首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The concentration of airborne fungal spores and bacteria as related to room temperature, humidity and occupancy levels within a library building in Singapore was determined. Measurement of indoor air quality with respect to microorganisms is of particular importance in tropical environments due to the extensive use of air‐conditioning systems and the potential implications for human health. This study has revealed a number of interesting relationships between the concentrations of fungal spores and bacteria in relation to both environmental and human factors. The levels of fungal spores measured in the indoor environment were approximately fifty times lower than those measured outside, probably because of the lowered humidity caused by air‐conditioning in the indoor environment. The variation in fungal spore concentration in the outdoor environment is likely to be due to the diurnal periodicity of spore release and the response to environmental factors such as light temperature and humidity. The indoor concentration of fungal spores in air was not clearly correlated to concentrations measured in air outside of the library building and remained relatively constant, unaffected by the difference in the numbers of occupants in the library. In contrast, the indoor concentrations of bacteria in air were approximately ten times higher than those measured outdoors, indicating a signficant internal source of bacteria. The elevated levels of indoor bacteria were primarily attributed to the number of library occupants. Increased human shedding of skin cells, ejection of microorganisms and particulates from the respiratory tract, and the transport of bacteria on suspended dust particles from floor surfaces probably accounts for the strong positive correlation between occupancy levels and the concentration of bacteria in internal air.  相似文献   

2.
Indoor environments play important roles in human health. The health hazards posed by polluted indoor environments include allergy, infections and toxicity. The term ‘sick building syndrome’ (SBS) describes causes of building occupants experiencing adverse health effects that appear to be linked to the time spent in a building. Questionnaire-based data were collected from the people who live or work in air-conditioned (A/C) rooms. Responses of the occupants were analyzed to understand the practices contributing to biotic pollution of indoor air-conditioned environments. Our survey revealed some interesting facts about the users of A/C rooms and their practices that may be contributing to the indoor air quality. The allergy complaints and use of anti-allergy medicines were noted commonly among the occupants of government (Govt.) organizations and computer training centers where cleaning of room and A/C filters were not done periodically. Cleaning practices may reduce the complaints.  相似文献   

3.
A thermal comfort field study has been carried out in five cities in the humid subtropical climate zone in China. The survey was performed in naturally ventilated and air-conditioned buildings during the summer season in 2006. There were 229 occupants from 111 buildings who participated in this study and 229 questionnaire responses were collected. Thermal acceptability assessment reveals that the indoor environment in naturally ventilated buildings could not meet the 80% acceptability criteria prescribed by ASHRAE Standard 55, and people tended to feel more comfortable in air-conditioned buildings with the air-conditioned occupants voting with higher acceptability (89%) than the naturally ventilated occupants (58%). The neutral temperatures in naturally ventilated and air-conditioned buildings were 28.3°C and 27.7°C, respectively. The range of accepted temperature in naturally ventilated buildings (25.0∼31.6°C) was wider than that in air-conditioned buildings (25.1∼30.3°C), which suggests that occupants in naturally ventilated buildings seemed to be more tolerant of higher temperatures. Preferred temperatures were 27.9°C and 27.3°C in naturally ventilated and air-conditioned buildings, respectively, both of which were 0.4°C cooler than neutral temperatures. This result suggests that people of hot climates may use words like “slightly cool” to describe their preferred thermal state. The relationship between draught sensation and indoor air velocity at different temperature ranges indicates that indoor air velocity had a significant influence over the occupants’ comfort sensation, and air velocities required by occupants increased with the increasing of operative temperatures. Thus, an effective way of natural ventilation which can create the preferred higher air movement is called for. Finally, the indoor set-point temperature of 26°C or even higher in air-conditioned buildings was confirmed as making people comfortable, which supports the regulation in China that in public and office buildings the set-point temperature of air-conditioning system should not be lower than 26°C.  相似文献   

4.
Buildings with indoor air quality (IAQ) complaints frequently have high airborne concentrations of Penicillium species, while buildings with few IAQ complaints have an indoor air (IDA) fungal ecology similar to outdoor air (ODA), where Cladosporium species is usually the dominant microorganism. These studies compared fungal air profiles, measured continually over 6 h in a documented sick building, in IDA in a room experiencing IAQ problems with fungal profiles measured concurrently in ODA. The dominant species collected at both sites were Penicillium species, Cladosporium species, and Alternaria species. In the IDA, Penicillium species were always the dominant organisms, ranging from 150 to 567 cfu/m3 (89.8–100% of the total fungi). In the ODA, Cladosporium species were dominant in four samples (40.0–70.6%), while Penicillium species were dominant (52.7–79.6%) in two. These data demonstrate that, even though ODA fungal profiles are changing continuously, IDA fungal profiles in “sick” buildings tend to remain unchanged. Received: 6 July 1998 / Accepted: 12 August 1998  相似文献   

