首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
1 high performance liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed to measure the thymosin alpha 1 (Tα1) concentration in human serum. Tα1 in human serum was determined by solid phase extraction and reverse phase LC-MS/MS. The high-performance liquid chromatography (HPLC) system interfaced with the MS/MS system with a Turbo Ion spray interface. Positive ion detection and multiple reaction monitoring (MRM) mode were used for this human serum quantitation. Eight different concentration standards were used to establish the detection range. Six quality control (QC) and 2 matrix blanks were checked by calibration curves performed on the same day. The lower quantitation limit was 0.5 ng/mL T α1 in human serum. Calibration curves were established between 0.5 to 100 ng/mL by weighted linear regression. The correlation coefficients for different days were 0.9955 or greater. Quantitation of Tα1 by the LC-MS/MS method is fast accurate, and precise.  相似文献   

2.
Sensitive and selective methods based on high performance liquid chromatography (HPLC) with tandem mass spectrometric (MS/MS) detection were developed for the determination of vitamin D(3) in human serum. Derivatization of vitamin D(3) and its stable isotope labeled internal standard provided highly sensitive quantification and selective detection from endogenous compounds. Samples were prepared using the in-tube liquid-liquid extraction (LLE), 96-well plate LLE, and in-tip solid phase micro-extraction (SPME) in 96-well format. In all methods, the MS/MS detection was performed using Applied Biosystems-Sciex API 3000 tandem mass spectrometers interfaced with a heated nebulizer probe and operated in the positive ionization mode. Both tube and plate LLE methods achieved a lower limit of quantitation (LLOQ) of 0.5 ng/mL when 1.0 and 0.4 mL of human serum was processed, respectively, and were validated in the concentration range of 0.5-25 ng/mL; while for the in-tip SPME method, LLOQ was 5 ng/mL with only 0.1 mL of human serum required. Comparisons were made among three different methods, including precision and accuracy, sample throughput, recovery and matrix effects.  相似文献   

3.
Introduction – Biflavones of Hypericum perforatum L. are bioactive compounds used in the treatment of inflammation and depression. Determination of amentoflavone and biapigenin from blood is challenging owing to their similar structures and low concentrations. Objective – To develop a rapid, sensitive and accurate method based on liquid‐phase extraction followed by high‐performance liquid chromatography and electrospray ionisation mass spectrometry (HPLC‐ESI‐MS) for quantification of biflavones in human plasma. Methodology – After extraction from blood, the analytes were subjected to HPLC with an XTerra® MS C18 column and a binary mobile phase consisting of 2% formic acid in water and acetonitrile under isocratic elution conditions, with ESI‐MS detection in the negative ion mode and multiple reaction monitoring (MRM). Results – Both calibration curves showed good linearity within the concentration range 1–500 ng/mL. Limits of detection (S/N = 3) were 0.1 ng for pure substances and the limits of quantitation (S/N = 5) were 1.0 ng/mL from analyte‐spiked serum. The grand mean recovery was 90% from several subsamples of each biflavone. The imprecision (RSD) of peak areas was between 5% (intraday) and 10% (interday) for high concentrations (250 ng/mL) and between 10% (intraday) and 15% (interday) for low concentrations (1 ng/mL). Inaccuracy of the mean was less than 20% at the lower limit of quantitation. Conclusion – The developed and validated method for determination of biflavones from human plasma was effectively applied to pharmacokinetic studies of 13 probands and preliminary results indicate biphasic concentration–time curves. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

4.
Polylactic acid (PLA) is a biodegradable polymer, currently used in pharmaceutical and surgical devices. There is a concern that cyclic polylactic acid (CPLA), which is a by-product of PLA synthesis, may be introduced into the human body as an undesirable contaminant. We carried out a quantitation investigation of the CPLA heptamer (CPLA-7) by liquid chromatography mass spectrometry (LC-MS). We found that CPLA-7 binds strongly with serum proteins and that only 62% of CPLA-7 was recovered after routine deproteination; therefore, we directly injected serum into the LC-MS/MS system after passage through a bovine serum albumin (BSA)-coated chromatographic column and found the recovery of CPLA-7 was improved to 84%, and that the detection (S/N=3) and quantitation limit (S/N=10 and below 15% relative standard deviation) were 1.5 and 2.5 ng/mL, respectively. We conclude that direct injection LC-MS/MS, using a BSA column, is a simple and effective quantitative analysis method for CPLA in serum.  相似文献   

