The diagnostic programmes of modern pacemakers have increased our knowledge of atrial tachyarrhythmias (ATAs) in chronically paced patients. These programmes also support the evaluation of the effects of pharmacological treatment of ATAs. The success of interruption and/or prevention of ATAs with pacemakers depends strongly on the diagnostic accuracy and the properties of the pacing algorithms, their individual programming and the site and configuration of the pacing leads. Atrial septum pacing can be beneficial in patients with paroxysmal atrial fibrillation and prolonged P wave duration. Recent large-scale studies on preventive and interruptive atrial pacing of ATAs show modestly positive or no results. Therefore, atrial pacing therapy for ATAs should be considered cautiously, serving as an adjuvant to pharmacological treatment rather than as a primary intervention. This also applies for pacing interventions for ATAs in cardiac resynchronisation therapy. The pacemaker algorithms for the detection of ATAs and atrial lead configuration are crucial for the success of pacemaker-mediated prevention or interruption of ATAs. The success of these interventions is dependant on future improvements of pacemaker technology. (Neth Heart J 2008;16 (suppl 1): S20-S24.)  相似文献   

2.

Objectives

Left atrium (LA) plays an important role in left ventricular filling. It is well known that right ventricular apical pacing has unfavorable effects on ventricular systolic and diastolic performance. The aim of this study is to evaluate the LA mechanical functions with 2D echocardiography in patients with a permanent pacemaker after short time ventricular pacing.

Design

Echocardiographic examination was performed in 38 patients (mean age 63.0± 10.9, 18 female) with dual chamber pacemakers or defibrillators (< 20% ventricular pacing within previous 6 months, all of them on sinus rhythm) before and after 4 hours > 90% ventricular pacing at 70 beats per minute in DDD mode with an optimal AV interval. Left atrial volumes (LAV) including at the time of mitral valve opening (Vmax), at closure (Vmin), and at the onset of atrial systole (Volp) were measured. The passive emptying, conduit, active emptying and total emptying volume, stroke volumes were also calculated.

Results

No significant differences were noted at baseline and after pacing for absolute Vmax, Volp, passive emptying, conduit, active emptying, total emptying volumes as well as the volumes indexed to body surface area (p >0.05).

Conclusions

Short - time RV pacing seems to have no acute effects on left atrial mechanical functions.  相似文献   

3.

Purpose

To study the correlation between the sudden prolongations of the atrio-Hisian (AH) interval with ≥50 ms during burst and programmed atrial stimulation, and to define whether the AH jump during burst atrial pacing is a reliable diagnostic criterion for dual AV nodal physiology.

Methods

Retrospective data on 304 patients with preliminary ECG diagnosis of AV nodal reentrant tachycardia (AVNRT), confirmed during electrophysiological study, was analyzed for the presence of AH jump during burst and programmed atrial stimulation, and for correlation between the pacing modes for inducing the jump. Wilcoxon signed-ranks test and Spearman's bivariate correlation coefficient were applied, significant was P-value <0.05.

Results

The population was aged 48.5 ± 15.7 (12-85) years; males were 38.5%. AH jump occurred during burst atrial pacing in 81% of the patients, and during programmed stimulation – in 78%, P = 0.366. In 63.2% AH jump was induced by both pacing modes; in 17.8% – only by burst pacing; in 14.8% – only by programmed pacing; in 4.2% there was no inducible jump. There was negative correlation between both pacing modes, ρ = –0.204, Р<0.001.

Conclusion

Burst and programmed atrial stimulation separately prove the presence of dual AV nodal physiology in 81 and 78% of the patients with AVNRT, respectively. There is negative correlation between the two pacing modes, allowing the combination of the two methods to prove diagnostic in 95.8% of the patients.  相似文献   

4.
Pacing prevention algorithms have been introduced in order to maximize the benefits of atrial pacing in atrial fibrillation prevention. It has been demonstrated that algorithms actually keep overdrive atrial pacing, reduce atrial premature contractions, and prevent short-long atrial cycle phenomenon, with good patient tolerance. However, clinical studies showed inconsistent benefits on clinical endpoints such as atrial fibrillation burden. Factors which may be responsible for neutral results include an already high atrial pacing percentage in conventional DDDR, non-optimal atrial pacing site and deleterious effects of high percentages of apical ventricular pacing. Atrial antitachycardia pacing (ATP) therapies are effective in treating spontaneous atrial tachyarrhythmias, mainly when delivered early after arrhythmia onset and/or on slower tachycardias. Effective ATP therapies may reduce atrial fibrillation burden, but conflicting evidence does exist as regards this issue, probably because current clinical studies may be underpowered to detect such an efficacy. Wide application of atrial ATP may reduce the need for hospitalizations and electrical cardioversions and favorably impact on quality of life. Consistent monitoring of atrial and ventricular rhythm as well as that of ATP effectiveness may be extremely useful for optimizing device programming and pharmacological therapy.  相似文献   

