首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Comprehensive proteome profiling of breast cancer tissue samples is challenging, as the tissue samples contain many proteins with varying concentrations and modifications. We report an effective sample preparation strategy combined with liquid chromatography (LC) electrospray ionization (ESI) quadrupole time-of-flight (QTOF) MS/MS for proteome analysis of human breast cancer tissue. The complexity of the breast cancer tissue proteome was reduced by using protein precipitation from a tissue extract, followed by sequential protein solubilization in solvents of different solubilizing strength. The individual fractions of protein mixtures or subproteomes were subjected to trypsin digestion and the resultant peptides were separated by strong cation exchange (SCX) chromatography, followed by reversed-phase capillary LC combined with high resolution and high accuracy ESI-QTOF MS/MS. This approach identified 14407 unique peptides from 3749 different proteins based on peptide matches with scores above the threshold scores at the 95% confidence level in MASCOT database search of the acquired MS/MS spectra. The false positive rate of peptide matches was determined to be 0.95% by using the target-decoy sequence search strategy. On the basis of gene ontology categorization, the identified proteins represented a wide variety of biological functions, cellular processes, and cellular locations.  相似文献   

2.
Gong Y  Li X  Yang B  Ying W  Li D  Zhang Y  Dai S  Cai Y  Wang J  He F  Qian X 《Journal of proteome research》2006,5(6):1379-1387
Plasma proteins may often serve as indicators of disease and are a rich source for biomarker discovery. However, the intrinsic large dynamic range of plasma proteins makes the analysis very challenging because a large number of low abundance proteins are often masked by a few high abundance proteins. The use of prefractionation methods, such as depletion of higher abundance proteins before protein profiling, can assist in the discovery and detection of less abundant proteins that may ultimately prove to be informative biomarkers. But there are few studies on comprehensive investigation of the proteins both in the fractions depleted and remainder. In the present study, two different immunoaffinity fractionation columns for the top-6 or the top-12 proteins in plasma were investigated and both the proteins in column-bound and flow-through fractions were subsequently analyzed. A two-dimensional peptide separation strategy, utilizing chromatographic separation techniques, combined with tandem mass spectrometry (MS/MS) was employed for proteomic analysis of the four fractions. Using the established HUPO PPP criteria, a total of 2401 unique plasma proteins were identified. The Multiple Affinity Removal System yielded 921 and 725 unique proteins from the flow-through and bound fractions, respectively, whereas the Seppro MIXED 12 column yielded identification of 897 and 730 unique proteins from the flow-through and bound fractions, respectively. When more stringent criteria, based on searching against the reversed database, were implemented, 529 unique proteins were identified from the four fractions with the confidence in peptide identification increased from 73.6% to 99%. To determine whether the presence of nontarget proteins in the immunoaffinity-bound fraction could be attributed to their interaction with high abundance proteins, co-immunoprecipitation analysis with an antibody to human plasma albumin was performed, which resulted in an identification of 40 unique proteins from the coimmunoprecipitate with the more stringent criteria. This study illustrated that combining the column-bound and flow-through fractions from immunoaffinity separation affords more extensive profiling of the protein content of human plasma. The presence of nontarget proteins in the column-bound fractions may be induced by their binding to the higher abundance proteins targeted by the immunoaffinity column.  相似文献   

3.
We describe and demonstrate a global strategy that extends the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements based upon the use of peptide "accurate mass tags" (AMTs) produced by global protein enzymatic digestion. The two-stage strategy exploits Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry to validate peptide AMTs for a specific organism, tissue or cell type from "potential mass tags" identified using conventional tandem mass spectrometry (MS/MS) methods, providing greater confidence in identifications as well as the basis for subsequent measurements without the need for MS/MS, and thus with greater sensitivity and increased throughput. A single high resolution capillary liquid chromatography separation combined with high sensitivity, high resolution and accurate FT-ICR measurements has been shown capable of characterizing peptide mixtures of significantly more than 10(5) components with mass accuracies of < 1 ppm, sufficient for broad protein identification using AMTs. Other attractions of the approach include the broad and relatively unbiased proteome coverage, the capability for exploiting stable isotope labeling methods to realize high precision for relative protein abundance measurements, and the projected potential for study of mammalian proteomes when combined with additional sample fractionation. Using this strategy, in our first application we have been able to identify AMTs for >60% of the potentially expressed proteins in the organism Deinococcus radiodurans.  相似文献   

