首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A heterologous direct competitive enzyme-linked immunosorbent assay (ELISA) for parathion residue determination is described based on a monoclonal antibody and a new competitor. The effects of several physicochemical factors, such as methanol concentration, ionic strength, pH value, and sample matrix, on the performance of the ELISA were optimized for the sake of obtaining a satisfactory assay sensitivity. Results showed that when the assay medium was in the optimized condition (phosphate buffer solution [PBS] containing 10% [v/v] methanol and 0.2 mol/L NaCl at a pH value of 5.0), the sensitivity (estimated as the IC50 value) and the limit of detection (LOD, estimated as the IC10 value) were 1.19 and 0.08 ng/ml, respectively. The precision investigation indicated that the intraassay precision values all were below 10% and that the interassay precision values ranged from 4.89 to 19.12%. In addition, the developed ELISA showed a good linear correlation (r2 = 0.9962) to gas chromatography within the analyte’s concentration range of 0.1 to 16 ng/ml. When applied to the fortified samples (parathion adding level: 5-15 μg/kg), the developed ELISA presented mean recoveries of 127.46, 122.52, 91.92, 124.01, 129.72, 99.37, and 87.17% for tomato, cucumber, banana, apple, orange, pear, and sugarcane, respectively. Results indicated that the established ELISA is a potential tool for parathion residue determination.  相似文献   

2.
A convenient, specific, and highly sensitive electrochemical immunosensor based on an indirect competitive assay format was developed for the determination of ochratoxin A (OTA), a common toxic contaminant in various kinds of agricultural products. The sensing substrate was prepared using a gold electrode modified with a self-assembled monolayer of 1,6-hexanedithiol that mediated the assembly of a gold colloid layer, which could enhance the surface loading of OTA-ovalbumin conjugate and improve the sensitivity in electrochemical readouts. After competition of the limited anti-OTA mouse monoclonal antibody between immobilized hapten and OTA analyte in sample solution, alkaline phosphatase (ALP)-labeled horse anti-mouse immunoglobulin G (IgG) antibody was selectively bound onto the surface of the electrode, affording an indicator for OTA concentration in the sample. Electrochemical response arising from the oxidation of enzymatic product of 1-naphthyl phosphate was observed to be inversely proportional to OTA concentration in the range from 10 pg/ml to 100 ng/ml with a detection limit as low as 8.2 pg/ml. Furthermore, a negligible matrix effect and good recoveries were obtained in the determination of corn samples, evidencing the feasibility of the proposed method for accurate determination of OTA in corn samples.  相似文献   

3.
A Surface Plasmon Resonance Imaging (SPRI) sensor based on bromelain or chymopapain or ficin has been developed for specific cystatin determination. Cystatin was captured from a solution by immobilized bromelain or chymopapain or ficin due to the formation of an enzyme-inhibitor complex on the biosensor surface. The influence of bromelain, chymopapain or ficin concentration, as well as the pH of the interaction on the SPRI signal, was investigated and optimized. Sensor dynamic response range is between 0-0.6 μg/ml and the detection limit is equal to 0.1 μg/ml. In order to demonstrate the sensor potential, cystatin was determined in blood plasma, urine and saliva, showing good agreement with the data reported in the literature.  相似文献   

4.
Our interests are in the development of immunoassay-based fast scanning methods for persistent organic pollutants. To develop the immunoassay method of polybrominated diphenyl ether (PBDE), a model compound of PBDE, 2,3′,4,5′,6-pentabromodiphenylether (BDE-121), has been chosen to develop its antibody and the competitive indirect enzyme-linked immunosorbent assay (ELISA) is developed. The hapten of BDE-121 containing reactive carboxylic acid was synthesized and conjugated to carrier proteins (bovine serum albumin [BSA] and ovalbumin [OVA]). Anti-BDE-121 polyclonal antibody was then developed in rabbits as a result of immunization with the BDE-121–BSA conjugate. The optimal amount of coating antigen BDE-121–OVA conjugate and the dilution of antiserum needed in the ELISA were determined with the checkerboard method, and the effects of the properties of PBST (phosphate-buffered saline and Tween 20) buffer (pH and salt concentration) and chemical solvent (types and concentrations) on the ELISA were investigated to achieve a rapid robust assay with high sensitivity. Under the optimized conditions, the developed indirect ELISA shows a linear detection range from 1.74 to 84.1 ng/ml, with an IC50 value of 8.07 ng/ml and a detection limit of 0.644 ng/ml. In total, 11 kinds of compounds were tested for calculating the cross-reactivity, which was less than 8% for nearly all of them. Real samples were analyzed by the proposed immunoassay and gas chromatography/mass spectrometry (GC/MS).  相似文献   

