共查询到20条相似文献,搜索用时 889 毫秒
1.
Teresa Fiebig Giovanna Figueiredo Hanne Boll Hans Ulrich Kerl Ingo S. Noelte Alex Forster Christoph Groden Martin Kramer Marc A. Brockmann 《PloS one》2013,8(6)
Purpose
Small injection ports for mice are increasingly used for drug testing or when administering contrast agents. Commercially available mini-ports are expensive single-use items that cause imaging-artifacts. We developed and tested an artifact-free, low-cost, vascular access mini-port (VAMP) for mice.Procedures
Leakage testing of the VAMP was conducted with high speed bolus injections of different contrast agents. VAMP-induced artifacts were assessed using a micro-CT and a small animal MRI (9.4T) scanner ex vivo. Repeated contrast administration was performed in vivo.Results
With the VAMP there was no evidence of leakage with repeated punctures, high speed bolus contrast injections, and drawing of blood samples. In contrast to the tested commercially available ports, the VAMP did not cause artifacts with MRI or CT imaging.Conclusions
The VAMP is an alternative to commercially available mini-ports and has useful applications in animal research involving imaging procedures and contrast agent testing. 相似文献2.
Purpose
Respiratory motion causes substantial artifacts in reconstructed PET images when using helical CT as the attenuation map in PET/CT imaging. In this study, we aimed to reduce the respiratory artifacts in PET/CT images of patients with lung tumors using an abdominal compression device.Methods
Twelve patients with lung cancer located in the middle or lower lobe of the lung were recruited. The patients were injected with 370 MBq of 18F-FDG. During PET, the patients assumed two bed positions for 1.5 min/bed. After conducting free-breathing imaging, we obtained images of the patients with abdominal compression by applying the same setup used in the free-breathing scan. The differences in the standardized uptake value (SUV)max, SUVmean, tumor volume, and the centroid of the tumors between PET and various CT schemes were measured.Results
The SUVmax and SUVmean derived from PET/CT imaging using an abdominal compression device increased for all the lesions, compared with those obtained using the conventional approach. The percentage increases were 18.1% ±14% and 17% ±16.8% for SUVmax and SUVmean, respectively. PET/CT imaging combined with abdominal compression generally reduced the tumor mismatch between CT and the corresponding attenuation corrected PET images, with an average decrease of 1.9±1.7 mm over all the cases.Conclusions
PET/CT imaging combined with abdominal compression reduces respiratory artifacts and PET/CT misregistration, and enhances quantitative SUV in tumor. Abdominal compression is easy to set up and is an effective method used in PET/CT imaging for clinical oncology, especially in the thoracic region. 相似文献3.
Hiroshi Igaki Akira Sakumi Akitake Mukasa Kuniaki Saito Akira Kunimatsu Yoshitaka Masutani Shunya Hanakita Kenji Ino Akihiro Haga Keiichi Nakagawa Kuni Ohtomo 《Reports of Practical Oncology and Radiotherapy》2014,19(5):310-316
Aim
To establish intensity-modulated radiotherapy (IMRT) planning procedures that spare the corticospinal tract by integrating diffusion tensor tractography into the treatment planning software.Background
Organs at risk are generally contoured according to the outline of the organ as demonstrated by CT or MRI. But a part of the organ with specific function is difficult to protect, because such functional part of the organ cannot be delineated on CT or conventional sequence of MRI.Methods
Diagnostic and treatment planning images of glioblastoma patients who had been treated by conventional 3-dimensional conformal radiotherapy were used for re-planning of IMRT. Three-dimensional fiber maps of the corticospinal tracts were created from the diffusion tensors obtained from the patients before the surgery, and were blended with the anatomical MR images (i.e. gadolinium-enhanced T1-weighted images or T2-weighted images). DICOM-formatted blended images were transferred and fused to the planning CT images. Then, IMRT plans were attempted.Results
The corticospinal tracts could be contoured as organs at risk (OARs), because the blended images contained both anatomical information and fiber-tract maps. Other OARs were contoured in a way similar to that of ordinary IMRT planning. Gross tumor volumes, clinical target volumes, planning target volumes, and other OARs were contoured on the treatment planning software, and IMRT plans were made.Conclusions
IMRT plans with diminished doses to the corticospinal tract were attained. This technique enabled us to spare specific neuron fibers as OARs which were formerly “invisible” and to reduce the probability of late morbidities. 相似文献4.