5.
A reversed-phased liquid chromatography with tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantitation of the total and unbound RO4929097, a γ-secretase inhibitor targeting Notch signaling, in human plasma. Sample preparation involved a liquid-liquid extraction with ethyl acetate. Chromatographic separation was achieved on a Waters X-Terra? MS C(18) column with an isocratic mobile phase consisting of methanol/0.45% formic acid in water (60:40, v/v) running at a flow rate of 0.2 ml/min for 6 min. The lower limits of quantitation (LLOQs) were 5 ng/ml for the total RO4929097 in plasma and 0.5 ng/ml for the unbound drug in phosphate buffer solution (PBS). Calibration curves were linear over RO4929097 concentration range of 5-2000 ng/ml in plasma for the total drug and 0.5-200 ng/ml in PBS for the unbound drug. The intra-day and inter-day accuracy and precision were within the generally accepted criteria for bioanalytical method (<15%). The method has been successfully employed to characterize the total and unbound plasma pharmacokinetics of RO4929097 after its oral administration in cancer patients.  相似文献   

6.
We have developed and validated a simple and sensitive stable isotope dilution liquid chromatography/tandem mass spectrometric (LC-MS/MS) method for the quantification of bumetanide in human serum. Samples were prepared with a simple acetonitrile based protein precipitation. The supernatant was then analyzed directly using LC-MS/MS. Chromatographic separation was achieved on a C18 reversed phase column using a methanol and water gradient. The detection was performed in selected reaction monitoring (SRM) mode via a positive electrospray ionization (ESI) interface. The method had a lower limit of quantification (LLOQ) of 1 ng/mL, linearity up to 1250 ng/mL, intra- and inter-day precision less than 10%, and accuracy within ±10%. This method was also demonstrated to be suitable for the analysis of bumetanide in rat serum and brain tissue. Bumetanide concentrations in rat serum and brain were determined for samples collected at several intervals following intraperitoneal (i.p.) injection of bumetanide, and were used to calculate bumetanide permeability through the blood-brain barrier.  相似文献   

7.
To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm x 2.1 mm, i.d., 3 microm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05-400 ng/mL for 1 and 0.1-400 ng/mL for 2 on a PE Sciex API 4000 LC-MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1-104.6% of nominal for 1 standards and 93.5-105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at -70 degrees C for 10 days, and after three freeze-thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.  相似文献   

8.
A reverse-phase high performance liquid chromatographic method with tandem mass spectrometry (LC-MS/MS) was developed and validated for the quantitation of ON 01910.Na, a novel synthetic benzyl styryl sulfone, in human plasma. The assay involved a simple sample preparation with acetonitrile protein precipitation. ON 01910.Na and the internal standard temazepam were separated on a Waters X-Terra MS C(18) column with mobile phase of acetonitrile containing 0.1% formic acid /10mM ammonium acetate (55:45, v/v) using isocratic flow at 0.2 mL/min for 5 min. The analytes were monitored by tandem-mass spectrometry with electrospray positive ionization. Two calibration curves were generated over the range of 10-2000 ng/mL and 100-20000 ng/mL. The lower limit of quantitation (LLOQ) was 10 ng/mL for ON 01910.Na in human plasma. The accuracy and within- and between-day precisions were within the acceptance criteria for bioanalytical assays. ON 01910.Na was found stable in plasma at -70 degrees C for at least 1 year. The method was successfully applied to characterize the plasma concentration-time profiles of ON 01910.Na in the cancer patients in the Phase I study.  相似文献   