5.
Using a newly developed fluorescent nanoparticle (NP) that gives rise to a high-intensity and stable fluorescent light, a sensitive antibody (Ab) microarray assay system has been developed for specific detection of bioterrorism agents, as exemplified by ricin, cholera toxin (CT), and staphylococcal enterotoxin B (SEB). The Ab microarray uses a sandwich format that consists of capture Abs, analytes (toxins), biotinylated detection Abs, and avidin-conjugated NP. In all three cases, polyclonal Abs (pAbs) displayed superiority over monoclonal antibodies (mAbs) in capturing toxins on microarray slides even when the pAbs and mAbs had similar affinity as determined by enzyme-linked immunosorbent assay (ELISA). The detection system was successfully used to detect toxins spiked in milk, apple cider, and blood samples. We were able to detect ricin at 100 pg/ml in buffer and at 1 ng/ml in spiked apple cider or milk, whereas CT and SEB were detected at 10 pg/ml in buffer and 100 pg/ml in spiked apple cider or milk. High specificities were also demonstrated in the detection of mixed toxin samples with similar sensitivities. The matrix effect of blood samples on the detection of mixed toxins seems to be minimal when the toxin concentration is at or above 100 ng/ml. The current study highlights the significant role of pAb and NP in increasing selectivity and sensitivity of toxin detection in a microarray format.  相似文献   

6.
An optical biosensor based on glutamate dehydrogenase (GLDH) immobilized in a chitosan film for the determination of ammonium in water samples is described. The biosensor film was deposited on a glass slide via a spin-coating method. The ammonium was measured based on β-nicotinamide adenine dinucleotide (NADH) oxidation in the presence of α-ketoglutaric acid at a wavelength of 340 nm. The biosensor showed optimum activity at pH 8. The optimum chitosan concentrations and enzyme loading were found to be at 2% (w/v) and 0.08 mg, respectively. Optimum concentrations of NADH and α-ketoglutaric acid both were obtained at 0.15 mM. A linear response of the biosensor was obtained in the ammonium concentration range of 0.005 to 0.5 mM with a detection limit of 0.005 mM. The reproducibility of the biosensor was good, with an observed relative standard deviation of 5.9% (n = 8). The biosensor was found to be stable for at least 1 month when stored dry at 4 °C.  相似文献   

7.
利用载色体chromatophore上的F0F1-ATPase分子马达生物传感器,建立了应用在食品检测中快速检测方法。首先从嗜热菌中提取载色体后,标记荧光探针F-DHPE,合成生物素化单增李氏菌prfA探针,在已标记F-DHPE的载色体ATP合酶的ε亚基上连接ε亚基抗体-生物素-链霉亲和素-生物素-prfA探针,将待测单核细胞增生李斯特菌标准菌株和阴性对照分别与此生物传感器结合,通过环境H+量测定ATP产生量,进而对单核细胞增生李斯特菌DNA进行检测。结果表明,chro prfA(连接在载色体chro上的prfA探针)的浓度在0.052 mg/mL,单核细胞增生李斯特菌DNA浓度在40 ng/mL为最适检测条件。通过传统检测方法及PCR检测方法对照,本方法具有良好的检测符合性。  相似文献   