Ching-Ching Yang 《PloS one》2016,11(3)
Purpose
Scatter is a very important artifact causing factor in dental cone-beam CT (CBCT), which has a major influence on the detectability of details within images. This work aimed to improve the image quality of dental CBCT through scatter correction.Methods
Scatter was estimated in the projection domain from the low frequency component of the difference between the raw CBCT projection and the projection obtained by extrapolating the model fitted to the raw projections acquired with 2 different sizes of axial field-of-view (FOV). The function for curve fitting was optimized by using Monte Carlo simulation. To validate the proposed method, an anthropomorphic phantom and a water-filled cylindrical phantom with rod inserts simulating different tissue materials were scanned using 120 kVp, 5 mA and 9-second scanning time covering an axial FOV of 4 cm and 13 cm. The detectability of the CT image was evaluated by calculating the contrast-to-noise ratio (CNR).Results
Beam hardening and cupping artifacts were observed in CBCT images without scatter correction, especially in those acquired with 13 cm FOV. These artifacts were reduced in CBCT images corrected by the proposed method, demonstrating its efficacy on scatter correction. After scatter correction, the image quality of CBCT was improved in terms of target detectability which was quantified as the CNR for rod inserts in the cylindrical phantom.Conclusions
Hopefully the calculations performed in this work can provide a route to reach a high level of diagnostic image quality for CBCT imaging used in oral and maxillofacial structures whilst ensuring patient dose as low as reasonably achievable, which may ultimately make CBCT scan a reliable and safe tool in clinical practice. 相似文献5.
Purpose
To evaluate whether gadoxetic acid (Gd-EOB-DTPA)-enhanced MR images of tumors taken during the hepatocyte-specific phase can aid in the differentiation between hepatocellular carcinoma (HCC) and dysplastic nodules (DNs) in patients with atypical cirrhotic nodules detected on dynamic CT images.Materials and Methods
Seventy-one patients with 112 nodules showing atypical dynamic enhancement on CT images underwent gadoxetic acid-enhanced MR imaging (MRI) studies. Using a reference standard, we determined that 33 of the nodules were DNs and that 79 were true HCCs. Tumor size, signal intensity on precontrast T1-weighted images (T1WI) and T2WI, and the pattern of dynamic enhancement on MR images taken in the hepatocyte-phase were determined.Results
There were significant differences in tumor size, hyperintensity on T2WI, hypointensity on T1WI, typical HCC enhancement pattern on dynamic MR images, or hypointensity on hepatocyte-phase images between DNs and HCC. The sensitivity and specificity were 60.8% and 87.9% for T2WI, 38.0% and 87.9% for T1WI, 17.7% and 100% for dynamic MR imaging, 83.5% and 84.9% for hepatocyte-phase imaging, and 60.8% and 87.9% for tumor size (threshold of 1.7 cm).Conclusion
Gd-EOB-DTPA-enhanced hepatocyte-phase imaging is recommended for patients at high risk of HCC who present with atypical lesions on dynamic CT images. 相似文献6.
Ma?gorzata Wierzbicka Mariola Popko Karolina Piskad?o Rafa? Czepczyński Aleksandra Stankowska Tomasz Pi?tka Miros?aw Dziuk Witold Szyfter 《Reports of Practical Oncology and Radiotherapy》2011,16(5):184-188
Background
Posttreatment surveillance for the local and regional recurrence of the head and neck squamous cell carcinoma often requires a multimodality techniques that include PET combined with CT, MRI, US.Aim
The purpose of this study is to compare the diagnostic performance of two imaging techniques (PET/CT and US), and their combined use for the detection of a subclinical regional recurrence in patients after HNSCC treatment.Materials and methods
83 patients after completion of the HNSCC treatment underwent both US and PET/CT on the mean follow-up of 14 months after initial treatment.Results
The sensitivity and specificity of PET/CT were 86% and 82%, respectively; US values reached 81% and 87%, respectively. PPV was 79% for PET/CT, and 83% for US. NPV was 89% for PET/CT, and 85% for US. The overall accuracy for PET/CT and US was 84% for both methods.Conclusion
US could be regarded as complementary to PET/CT as the procedures with highest sensitivity, specificity and NPV for detecting subclinical regional recurrences after HNSCC treatment. 相似文献7.
