首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
We present a rare case of tachycardiomyopathy in a 4-year-old girl. The child had incessant atrial tachycardia (AT) and refractory heart failure. Right atrial appendage (RAA) was localised as the source of the ectopic tachycardia. The child underwent successful radiofrequency ablation (RFA) using 3-D electroanatomical mapping. Fluoroscopy was used sparingly only to rule out underlying anomalies. The left ventricular functions returned to normal by one month after the procedure. RAA AT is rare in very young children and usually necessitates surgical appendectomies. RFA is a challenge in such age groups and there are very few published literature on RAA AT in very young children.  相似文献   

2.
An 83-year-old man underwent electrophysiological testing for focal atrial tachycardia (AT) exhibiting narrow P waves with negative deflections in the inferior leads. Catheter ablation at the cavo-tricuspid isthmus (CTI) successfully eliminated the AT. The propagation map during AT and pacing study from the successful ablation site demonstrated that the atrial activation throughout the CTI did not produce significant P wave deflections. Consequently, during AT, the left atrial activation time determined the P wave duration. This case demonstrates that AT originating from the CTI may exhibit narrow P waves which can be misinterpreted as AT originating from the inter-atrial septum.  相似文献   

3.
Phrenic Nerve Injury (PNI) has been well studied by cardiac surgeons. More recently it has been recognized as a potential complication of catheter ablation with a prevalence of 0.11 to 0.48 % after atrial fibrillation (AF) ablation. This review will focus on PNI after AF ablation. Anatomical studies have shown a close relationship between the right phrenic nerve and it's proximity to the superior vena cava (SVC), and the antero-inferior part of the right superior pulmonary vein (RSPV). In addition, the proximity of the left phrenic nerve to the left atrial appendage has been well established. Independent of the type of ablation catheter (4 mm, 8 mm, irrigated tip, balloon) or energy source used (radiofrequency (RF), ultrasound, cryothermia, and laser); the risk of PNI exists during ablation at the critical areas listed above. Although up to thirty-one percent of patients with PNI after AF ablation remain asymptomatic, dyspnea remain the cardinal symptom and is present in all symptomatic patients. Despite the theoretical risk for significant adverse effect on functional status and quality of life, short-term outcomes from published studies appear favorable with 81% of patients with PNI having a complete recovery after 7 +/- 7 months. CONCLUSION: Existing studies have described PNI as an uncommon but avoidable complication in patients undergoing pulmonary vein isolation for AF. Prior to ablation at the SVC, antero-inferior RSPV ostium or the left atrial appendage, pacing should be performed before energy delivery. If phrenic nerve capture is documented, energy delivery should be avoided at this site. Electrophysiologist's vigilance as well as pacing prior to ablation at high risk sites in close proximity to the phrenic nerve are the currently available tools to avoid the complication of PNI.  相似文献   

4.
Identification of the critical isthmus of the reentrant tachycardia is essential to maximize the effect of catheter ablation (CA) and to minimize the myocardial injury of CA. An 81-year-old woman presented recurrent palpitations after CA of atrial fibrillation (AF) and atrial tachycardia (AT). She had moderate aortic valve stenosis and coronary artery disease. She had received a pulmonary vein isolation, left atrial (LA) posterior wall isolation, and LA anterior linear ablation for atrial fibrillation 1 year prior. At the start of the procedure, she was in sinus rhythm. Atrial burst pacing induced an AT (230msec). High-density mapping revealed a figure-of-eight activation pattern within the LA appendage (LAA), accounting for 99% of the tachycardia cycle length. The critical isthmus was identified at the mid LAA and the local electrogram of the critical isthmus was not fractionated. A single radiofrequency application at the critical isthmus of the AT, terminated the AT. She was free from any ATs for 28 months.Radiofrequency ablation of the localized reentrant AT was usually performed targeting long fractionated electrograms. In our case, the local electrogram at the critical isthmus was not fragmented compared with the LAA distal part. Long fractionated electrograms were recorded at a more distal part of the LAA than the common isthmus and we could avoid the potential risk of a perforation. A recent developed 3-dimensional electro-anatomical mapping system can identify the critical isthmus and allow us to select a new therapeutic strategy for a critical isthmus ablation of an AT within the LAA.  相似文献   