8.
A sensitive and simple electrochemical immunosensor based on enzymatic silver deposition amplification was constructed for the detection of aflatoxin B1 (AFB1) in rice. The immunosensor was based on an indirect competitive format between free AFB1 and aflatoxin B1-bovine serum albumin (AFB1-BSA) conjugate immobilized on the electrode surface for binding to a fixed amount of anti-AFB1 antibody. Then the alkaline phosphatase (ALP)-labeled anti-mouse immunoglobulin G (IgG) secondary antibody was bound to the electrode surface through reaction with primary antibody. Finally, ALP catalyzed the substrate, ascorbic acid 2-phosphate, into ascorbic acid that reduced silver ions in solution to metal silver deposited onto the electrode surface. Linear sweep voltammetry was carried out to quantify the metal silver, which indirectly reflected the amount of the analyte. The experimental parameters, such as the dilution ratio of antibody and the concentration of AFB1-BSA conjugate, have been evaluated and optimized. At the optimal conditions, the working range of the electrochemical immunosensor was from 0.1 to 10 ng/ml with a detection limit of 0.06 ng/ml. Good recoveries were obtained for the detection of spiked rice samples. So, the proposed method in this article could find a good use for screening AFB1 in real samples.  相似文献   

9.
Microband glucose biosensors were produced by insulating and sectioning through a screen-printed, water-based carbon electrode containing cobalt phthalocyanine redox mediator and glucose oxidase enzyme. Under quiescent conditions at 37 °C, at an operating potential of +0.4 V, they produced an amperometric response to glucose in buffer solutions with a sensitivity of 26.4 nA/mM and a linear range of 0.45 to 9.0 mM. An optimal pH value of 8.5 was obtained under these conditions, and a value for activation energy of 40.55 kJ mol−1 was calculated. In culture medium (pH 7.3), a sensitivity of 13 nA/mM was obtained and the response was linear up to 5 mM with a detection limit of 0.5 mM. The working concentration was up to 20 mM glucose with a precision of 11.3% for replicate biosensors (n = 4). The microband biosensors were applied to determine end-point glucose concentrations in culture medium by monitoring steady-state current responses 400 s after transfer of the biosensors into different sample solutions. In conjunction with cultures of HepG2 (human Caucasian hepatocyte carcinoma) cells, current responses obtained in 24-h supernatants showed an inverse correlation (R2 = 0.98) with cell number, indicating that the biosensors were applicable for monitoring glucose metabolism by cells and of quantifying cell number. Glucose concentrations determined using the biosensor assay were in good agreement, for concentrations up to 20 mM, with those determined spectrophotometrically (R2 = 0.99). This method of end-point glucose determination was used to provide an estimated rate of glucose uptake for HepG2 cells of 7.9 nmol/(106 cells min) based on a 24-h period in culture.  相似文献   

10.
We report a method to build ultrasensitive carbon nanotube-based biosensors using immune binding reaction. Here carbon nanotube-field effect transistors (CNT-FETs) were functionalized with antibody-binding fragments as a receptor, and the binding event of target immunoglobulin G (IgG) onto the fragments was detected by monitoring the gating effect caused by the charges of the target IgG. Because the biosensors were used in buffer solution, it was crucial to use small-size receptors so that the charged target IgG could approach the CNT surface within the Debye length distance to give a large gating effect. The results show that CNT-FET biosensors using whole antibody had very low sensitivity (detection limit ∼1000 ng/ml), whereas those based on small Fab fragments could detect 1 pg/ml (∼7 fM level). Moreover, our Fab-modified CNT-FET could successfully block the nontarget proteins and could selectively detect the target protein in an environment similar to that of human serum electrolyte. Significantly, this strategy can be applied to general antibody-based detection schemes, and it should enable the production of label-free ultrasensitive electronic biosensors to detect clinically important biomarkers for disease diagnosis.  相似文献   

11.
A biosensor platform based on polyamic acid (PAA) is reported for oriented immobilization of biomolecules. PAA, a functionalized conducting polymer substrate that provides electrochemical detection and control of biospecific binding, was used to covalently attach biomolecules, resulting in a significant improvement in the detection sensitivity. The biosensor sensing elements comprise a layer of PAA antibody (or antigen) composite self-assembled onto gold (Au) electrode via N-hydroxysuccinimide (NHS) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDC) linking. The modified PAA was characterized by Fourier transform infrared (FTIR), (1)H nuclear magnetic resonance (NMR), and electrochemical techniques. Cyclic voltammetry and impedance spectroscopy experiments conducted on electrodeposited PAA on Au electrode using ferricyanide produced a measurable decrease in the diffusion coefficient compared with the bare electrode, indicating some retardation of electron transfer within the bulk material of the PAA. Thereafter, the modified PAA surface was used to immobilize antibodies and then to detect inducible nitric oxide synthase and mouse immunoglobulin G (IgG) using enzyme-linked immunosorbent assay (ELISA), surface plasmon resonance (SPR), and amperometric techniques. ELISA results indicated a significant amplified signal by the modified PAA, whereas the SPR and amperometric biosensors produced significant responses as the concentration of the antigen was increased. Detection limits of 3.1×10(-3)ng/ml and 2.7×10(-1)ng/ml were obtained for SPR and amperometric biosensors, respectively.  相似文献   