Mehmet Ak?akaya Seunghoon Nam Tamer A. Basha Keigo Kawaji Vahid Tarokh Reza Nezafat 《PloS one》2014,9(9)
Background
Non-Cartesian trajectories are used in a variety of fast imaging applications, due to the incoherent image domain artifacts they create when undersampled. While the gridding technique is commonly utilized for reconstruction, the incoherent artifacts may be further removed using compressed sensing (CS). CS reconstruction is typically done using conjugate-gradient (CG) type algorithms, which require gridding and regridding to be performed at every iteration. This leads to a large computational overhead that hinders its applicability.Methods
We sought to develop an alternative method for CS reconstruction that only requires two gridding and one regridding operation in total, irrespective of the number of iterations. This proposed technique is evaluated on phantom images and whole-heart coronary MRI acquired using 3D radial trajectories, and compared to conventional CS reconstruction using CG algorithms in terms of quantitative vessel sharpness, vessel length, computation time, and convergence rate.Results
Both CS reconstructions result in similar vessel length (P = 0.30) and vessel sharpness (P = 0.62). The per-iteration complexity of the proposed technique is approximately 3-fold lower than the conventional CS reconstruction (17.55 vs. 52.48 seconds in C++). Furthermore, for in-vivo datasets, the convergence rate of the proposed technique is faster (60±13 vs. 455±320 iterations) leading to a ∼23-fold reduction in reconstruction time.Conclusions
The proposed reconstruction provides images of similar quality to the conventional CS technique in terms of removing artifacts, but at a much lower computational complexity. 相似文献8.
Wei Xing Xiaozhou He Mohammad A. Kassir Jie Chen Jiule Ding Jun Sun Jiani Hu Zishu Zhang E. Mark Haacke Yongming Dai 《PloS one》2013,8(2)
Background
Intratumoral hemorrhage is a frequent occurrence in renal cell carcinoma and is an indicator of tumor subtype. We hypothesize that susceptibility weighted imaging (SWI) is sensitive to hemorrhage in renal cell carcinoma and can give a more diagnostic image when compared to conventional imaging techniques.Materials and Methods
A retrospective review of 32 patients with clear cell renal cell carcinoma was evaluated. All patients underwent magnetic resonance imaging (MRI) and 22 out of 32 patients also underwent a computed tomography (CT) scan. Hemorrhage was classified into 3 different categories according to shape and distribution. Histopathology was obtained from all masses by radical nephrectomy. The ability to detect the presence of hemorrhage using CT, non-contrast conventional MRI and SWI was evaluated, and the patterns of hemorrhage were compared.Results
Using pathologic results as the gold standard, the sensitivities of non-contrast conventional MRI, SWI and CT in detecting hemorrhage in clear cell renal cell carcinoma were 65.6%, 100% and 22.7%, respectively. Accuracy of non-contrast conventional MRI and SWI in evaluating hemorrhagic patterns were 31.3% and 100%, respectively.Conclusion
These results demonstrate that SWI can better reveal hemorrhage and characterize the pattern more accurately than either non-contrast conventional MRI or CT. This suggests that SWI is the technique of choice for detecting hemorrhagic lesions in patients with renal cancer. 相似文献9.