5.
Macroreentrant atrial circuits are frequently associated with scarring. Previous reports have shown the possible development of scar tissue that is adjacent to pacemaker (PM) leads. However, reports of PM lead-related reentrant tachycardia are scarce. We report the case of a 63-year-old woman who presented with macroreentrant atrial tachycardia (MAT), related to the atrial trajectory of an old single-lead ventricular PM, that was successfully treated with radiofrequency ablation after a conventional electrophysiological study ruled out isthmus-dependent atrial flutter and provided sufficient data to confirm this diagnosis. This report presents a case of MAT originating around the trajectory of a PM lead, probably because of scar tissue that developed adjacent to the lead. Experimental studies have already shown that interstitial atrial fibrosis may develop adjacent to a ventricular single-lead. This finding suggests that MAT develops in patients with this specific condition. Recognizing this condition is important for managing these arrhythmias and performing safe ablation with the preservation of PM lead integrity.  相似文献   

6.
A 90-year-old woman received a dual chamber pacemaker (PM) for a sick sinus syndrome. The PM was programmed with SafeR AAI-DD pacing mode at 60 bpm. During a standard follow up, some memorized electrograms (EGMs) were found in SafeR diagnostics, with atrial pacing (Ap) not followed by any ventricular sensing/pacing event, due to simultaneous junctional activity falling into ventricular blanking period during Ap and, for this reason, unsensed by the PM. Blanking periods can affect PM functioning if not revealed and adjusted.  相似文献   

7.
Aim: To elucidate the protective effects of Matrine on atrial fibrillation (AF) induced by electric pacing in mice and underlying molecular and ion channel mechanisms.Methods: AF was introduced by electric pacing in mice and the incidence and duration of AF were evaluated. Functional expression of M3 receptor (M3-R) and Cav1.2 were explored by western and Real-time PCR, action potential (AP) and the density of (IKM3) L-type calcium channel (ICa-L) were both recorded using whole-cell patch in isolated atrial cardiomyocytes.Results: In control group, incidence and duration of AF induced by electric pacing were 50 ± 17% and 3.68 ± 1.84 s, respectively; after application of carbachol 50 µg/kg both incidence and duration of AF were significantly increased to 86 ± 24% and 65.2 ± 29.0 s. Compared with control group, pretreatment of Matrine for 15 days significantly reduced AF incidence and duration in dose-dependent manner. Atrial membrane-protein expression of M3-R was decreased and membrane Cav1.2 expression was up-regulated. In single Matrine-treated atrial cardiomyocyte the density of IKM3 was significantly decreased by 39% as well compared with control group, P < 0.05, whereas, ICa-L density of atrium was increased by 40%.Conclusion: These data demonstrated at the first time that the anti-AF effects of Matrine may due, at least in part, to down-regulation of IKM3 density and M3-R expression and up-regulation of ICa-L density and α1C/Cav1.2 expression.  相似文献   

8.

Background

A complete, bidirectional conduction block in the cavotricuspid isthmus (CTI) represents the end-point of the typical atrial flutter ablation. We investigated the correlation between two criteria for successful ablation, one based on the atrial bipolar electrogram morphology before and after complete CTI conduction block, compared to the standard criteria of differential pacing and reversal in the right atrial depolarization sequence during coronary sinus (CS) pacing.

Method

We conducted a retrospective study in 111 patients (81 males, average age 62±10 years) who underwent an atrial flutter ablation during September 2007 - July 2009 in the Cardiology - Rehabilitation Hospital, UMF Cluj-Napoca. We assessed the presence of a bidirectional block at the end of the procedure using the standard criteria. We then analyzed the morphology of the bipolar atrial electrograms adjacent to the ablation line, before and after CTI conduction block.

Results

A change from a qRs morphology to a rSr'' morphology when pacing from the coronary sinus and from a rsr'' morphology to a QRS morphology when pacing from the low-lateral right atrium was associated with a CTI conduction block. Sensitivity (Se), specificity(Sp), positive predictive value (PPV), negative predictive value (NPV) were 96%, 89%, 99% and 67% respectively.