12.
The present study investigated the diagnostic value of an ELISA for the detection of Clonorchis sinensis antigen in the feces of experimentally infected rats. A mouse polyclonal IgG antibody against adult C. sinensis crude antigen (CsAg) was used to capture the C. sinensis coproantigen. The detection limit for pure CsAg was 20 ng/ml in sample buffer and 40 ng/ml in uninfected fecal extract. The test was evaluated using a follow-up of five groups of rats experimentally infected with 100, 50, 10, 5 and 1 metacercariae of C. sinensis and an uninfected control group. Coproantigen was detected in all infected groups of rats from 2 weeks of infection, whereas fecal eggs were not observed until 3 weeks of infection. As the infection period progressed, the fecal CsAg concentration increased in all groups of infected rats, even those infected with a single metacercaria. The fecal CsAg concentration was correlated positively with fecal egg counts and worm burden. This coproantigen capture ELISA is highly sensitive for the detection of CsAg in rat feces, and with further development, should be useful for mass screening of human subjects in clonorchiasis-endemic areas.  相似文献   

13.
In this work, a multiwalled carbon nanotube (MWCNT)–Nafion–cysteamine (CA) modified tyrosinase biosensor brings a new and original perspective to biosensor technology intended for the development of dopamine determination. Dopamine measurements were done at 0.2 V with the amperometric method by the developed biosensor system. In addition, in this study dopamine determination was carried out by using the differential pulse voltammetry method between potentials of 0.4 and −0.15 V. In the optimization studies of the biosensor, some parameters such as optimal pH, optimal temperature, optimal enzyme amount, and effect of MWCNT concentration were investigated. Afterward, in the characterization studies, some parameters such as linearity and reproducibility were determined. In the reproducibility experiment, an average value of 1.026 μM, a standard deviation of ±0.03975, and a coefficient of variation of 3.8% were determined for a 1-μM dopamine concentration (n = 15). Determination of dopamine was carried out in drug samples by the developed biosensor.  相似文献   

14.
Implementation of the on-chip immunoassay for α-fetoprotein (AFP)-L3% was achieved using a fully automated microfluidic instrument platform that will prepare the chip and run the assay with a total assay time of less than 10 min. Reagent/sample mixing, concentration, and reaction in microfluidic channels occur by the electrokinetic analyte transport assay (EATA) technique, enabling the integration of all assay steps on-chip. The determination of AFP-L3%, a biomarker for hepatocellular carcinoma, was achieved by the presence of Lens culinaris agglutinin in the separation channel, causing separation of the fucosylated isoform, AFP-L3, from the nonfucosylated AFP-L1 by lectin affinity electrophoresis. Laser-induced-fluorescence (LIF) detection was used to quantitate the labeled immunocomplexes. The limit of detection (LOD) was 0.1 ng/ml AFP, and assay precision of less than 2% coefficient of variation (CV) was obtained for quantitation from 24 to 922 ng/ml total AFP in spiked serum samples. Assay precision of less than 3% CV was obtained for AFP-L3% measurements from 8.5 to 81%. Furthermore, good correlation of test results for 68 patient serum samples with a commercially available reference method (LiBASys assay for AFP-L3%) was obtained, with r= 0.981 and slope = 1.03.  相似文献   

