首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
血清蛋白质指纹图谱诊断早期胃癌临床意义   总被引:2,自引:0,他引:2       下载免费PDF全文
目的:应用SELDI蛋白质芯片检测胃癌患者血清蛋白质指纹图谱,筛选候选肿瘤标志物以建立诊断模型。方法:表面加强激光解吸电离-飞行时间质谱(SELDI-TOF-MS)技术及其配套蛋白质芯片检测34例胃癌患者(Ⅰ/Ⅱ期12例与Ⅲ/Ⅳ期22例)和30例健康人的血清蛋白质组图谱,运用判别分析处理数据筛选标志物并建立诊断模型。结果:2046m/z、1179m/z、1817m/z、1752m/z和1588m/z等5个蛋白质峰组合所构建的诊断模型能达到鉴别胃癌患者和健康人的最佳诊断效果,特异度94.1%(32/34),灵敏度93.3%(28/30)。单个4665m/z蛋白质峰诊断模型可达到鉴别Ⅰ/Ⅱ期与Ⅲ/Ⅳ期胃癌效果,其特异度91.6%(11/12),灵敏度95.4%(21/22)。结论:该方法在胃癌的诊断尤其是早期诊断方面具有一定价值,值得进一步研究。  相似文献   

2.
A chiral liquid chromatography/mass spectrometry (LC/MS) bioanalytical procedure has been developed for the analysis of the antimalaric agent Fenozan B07 in dog plasma. Normal-phase chromatography involving a phenylcarbamate derivative of cellulose coated on silica gel as the chiral stationary phase was used to resolve (-)-(S,S)-B07 from (+)-(R,R)-B07. The enantiomers were detected by a mass spectrometer equipped with an atmospheric pressure chemical ionization (APCI) interface operated in the negative ion mode. A mass spectrum, characterized by a base peak of m/z 285, was obtained for each enantiomer. The m/z 285 ion was very specific for the analysis of both enantiomers in the plasma. The selected ion monitoring analysis of the plasma samples was therefore performed at m/z 285 for quantitative purposes. The enantiomers were extracted from the plasma in a basic medium and purified by solid-phase extraction using a hydrophilic-lipophilic balanced sorbent. A lower limit of quantification of 2 ng/mL in plasma was achieved for both enantiomers. The quantitative procedure reported in this study was highly specific and sensitive, and was validated according to the FDA guidance on bioanalytical method validation.  相似文献   

3.
The isotope ratios of monoterpene hydrocarbons in Citrus junos Tanaka (yuzu) essential oils from different origins were determined by ordinary high-resolution gas chromatography-mass spectrometry (HRGC-MS). Both intensities of the molecular mass peaks (m/z 136) and of the isotope peaks (m/z 137) of monoterpene hydrocarbons were measured by single-ion monitoring with an MS analysis. The isotope ratios (m/z 137/136) of the ten monoterpene hydrocarbons commonly contained in citrus essential oils, α-pinene, β-pinene, sabinene, myrcene, α-phellandrene, α-terpinene, limonene, γ-terpinene, β-phellandrene and terpinolene, were determined in yuzu samples of the highest commercial quality from 42 different production districts. Statistical treatment of these data by the t-test and sign test revealed significant differences of the isotope effects in each yuzu sample. It is suggested that this technique will be applicable for evaluating the quality, genuineness and origin of citrus fruits and their products. The isotope fingerprints were also demonstrated in several citrus fruits other than the yuzu samples.  相似文献   