Conclusion

Our study suggests that the analysis of the atrial bipolar electrogram next to the ablation line before and after CTI ablation may be used as a reliable criterion to validate CTI conduction block due to its high sensitivity, specificity and positive predictive value.  相似文献   

9.

Background

In patients undergoing coronary artery bypass surgery (CABGS), occurrence of atrial fibrillation (AF) is common in the postoperative period and is associated with increased morbidity with longer intensive unit care (ICU) and hospital stay. Prevention with antiarrhythmic drugs is of limited success and associated with significant side effects. Therefore alternative approaches, such as Bachmann Bundle pacing, are required.

Methods and Results

154 consecutive patients, mean age 58±8.8 years, including 134 males and 20 females, were randomized to three groups; Group I : No pacing n= 54, Group II : RA pacing n= 52, Group III : Bachmann Bundle pacing n= 48. All the groups were well matched with regard to age, left atrial size, ejection fraction and use of beta blockers. Patients in Groups II and III were continually paced at a rate of 100 beats per minute (bpm) or at 10 bpm more than patients'' intrinsic heart rate. All the patients were monitored for 72 hours by telemetry and occurrence of AF was noted. Incidence of AF was 0% (none of 48 patients) in Group III as compared to 16.6% in Group I (9 of 54 patients) (p 0.003) and 12.5% in Group II (5 of 52 patients) (p 0.03). There was a trend towards shorter ICU stay in Group III (3.9 days) as compared to Group II (4.5 days) and Group I (4.1 days). Among the three groups, the reduction in mean P wave duration also was greater in Bachmann bundle paced group.

Conclusion

In patients undergoing CABGS, Bachmann bundle pacing is superior to right atrial / no pacing in the post operative period for preventing occurrence of AF and reducing ICU stay, commensurate with a reduction in mean P wave duration on surface ECG.  相似文献   

10.
Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF.

Methods and results

Seventeen patients (16 males, mean age 73?±?6 years, mean EF 25?±?5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103?±?22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up.

Conclusion

Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population.  相似文献   

11.

Introduction

We examined the acute effects of neutral endopeptidase inhibitor on the hemodynamics and electrical properties of dogs subjected to rapid atrial pacing.

Methods

Ten beagle dogs were used and divided into two groups with and without candoxatril, a neutral endopeptidase inhibitor preadministration. Before and after the 6 hours rapid atrial pacing from the right atrial appendage, the hemodynamics, atrial effective refractory period, and monophasic action potential duration of the right atrial appendage were measured and blood samples were collected. Atrial tissue was also excised after the experiment.

Results

Candoxatril significantly increased plasma ANP levels (Control: 88.4 ± 50.25 vs. Candoxatril: 197.1 ± 32.09 pg/ml, p = 0.004) and prevented reductions in atrial effective refractory period and monophasic action potential duration. We further demonstrated that the treated animals exhibited significantly higher levels of atrial tissue cyclic GMP (Control: 28.1 ± 1.60 fmol/mg vs. Candoxatril: 44.5 ± 12.28 fmol/mg, p = 0.034) as well as that of plasma cyclic GMP (Control: 32 ± 5.5 vs. Candoxatril: 42 ± 7.1 pg/ml, p = 0.028).

Conclusion

Candoxatril suppressed the shortening of atrial effective refractory period and monophasic action potential duration in the rapid atrial pacing model. As plasma ANP and the atrial tissue levels of cyclic GMP were higher in the Candoxatril group than the control, this effect was considered to appear through the reduction of calcium overload caused by ANP and cyclic GMP.  相似文献   

12.
This study aims to observe the effects of ibutilide on canine cardiac pacing threshold and on induction rates of atrial fibrillation. Eighteen mongrel dogs were anesthetized and administrated with ibutilide. The pacing thresholds and induction rates of atrial fibrillation were measured with and without ibutilide (10-min infusion dose was 0.10?mg?kg?1, followed by a maintaining dose of 0.01?mg?min?1 30?min later). This study found that ibutilide increases pacing thresholds in dogs. Moreover, there were significant differences between pacing thresholds with and without ibutilide (P?<?0.05). Further, ibutilide significantly reduces the induction rates of atrial fibrillation (P?<?0.05). Our findings indicate that pacing voltage changes should be closely monitored in patients taking anti-arrhythmic drugs, who are treated with cardiac stimulation or have undergone pacemaker implantation. We also found that ibutilide is an effective drug in preventing or controlling atrial fibrillation.  相似文献   

13.
Parahisian pacing (PHP) is a useful maneuver during electrophysiology study of supraventricular tachycardia (SVT) especially when the tachycardia is non-sustained. Various responses during PHP can differentiate between the routes of VA conduction (VAC). In a case of WPW syndrome with orthodromic re-entrant tachycardia, we encountered various responses which one must be cognizant about to avoid erroneous conclusions. Along with para-hisian capture and only ventricular capture, simultaneous atrial capture (SAC) and pure His capture were also noted. Moreover, during pure-His capture underlying distal antegrade right bundle branch block (RBBB) was encountered making it an intriguing case.  相似文献   

14.
15.