5.
Significant media and regulatory attention has been given to hazardous waste sites and to the remediation of such sites to protect nearby building occupants. Soil vapor intrusion (SVI) can be a major factor contributing to increased occupant expo sure to chemicals. However, there are many possible sources of indoor air pollution, thus complicating routine assessments. The intent of this paper is to provide an overview of the state of understanding related to chemical fate in the indoor environment. A generalized model is presented in the form of an ordinary differential equation that includes several terms that are not commonly accounted for in models involving the effects of SVI in indoor air. In addition to soil vapor intrusion several other sources of indoor contamination are described. Typical air exchange rates for residential dwellings are presented. Finally, recent findings related to the sorptive interactions between indoor air pollutants and indoor materials, as well as homogeneous and heterogeneous chemical reactions that can affect indoor air pollutants are described.  相似文献   

6.
Indoor climate and air quality   总被引:2,自引:0,他引:2  
 In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants’ clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ”sick building syndrome”. Received: 27 October 1997 / Accepted 26 November 1997  相似文献   

7.
The fungal concentration and flora in indoor and outdoor air in Yokohama, Japan were analyzed with a Reuter centrifugal air sampler and dichloran 18% glycerol agar (DG18), and compared with the levels assessed with potato dextrose agar (PDA). The number of fungal colony-forming units (CFU) in outdoor air was < 13–2750/m3; Cladosporium spp. predominated, followed by Alternaria spp. and Penicillium spp. The fungal concentration in outdoor air peaked in September. The concentrations of fungi in outdoor air (n = 288) were significantly correlated with the maximum temperature of the day, minimum temperature of the day, average temperature of the day, average velocity of wind of the day, average temperature of the month, average relative humidity of the month and precipitation of the month. In indoor air, the fungal CFU was < 13–3750/m3. Cladosporium spp. predominated, followed by the xerophilic fungi such as the Aspergillus restrictus group, Wallemia sebi, the A. glaucus group, and Penicillium spp. The fungal concentration in indoor air peaked in October. The concentrations of fungi in indoor air (n = 288) were significantly correlated with the indoor temperature, indoor relative humidity and the outdoor climatic factors mentioned above, except for the average velocity of wind of the day. This revised version was published online in June 2006 with corrections to the Cover Date.  相似文献   

8.
Ruga  Luigia  Orlandi  Fabio  Fornaciari  Marco 《Aerobiologia》2021,37(2):363-372

The conservation actions towards artworks holding a common patrimony for the community are of primary importance, but also those related to their "container" as museums, libraries or archives are to consider. Fungal spores and bacteria carried by air flows to the artwork surface can colonize it causing biodeterioration through physical and/or chemical alterations of the materials with the irreversible loss of their value. The quality control of the indoor air surrounding the historic building is essential, as well as for the protection and conservation of the artwork, also for the protection of the health of operators and visitors. The aim of this study was to monitor airborne fungal particles, through volumetric spore traps, for improving the knowledge about the conservation and protection of artworks in the museum environment analysing the principal relationships between indoor environmental conditions and potentially biodeteriogen fungal spore growth. The evidence of no significant relationships between spore concentrations and environmental conditions recorded inside the different expositive rooms testified the regular and correct maintenance of the air conditioning system inside the considered building (National Gallery of Umbria, central Italy). Moreover, in a specific museum room a significant spore concentration decreasing trend was recorded mainly due to a structural modification in the same building.