4.
We have determined three opioidmimetics (compounds I-III) in the rat brain dialysates after intraperitoneal (i.p.) administration of compounds I-III using a liquid chromatography/mass spectrometry with tandem mass spectrometry (LC-MS/MS). The dialysate samples with methanol were directly analyzed by online column-switching liquid chromatography. Using multiple reaction monitoring (MRM, product ions m/z 421 of m/z 657 for compound I, m/z 421 of m/z 643 for compound II, and m/z 407 of m/z 629 for compound III) on LC-MS/MS with electrospray ionization (ESI), opioidmimetics in rat brain dialysates were determined. Calibration curves of the method showed a good linearity in the range of 10-100 ng/ml for each compound. The limit of determination was estimated to be ca. 1 ng/ml for compounds II and III, and ca. 5 ng/ml for compound I, respectively. The precision of analysis showed coefficients of variation ranging from 4.7 to 10.4% at compound III concentration (10-100 ng/ml) in Ringer's solution. As a result, the procedure proved to be very suitable for routine analysis. The method was applied to the analysis of three opioidmimetics in the brain dialysate samples from rats treated with these compounds.  相似文献   

5.
The synthetic opioid peptide analog Dmt-D-Arg-Phe-Lys-NH(2) ([Dmt(1)]DALDA; [Dmt= 2',6'-dimethyltyrosine) is a highly potent and selective mu opioid-receptor agonist. A very sensitive and robust capillary liquid chromatography/nanospray ion-trap (IT) mass spectrometry method has been developed to quantify [Dmt(1)]DALDA in ovine plasma, using deuterated [Dmt(1)]DALDA as the internal standard. The standard MS/MS spectra of d(0)- and d(5)-[Dmt(1)]DALDA were obtained, and the collision energy was experimentally optimized to 25%. The product ion [ M + 2H-NH(3)](2+) (m/z 312.2) was used to identify and to quantify the synthetic opioid peptide analog in ovine plasma samples. The MS/MS detection sensitivity for [Dmt(1)]DALDA was 625 amol. A calibration curve was constructed, and quantitative analysis was performed on a series of ovine plasma samples.  相似文献   

6.
A liquid chromatography-electrospray tandem mass spectrometry method was developed and validated to quantitate solifenacin in human plasma. The assay was based on protein precipitation with methanol and liquid chromatography performed on a pentafluorophenylpropylsilica column (50×4mm, 3μm particles), the mobile phase consisted of methanol - 100mM ammonium acetate containing 1% of formic acid (90:10, v/v). Quantification was through positive-ion mode and selected reaction monitoring at m/z 363→193 and 368→198 for solifenacin and the internal standard solifenacin-D(5), respectively. The lower limit of quantitation was 0.47ng/ml using 0.25ml of plasma and linearity was demonstrated up to 42ng/ml. Intra-assay and inter-assay precision expressed by relative standard deviation was less than 11% and inaccuracy did not exceed 11% at all levels. The assay was applied to the analysis of samples from a pharmacokinetic study.  相似文献   

7.
We determined cabergoline and L-dopa in human plasma using liquid chromatography-mass spectrometry with tandem mass spectrometry (LC-MS-MS). The deproteinized plasma samples with organic solvent or acid were analyzed directly by reversed-phase liquid chromatography. Using multiple reaction monitoring (MRM, product ions m/z 381 of m/z 452 for cabergoline and m/z 152 of m/z 198 for L-dopa) on LC-MS-MS with electrospray ionization (ESI), cabergoline and L-dopa in human plasma were determined. Calibration curves of the method showed a good linearity in the range 5-250 pg/ml for cabergoline and 1-200 ng/ml for L-dopa, respectively. The limit of determination was estimated to be approximately 2 pg/ml for cabergoline and approximately 0.1 ng/ml for L-dopa, respectively. The method was applied to the analysis of cabergoline and L-dopa in plasma samples from patients treated with these drugs. The precision of analysis showed coefficients of variation ranging from 3.8% to 10.5% at cabergoline concentration of 13.8-26.2 pg/ml and from 2.9% to 8.9% at an L-dopa concentration of 302.5-522.1 ng/ml in patient plasma. As a result, the procedure proved to be very suitable for routine analysis.  相似文献   