OM Mets EJ Smit FA Mohamed Hoesein HA Gietema RP Bokkers M Attrach S van Amelsvoort-van de Vorst ET Scholten CF Buckens M Oudkerk JW Lammers M Prokop PA de Jong 《PloS one》2012,7(7):e42227
Background
Incidental CT findings may provide an opportunity for early detection of chronic obstructive pulmonary disease (COPD), which may prove important in CT-based lung cancer screening setting. We aimed to determine the diagnostic performance of human observers to visually evaluate COPD presence on CT images, in comparison to automated evaluation using quantitative CT measures.Methods
This study was approved by the Dutch Ministry of Health and the institutional review board. All participants provided written informed consent. We studied 266 heavy smokers enrolled in a lung cancer screening trial. All subjects underwent volumetric inspiratory and expiratory chest computed tomography (CT). Pulmonary function testing was used as the reference standard for COPD. We evaluated the diagnostic performance of eight observers and one automated model based on quantitative CT measures.Results
The prevalence of COPD in the study population was 44% (118/266), of whom 62% (73/118) had mild disease. The diagnostic accuracy was 74.1% in the automated evaluation, and ranged between 58.3% and 74.3% for the visual evaluation of CT images. The positive predictive value was 74.3% in the automated evaluation, and ranged between 52.9% and 74.7% for the visual evaluation. Interobserver variation was substantial, even within the subgroup of experienced observers. Agreement within observers yielded kappa values between 0.28 and 0.68, regardless of the level of expertise. The agreement between the observers and the automated CT model showed kappa values of 0.12–0.35.Conclusions
Visual evaluation of COPD presence on chest CT images provides at best modest accuracy and is associated with substantial interobserver variation. Automated evaluation of COPD subjects using quantitative CT measures appears superior to visual evaluation by human observers. 相似文献10.
Background
The aim of this retrospective study was to document the clinical findings and radiological features of idiopathic orbital inflammation syndrome with retro-orbital involvement.Methods
We searched for ophthalmological patients who received orbital imaging at Zhejiang Provincial People''s Hospital between October 2003 and April 2010. Seventy-three patients were diagnosed with idiopathic orbital inflammation syndrome based on clinicoradiological features, with pathological confirmation of nonspecific inflammatory conditions in 47 patients. Eight patients (11%) had MRI or CT evidence of retro-orbital involvement. All 8 patients were diagnosed with idiopathic orbital inflammation syndrome after biopsy of the orbital lesion. MR images were obtained for all 8 patients; 3 patients also had a contrast-enhanced CT scan.Results
Seven out of 8 patients with retro-orbital involvement also had orbital apex lesions. Of the 65 patients without retro-orbital involvement, 19 had orbital apex lesions. The difference in the number of patients with orbital apex lesions between the two populations was significant (Fisher exact test P = .002). In all 8 patients with retro-orbital involvement, the inflammation spread through the superior orbital fissure. The retro-orbital lesions were isointense to grey matter on T1-weighted images, hypointense on T2-weighted images, and displayed uniform contrast enhancement; on contrast-enhanced CT scans, they were hyperdense relative to the contralateral mirror area and had radiological contours that were similar to those seen on MR images. The diffuse inflammation with marked sclerosis and hyalinization that we observed in the patients with retro-orbital involvement is consistent with the diagnosis of the sclerosing subtype of idiopathic orbital inflammation syndrome. All 8 patients also complained of mild to moderate periorbital pain (headache).Conclusions
In patients with idiopathic orbital inflammation syndrome, it is important to perform MRI and CT scans to identify possible retro-orbital involvement. Retro-orbital involvement is more frequent when the lesion is present in the orbital apex. 相似文献11.
Introduction
MRI can be used to non-invasively monitor tumour growth and response to treatment in mouse models of prostate cancer, particularly for longitudinal studies of orthotopically-implanted models. We have optimized the balanced steady-state free precession (bSSFP) pulse sequence for mouse prostate imaging.Methods
Phase cycling, excitations, flip angle and receiver bandwidth parameters were optimized for signal to noise ratio and contrast to noise ratio of the prostate. The optimized bSSFP sequence was compared to T1- and T2-weighted spin echo sequences.Results
SNR and CNR increased with flip angle. As bandwidth increased, SNR, CNR and artifacts such as chemical shift decreased. The final optimized sequence was 4 PC, 2 NEX, FA 50°, BW ±62.5 kHz and took 14–26 minutes with 200 µm isotropic resolution. The SNR efficiency of the bSSFP images was higher than for T1WSE and T2WSE. CNR was highest for T1WSE, followed closely by bSSFP, with the T2WSE having the lowest CNR. With the bSSFP images the whole body and organs of interest including renal, iliac, inguinal and popliteal lymph nodes were visible.Conclusion
We were able to obtain fast, high-resolution, high CNR images of the healthy mouse prostate with an optimized bSSFP sequence. 相似文献12.