  相似文献   

9.
In this study an attempt was made to evaluate the qualitative and quantitative fungal burden (load) in five different working environments of South Assam (India) and the possible risks of indoor fungi to employees and stored products. Fungal concentrations in different working environments were studied using a Burkard personal petriplate sampler. The survey was done in five different working environments for one year. A total of 76 fungal types were recorded in the indoor air of South Assam during the survey period. The maximum fungal concentration (5,437.6 ± 145.3 CFU m−3 air) was recorded in the indoor air of medical wards, followed by the paper-processing industry (3,871.7 ± 93.4 CFU m−3 air). However the lowest concentration was observed in the indoor air of a bakery (1,796.8 ± 54.4 CFU m−3 air). The most dominant fungal genera were Aspergillus (34.2%) followed by Penicillium (17.8%), Geotrichum (7.0%) and the most dominant fungal species were Aspergillus fumigatus (2,650.4 CFU m−3 air) followed by Aspergillus flavus (1,388.2 CFU m−3 air), Geotrichum candidum (1,280.3 CFU m−3 air), Aspergillus niger (783.3 CFU m−3 air), and Penicillium aurantiovirens (774.0 CFU m−3 air). The fungal species viz., Aspergillus fumigatus, Penicillium aurantiovirens, Aspergillus flavus, Aspergillus niger, Geotrichum candidum, and Penicillium thomii, which were recorded well above threshold levels, may lead to adverse health hazards to indoor workers. Setting occupational exposure limits for indoor fungal spores as reference values is obligatory for prevention and control of adverse effects of indoor fungal exposure.  相似文献   

10.
There is growing concern about the adverse effects of fungal bioaerosols on the occupants of damp dwellings. Based on an extensive analysis of previously published data and on experiments carried out within this study, critical limits for the growth of the indoor fungi Eurotium herbariorum, Aspergillus versicolor, and Stachybotrys chartarum were mathematically described in terms of growth limit curves (isopleths) which define the minimum combination of temperature (T) and relative humidity (RH) at which growth will occur. Each growth limit curve was generated from a series of data points on a T-RH plot and mathematically fitted by using a third-order polynomial equation of the form RH = a3T3 + a2T2 + a1T + a0. This fungal growth prediction model was incorporated within the ESP-r (Environmental Systems Performance [r stands for “research”]) computer-based program for transient simulation of the energy and environmental performance of buildings. For any specified location, the ESP-r system is able to predict the time series evolution of local surface temperature and relative humidity, taking explicit account of constructional moisture flow, moisture generation sources, and air movement. This allows the predicted local conditions to be superimposed directly onto fungal growth curves. The concentration of plotted points relative to the curves allows an assessment of the risk of fungal growth. The system’s predictive capability was tested via laboratory experiments and by comparison with monitored data from a fungus-contaminated house.  相似文献   

11.
There is growing concern about the adverse effects of fungal bioaerosols on the occupants of damp dwellings. Based on an extensive analysis of previously published data and on experiments carried out within this study, critical limits for the growth of the indoor fungi Eurotium herbariorum, Aspergillus versicolor, and Stachybotrys chartarum were mathematically described in terms of growth limit curves (isopleths) which define the minimum combination of temperature (T) and relative humidity (RH) at which growth will occur. Each growth limit curve was generated from a series of data points on a T-RH plot and mathematically fitted by using a third-order polynomial equation of the form RH = a(3)T(3) + a(2)T(2) + a(1)T + a(0). This fungal growth prediction model was incorporated within the ESP-r (Environmental Systems Performance [r stands for "research"]) computer-based program for transient simulation of the energy and environmental performance of buildings. For any specified location, the ESP-r system is able to predict the time series evolution of local surface temperature and relative humidity, taking explicit account of constructional moisture flow, moisture generation sources, and air movement. This allows the predicted local conditions to be superimposed directly onto fungal growth curves. The concentration of plotted points relative to the curves allows an assessment of the risk of fungal growth. The system's predictive capability was tested via laboratory experiments and by comparison with monitored data from a fungus-contaminated house.  相似文献   

12.
Buildings with poor indoor air quality (IAQ) frequently have many areas with surface fungal contamination. Studies have demonstrated that certain fungal genera (e.g., Cladosporium, Penicillium, and Stachybotrys) are able to grow on building materials such as wallpaper, drywall, and ceiling tiles, particularly after water damage has occurred. Due to the increasing awareness of sick building syndrome (SBS), it has become essential to identify building materials that prevent the interior growth of fungi. The objective of this study was to identify building materials that would not support the growth of certain fungal genera, regardless of whether an external food source was made available. The growth of three fungal genera (Cladosporium, Penicillium, and Stachybotrys) was evaluated on cellulose-containing ceiling tile (CCT) and inorganic ceiling tile (ICT). Both types of ceiling tile were exposed to environmental conditions which can occur inside a building. Our results show that ICT did not support the growth of these three fungal genera while CCT did. Our data demonstrate that ICT could serve as an ideal replacement for CCT. This revised version was published online in June 2006 with corrections to the Cover Date.  相似文献   