8.
Serum samples from non-Hodgkin lymphoma (NHL) patients who had not undergone chemotherapy, lymphnoditis patients, and healthy adults were analyzed using surface-enhanced laser desorption–ionization time-of-flight mass spectrometry (SELDI-TOF MS) to detect the differentially expressed serum proteins. Models were developed to distinguish between the healthy adult group and the NHL group, with a sensitivity of 69% and specificity of 90%, and between the lymphnoditis group and the NHL group with a sensitivity of 74% and specificity of 84%. A protein with the m/z of M10 197.91 u was expressed at a significantly higher level in the NHL group, compared to the other groups. Furthermore, differences were also significant among different stages of NHL and among samples with different International Prognosis Index (IPI) scores or lactase dehydrogenase (LDH) levels. The three identified proteins may offer a new serological approach for early diagnosis, differential diagnosis, and pathogenic investigation of NHL. And the protein with the m/z of M10 197.91 u may be a new serological biomarker for monitoring treatment response and evaluating the prognosis of patients with NHL.  相似文献   

9.
Fast atom bombardment (FAB) and collisional activation dissociation (CAD) mass-analysed ion kinetic energy (MIKE) spectra have confirmed the structures of retinyl phosphate (Ret-P), retinyl phosphate mannose (Ret-P-Man) and guanosine 5'-diphospho-D-mannose (GDP-Man). Ret-P-Man was made in vitro while Ret-P and GDP-Man were chemically synthesized. Positive ion FAB mass spectrometry of Ret-P showed an observable short-lived spectrum with a mass ion at m/z 367 [M + H]+, and a major fragment ion at m/z 269 [M + H - H3PO4]+. Negative ion FAB mass spectrometry of Ret-P showed a strong stable spectrum with a parent ion at m/z 365 [M - H]-, a glycerol (G) adduct ion at m/z 457 [M - H + G]- and a dimer ion at m/z 731 [2M - H]-. GDP-Man showed an intense spectrum with parent ion at m/z 604 [M - H]- and cationized species at m/z 626 [M + Na - 2H]- and 648 [M + 2Na - 3H]-. Negative ion FAB mass spectrometry of Ret-P-Man showed a parent ion at m/z 527 [M - H]- and a fragment ion at m/z 259 [C6H12PO9]-. The CAD-MIKE spectra showed structurally significant fragment ions at m/z 442 and 361 for the [M - H]- ion of GDP-Man, and at m/z 509, 406, 364 and 241 for the [M - H]- ion of Ret-P-Man. FAB and CAD-MIKE spectra have been applied successfully to confirm the structure of Ret-P-Man made in vitro from Ret-P and GDP-Man.  相似文献   

10.
Ammuxetine (AMT), a novel chiral antidepressant candidate compound, exhibits better antidepression effects than duloxetine in different animal models. In this article, a chiral derivatization method, combined with online solid phase extraction (online SPE) and liquid chromatography–tandem mass spectrometry (LC–MS/MS), was developed for the chiral separation of AMT enantiomers after administration of racemic AMT to dogs. The derivatization reaction employed 2,3,4,6‐tetra‐O‐acetyl‐b‐glucopyr‐anosyl isothiocyanate (GITC) as a precolumn chiral derivatization reagent. A SPE column Retain PEP Javelin (10 × 2.1 mm) was used to remove proteins and other impurities in plasma samples. The enantiomeric derivatives were separated on a ZORBAX SB‐C18 column (50 × 2.1 mm × 3.5 μm) with an isocratic elution procedure. The selected multiple reaction monitoring mode of the positive ion was performed and the parent to the product transitions m/z 681.0/543.1 and m/z 687.4/543.1 were used to measure the derivatives of AMT and duloxetine (internal standard) with electrospray ionization. The method was validated in terms of specificity, linearity, sensitivity, precision, accuracy, matrix effect, and stability. The method was applied to a pharmacokinetics study of AMT racemate in dogs. The results suggested that the pharmacokinetic of AMT enantiomers might be stereoselective in dogs.  相似文献   