4.
A versatile, multidimensional, and non-denaturing proteome separation procedure using microplate technology is presented, yielding a digitized image of proteome composition. In the first dimension, the sample under study is separated into 96 fractions by size exclusion chromatography (SEC). In the second dimension, the fractions of the first dimension are transferred by the liquid-handling device CyBi-Well (CyBio AG, Jena, Germany) to 96 parallel anion exchange chromatography columns. In this way the proteins are conserved in their native states and are distributed in 2400 liquid fractions with high recovery rates and sufficient reproducibility. The resulting fractions are subjected to protein quantitation and identification. Spectrophotometrical and immunological methods and enzyme activity measurements are used for quantitation. To identify proteins, the fractions are subjected to MALDI-MS, and their tryptic digests to both MALDI- and LC-ESI-MS/MS. All preparation steps except the first are applied in parallel to sets of multiples of 96 samples. The procedure may be refined by adding more separation steps and may be adapted to various protein amounts and to various proteomes. Moreover, the method offers the opportunity to investigate functional protein complexes. The method was applied to separate the normal human serum proteome. Within 255 fractions exhibiting the highest protein concentrations, 742 proteins were identified by LC-ESI-MS/MS peptide sequence tags.  相似文献   

5.
Kim JY  Lee JH  Park GW  Cho K  Kwon KH  Park YM  Cho SY  Paik YK  Yoo JS 《Proteomics》2005,5(13):3376-3385
The proteome of a HUPO human serum reference sample was analyzed using multidimensional separation techniques at both the protein and the peptide levels. To eliminate false-positive identifications from the search results, we employed a data filtering method using molecular weight (MW) correlations derived from denaturing 1-DE. First, the six most abundant serum proteins were removed from the sample using immunoaffinity chromatography. 1-DE was then used to fractionate the remaining serum proteins according to the MW. Gel bands were isolated and in-gel digested with trypsin, and the resulting peptides were analyzed by 2-D LC/ESI-MS/MS. A SEQUEST search using the MS/MS results identified 494 proteins. Of these, 202 were excluded formally using protein data filtering as they were single-assignment proteins and their theoretical and electrophoretically-derived MWs did not correlate at high confidence. To evaluate this method, the results were compared with those of 1-D LC/MALDI-TOF/TOF and HUPO Plasma Proteome Project analyses. Our data filtering approach proved valuable in analysis of complex, large-scale proteomes such as human serum.  相似文献   

6.
A resurgence of interest in the human plasma proteome has occurred in recent years because it holds great promise of revolution in disease diagnosis and therapeutic monitoring. As one of the most powerful separation techniques, multidimensional liquid chromatography has attracted extensive attention, but most published works have focused on the fractionation of tryptic peptides. In this study, proteins from human plasma were prefractionated by online sequential strong cation exchange chromatography and reversed-phase chromatography. The resulting 30 samples were individually digested by trypsin, and analyzed by capillary reversed-phase liquid chromatography coupled with linear ion trap mass spectrometry. After meeting stringent criteria, a total of 1292 distinct proteins were successfully identified in our work, among which, some proteins known to be present in serum in <10 ng/mL were detected. Compared with other works in published literatures, this analysis offered a more full-scale list of the plasma proteome. Considering our strategy allows high throughput of protein identification in serum, the prefractionation of proteins before MS analysis is a simple and effective method to facilitate human plasma proteome research.  相似文献   

7.
Due to the complexity of proteomes, developing methods of sample fractionation, separation, concentration, and detection have become urgent to the identification of large numbers of proteins, as well as the acquisition of those proteins in low abundance. In this work, liquid isoelectric focusing (LIEF) combined with 2D-LC-MS/MS was applied to the proteome of Saccharomyces cerevisiae. This yielded a total of 1795 proteins that were detected and identified by 30 fractions of protein prefractionation. Categorization of these hits demonstrated the ability of this technology to detect and identify proteins rarely seen in proteome analysis without protein fractionation. LIEF-2D-LC-MS/MS also produced improved resolution of low-abundance proteins. Furthermore, we analyzed the characteristics of proteins obtained by LIEF-2D-LC-MS/MS. 1103 proteins with CAI under 0.2 were identified, allowing us to specifically obtain detailed biochemical information on these kind proteins. It was observed that LIEF-2D-LC-MS/MS is useful for large-scale proteome analysis and may be specifically applied to systems with wide dynamic ranges.  相似文献   

