencies at which biosensors are exposed to glucose gradient in the SDR. GFP leakage was observed to a great extent in the case of a culture operated in well-mixed fed-batch mode, by comparison with those operated in SDR. GFP leakage seems to be correlated to a higher membrane permeability, confirming previous studies highlighting a better cell viability in cultures operated in a fluctuating environment. Our results suggest that GFP leakage could be used in parallel to the normal GFP biosensor function in order to assess microbial viability in process conditions.  相似文献   

15.
Amperometric glucose biosensors utilizing commercially available FAD-dependent glucose dehydrogenases from two strains of Aspergillus species are described. Enzymes were immobilized on nanocomposite electrode consisting of multi-walled carbon nanotubes by entrapment between chitosan layers. Unlike the common glucose oxidase based biosensor, the presented biosensors appeared to be O(2)-independent. The optimal amount of enzymes, working potential and pH value of working media of the glucose biosensors were determined. The biosensor utilizing enzyme isolated from Aspergillus sp. showed linearity over the range from 50 to 960 μM and from 70 to 620 μM for enzyme from Aspergillus oryzae. The detection limits were 4.45 μM and 4.15 μM, respectively. The time of response was found to be 60 s. The biosensors showed excellent operational stability - no loss of sensitivity after 100 consecutive measurements and after the storage for 4 weeks at 4 °C in phosphate buffer solution. When biosensors were held in a dessicator at room temperature without use, they kept the same response ability at least after 6 months. Finally, the results obtained from measurements of beverages and wine samples were compared with those obtained with the enzymatic-spectrophotometric and standard HPLC methods, respectively. Good correlation between results in case of analysis of real samples and good analytical performance of presented glucose biosensor allows to use presented concept for mass production and commercial use.  相似文献   

16.
Glucose oxidase (GOD) was genetically modified by adding a poly-lysine chain at the C-terminal with a peptide linker inserted between the enzyme and poly-lysine chain. The poly-lysine chain was added in order to anchor more electron transfer mediator, ferrocenecarboxylic acid, to GOD for the purpose of improving sensitivity and stability of glucose biosensors. The modified GOD had similar K(m) and K(cat) to those of the wild type enzyme. After interacted with the electron transfer mediator, the modified enzyme retained 90.01% of its native activity, while the commercial GOD and the wild type GOD (Aspergillus niger) retained only 22.43 and 22.17%, respectively. Screen-printed electrodes coated with the modified GOD, wild type yeast-derived GOD or the commercial GOD were tested in glucose solution of different concentrations. Experimental results showed that the biosensor based on the modified GOD gave the largest signal among the three. In addition, the linear range of the biosensor prepared by the modified GOD could extend to 45 mM, while they were about 20 mM for the biosensors based on the wild type yeast-derived enzyme and the commercial enzyme.  相似文献   

17.
Biosensors     
Two decades of research into biosensors has been accelerated recently by the commercial potential offered by biotechnology. New developments in biosensor technology in which a biologically sensitive material is immobilized in intimate contact with a suitable potentiometric, amperometric, optical or other transducer are described. It is expected that some of these devices will be commercialized in 1984.  相似文献   

18.
Fluorescence resonance energy transfer (FRET) with fluorescent proteins is a powerful method for detection of protein-protein interactions, enzyme activities and small molecules in the intracellular milieu. Aided by a new violet-excitable yellow-fluorescing variant of Aequorea victoria GFP, we developed dual FRET-based caspase-3 biosensors. Owing to their distinct excitation profiles, each FRET biosensor can be ratiometrically imaged in the presence of the other.  相似文献   

19.
20.
One of the challenges of modern biology and medicine is to visualize biomolecules in their natural environment, in real-time and in a non-invasive fashion, so as to gain insight into their physiological behavior and highlight alterations in pathological settings, which will enable to devise appropriate therapeutic strategies. Fluorescent biosensors constitute a class of imaging agents which have provided major insights into the function and regulation of enzymes in their cellular context. GFP-based reporters and genetically-encoded FRET biosensors, have been successfully applied to study protein kinases in living cells with high spatial and temporal resolution. In parallel, combined efforts in fluorescence chemistry and in chemical biology have enabled the design of non-genetic, polypeptide biosensors coupled to small synthetic fluorescent probes, which have been applied to monitor protein kinase activities in vitro and in more complex biological samples, with an equally successful outcome. From a biomedical perspective, fluorescent biosensor technology is well suited to development of diagnostic approaches, for monitoring disease progression and for evaluating response to therapeutics. Moreover it constitutes an attractive technology for drug discovery programs, for high content, high throughput screening assays, to assess the potency of new hits and optimize lead compounds, whilst also serving to characterize drugs developed through rational design. This review describes the utility and versatility of fluorescence biosensor technology to probe protein kinases with a specific focus on CDK/cyclin biosensors we have developed to probe abundance, activity and conformation. This article is part of a Special Issue entitled: Inhibitors of Protein Kinases (2012).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号