13.
Human occupants are an important source of microbes in indoor environments. In this study, we used DNA sequencing of filter samples to assess the fungal and bacterial composition of air in an environmental chamber under different levels of occupancy, activity, and exposed or covered carpeting. In this office-like, mechanically ventilated environment, results showed a strong influence of outdoor-derived particles, with the indoor microbial composition tracking that of outdoor air for the 2-hour sampling periods. The number of occupants and their activity played a significant but smaller role influencing the composition of indoor bioaerosols. Human-associated taxa were observed but were not particularly abundant, except in the case of one fungus that appeared to be transported into the chamber on the clothing of a study participant. Overall, this study revealed a smaller signature of human body-associated taxa than had been expected based on recent studies of indoor microbiomes, suggesting that occupants may not exert a strong influence on bioaerosol microbial composition in a space that, like many offices, is well ventilated with air that is moderately filtered and moderately occupied.  相似文献   

14.
There is a growing interest in indoor air quality for a better quality environment both at home and at work because many people spend at least 80% of their time indoors. The aim of our study was to evaluate the indoor concentration of airborne bacteria and fungi in a University auditorium, in an office of public buildings and in an apartment in the presence and in absence of building's occupants, building materials and furnishings. The concentrations of airborne bacteria and fungi were determined using a Surface Air System (SAS). In presence of people and furnishings the average air concentrations of bacteria (University auditorium: 925-1225 CFU m(-3); office: 493 CFU m(-3); apartment: 92-182 CFU m(-3)) were higher than in absence (respectively: 190-315 CFU m(-3); 126 CFU m(-3); 66-80 CFU m(-3)). The average air concentrations fungal were higher in presence of people and furnishings (University auditorium: 1256-1769 CFU m(-3); office: 858 CFU m(-3); apartment: 147-297 CFU m(-3)) than in absence (respectively: 301-431 CFU m(-3); 224 CFU m(-3); 102-132 CFU m(-3)). The obtained data can be considered as a step to identify acceptable levels for bioaerosols in common indoor environments.  相似文献   

15.
Exposure to airborne microorganisms in indoor environments may result in infectious disease or elicit an allergic or irritant response. Air handling system components contaminated by fungi have been implicated in the dispersal of spores into the indoor environment, thereby serving as a route of exposure to occupants. This study was conducted to provide quantitative data on the dispersal of spores from fungal colonies growing on three types of duct material. Galvanized metal, rigid fibrous glass ductboard, and fiberglass duct liner were soiled and contaminated with a known concentration of Penicillium chrysogenum spores. The duct materials were incubated in humidity chambers to provide a matrix of growing, sporulating fungal colonies at a contamination level of 109 colony forming units (CFU) per duct section, consistent for all materials. For each experiment a contaminated duct section was inserted into the air handling system of an experimental room, and the air handling system was operated for three 5-minute cycles with an air flow of 4.2 m3 min–1. The duct air velocity was approximately 2.8 m sec–1. The airborne concentration of culturable P. chrysogenum spores (CFU m–3), total P. chrysogenum spores (spores m–3), and total P. chrysogenum-sized particles (particles m–3) were measured in the room using Andersen single-stage impactor samplers, Burkard slide impactor samplers, and an aerodynamic particle sizer, respectively. The highest airborne concentrations (104 CFU m–3; 105 spores m–3; 104 particles m–3) were measured during the first operating cycle of the air handling system for all duct materials with decreasing airborne concentrations measured during the second and third cycles. There was no significant difference in spore dispersal from the three contaminated duct materials. These data demonstrate the potential exposure for building occupants to high concentrations of spores dispersed from fungal colonies on air handling system duct materials during normal operation of the system.  相似文献   