8.
Analysis of human liver proteome using replicate shotgun strategy   总被引:4,自引:0,他引:4  
Chen M  Ying W  Song Y  Liu X  Yang B  Wu S  Jiang Y  Cai Y  He F  Qian X 《Proteomics》2007,7(14):2479-2488
In this study, a liquid-based shotgun strategy was used to comprehensively identify the expression of human liver proteome. Proteins were extracted from human liver tissue and digested in-solution. The tryptic digest mixture was desalted and separated by off-line strong cation exchange (SCX) chromatography with a 60-min elution. The MS/MS spectra were acquired in data-dependent mode after an RP chromatographic separation combined with linear IT MS analysis. To obtain the most comprehensive human liver proteome, each SCX fraction was run six times in RPLC MS/MS manner. Finally, more than 6,000,000 MS/MS spectra were collected. Using a relatively strict filter criteria, 24,311 proteins (48.42% of the predicted human proteome from human International Protein Index (IPI) protein database 3.07) corresponding to 13,150 nonredundant proteins were successfully identified, in which 7001 proteins (53.24%) were identified by two or more peptides, which could be considered as a high-confident dataset. Among the 6149 proteins (46.76%) identified by single peptide, 3812 proteins (61.99%) were detected more than twice in six repeated runs. Comparative analysis between different runs shows that the overlap of identified proteins between any two runs ranged from 25 to 44%. Of the nonredundant proteins identified, 8919 proteins (67.83%) were detected more than twice and 4231 proteins (32.17%) were detected only once in six RPLC MS/MS runs. The Gene Ontology annotation shows that the identified proteins come from various subcellular components. In addition, a large number of low abundant proteins were identified. The dynamic range of the approach reached at least nine orders of magnitude by estimating the concentration of proteins.  相似文献   

9.
Reversed-phase liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) allows analysis of very complex peptide mixtures at great sensitivity, but it can be very time-consuming, typically using 60 min, or more, per sample analysis. We recently introduced the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation (~8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer for efficient analysis of peptide samples in proteomics research. The system performance of SPE-LC-MS/MS was evaluated in terms of sensitivity and efficiency for the analysis of tryptic peptide digests obtained from samples consisting of up to 12 standard proteins. The practical utility of the analytical setup was demonstrated by the analysis of <15 microg depleted human serum proteome by a combination of SDS-PAGE and SPE-LC-MS/MS. A total of 88 unique gene products spanning 3 orders of magnitude in serum protein concentration were identified using stringent database search criteria.  相似文献   

10.
Progress is reviewed towards the development of a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness and throughput of proteomic measurements based upon the use of high performance separations and mass spectrometry. The approach uses high accuracy mass measurements from Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate peptide 'accurate mass tags' (AMTs) produced by global protein enzymatic digestions for a specific organism, tissue or cell type from 'potential mass tags' tentatively identified using conventional tandem mass spectrometry (MS/MS). This provides the basis for subsequent measurements without the need for MS/ MS. High resolution capillary liquid chromatography separations combined with high sensitivity, and high resolution accurate FTICR measurements are shown to be capable of characterizing peptide mixtures of more than 10(5) components. The strategy has been initially demonstrated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, high sensitivity, and the capability for stableisotope labeling methods for precise relative protein abundance measurements.Abbreviations: LC, liquid chromatography; FTICR, Fourier transform ion cyclotron resonance; AMT, accurate mass tag; PMT, potential mass tag; MMA, mass measurement accuracy; MS, mass spectrometry; MS/MS, tandem mass spectrometry; ppm, parts per million.  相似文献   

11.
12.
A proteome of a model organism, Caenorhabditis elegans, was analyzed by an integrated liquid chromatography (LC)-based protein identification system, which was constructed by microscale two-dimensional liquid chromatography (2DLC) coupled with electrospray ionization (ESI) tandem mass spectrometry (MS/MS) on a high-resolution hybrid mass spectrometer with an automated data analysis system. Soluble and insoluble protein fractions were prepared from a mixed growth phase culture of the worm C. elegans, digested with trypsin, and fractionated separately on the 2DLC system. The separated peptides were directly analyzed by on-line ESI-MS/MS in a data-dependent mode, and the resultant spectral data were automatically processed to search a genome sequence database, wormpep 66, for protein identification. The total number of proteins of the composite proteome identified in this method was 1,616, including 110 secreted/targeted proteins and 242 transmembrane proteins. The codon adaptation indices of the identified proteins suggested that the system could identify proteins of relatively low abundance, which are difficult to identify by conventional 2D-gel electrophoresis (GE) followed by an offline mass spectrometric analysis such as peptide mass fingerprinting. Among the approximately 5,400 peptides assigned in this study, many peptides with post-translational modifications, such as N-terminal acetylation and phosphorylation, were detected. This expression profile of C. elegans, containing 571 hypothetical gene products, will serve as the basic data of a major proteome set expressed in the worm.  相似文献   