Background

Although the number of newly detected leprosy cases has decreased globally, a quarter of a million new cases are detected annually and eradication remains far away. Current options for leprosy prevention are contact tracing and BCG vaccination of infants. Future options may include chemoprophylaxis and early diagnosis of subclinical infections. This study compared the predicted trends in leprosy case detection of future intervention strategies.

Methods

Seven leprosy intervention scenarios were investigated with a microsimulation model (SIMCOLEP) to predict future leprosy trends. The baseline scenario consisted of passive case detection, multidrug therapy, contact tracing, and BCG vaccination of infants. The other six scenarios were modifications of the baseline, as follows: no contact tracing; with chemoprophylaxis; with early diagnosis of subclinical infections; replacement of the BCG vaccine with a new tuberculosis vaccine ineffective against Mycobacterium leprae (“no BCG”); no BCG with chemoprophylaxis; and no BCG with early diagnosis.

Findings

Without contact tracing, the model predicted an initial drop in the new case detection rate due to a delay in detecting clinical cases among contacts. Eventually, this scenario would lead to new case detection rates higher than the baseline program. Both chemoprophylaxis and early diagnosis would prevent new cases due to a reduction of the infectious period of subclinical cases by detection and cure of these cases. Also, replacing BCG would increase the new case detection rate of leprosy, but this effect could be offset with either chemoprophylaxis or early diagnosis.

Conclusions

This study showed that the leprosy incidence would be reduced substantially by good BCG vaccine coverage and the combined strategies of contact tracing, early diagnosis, and treatment of infection and/or chemoprophylaxis among household contacts. To effectively interrupt the transmission of M. leprae, it is crucial to continue developing immuno- and chemoprophylaxis strategies and an effective test for diagnosing subclinical infections.  相似文献   

16.

Background

Implantable cardioverter defibrillators (ICDs) are designed to deliver shocks or antitachycardia pacing (ATP) in the event of ventricular arrhythmias. During follow-up, some ICD recipients experience the sensation of ICD discharge in the absence of an actual discharge (phantom shock). The aim of this study was to evaluate the incidence and predictors of phantom shocks in ICD recipients.

Methods

Medical records of 629 consecutive patients with ischaemic or dilated cardiomyopathy and prior ICD implantation were studied.

Results

With a median follow-up of 35 months, phantom shocks were reported by 5.1 % of ICD recipients (5.7 % in the primary prevention group and 3.7 % for the secondary prevention group; p=NS). In the combined group of primary and secondary prevention, there were no significant predictors of the occurrence of phantom shocks. However, in the primary prevention group, phantom shocks were related to a history of atrial fibrillation (p=0.03) and NYHA class <III (p=0.05). In the secondary prevention group, there were no significant predictors for phantom shocks.

Conclusion

Phantom shocks occur in approximately 5 % of all ICD recipients. In primary prevention patients, a relation with a history of atrial fibrillation and NYHA class <III were significant predictors for the occurrence of phantom shocks. In the secondary prevention patients, no significant predictors were found.  相似文献   

17.
Atrial fibrosis is an important factor in the initiation and maintenance of atrial fibrillation (AF); therefore, understanding the pathogenesis of atrial fibrosis may reveal promising therapeutic targets for AF. In this study, we successfully established a rapid atrial pacing canine model and found that the inducibility and duration of AF were significantly reduced by the overexpression of c‐Ski, suggesting that this approach may have therapeutic effects. c‐Ski was found to be down‐regulated in the atrial tissues of the rapid atrial pacing canine model. We artificially up‐regulated c‐Ski expression with a c‐Ski–overexpressing adenovirus. Haematoxylin and eosin, Masson's trichrome and picrosirius red staining showed that c‐Ski overexpression alleviated atrial fibrosis. Furthermore, we found that the expression levels of collagen III and α‐SMA were higher in the groups of dogs subjected to right‐atrial pacing, and this increase was attenuated by c‐Ski overexpression. In addition, c‐Ski overexpression decreased the phosphorylation of smad2, smad3 and p38 MAPK (p38α and p38β) as well as the expression of TGF‐β1 in atrial tissues, as shown by a comparison of the right‐atrial pacing + c‐Ski‐overexpression group to the control group with right‐atrial pacing only. These results suggest that c‐Ski overexpression improves atrial remodelling in a rapid atrial pacing canine model by suppressing TGF‐β1–Smad signalling and p38 MAPK activation.  相似文献   