9.
A rapid equilibrium dialysis (RED) assay followed by a solid phase extraction (SPE) high-performance liquid chromatography tandem mass spectrometry (LC-MS/MS) assay for the quantitative determination of unbound vismodegib in human plasma was developed and validated. The equilibrium dialysis was carried out using 0.3 mL plasma samples in the single-use plate RED system at 37°C for 6h. The dialysis samples (0.1 mL) were extracted using a Strata-X-C 33u Polymeric Strong Cation SPE plate and the resulting extracts were analyzed using reverse-phase chromatography and positive electrospray ionization (ESI) mass spectrometry. The standard curve, which ranged from 0.100 to 100 ng/mL for vismodegib, was fitted to a 1/x(2) weighted linear regression model. The lower limit of quantitation (LLOQ, 0.100 ng/mL) was sufficient to quantify unbound concentrations of vismodegib after dialysis. The intra-assay precision of the LC-MS/MS assay, based on the four analytical QC levels (LLOQ, low, medium and high), was within 7.7% CV and inter-assay precision was within 5.5% CV. The assay accuracy, expressed as %Bias, was within ±4.0% of the nominal concentration values. Extraction recovery of vismodegib was between 77.9 and 84.0%. The assay provides a means for accurate assessment of unbound vismodegib plasma concentrations in clinical studies.  相似文献   

10.
A sensitive method using liquid chromatography with tandem mass spectrometric detection (LC-MS/MS) was developed and validated for the analysis of antihistamine drug azatadine in human plasma. Loratadine was used as internal standard (IS). Analytes were extracted from human plasma by liquid/liquid extraction using ethyl acetate. The organic phase was reduced to dryness under a stream of nitrogen at 30 °C and the residue was reconstituted with the mobile phase. 5 μL of the resulting solution was injected onto the LC-MS/MS system. A 4.6 mm × 150 mm, I.D. 5 μm, Agilent TC-C(18) column was used to perform the chromatographic analysis. The mobile phase consisted of ammonium formate buffer 0.010 M (adjusted to pH 4.3 with 1M formic acid)/acetonitrile (20:80, v/v) The chromatographic run time was 5 min per injection and flow rate was 0.6 mL/min. The retention time was 2.4 and 4.4 min for azatadine and IS, respectively. The tandem mass spectrometric detection mode was achieved with electrospray ionization (ESI) iron source and the multiple reaction monitoring (MRM) (291.3 → 248.2m/z for azatadine, 383.3 → 337.3m/z for IS) was operated in positive ion modes. The low limit of quantitation (LLOQ) was 0.05 ng/mL. The intra-day and inter-day precision of the quality control (QC) samples was 8.93-11.57% relative standard deviation (RSD). The inter-day accuracy of the QC samples was 96.83-105.07% of the nominal values.  相似文献   

11.
A rapid and sensitive liquid chromatography/tandem mass spectrometry (LC-MS/MS) method has been developed and fully validated to determine HS270, a new histone deacetylase (HDAC) inhibitor, in rat plasma using SAHA as the internal standard (IS). After a single step liquid-liquid extraction with acetoacetate, analytes were subjected to LC-MS/MS analysis using positive electro-spray ionization (ESI(+)) under selected reaction monitoring mode (SRM). The chromatographic separation was achieved on a Hypurity C(18) column (50 mm × 2.1 mm, i.d., 5 μm). The MS/MS detection was conducted by monitoring the fragmentation of m/z 392.3→100.1 for HS270, m/z 265.1→232.1 for IS. The method had a chromatographic running time of 2.5 min and linear calibration curves over the concentrations of 0.5-1000 ng/mL. The recovery of the method was 70.8-82.5% and the lower limit of quanti?cation (LLOQ) was 0.5 ng/mL. The intra- and inter-batch precisions were less than 15% for all quality control samples at concentrations of 1.0, 100.0, and 750.0 ng/mL. The validated LC-MS/MS method has successfully applied to a HS270 pharmacokinetic study after oral doses of 25, 50, 100, 200 mg/kg, and i.v. dose of 5 mg/kg to rats.  相似文献   