Jun Zhou Songhua Zhan Qiong Zhu Hangjun Gong Yidong Wang Desheng Fan Zhigang Gong Yanwen Huang 《PloS one》2014,9(4)
Objective
To investigate the accuracy of preoperative computed tomography (CT), magnetic resonance (MR) imaging and diffusion-weighted imaging with background body signal suppression (DWIBS) in the prediction of nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures.Methods and Materials
Fifty-two subjects with primary rectal cancer were preoperatively assessed by CT and MRI at 1.5 T with a phased-array coil. Preoperative lymph node staging with imaging modalities (CT, MRI, and DWIBS) were compared with the final histological findings.Results
The accuracy of CT, MRI, and DWIBS were 57.7%, 63.5%, and 40.4%. The accuracy of DWIBS with higher sensitivity and negative predictive value for evaluating primary rectal cancer patients was lower than that of CT and MRI. Nodal staging agreement between imaging and pathology was fairly strong for CT and MRI (Kappa value = 0.331 and 0.348, P<0.01) but was relatively weaker for DWIBS (Kappa value = 0.174, P<0.05). The accuracy was 57.7% and 59.6%, respectively, for CT and MRI when the lymph node border information was used as the criteria, and was 57.7% and 61.5%, respectively, for enhanced CT and MRI when the lymph node enhancement pattern was used as the criteria.Conclusion
MRI is more accurate than CT in predicting nodal involvement in primary rectal carcinoma patients in the absence of tumor invasion into pelvic structures. DWIBS has a great diagnostic value in differentiating small malignant from benign lymph nodes. 相似文献13.
Tsuneo Yamashiro Tetsuhiro Miyara Osamu Honda Hisashi Kamiya Kiyoshi Murata Yoshiharu Ohno Noriyuki Tomiyama Hiroshi Moriya Mitsuhiro Koyama Satoshi Noma Ayano Kamiya Yuko Tanaka Sadayuki Murayama for the investigators of ACTIve Study Group 《PloS one》2014,9(8)
Objective
To assess the advantages of Adaptive Iterative Dose Reduction using Three Dimensional Processing (AIDR3D) for image quality improvement and dose reduction for chest computed tomography (CT).Methods
Institutional Review Boards approved this study and informed consent was obtained. Eighty-eight subjects underwent chest CT at five institutions using identical scanners and protocols. During a single visit, each subject was scanned using different tube currents: 240, 120, and 60 mA. Scan data were converted to images using AIDR3D and a conventional reconstruction mode (without AIDR3D). Using a 5-point scale from 1 (non-diagnostic) to 5 (excellent), three blinded observers independently evaluated image quality for three lung zones, four patterns of lung disease (nodule/mass, emphysema, bronchiolitis, and diffuse lung disease), and three mediastinal measurements (small structure visibility, streak artifacts, and shoulder artifacts). Differences in these scores were assessed by Scheffe''s test.Results
At each tube current, scans using AIDR3D had higher scores than those without AIDR3D, which were significant for lung zones (p<0.0001) and all mediastinal measurements (p<0.01). For lung diseases, significant improvements with AIDR3D were frequently observed at 120 and 60 mA. Scans with AIDR3D at 120 mA had significantly higher scores than those without AIDR3D at 240 mA for lung zones and mediastinal streak artifacts (p<0.0001), and slightly higher or equal scores for all other measurements. Scans with AIDR3D at 60 mA were also judged superior or equivalent to those without AIDR3D at 120 mA.Conclusion
For chest CT, AIDR3D provides better image quality and can reduce radiation exposure by 50%. 相似文献14.
15.