5.
A 60-year-old man presented with sustained supraventricular tachycardia. Atrial tachycardia (AT), with the earliest atrial activation (EAA) occurring at the ostium of the coronary sinus, was reproducibly induced.Three-dimensional electroanatomical mapping (3DEAM) using a 3.5-mm distal electrode tip linear catheter (Thermocool) and radiofrequency energy (RF) was performed at the fractionated atrial electrogram site. It preceded at 30 ms to the EAA but did not terminate AT. Further 3DEAM using a multielectrode mapping catheter (Pentaray) demonstrated a centrifugal propagation pattern at the boundary zone between the right atrium and inferior vena cava. RF application here terminated AT, which then became non-inducible.  相似文献   

6.
A 57-year-old man underwent his seventh ablation session for atrial tachycardia (AT). His previous ablations involved several regions of the right atrium (RA) and left atrium (LA). The AT was characterized as biatrial tachycardia with a circuit involving the mitral annulus and septal RA. The AT was terminated by ablation through the insertion site of Bachmann’s bundle (BB) in both atria. After 3 months, the patient underwent his eighth ablation session because of AT recurrence. Activation maps showed that the connection from the RA to LA and vice versa was maintained via BB and the coronary sinus, respectively. The ablation target to interrupt the AT circuit was the mitral isthmus (MI), not BB, because BB supplied the electrical activation of the left atrial appendage (LAA) via a unidirectional electrical connection from the RA to LA. Ablation attempts from within the coronary sinus were performed to target the epicardial connection in the MI and led to complete blockage of the connection from the LA to RA. Otherwise, the connection from the RA to LA was preserved via BB. The patient was free of symptoms and anti-arrhythmic drugs at the 4-month follow-up. However, he had a high risk of electrical isolation of the LAA because extensive ablations had been performed; the strategy of targeting the MI contributed to the balance between preserving the electrical activation of the LAA and treating the biatrial tachycardia. Verification of the connective pathway between the two atria might be helpful to determine the optimal target.  相似文献   

7.
8.
BackgroundThere are limited data describing the experience of radiofrequency (RF) vs. cryoballoon (CB) ablation for atrial fibrillation (AF) among elderly patients in the United States.MethodsWe conducted a retrospective analysis of patients ≥75 years of age undergoing index RF vs. CB ablation between January 2014 and May 2020 at our center. The choice of ablation technique was left to the operator's discretion. Major complications and efficacy, defined as freedom from any atrial tachyarrhythmia (ATA) lasting ≥30 s after one year of follow-up, were assessed in patients with index RF vs. CB ablation.ResultsIn our cohort of 186 patients, the median age was 78 (76–81) years, 54.8% were men, and 39.2% had persistent AF. The median CHA2DS2-VASc score was 4 (3–4), while the median duration of AF was 3 (1–7) years. The majority (n = 112, 60.2%) underwent RF ablation. The median procedure time was significantly lower in CB group (197 vs 226.5 min, p=<0.01). The incidence of complications was similar in the two sub-groups (RF: 1.8% vs. CB: 2.7%, p = 0.67). Similarly, arrhythmia-free survival rate on antiarrhythmic drugs at 1-year follow-up remained statistically comparable (63.4% vs. 68.9%, p = 0.33) between patients receiving RF vs. CB ablation.ConclusionThe safety and efficacy of RF vs. CB ablation for AF remained comparable in our cohort of patients older than 75 years. CB ablation was associated with a shorter procedure time.  相似文献   

9.
Recent reports have described the incidence of atrioesophageal fistulas (AEF), often resulting in death, from radiofrequency (RF) catheter ablation of atrial fibrillation (AF).1 Cases of esophageal perforation without concomitant AEF have not been described as extensively.1 The precise mechanisms leading to esophageal injury after catheter ablation without involvement of the left atrium are not fully understood. The surgical approach to treat esophageal perforation is strongly recommended.2 However, a unified surgical treatment approach has not yet been established. We describe a case of successful surgical repair of an esophageal perforation after ablation using surgical repair in combination with an omental wrap.  相似文献   