15.
Trastuzumab, a humanized monoclonal antibody, is used for the treatment of breast cancer patients who overexpress the HER2 receptor. To optimize therapy, pharmacokinetic studies are necessary. The aim of this study was to develop an enzyme-linked immunosorbent assay (ELISA) for trastuzumab to support these pharmacokinetic studies. For this immunoassay, we raised anti-idiotype antibodies in rabbits. After purification of the rabbit material, the anti-idiotype antibodies are used as capturing antibodies on the ELISA plate. After trastuzumab has bound to the catcher antibody, a sandwich ELISA procedure is followed whereby biotinylated anti-idiotype antibodies can bind to trastuzumab. Detection is performed by streptavidin-polyHRP (poly-horseradish peroxidase) conjugate and (3,5,3′,5′)-tetramethylbenzidine (TMB) substrate. The reaction is stopped using sulfuric acid, and the absorbance is measured at 450 nm. The calibration range of the assay is 0.039 to 5 ng/ml in well. Because samples are analyzed in multiple dilutions, the validated range corresponds to 1.6 to 1600 ng/ml in undiluted serum. Samples above the upper limit of quantification (ULOQ) can be diluted before transfer to the assay plates. Validation results demonstrate that trastuzumab can be accurately and precisely quantified in human serum and plasma. The assay is now used to support pharmacokinetic studies with trastuzumab in human serum and plasma.  相似文献   

16.
A fragment of the human β-chain of hemoglobin (HEM), hHEMβ111-146, was shown to have broad antimicrobial properties. The 3.9-kDa peptide was postulated to occur in high concentrations in placenta tissue. We established a reliable method to quantify hHEMβ111-146 in placenta tissue. Our methodology consists of a tissue extraction step (step 1), a chromatographic enrichment step (step 2), and a final quantification step (step 3) by enzyme-linked immunosorbent assay (ELISA). The specificity of the ELISA reaction was confirmed by parallel analysis of the samples via Western blot (step 4). The ELISA measured the absorbance of a tetramethylbenzidine substrate at 450 nm. It showed no cross-reactivity with the corresponding γ- and α-HEM regions and low cross-reactivity with the β-HEM region and full-length HEM. The sample preparation procedure enabled a prepurification of hHEMβ111-146, completely eliminating cross-reactive proteins and HEM peptides. The linear range of detection in step 3 was 20-200 ng/well (200-2000 μg/L) with a limit of quantification of 23 ng/well (230 μg/L) and a limit of detection of 7 ng/well (70 μg/L). The assay was characterized by good linearity (r> 0.99), intraday precision (coefficient of variation [CV] = 2.2-8.3%), interday precision (CV = 1.8-9.1%), and accuracy (76-109%). The mean recovery of the ELISA was determined to be 97%, and the overall recovery during steps 1-3 was found to be 40.3 ± 2.5%. We measured concentrations from 0.28 to 0.74 mg/g placenta tissue of the hHEMβ111-146 in different placenta samples with an average concentration of 0.57 mg/g. This abundant concentration supports an important physiological role of hHEMβ111-146 in the placenta infective barrier.  相似文献   

17.
目的:建立高灵敏度的阿特拉津酶联免疫吸附检测法。方法:将间接竞争ELISA进行条件优化以提高检测灵敏度,包括包被抗原与一抗的最佳工作浓度筛选、选择一抗的最佳稀释度对包被抗原进行细化筛选、不同有机溶剂对竞争结合反应的影响、酶标二抗稀释度筛选等。用建立的酶联免疫检测法检测实际样品,再与高效液相色谱法(HPLC)检测进行比较。结果:利用优化后条件建立了阿特拉津间接竞争ELISA检测曲线,标准曲线的相关系数R2=0.9958,相关性较好。另由此标准曲线可得LOD (最低检出限)为1.972 ng/ml。用于检测实际样品,回收率在80%-120%之间。当添加样品浓度为(0~6) ng/ml时,该法的检测灵敏度高于HPLC。结论:新建立的阿特拉津ELISA特异性好、精密度高,可代替大型仪器用于阿特拉津实际样品检测。  相似文献   