Hidemi Okuma Wataru Gonoi Masanori Ishida Go Shirota Yukako Shintani Hiroyuki Abe Masashi Fukayama Kuni Ohtomo 《PloS one》2014,9(11)
Objective
We evaluated the postmortem changes of striated muscle by comparing computed tomography (CT) images obtained postmortem and antemortem in the same patients.Materials and Methods
We studied 33 consecutive patients who underwent antemortem CT, postmortem CT, and pathological autopsy in our tertiary care hospital between April 2009 and December 2010. Postmortem CT was performed within 20 h after death and was followed by pathological autopsy. Pathological autopsy confirmed the absence of muscular diseases such as amyotrophic lateral sclerosis, muscular dystrophy, myositis, and myasthenia, in all of the patients. The CT attenuation values of four cardiac muscle sites (anterior wall of the left ventricle, left ventricular free wall, posterior wall of the left ventricle, and the ventricular septum) and two skeletal muscle sites (the pectoralis major muscle and the erector spinae muscle) were compared between antemortem and postmortem CT using paired t test.Results
Striated muscle had significantly greater attenuation on postmortem CT than on antemortem CT (P<0.001) in all six tissue sites. No significant association was found between postmortem change in the CT attenuation of striated muscle and gender, age, or elapsed time since death.Conclusion
This is the first longitudinal study to show hyperattenuation of striated muscle on postmortem CT images compared with antemortem CT images in the same patients. 相似文献16.
Tom van Seeters Geert Jan Biessels Joris M. Niesten Irene C. van der Schaaf Jan Willem Dankbaar Alexander D. Horsch Willem P. T. M. Mali L. Jaap Kappelle Yolanda van der Graaf Birgitta K. Velthuis 《PloS one》2013,8(10)
Background and Purpose
Good reliability of methods to assess the extent of ischemia in acute stroke is important for implementation in clinical practice, especially between observers with varying experience. Our aim was to determine inter- and intra-observer reliability of the 1/3 middle cerebral artery (MCA) rule and the Alberta Stroke Program Early CT Score (ASPECTS) for different CT modalities in patients suspected of acute ischemic stroke.Methods
We prospectively included 105 patients with acute neurological deficit due to suspected acute ischemic stroke within 9 hours after symptom onset. All patients underwent non-contrast CT, CT perfusion and CT angiography on admission. All images were evaluated twice for presence of ischemia, ischemia with >1/3 MCA involvement, and ASPECTS. Four observers evaluated twenty scans twice for intra-observer agreement. We used kappa statistics and intraclass correlation coefficient to calculate agreement.Results
Inter-observer agreement for the 1/3 MCA rule and ASPECTS was fair to good for non-contrast CT, poor to good for CT angiography source images, but excellent for all CT perfusion maps (cerebral blood volume, mean transit time, and predicted penumbra and infarct maps). Intra-observer agreement for the 1/3 MCA rule and ASPECTS was poor to good for non-contrast CT, fair to moderate for CT angiography source images, and good to excellent for all CT perfusion maps.Conclusion
Between observers with a different level of experience, agreement on the radiological diagnosis of cerebral ischemia is much better for CT perfusion than for non-contrast CT and CT angiography source images, and therefore CT perfusion is a very reliable addition to standard stroke imaging. 相似文献17.
Purpose
The aim of this study was to develop a robust post-processing workflow for motion-corrupted datasets in diffusion kurtosis imaging (DKI).Materials and methods
The proposed workflow consisted of brain extraction, rigid registration, distortion correction, artifacts rejection, spatial smoothing and tensor estimation. Rigid registration was utilized to correct misalignments. Motion artifacts were rejected by using local Pearson correlation coefficient (LPCC). The performance of LPCC in characterizing relative differences between artifacts and artifact-free images was compared with that of the conventional correlation coefficient in 10 randomly selected DKI datasets. The influence of rejected artifacts with information of gradient directions and b values for the parameter estimation was investigated by using mean square error (MSE). The variance of noise was used as the criterion for MSEs. The clinical practicality of the proposed workflow was evaluated by the image quality and measurements in regions of interest on 36 DKI datasets, including 18 artifact-free (18 pediatric subjects) and 18 motion-corrupted datasets (15 pediatric subjects and 3 essential tremor patients).Results
The relative difference between artifacts and artifact-free images calculated by LPCC was larger than that of the conventional correlation coefficient (p<0.05). It indicated that LPCC was more sensitive in detecting motion artifacts. MSEs of all derived parameters from the reserved data after the artifacts rejection were smaller than the variance of the noise. It suggested that influence of rejected artifacts was less than influence of noise on the precision of derived parameters. The proposed workflow improved the image quality and reduced the measurement biases significantly on motion-corrupted datasets (p<0.05).Conclusion
The proposed post-processing workflow was reliable to improve the image quality and the measurement precision of the derived parameters on motion-corrupted DKI datasets. The workflow provided an effective post-processing method for clinical applications of DKI in subjects with involuntary movements. 相似文献18.