10.
In selected patients with atrial fibrillation and severe symptoms, non-pharmacological treatment may be an alternative or supplement to drug therapy. Atrioventricular nodal radiofrequency ablation (requires pacemaker implantation), or atrial pacing for sick sinus syndrome, are established treatment modalities. All other non-pharmacological therapies for atrial fibrillation are still experimental. After the Maze operation, atrial depolarization has to follow one specific path determined by surgical scars in the myocardium. This prevents new episodes of atrial fibrillation, but at a cost of perioperative morbidity and mortality. Catheter-based "Maze-like" radiofrequency ablation is technically difficult, and thrombo-embolic complications may occur. Paroxysmal atrial fibrillation sometimes is initiated by spontaneous depolarizations in a pulmonary vein inlet. Radio frequency ablation against such focal activity has been reported with high therapeutic success, but the results await confirmation from several centres. For ventricular rate control, most electrophysiologists presently prefer ablation to induce a complete atrioventricular conduction block (with pacemaker) rather than trying to modify conduction by incomplete block. Atrial or dual chamber pacing may prevent atrial fibrillation induced by bradycardia. It remains to confirm that biatrial or multisite right atrial pacing prevents atrial fibrillation more efficiently than ordinary right atrial pacing. An atrial defibrillator is able to diagnose and convert atrial fibrillation. The equipment is expensive, and therapy without sedation may be unpleasant beyond tolerability.  相似文献   

11.
A case of macro-reentrant tachycardia associated with a box lesion after thoracoscopis left atrial surgical atrial fibrillation (AF) ablation yet to be described. The goal was to clarify the mechanisms and electrophysiological characteristics of this type of tachycardia.A patient was admitted for an EP study following surgical thoracoscopic AF ablation (box lexion formation by right-sided Cobra thoracoscopic ablation). Thoracoscopic ablation was done as the first step of the hybrid ablation approach to the persistent AF; the second step was the EP study. At the EP study, he presented with incessant regular tachycardia (cycle length of 226 ms). An EP study with conventional, 3D activation and entrainment mapping was done to assess the tachycardia mechanism. Two conduction gaps in the superior line (roofline) between the superior pulmonary veins were discovered. The tachycardia was successfully treated with a radiofrequency application near the gap close to the left superior pulmonary vein; however, following tachycardia termination, pulmonary vein isolation was absent. A second radiofrequency application, close to the roof of the right superior pulmonary, vein closed the gap in the box and led to the isolation of all 4 pulmonary veins. No atrial tachycardia recurred during the 6-month follow-up.Conduction gaps in box lesion created by thoracospcopic ablation can present as a novel type of man-made tachycardia after surgical ablation of atrial fibrillation. Activation and entrainment mapping is necessary for an accurate diagnosis.  相似文献   

12.
The thoracic vein hypothesis of chronic atrial fibrillation (AF) posits that rapid, repetitive activations from muscle sleeves within thoracic veins underlie the mechanism of sustained AF. If this is so, thoracic vein ablation should terminate sustained AF and prevent its reinduction. Six female mongrel dogs underwent chronic pulmonary vein (PV) pacing at 20 Hz to induce sustained (>48 h) AF. Bipolar electrodes were used to record from the atria and thoracic veins, including the vein of Marshall, four PVs, and the superior vena cava. Radio frequency (RF) application was applied around the PVs and superior vena cava and along the vein of Marshall until electrical activity was eliminated. Computerized mapping (1,792 electrodes, 1 mm resolution) was also performed. Sustained AF was induced in 30.6 +/- 6.5 days, and ablation was done 17.3 +/- 8.5 days afterward. Before ablation, the PVs had shorter activation cycle lengths than the atria, and rapid, repetitive activations were observed in the PVs. All dogs converted to sinus rhythm during (n = 4 dogs) or within 90 min of completion of RF ablation. Rapid atrial pacing afterward induced only nonsustained (<60 s) AF in all dogs. Average AF cycle lengths after reinduction were significantly (P = 0.01) longer (183 +/- 31.5 ms) than baseline (106 +/- 16.2 ms). There were no activation cycle length gradients after RF application. We conclude that thoracic vein ablation converts canine sustained AF into sinus rhythm and prevents the reinduction of sustained AF. These findings suggest that thoracic veins are important in the maintenance of AF in dogs.  相似文献   

13.

Introduction

Catheter ablation of longstanding (> 1 year) persistent atrial fibrillation (AF) is associated with poor outcome. This might be due to remodelling and fibrosis formation, mainly located in the posterior left atrial (LA) wall. Therefore, we adopted a thoracoscopic epicardial box isolation of the posterior left atrium using bipolar RF energy with intraoperative testing of conduction block.