11.
11 alpha-Hydroxy-9,15-dioxo-2,3,4,5,20-pentanor-19-carboxyprostano ic acid (PGE-M) and 9 alpha,11 alpha-dihydroxy-15-oxo-2,3,4,5,20-pentanor-19-carboxyprostanoic acid (PGF-M) in urine were determined in an isotope dilution assay by gas chromatography/triple-stage quadrupole mass spectrometry. After addition of the 2H7-labeled internal standard, O-methylhydroxylamine hydrochloride in acetate buffer was added either directly (PGE-M) or after standing overnight at pH 10 (PGF-M) to form the methoxime. The sample was acidified to pH 2.5 and PGE-M and PGF-M were extracted with ethyl acetate/hexane. Then the prostanoids were derivatized to the pentafluorobenzyl ester and purified by thin-layer chromatography and the trimethylsilyl ether was formed. The products were quantified by gas chromatography/triple-stage quadrupole mass spectrometry. For PGE-M, the fragment ions m/z 349 and m/z 356 (2H7 standard) (daughter ions of m/z 637 and m/z 644 (2H7 standard] were used. The results of the PGE-M assay were compared with those of an assay using the [2H3]methoxime as the internal standard. For determination of PGF-M, the daughter ions m/z 484 and m/z 491 (2H7 standard) with the parent ions m/z 682 and m/z 689 (2H7 standard) were chosen.  相似文献   

12.
A new method for detection of tetrodotoxin (TTX) by thin-layer chromatography/fast atom bombardment (FAB) mass spectrometry was developed. TTX and/or related substances were separated by TLC on LHP-K high-performance precoated plates, with a solvent system of pyridine:ethyl acetate:acetic acid:water (15:5:3:4). The plates were subjected to positive FAB mass spectrometry, under scanning within a mass range from m/z 100 to 500. TTX was identified by selected ion-monitored chromatograms at m/z 320 (M + H)+ and 302 (M + H - H2O)+, along with full scan positive ion FAB mass spectrometry. The limit of detection for TTX was about 0.1 micrograms. TTX was also detected by cellulose acetate membrane electrophoresis/FAB mass spectrometry.  相似文献   

13.
Miao F  Lu D  Li Y  Zeng M 《Analytical biochemistry》2006,352(2):176-181
After first being analyzed by HPLC, 4 free carotenoids, 15 astaxanthin monoesters, 12 astaxanthin diesters, and 3 astacin monoesters in Haematococcus pluvialis were identified by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (LC-(APCI)MS). Identification of each compound was based on the characteristic fragment ions of the positive ion mode, negative ion mode, and MS(2). Astaxanthin esters were identified based on the loss of one or two fatty acids. In a positive ion mode, astaxanthin monoesters had characteristic fragment ions at m/z 597 [M+H-fatty acid](+) and m/z 579 and 561 that resulted from a continuous loss of water. The relative intensity of m/z 579 in MS(2) amounted to more than 80% of that of the molecular ion. In astaxanthin diesters, the intensity of m/z 561 occasionally was equal to that of m/z 579, but in general the former, amounting to 50 to 60% or more of the molecular ion, was stronger than the latter, which decreased to 20 to 30% of the molecular ion. In addition, a set of compounds with maximum absorbance at 400 nm, detected by high-performance liquid chromatography-diode array detector (HPLC-DAD), had strong characteristic fragment ions at m/z 871 and 593 in the positive ion mode MS(2). They were presumed to be linolenic acid or an isomer of omega-6-gamma-linolenic acid esters of astacin.  相似文献   