12.
A selective and sensitive method for analysis of perfluorooctanoic acid (PFOA) in human serum and plasma, utilizing liquid chromatography tandem mass spectrometry (LC-MS/MS), has been developed and thoroughly validated to satisfy strict FDA guidelines for bioanalytical methods. A simple, automated sample preparation procedure, involving extraction of the target analyte with acetonitrile on protein precipitation media in a 96-well plate format was developed, allowing efficient handling of large numbers of samples. The proposed method uses the calibration standards prepared in a surrogate matrix (rabbit serum or plasma) and (13)C-labeled PFOA as the internal standard to account for matrix effects, instrument drift, and extraction efficiency. Human serum and plasma could not be used for matrix matching of calibration standards as endogenous levels of PFOA observed in the control human serum and plasma significantly exceeded the targeted lower limit of quantitation (LLOQ) of the method. Precision and accuracy of the method were demonstrated by analysis of rabbit serum and plasma control samples fortified at 0.5, 5, and 40 ng/mL PFOA and human serum and plasma fortified at 1.0, 5.0, 40 ng/mL PFOA. The LLOQ of 0.5 ng/mL PFOA was experimentally demonstrated for rabbit and human serum and plasma. Within-day precision and accuracy, short-term stability, freeze-thaw stability, equivalence of response between PFOA and APFO (the ammonium salt of PFOA), and dilution of concentrated samples were also investigated. The results of the validation experiments comply with the precision and accuracy limits defined by the FDA guidance document: "Guidance for Industry, Bioanalytical Method Validation", May 2001.  相似文献   

13.
A highly sensitive and ultra-fast high performance liquid chromatography- tandem mass spectrometry (LC–MS/MS) assay is developed and validated for the quantification of Lenalidomide in human plasma. Lenalidomide is extracted from human plasma by Liquid- Liquid Extraction by Ethyl Acetate and analyzed using a reversed phase isocratic elution on a XTerra RP18, (4.6 × 50 mM, 5 µm) column. A 0.1% Formic acid: Methanol (10:90% v/v), is used as mobile phase and detection was performed by Triple quadrupole mass spectrometry LC-MS/MS using electrospray ionization in positive mode. Fluconazole is used as the internal standard. The lower limit of quantification is 9.999 ng/mL for Lenalidomide. The calibration curves are consistently accurate and precise over the concentration range of 9.999 to 1010.011 ng/mL in plasma for Lenalidomide. This novel LC–MS/MS method competes with all the regulatory requirements and shows satisfactory accuracy and precision and is sufficiently sensitive for the performance of pharmacokinetic and bioequivalence studies in humans.  相似文献   

14.
19-Norandrosterone sulfate (19-NAS) is the sulfoconjugated form of 19-norandrosterone (19-NA), the major metabolite of the steroid nandrolone. A sensitive and accurate liquid chromatography/tandem mass spectrometry (LC-MS/MS) assay was developed for the direct measurement of 19-NAS in human urine samples. The method involved a quaternary amine SPE protocol and subsequently injection of the extract onto an analytical column (Uptisphere ODB, 150 mm x 3.0 mm, 5 microm) for chromatographic separation and mass spectrometry detection in negative electrospray ionisation mode. The sulfoconjugate of 19-NA was identified in urine by comparison of mass spectra and retention time with a reference substance. The limit of detection (LOD) and lowest limit of quantification (LLOQ) of 19-NAS were of 40 pg/mL and 200 pg/mL, respectively. For a nominal concentration of 2 ng/mL, recovery (94%), intra-day precision (2.7%), intra-assay precision (6.6%) and inter-assay precision (14.3%) were determined. Finally, this analytical method was applied for quantifying the concentration of 19-NAS in doping samples, using calibration curves (0.2-20 ng/mL) and the standard-addition method. The results show the feasibility of applying this LC-MS/MS assay as a complementary tool to detect misuse of nandrolone or nandrolone precursors.  相似文献   