Methods and results

Bilateral thoracoscopic box isolation was performed with a bipolar RF clamp. Entrance block was defined as absence of a conducted electrogram within the box, while exit block was confirmed by pacing at 10.0 V/2 ms. Ablation outcome was evaluated after 3, 6, 12 and 24 months with 12-lead ECGs and 24-hour Holter recordings.Twenty-five consecutive patients were included (58 ± 7 years, persistent AF duration 1.8 ± 0.9 years). Entrance block was achieved in all patients and exit block confirmed if sinus rhythm was achieved. After 17 ± 7 months, 76 % of the patients (n = 19) were free of AF recurrence. One patient died within 1 month and was considered an ablation failure. Four patients with AF recurrences regained sinus rhythm with additional catheter ablation or antiarrhythmic drugs.

Conclusions

Treatment of longstanding persistent AF with thoracoscopic epicardial LA posterior box isolation using bipolar RF energy with intraoperative testing of conduction block is feasible and highly effective.  相似文献   

14.
目的:分析经食道心房调搏术(TEAP)及食道内心电图(EECG)在心律失常中的应用价值。方法:选取2018年6月至2019年12月于我院行食道心电图及经食道调搏的患者189例,其中男80例,女109例,年龄11~83岁。结果:54例为房室结折返性心动过速(AVNRT),34例为房室折返性心动过速(AVRT),8例为房性心动过速(AT),4例为心房扑动(AF),6例为心房颤动(Af),5例为室性心过速,78例为室早或其他。共105例心律失常患者拟行食道心房调搏终止心动过速,所有AVNRT和AVRT患者及17例AT患者经食道心房调搏S1S1成功转为窦律,50例AVNRT、32例AVRT、6例AT、3例AF及2例VT患者通过射频消融术成功根治。其中1例11岁AT患者因无法耐受食道调搏,未能转为窦律,患者经静推普罗帕酮后次日转为窦律。共97例患者拟行食道心房调搏诱发,共49例诱发出心动过速,1例左后分支型室速经静滴异丙肾上腺素后诱发心动过速,且仍需静滴异丙肾上腺素后经心房食道调博终止心动过速,后经射频消融术成功根治。结论:TEAP及EECG可用于复杂心律失常的诊断及治疗,是一种相对安全、临床容易掌握的技术,值得推广。  相似文献   

15.
目的应用微电极阵列芯片(microelectrode arrays chip,MEA)技术评价48 h房颤(atrial fibrillation,AF)犬左、右心耳(LAA、RAA)的电生理特性。方法随意来源犬12只,以600次/分起搏右心房建立AF模型,分为48 h AF组(n=6)和对照组(n=6)。造模成功后迅速开胸剪取LAA、RAA,置于盛有台式液的MEA中,分别记录AF组及对照组LAA、RAA场电位(field action potential,FAP)形态、振幅、放电频率及激动传导情况。结果 AF组LAA、RAA组织FAP节律绝对不齐,LAA(185.22±25.62)次/分,较对照组(156.44±8.88)次/分增加15.67%(P〈0.01),RAA(102.39±16)次/分,较对照组(156.44±8.88)次/分减慢34.62%(P〈0.01)。48 h AF组LAA组织电压(458.33±26.73)μV较对照组(740.55±18.93)μV降低38.11%(P〈0.01),RAA(504.83±39.93)μV较对照组(840.56±18.93)μV明显降低(P〈0.01),48 h房颤组LAA组织FAP时程(45.28±8.59)ms较对照组(70.77±6.98)ms缩短15 ms(P〈0.01)。RAA(61.78±7.1)ms较对照组(75.83±7.63)ms缩短14 ms(P〈0.01)。48 h AF组LAA、RAA FAP传导异质性增加。结论应用MEA技术可反映心肌组织片场电位电生理特性,48 h AF后LAA放电频率增加,频率绝对不齐,LAA、RAA电压降低,场电位时程延长。  相似文献   