Yan Bai Mei-Yun Wang Yan-Hong Han She-Wei Dou Qing Lin Ying Guo Wei Li De-Gang Ding Jian-Ping Dai Wei Qin Da-Peng Shi Jie Tian Yong-Ming Dai 《PloS one》2013,8(1)
Background
Susceptibility weighted imaging (SWI) is a new MRI technique which has been proved very useful in the diagnosis of brain diseases, but few study was performed on its value in prostatic diseases. The aim of the present study was to investigate the value of SWI in distinguishing prostate cancer from benign prostatic hyperplasia and detecting prostatic calcification.Methodology/Principal Findings
23 patients with prostate cancer and 53 patients with benign prostatic hyperplasia proved by prostate biopsy were scanned on a 3.0T MR and a 16-row CT scanner. High-resolution SWI, conventional MRI and CT were performed on all patients. The MRI and CT findings, especially SWI, were analyzed and compared. The analyses revealed that 19 out of 23 patients with prostate cancer presented hemorrhage within tumor area on SWI. However, in 53 patients with benign prostatic hyperplasia, hemorrhage was detected only in 1 patient in prostate by SWI. When comparing SWI, conventional MRI and CT in detecting prostate cancer hemorrhage, out of the 19 patients with prostate cancer who had prostatic hemorrhage detected by SWI, the prostatic hemorrhage was detected in only 7 patients by using conventional MRI, and none was detected by CT. In addition, CT demonstrated calcifications in 22 patients which were all detected by SWI whereas only 3 were detected by conventional MRI. Compared to CT, SWI showed 100% in the diagnostic sensitivity, specificity, accuracy, positive predictive value(PPV) and negative predictive value(NPV) in detecting calcifications in prostate but conventional MRI demonstrated 13.6% in sensitivity, 100% in specificity, 75% in accuracy, 100% in PPV and 74% in NPV.Conclusions
More apparent prostate hemorrhages were detected on SWI than on conventional MRI or CT. SWI may provide valuable information for the differential diagnosis between prostate cancer and prostatic hyperplasia. Filtered phase images can identify prostatic calcifications as well as CT. 相似文献19.
Haotong Xu Xiaoming Zhang Andreas Christe Lukas Ebner Shaoxiang Zhang Zhulin Luo Yi Wu Yin Li Fuzhou Tian 《PloS one》2013,8(4)
Background
In past reports, researchers have seldom attached importance to achievements in transforming digital anatomy to radiological diagnosis. However, investigators have been able to illustrate communication relationships in the retroperitoneal space by drawing potential routes in computerized tomography (CT) images or a virtual anatomical atlas. We established a new imaging anatomy research method for comparisons of the communication relationships of the retroperitoneal space in combination with the Visible Human Project and CT images. Specifically, the anatomic pathways of peripancreatic fluid extension to the mediastinum that may potentially transform into fistulas were studied.Methods
We explored potential pathways to the mediastinum based on American and Chinese Visible Human Project datasets. These drainage pathways to the mediastinum were confirmed or corrected in CT images of 51 patients with recurrent acute pancreatitis in 2011. We also investigated whether additional routes to the mediastinum were displayed in CT images that were not in Visible Human Project images.Principal Findings
All hypothesized routes to the mediastinum displayed in Visible Human Project images, except for routes from the retromesenteric plane to the bilateral retrorenal plane across the bilateral fascial trifurcation and further to the retrocrural space via the aortic hiatus, were confirmed in CT images. In addition, route 13 via the narrow space between the left costal and crural diaphragm into the retrocrural space was demonstrated for the first time in CT images.Conclusion
This type of exploration model related to imaging anatomy may be used to support research on the communication relationships of abdominal spaces, mediastinal spaces, cervical fascial spaces and other areas of the body. 相似文献20.
Lei Shi Fuhua Yan Zilai Pan Bo Liu Huanhuan Liu Baisong Wang Huan Zhang Yingyan Yu 《PloS one》2014,9(11)