18.
Sudden cardiac death (SCD) is one of the leading causes of mortality in industrialized countries. Thus, identifying patients at high risk of SCD is an important goal. T wave alternans (TWA) is a new method for identifying patients with lethal ventricular tachyarrhythmias, and is dependent on heart rate. The maximal predictive accuracy is achieved at heart rates between 100 and 120 bpm, so that TWA is usually measured during exercise, pharmacological stress, or atrial pacing. It has been shown that TWA has high sensitivity and negative predictive value for predicting SCD after myocardial infarction and is also useful for predicting SCD in patients with nonischemic cardiomyopathy. Although the implantable cardioverter defibrillator (ICD) is now the primary therapy for preventing SCD, it is difficult to identify those patients who are susceptible to lethal ventricular tachyarrhythmias for primary prevention. In the prediction of SCD, TWA can be used as a screening test of appropriate patients for further electrophysiological examination and therapy.  相似文献   

19.
Remodeling of the left atrium in pacing-induced atrial cardiomyopathy   总被引:13,自引:0,他引:13  
Rapid atrial pacing produces atrial systolic and diastolic failure characterized by absent atrial booster pump function, increased atrial chamber stiffness, enhanced atrial conduit function, and atrial enlargement. However, the processes underlying these abnormalities are poorly understood. Therefore, we examined left atrial myocardium from dogs with rapid pacing-induced atrial failure (400 bpm for 6 weeks) and from control dogs. Western blotting was used to determine the levels of proteins involved in calcium homeostasis (SERCA 2A, phospholamban, Na+-Ca2+ exchanger). Matrix metalloproteinase (MMP) activity was measured using gelatin and casein zymography, and levels of tissue inhibitor of metalloproteinase-4 (TIMP-4) and the TIMP-4 complexed with MMPs were measured with Western blot analysis. There were no differences in SERCA 2A or Na+-Ca2+ exchanger protein levels, but phospholamban level was significantly decreased in atrial samples from rapidly paced dogs (51.2 ± 7.8 vs. 77.0 ± 10.0, p < 0.01). The activity of MMP-9 was selectively and significantly increased by 50%, and the level of complexed TIMP-4 protein was significantly decreased by 50% in samples from dogs with atrial failure. Thus, rapid pacing-induced atrial failure is associated with differential changes in MMP activity, an unchanged number of calcium pumps, and compensatory changes in the level of phospholamban.  相似文献   

20.
目的:探讨起搏器术后新发房性心律失常的发生情况及其相关影响因素。方法:选择2006年1月至2007年12月于沈阳军区总医院首次植入永久起搏器的107例患者,男性50例,平均年龄65.0±11.9岁,术前通过追问病史及相关检查均排除房性心律失常(房颤、房扑、房速),术后平均随访3.9年,观察新发房性心律失常情况。按术后是否出现房性心律失常,将患者分为新发房性心律失常组和无房性心律失常组,比较两组患者术前和术后心脏超声结果的变化、心室起搏比例、起搏部位及起搏模式,并通过logistic回归分析起搏器术后发生房性心律失常的影响因素。结果:新发房性心律失常组26例(24.3%),其中房颤17例(15.9%),房扑2例(1.9%),房速7例(6.5%);无房性心律失常组81例。与无房性心律失常组比较,新发房性心律失常组左房内径明显增加(P=0.040)、二尖瓣返流程度较重(P=0.032)及左室射血分数明显下降(P=0.001),心室起搏百分比(VP%)显著升高(P=0.017)。心尖部起搏患者房性心律失常的发生率明显高于间隔部起搏(33.3%vs 16.9%,P<0.05),双腔起搏组患者房性心律失常发生率明显低于单腔起搏器组(18.7%vs 37.5%,P<0.05)。Logistic回归分析显示术后新发房性心律失常的发生与高比例的心室起搏(P=0.006)、VVI(R)起搏模式(P=0.014)及右心室起搏电极导线植于心尖部(P=0.024)显著相关。结论:起搏模式、心室起搏百分比、起搏部位是起搏器术后发生房性心律失常的影响因素。  相似文献   