16.
Indoor and outdoor airborne fungal propagule concentrations in Mexico City   总被引:7,自引:0,他引:7  
Thirty homes of asthmatic adults located in Mexico City were examined to determine the predominant culturable fungi and the changes in their airborne concentrations. Fungi were cultured and identified microscopically from air samples collected in naturally ventilated homes, during both wet (July–August) and cool dry (November–December) seasons, and from settled dust from the same homes. Airborne dust from indoor yielded 99–4950 cfu m−3, and settled dust 102–106 cfu g−1 on DG18 agar. The indoor geometric mean concentration of airborne fungi during the cool dry season was 460 cfu m−3 while in the wet season it was 141 cfu m−3. Similarly, numbers of airborne fungal propagules out of doors decreased 60% between the dry and wet season. In general, the total fungal concentrations in indoor air were less than 103 cfu m−3 and a large proportion of them was collected in Stage-2 of the Andersen sampler. Moreover, the ratio between indoor and outdoor concentrations was <3:1. Five of the 30 sampled homes yielded >500 cfu m−3 of one genus, with up to 1493Cladosporium cfu m−3 or 2549Penicillium cfu m−3. Also, these two genera were predominant in both airborne and settled dust, and their concentrations were greater indoors than out, indicating a possible indoor source of fungal propagules. The predominant species wereCladosporium herbarum, Penicillium aurantiogriseum andP. chrysogenum. These results suggest that exposure to large concentrations of fungi occurs indoors and is associated with both seasons of the year and with particular home characteristics.  相似文献   

17.
The indoor microbiome is a complex system that is thought to depend on dispersal from the outdoor biome and the occupants'' microbiome combined with selective pressures imposed by the occupants'' behaviors and the building itself. We set out to determine the pattern of fungal diversity and composition in indoor air on a local scale and to identify processes behind that pattern. We surveyed airborne fungal assemblages within 1-month time periods at two seasons, with high replication, indoors and outdoors, within and across standardized residences at a university housing facility. Fungal assemblages indoors were diverse and strongly determined by dispersal from outdoors, and no fungal taxa were found as indicators of indoor air. There was a seasonal effect on the fungi found in both indoor and outdoor air, and quantitatively more fungal biomass was detected outdoors than indoors. A strong signal of isolation by distance existed in both outdoor and indoor airborne fungal assemblages, despite the small geographic scale in which this study was undertaken (<500 m). Moreover, room and occupant behavior had no detectable effect on the fungi found in indoor air. These results show that at the local level, outdoor air fungi dominate the patterning of indoor air. More broadly, they provide additional support for the growing evidence that dispersal limitation, even on small geographic scales, is a key process in structuring the often-observed distance–decay biogeographic pattern in microbial communities.  相似文献   

18.
Many studies have focused on the sources of fungal contamination in indoor spaces. Pathogenic fungi have been detected in the potting mix of indoor plants; however, it is unclear if plants in indoor work spaces make qualitative or quantitative contributions to the aeromycota within buildings. The current work represents a field study to determine, under realistic office conditions, whether indoor plants make a contribution to the airborne aeromycota. Fifty-five offices, within two buildings in Sydney’s central business district, were studied over two seasonal periods: autumn and spring. We found that indoor plant presence made no significant difference to either indoor mould spore counts or their species composition. No seasonal differences occurred between autumn and spring samples. Indoor spore loads were significantly lower than outdoor levels, demonstrating the efficiency of the heating, ventilation and air conditioning systems in the buildings sampled. Neither the number of plants nor the species of plant used had an influence on spore loads; however, variations of those two variables offer potential for further studies. We conclude that conservative numbers of indoor plants make no substantial contribution to building occupants exposure to fungi.  相似文献   

19.
Secondary air filters in the air-handling units on four floors of a multi-story office building with a history of fungal colonization of insulation within the air distribution system were examined for the presence of growing fungi and production of volatile organic compounds. Fungal mycelium and conidia of Cladosporium and Penicillium spp. were observed on insulation from all floors and both sides of the air filters from one floor. Lower concentrations of volatile organics were released from air filter medium colonized with fungi as compared with noncolonized filter medium. However, the volatiles from the colonized filter medium included fungal metabolites such as acetone and a carbonyl sulfide-like compound that were not released from noncolonized filter medium. The growth of fungi in air distribution systems may affect the content of volatile organics in indoor air. Received: 2 June 1997 / Accepted: 13 June 1997  相似文献   

20.
Jagjit Singh 《Aerobiologia》1996,12(2):121-127
In this special report, the possible causes of indoor air pollution and its impact on the health, comfort and productivity of the building occupant are discussed. The causes and symptoms of sick building syndrome, allergy and environmental illnesses and building related illnesses are discussed in the context of building environments. The remediation and prevention measures examine the solution to the problems caused by indoor air pollution in buildings.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号