13.
A novel strategy for the quantitative profiling of serum proteome is described. It includes an ammonium sulfate depletion of the serum, an affordable stable isotope labeling chemistry for samples with a large amount of protein, separation of the unfolded proteins, and relative quantification by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS). Labeling of unfolded proteins was performed using normal (D0) acrylamide and deuterated (D3) acrylamide. The workflow for separating the unfolded proteins includes whole gel elution and ion exchange liquid chromatography, and it combines electrophoretic separation based on the protein molecular weight followed by chromatographic separation in the presence of 8 M urea based on protein charge. This was followed by trypsinolysis and MALDI MS analysis, leading to the quantification of a large number of serum proteins, including those with an abundance of 10-5 less than albumin. This robust and inexpensive workflow is suitable for the quantitative profiling of protein changes in serum associated with preanalytical variables.  相似文献   

14.
Serum potentially carries an archive of important histological information whose determination could serve to improve early disease detection. The analysis of serum, however, is analytically challenging due to the high dynamic concentration range of constituent protein/peptide species, necessitating extensive fractionation prior to mass spectrometric analyses. The low molecular weight (LMW) serum proteome is that protein/peptide fraction from which high molecular weight proteins, such as albumin, immunoglobulins, transferrin, and lipoproteins, have been removed. This LMW fraction is made up of several classes of physiologically important proteins such as cytokines, chemokines, peptide hormones, as well as proteolytic fragments of larger proteins. Centrifugal ultrafiltration of serum was used to remove the large constituent proteins resulting in the enrichment of the LMW proteins/peptides. Because albumin is known to bind and transport small molecules and peptides within the circulatory system, the centrifugal ultrafiltration was conducted under solvent conditions effecting the disruption of protein-protein interactions. The LMW serum proteome sample was digested with trypsin, fractionated by strong cation exchange chromatography, and analyzed by microcapillary reversed-phase liquid chromatography coupled on-line with electrospray ionization tandem mass spectrometry. Analysis of the tandem mass spectra resulted in the identification of over 340 human serum proteins; however, not a single peptide from serum albumin was observed. The large number of proteins identified demonstrates the efficacy of this method for the removal of large abundant proteins and the enrichment of the LMW serum proteome.  相似文献   

15.
Blood plasma is the most complex human-derived proteome, containing other tissue proteomes as subsets. This proteome has only been partially characterized due to the extremely wide dynamic range of the plasma proteins of more than ten orders of magnitude. Thus, the reduction in sample complexity prior to mass spectrometric analysis is particularly important and alternative separation methodologies are required to more effectively mine the lower abundant plasma proteins. Here, we demonstrated a novel separation approach using 2-D free-flow electrophoresis (FFE) separating proteins and peptides in solution according to their pI prior to LC-MS/MS. We used the combination of sequential protein and peptide separation by first separating the plasma proteins into specific FFE fractions. Tryptic digests of the separated proteins were generated and subsequently separated using FFE. The protein separation medium was optimized to segregate albumin into specific fractions containing only few other proteins. An optimization of throughput for the protein separation reduced the separation time of 1 mL of plasma to approximately 3 h providing sufficient material for digestion and the subsequent peptide separation. Our approach revealed low-abundant proteins (e.g., L-selectin at 17 ng/mL and vascular endothelial-cadherin precursor at 30 ng/mL) and several tissue leakage products, thus providing a powerful orthogonal separation step in the proteomics workflow.  相似文献   

16.
Human saliva contains a large number of proteins and peptides (salivary proteome) that help maintain homeostasis in the oral cavity. Global analysis of human salivary proteome is important for understanding oral health and disease pathogenesis. In this study, large-scale identification of salivary proteins was demonstrated by using shotgun proteomics and two-dimensinal gel electrophoresis-mass spectrometry (2-DE-MS). For the shotgun approach, whole saliva proteins were prefractionated according to molecular weight. The smallest fraction, presumably containing salivary peptides, was directly separated by capillary liquid chromatography (LC). However, the large protein fractions were digested into peptides for subsequent LC separation. Separated peptides were analyzed by on-line electrospray tandem mass spectrometry (MS/MS) using a quadrupole-time of flight mass spectrometer, and the obtained spectra were automatically processed to search human protein sequence database for protein identification. Additionally, 2-DE was used to map out the proteins in whole saliva. Protein spots 105 in number were excised and in-gel digested; and the resulting peptide fragments were measured by matrix-assisted laser desorption/ionization-mass spectrometry and sequenced by LC-MS/MS for protein identification. In total, we cataloged 309 proteins from human whole saliva by using these two proteomic approaches.  相似文献   