14.
A simple, reliable and sensitive liquid chromatography-tandem mass spectrometry method (LC-MS/MS) was developed and validated for quantification of N-acetylglucosamine in human plasma. Plasma samples were pretreated with acetonitrile for protein precipitation. The chromatographic separation was performed on Hypersil Silica column (150mmx2mm, 5microm). The deprotonated analyte ion was detected in negative ionization mode by multiple reaction monitoring mode. The mass transition pairs of m/z 220.3-->118.9 and m/z 226.4-->123.2 were used to detect N-acetylglucosamine and internal standard 13C6-N-acetylglucosamine, respectively. The assay exhibited a linear range from 20 to 1280ng/ml for N-acetylglucosamine in human plasma. Acceptable precision and accuracy were obtained for concentrations of the calibration standard and quality control. The validated method was successfully applied to analyze human plasma samples in a pharmacokinetic study.  相似文献   

15.
MALDI-TOF质谱技术对克罗诺杆菌的鉴定与分型   总被引:3,自引:1,他引:2  
以基质辅助激光解析电离飞行时间质谱(MALDI-TOFMS)技术用于克罗诺杆菌的鉴定与分型。通过对获得的克罗诺杆菌属典型菌株、阴沟肠杆菌和产气肠杆菌近似菌株以及克罗诺杆菌分离株的蛋白质质量图谱进行对比分析,找出克罗诺杆菌特征性离子峰,将其作为鉴定克罗诺杆菌的生物标识物;对全细菌蛋白质质量图谱进行聚类分析,将克罗诺杆菌属进一步划分为不同类型,结果显示,4株克罗诺杆菌参考菌株质量图谱约在5740(m/z)离子质荷比处出现1个相近离子峰,28株克罗诺杆菌分离株中27株(占96.4%)表现出相同结果;32株克罗诺杆菌被分为6种类型(以50%距离水平为分类界限)。MALDI-TOFMS作为一种新的技术,不仅能够用于克罗诺杆菌的鉴定,而且根据获得的细菌蛋白质质量图谱可将克罗诺杆菌划分为不同类型。  相似文献   

16.
Time-Of-Flight Mass Spectrometry (TOF-SIMS) was used to determine elemental and biomolecular ions from isolated protein samples. We identified a set of 23 mass-to-charge ratio (m/z) peaks that represent signatures for distinguishing biological samples. The 23 peaks were identified by Singular Value Decomposition (SVD) and Canonical Analysis (CA) to find the underlying structure in the complex mass-spectra data sets. From this modified data, SVD was used to identify sets of m/z peaks, and we used these patterns from the TOF-SIMS data to predict the biological source from which individual mass spectra were generated. The signatures were validated using an additional data set different from the initial training set used to identify the signatures. We present a simple method to identify multiple variables required for sample classification based on mass spectra that avoids overfit. This is important in a variety of studies using mass spectrometry, including the ability to identify proteins in complex mixtures and for the identification of new biomarkers.  相似文献   

17.
In this study the analysis and confirmation of flumequine enantiomers in rat plasma by ultra‐fast liquid chromatography coupled with electron spray ionization mass spectrometry (using propranolol as an internal standard [IS]) was developed and validated. Plasma samples were prepared by liquid–liquid extraction using methyl tert‐butyl ether as the extraction solvent. Direct resolution of the R‐ and S‐isomers was performed on a CHIRALCEL OJ‐RH column (4.6 × 150 mm, 5 μm) using acetonitrile / 0.1% formic acid / 1 mM ammonium acetate as the mobile phase. Detection was operated by electron spray ionization in the selected ion monitoring and positive ion mode. The target ions at m/z 262.1 and m/z 260.1 were selected for the quantification of the enantiomers and IS, respectively. The linear range was 0.5–500 ng/mL. The precisions (coefficient of variation, CV%) and recoveries were 1.43–8.68 and 94.24–106.76%, respectively. The lowest quantitation limit for both enantiomers is 0.5 ng/mL, which is sensitive enough to be applied to sample analysis in other related studies.  相似文献   