18.
Biological monitoring of low level exposure to pollutants is a very challenging analytical activity, and the quality of results is difficult to assess, especially when a certified reference material is unavailable. The aim of this work was to evaluate the reliability of the assays used to measure urinary benzene (Benz-U) and S-phenylmercapturic acid (SPMA), by applying an internal quality control protocol. Urine spot samples from 705 subjects who were either members of the general urban population, gasoline station attendants, or refinery plant workers were assayed for Benz-U and SPMA, using GC/MS and LC/MS/MS, with quantification limits of 15 ng/L and 0.10 μg/L. The median Benz-U concentration was 263 ng/L (60-2789 ng/L, 5th-95th percentile), and the median SPMA concentration was 0.19 μg/L (<0.1-2.5 μg/L, 5th-95th percentile). Linearity of both assays was good, but a less-than-proportional response was found for SPMA concentrations below 1 μg/L. Between-run precision and accuracy for Benz-U concentration determination were assessed using quality controls at 120 ng/L and 1000 ng/L and were 10.3% and 4.8%, and 104.8% and 98.9%, respectively; while the precision and accuracy for SPMA concentration determination at 0.3 μg/L, 2.5 μg/L, and 20 μg/L were 40.3%, 6.2%, and 6.2%, and 48.3%, 96.3%, and 98.8%, respectively. Precision, estimated using duplicates of unknown samples, was 13.4% for Benz-U and 26.5% for SPMA analyses. Control charts for the means of the slope of the linear calibration curve of Benz-U showed good stability of the means over a five-year period. For SPMA, a two-laboratory comparison revealed acceptable agreement between ln-transformed data pairs, with a slope of the linear regression of 0.863 (confidence interval 0.774-0.952), null intercept, and a Pearson's r value of 0.844. Reliable results were obtained for Benz-U analyses over the entire concentration range, and for high and medium SPMA levels. However, the determination of SPMA concentrations at levels close to the limit of quantification was less reliable.  相似文献   

19.
Erythromycin (ERY), clarithromycin (CLA), roxithromycin (ROX), and azithromycin (AZI) are macrolide antibiotics widely used in livestock and human medicine. Therefore, they are frequently found as pollutants in environmental water. A method based on indirect competitive enzyme-linked immunosorbent assay (ELISA) for group determination of these macrolides in foodstuffs, human biofluids, and water was developed. Carboxymethyloxime of clarithromycin (CMO–CLA) was synthesized and conjugated to bovine serum albumin (BSA) and gelatin to prepare immunogen and coating antigen with advantageous presentation of target epitopes, l-cladinose and d-desosamine, common for these analytes. Antibodies generated in rabbits were capable of recognizing ERY, CLA, and ROX as a group (100–150%), and AZI (12%) and did not cross-react with ERY degradants, which lack antibiotic activity. Assay displayed sensitivity of determination of 14-membered macrolides (IC50 = 0.13–0.2 ng/ml) and low limit of detection (LOD) that was achieved at 0.02 to 0.03 ng/ml. It allowed performing analysis of milk, muscle, eggs, bovine serum, water, human serum and urine, and avoiding matrix effect without special pretreatment using simple dilution with assay buffer. For 15-membered macrolide AZI, the corresponding characteristics were IC50 = 1.6 ng/ml and LOD = 0.14 ng/ml. The recoveries of veterinary and human medicine macrolides from corresponding matrices were validated and found to be satisfactory.  相似文献   

20.
Adducts of benzo[a]pyrene-diolepoxide (BPDE) with blood nucleophiles have been used as biomarkers of exposure to polycyclic aromatic hydrocarbons (PAHs). The most popular such assay is a competitive enzyme-linked immunosorbent assay (ELISA) that employs monoclonal antibody 8E11 to detect benzo[a]pyrene tetrols following hydrolysis of BPDE adducts from lymphocyte DNA or human serum albumin (HSA). Here we used 8E11 as the capture antibody in a sandwich ELISA to detect BPDE-HSA adducts directly in 1-mg samples of HSA or 20 μl of serum/plasma. The assay employs an anti-HSA antibody for detection, and this is amplified by an avidin/biotinylated horseradish peroxidase complex. The sandwich ELISA has advantages of specificity and simplicity and is approximately 10 times more sensitive than the competitive ELISA. To validate the assay, HSA samples were assayed from three populations with known high PAH exposures (coke oven workers), medium PAH exposures (steel factory control workers), and low PAH exposures (volunteer subjects) (n = 30). The respective geometric mean levels of BPDE-HSA adducts—67.8, 14.7, and 1.93 ng/mg HSA (1010, 220, and 28.9 fmol BPDE equiv/mg HSA)—were significantly different (P < 0.05). The sandwich ELISA will be useful for screening PAH exposures in large epidemiologic studies and can be extended to other adducts for which capture antibodies are available.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号