17.
We describe and review progress towards a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness, and throughput of proteomic measurements for microbial systems based upon the use of polypeptide accurate mass tags (AMTs) produced by global protein enzymatic digestions. The two-stage strategy exploits high accuracy mass measurements using Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate polypeptide AMTs for a specific organism, from potential mass tags tentatively identified using tandem mass spectrometry (MS/MS), providing the basis for subsequent measurements without the need for routine MS/MS. A high-resolution capillary liquid chromatography separation combined with high sensitivity, and high-resolution accurate FTICR measurements is shown to be capable of characterizing polypeptide mixtures of more than 10(5) components, sufficient for broad protein identification using AMTs. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, and the capability for stable-isotope labeling methods for precise relative protein abundance measurements. The strategy has been initially evaluated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Additional developments, including the use of multiplexed-MS/MS capabilities and methods for dynamic range expansion of proteome measurements that promise to further extend the quality of proteomics measurements, are also described.  相似文献   

18.
We investigated the combination of weak anion exchange (WAX) fractionation and on-line reversed-phase liquid chromatography (RPLC) separation using a 12 T FTICR mass spectrometer for the detection of intact proteins from a Shewanella oneidensis MR-1 cell lysate. This work aimed at optimizing intact protein detection for profiling proteins at a level that incorporates their modification state. A total of 715 intact proteins were detected, and the combined results from the WAX fractions and the unfractionated cell lysate were aligned using LC-MS features to facilitate protein abundance measurements. Protein identifications and post-translational modifications were assigned for approximately 10% of the detected proteins by comparing intact protein mass measurements to proteins identified in peptide MS/MS analysis of an aliquot of the same fraction. Intact proteins were also detected for S. oneidensis lysates obtained from cells grown on 13C-, 15N-depleted media under aerobic and sub-oxic conditions. The strategy can be readily applied for measuring differential protein abundances and provides a platform for high-throughput selection of biologically relevant targets for further characterization.  相似文献   

19.
Blood plasma is a valuable source of potential biomarkers. However, its complexity and the huge dynamic concentration range of its constituents complicate its analysis. To tackle this problem, an immunoprecipitation strategy was employed using antibodies directed against short terminal epitope tags (triple X proteomics antibodies), which allow the enrichment of groups of signature peptides derived from trypsin-digested plasma. Isolated signature peptides are subsequently detected using MALDI-TOF/TOF mass spectrometry. Sensitivity of the immunoaffinity approach was, however, compromised by the presence of contaminant peaks derived from the peptides of nontargeted high abundant proteins. A closer analysis of the enrichment strategy revealed nonspecific peptide binding to the solid phase affinity matrix as the major source of the contaminating peptides. We therefore implemented a sucrose density gradient ultracentrifugation separation step into the procedure. This yielded a 99% depletion of contaminating peptides from a sucrose fraction containing 70% of the peptide-antibody complexes and enabled the detection of the previously undetected low abundance protein filamin-A. Assessment of this novel approach using 15 different triple X proteomics antibodies demonstrated a more consistent detection of a greater number of targeted peptides and a significant reduction in the intensity of nonspecific peptides. Ultracentrifugation coupled with immunoaffinity MS approaches presents a powerful tool for multiplexed plasma protein analysis without the requirement for demanding liquid chromatography separation techniques.  相似文献   

20.
Proteomics is a commonly used approach that can provide insights into complex biological systems. The cochlear sensory epithelium contains receptors that transduce the mechanical energy of sound into an electro-chemical energy processed by the peripheral and central nervous systems. Several proteomic techniques have been developed to study the cochlear inner ear, such as two-dimensional difference gel electrophoresis (2D-DIGE), antibody microarray, and mass spectrometry (MS). MS is the most comprehensive and versatile tool in proteomics and in conjunction with separation methods can provide an in-depth proteome of biological samples. Separation methods combined with MS has the ability to enrich protein samples, detect low molecular weight and hydrophobic proteins, and identify low abundant proteins by reducing the proteome dynamic range. Different digestion strategies can be applied to whole lysate or to fractionated protein lysate to enhance peptide and protein sequence coverage. Utilization of different separation techniques, including strong cation exchange (SCX), reversed-phase (RP), and gel-eluted liquid fraction entrapment electrophoresis (GELFrEE) can be applied to reduce sample complexity prior to MS analysis for protein identification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号