15.
An ultra sensitive method for the direct measurement of 9-(2-phosphonylmethoxyethyl)adenine (PMEA), an antiviral agent for hepatitis B, in human serum using high performance liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed. This method involves the addition of [13C]PMEA (contains 5 13C) as internal standard, the purification and enrichment by a MCX solid phase extraction (SPE) cartridge, and quantitative analysis using LC-MS/MS. The MS/MS is selected to monitor the m/z 272 --> 134 and m/z 277 --> m/z 139 transitions for PMEA and [13C]PMEA, respectively, using negative electrospray ionization. The MS/MS response is linear over a concentration of 0.1-10 ng/ml with a lower limit of quantitation (LLOQ) of 0.1 ng/ml. The mean inter-assay accuracy (%Bias) for quality control (QC) at 0.1, 0.25, 1.0, and 10 ng/ml are 10, 1.6, -0.8, and 0.0%, respectively. The mean inter-assay precision (%CV) for the corresponding QCs is 3.9, 3.8, 5.3, and 3.4%, respectively. The method has been used to determine PMEA concentration in human serum following a single oral administration of a PMEA pro-drug at dose of 10 and 30 mg.  相似文献   

16.
Dihydroartemisinin (DHA) is a sesquiterpene used in the world as an antimalarial. To evaluate the pharmacokinetics of dihydroartemisinin in rats, a sensitive and specific liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for the quantitation of dihydroartemisinin in rat plasma. For detection, a Sciex API 4000 LC-MS/MS with a TurboIonSpray ionization (ESI) inlet in the positive ion-multiple reaction monitoring (MRM) mode was used. The plasma samples were pre-treated by a simple liquid-liquid extraction with diethyl ether. The statistical evaluation for this method reveals excellent linearity, accuracy and precision for the range of concentrations 0.2-100.0 ng/mL. The method had a lower limit of quantification (LLOQ) of 0.2 ng/mL for beta-dihydroartemisinin in 100 microL of plasma. The method was successfully applied to the characterization of the pharmacokinetic profile of beta-dihydroartemisinin in rats after oral administration.  相似文献   

17.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

18.
A sensitive and selective high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was developed for the determination of buagafuran in human plasma. The analyte was extracted from plasma samples with hexane after addition of isotopic internal standard and chromatographed on a RP-C(8) column. The mobile phase consisted of methanol-water (90:10, v/v) and the flow rate was 0.2 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer in multiple reactions monitoring (MRM) mode using positive electrospray ionization (ESI). The method was validated over the concentration range of 0.5-200 ng/mL. Inter- and intra-day precision (RSD%) were all within 15% and the accuracy (RE%) was equal or lower than 9.5%. The lower limit of quantitation (LLOQ) was 0.5 ng/mL. The extraction recovery was on average 38.1% and the detection was not affected by the matrix. The method was successfully applied to the pharmacokinetic study of buagafuran in healthy Chinese volunteers.  相似文献   

19.
A reverse-phase liquid chromatography coupled to tandem mass spectrometry (LC–MS/MS) method was developed and validated for determination of aminoflavone (AF) in human plasma. Sample preparation involved a liquid–liquid extraction by the addition of 0.25 mL of plasma with 1.0 mL ethyl acetate containing 50 ng/mL of the internal standard zileuton. The analytes were separated on a Waters X-Terra? MS C18 column using a mobile phase consisting of methanol/water containing 0.45% formic acid (70:30, v/v) and isocratic flow at 0.2 mL/min for 6 min. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the AF concentration range of 5–2000 ng/mL in human plasma. The lower limit of quantitation (LLOQ) was 5 ng/mL for AF in human plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical method (<15%). This method was successfully applied to characterize AF plasma concentration-time profile in the cancer patients in a phase I trial.  相似文献   

20.
Quantitation of progesterone (P4) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P4 in plasma of cattle with no sample derivatization. The quantitation of plasma P4 released from three nonbiodegradable, commercial, intravaginal P4-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P4 kinetics (P > 0.05) whereas results of P4 quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P4 limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P4 quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