16.
We report on a 22-month-old boy with drug-resistant atrioventricular reentrant tachycardia and complex structural heart disease consisting of right atrial isomerism, mirror image orientation of the intrathoracic veins, hemi-azygos continuation to the left superior vena cava, separate drainage of the hepatic veins into the left-sided atrium, congenitally corrected transposition, pulmonary atresia, and atrial and ventricular septal defects.Access to the heart for radiofrequency (RF) ablation was obtained by percutaneous puncture of a hepatic vein, the left internal jugular vein, and femoral artery. The accessory pathway was localised to the free wall of the left-sided AV groove and successfully ablated. There were no procedure-related complications.RF ablation of an accessory pathway is feasible in young children with complex structural heart disease and abnormal systemic venous return. In such patients access to the heart must be planned with knowledge of the anatomy and judicious use of the hepatic venous approach.  相似文献   

17.
Macroreentrant atrial circuits are frequently associated with scarring. Previous reports have shown the possible development of scar tissue that is adjacent to pacemaker (PM) leads. However, reports of PM lead-related reentrant tachycardia are scarce. We report the case of a 63-year-old woman who presented with macroreentrant atrial tachycardia (MAT), related to the atrial trajectory of an old single-lead ventricular PM, that was successfully treated with radiofrequency ablation after a conventional electrophysiological study ruled out isthmus-dependent atrial flutter and provided sufficient data to confirm this diagnosis. This report presents a case of MAT originating around the trajectory of a PM lead, probably because of scar tissue that developed adjacent to the lead. Experimental studies have already shown that interstitial atrial fibrosis may develop adjacent to a ventricular single-lead. This finding suggests that MAT develops in patients with this specific condition. Recognizing this condition is important for managing these arrhythmias and performing safe ablation with the preservation of PM lead integrity.  相似文献   

18.
Incisional sustained tachycardias are frequent in patients who have undergone a surgical repair of interatrial defect. A 43-year-old woman with drug refractory, highly symptomatic, persistent atrial tachycardia in the last year, was referred to our unit for catheter ablation. The patient had undergone a cardiac operation for repairing interatrial secundum ostium type defect with a patch five years before. A previous radiofrequency ablation procedure had been performed for common atrial flutter. We describe a case of incisional atrial tachycardia ablation guided by the new EnSite NavX system equipped with a new electroanatomic mapping system.  相似文献   

19.
Aortic valve stenosis (AVS) and coronary artery disease (CAD) are accompanied by changes in the cardiac extra cellular matrix (cECM) including the re-expression of oncofetal fibronectin (Fn) and tenascin-C (Tn-C) variants. Human antibodies against these variants are usable for targeted therapy. Aim of the study was the comparative analysis of cECM remodelling in tissue samples from right atrial auricle (RAA) and left ventricular septum (LVS). RAA and LVS specimens from 30 patients (17?×?AVS; 13?×?AVS+CAD) were analysed with respect to histological changes and ECM remodelling using PCR based ECM gene expression profiling. Re-expression of ED-A(+) Fn and A1(+) Tn-C was investigated on the mRNA and on the protein level. For immunofluorescence, human recombinant small immunoprotein (SIP) format antibodies were used. There was a positive correlation of the grade of histological changes in RAA and corresponding LVS samples (r?=?0.695). ECM gene expression levels were higher in LVS compared to RAA. For 24 genes, a corresponding relevant (>2.5-fold) up- or down-regulation in RAA and LVS occurred. Using SIP antibodies, a positive correlation of protein deposition levels in RAA and corresponding LVS (r?=?0.818) could be shown for ED-A(+) Fn. Cardiac tissue remodelling is likely a process involving the entire heart reflected by intra-individually comparable histology and cECM changes in RAA and LVS samples. ED-A(+) Fn might be an excellent target for an antibody-mediated delivery of diagnostic or therapeutic agents. The RAA is a valuable and representative tool to evaluate cardiac remodelling and to plan individualized therapy.  相似文献   

20.
Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillation. The objective of this article is to review efficacy and safety data surrounding cryoballoon ablation for paroxysmal and persistent atrial fibrillation. In addition, a practical step-by-step approach to cryoballoon ablation is presented, while highlighting relevant literature regarding: 1) the rationale for adjunctive imaging, 2) selection of an appropriate cryoballoon size, 3) predictors of efficacy, 4) advanced trouble-shooting techniques, and 5) strategies to reduce procedural complications, such as phrenic nerve palsy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号