18.
目的:利用HPLC-MS/MS方法对十种一碳代谢相关产物进行定量分析。方法:采用Aglient ZORBAX SB-AQ C18柱(2.1mm×100 mm,3.5 m)、电喷雾离子源(ESI),以多离子反应监测方式(MRM)进行正离子检测。对游离叶酸(FA)、5-甲酰四氢叶酸(5-FT)、5-甲基四氢叶酸(5-MT)、S-腺苷蛋氨酸(SAM)、S-腺苷同型半胱氨酸(SAH)、胱硫醚(CYSTA)、组氨酸(HIS)、丝氨酸(SER)、蛋氨酸(MET)、同型半胱氨酸(HCY)进行定量分析。结果:FA、5-FT、5-MT、SAM、SAH、CYSTA、HIS、SER、MET、HCY的检测限分别为0.1 ng.L-1、0.25 ng.L-1、0.1 ng.L-1、0.1 ng.L-1、0.25 ng.L-1、0.25 ng.L-1、0.1 ng.L-1、0.025 ng.L-1、0.1 ng.L-1、0.1 ng.L-1。FA、5-FT、5-MT、SAH、CYSTA浓度测定方法线性范围为2~50 ng.L-1,SER、SAM浓度测定方法线性范围20~500 ng.L-1,MET、HCY浓度测定方法线性范围200~5000 ng.L-1,HIS浓度测定方法线性范围为400~10000 ng.L-1,r均在0.993以上,全部涵盖了已报道的血清中指标的含量范围。结论:建立了HPLC-MS/MS方法,可同时分析十种一碳代谢通路的关键产物,所需样品量少,检测速度快,同时实现分项检测,可为多种代谢性疾病系统性地检测一碳代谢中间产物体液分析方法建立实验条件基础。  相似文献   

19.
The validation of a liquid chromatography-tandem mass spectrometry (LC-MS-MS) method for the determination of the selective cyclooxygenase-2 inhibitor etoricoxib in human plasma with phenazone as internal standard is described. The plasma samples were extracted by solid-phase extraction using polymer-based cartridges. Chromatography was carried out on a short, narrow bore RP C(18) column (30x2 mm). Detection was achieved by a Sciex API 3000 triple quadrupole mass spectrometer equipped with a turbo ion spray source working in positive ion mode. The respective mass transitions used for quantification of etoricoxib and phenazone were m/z 359.2-->280.2 and m/z 189.0-->104.1. The analytical method was validated over the concentration range 0.2-200 ng/ml. The limit of quantification was 0.2 ng/ml. The method is applicable to pharmacokinetic studies in humans.  相似文献   

20.
An HPLC-MS/MS assay for the determination of an HIV integrase inhibitor, 5-(1,1-dioxido-1,2-thiazinan-2-yl)-N-(4-fluorobenzyl)-8-hydroxy-1,6-naphthyridine-7-carboxamide (I) in human plasma has been developed and validated. Compound I and a stable isotope labeled internal standard (II) were isolated from 0.5 mL plasma samples by solid phase extraction using an Ansys SPEC C-8 96-well plate. Extracts were separated on a Hypersil BDS C-18 HPLC column (3.0 mmx50 mm, 3 microm) with a mobile phase consisting of 25 mM ammonium formate pH 3.0:acetonitrile (60:40) vol%/vol% pumped at 0.5 mL/min. A Sciex API 365 mass spectrometer equipped with an atmospheric pressure chemical ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 431-->109 (I) and m/z 437-->115 (II) used for quantitation. The assay was validated over the concentration range of 10-5000 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was 69%. The intra-day accuracy of the assay was within 4% of nominal and intra-day precision was better than 4% C.V. Following a 200 mg dose of the compound administered to human subjects, concentrations of I ranged from 21.1 to 1500 ng/mL in plasma samples collected up to 12 h after dosing. Inter-day accuracy and precision results for quality control samples run over a 3-month period alongside clinical samples showed mean accuracies of within 6% of nominal and precision better than 3.5% C.V.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号