1.
In selected patients with atrial fibrillation and severe symptoms, non-pharmacological treatment may be an alternative or supplement to drug therapy. Atrioventricular nodal radiofrequency ablation (requires pacemaker implantation), or atrial pacing for sick sinus syndrome, are established treatment modalities. All other non-pharmacological therapies for atrial fibrillation are still experimental. After the Maze operation, atrial depolarization has to follow one specific path determined by surgical scars in the myocardium. This prevents new episodes of atrial fibrillation, but at a cost of perioperative morbidity and mortality. Catheter-based "Maze-like" radiofrequency ablation is technically difficult, and thrombo-embolic complications may occur. Paroxysmal atrial fibrillation sometimes is initiated by spontaneous depolarizations in a pulmonary vein inlet. Radio frequency ablation against such focal activity has been reported with high therapeutic success, but the results await confirmation from several centres. For ventricular rate control, most electrophysiologists presently prefer ablation to induce a complete atrioventricular conduction block (with pacemaker) rather than trying to modify conduction by incomplete block. Atrial or dual chamber pacing may prevent atrial fibrillation induced by bradycardia. It remains to confirm that biatrial or multisite right atrial pacing prevents atrial fibrillation more efficiently than ordinary right atrial pacing. An atrial defibrillator is able to diagnose and convert atrial fibrillation. The equipment is expensive, and therapy without sedation may be unpleasant beyond tolerability.  相似文献   

2.
Nonvalvular atrial fibrillation is an increasingly common condition. It may cause disabling symptoms and is an important risk factor for stroke. The goals of treatment include the relief and prevention of rate- and rhythm-related symptoms and the prevention of stroke and systemic emboli. Three principal treatments should be considered: pharmacologic rate control, cardioversion and antiarrhythmic therapy to restore and maintain sinus rhythm, and prophylactic anticoagulation or antiplatelet therapy to reduce the risk of stroke. The risks and benefits of each of these therapies have been reviewed. Symptoms, if present, can often be managed safely with rate-directed therapy alone. Until issues regarding safety and long-term efficacy are resolved, cardioversion and antiarrhythmic therapy should be limited to those patients whose symptoms cannot otherwise be controlled. The benefits of warfarin anticoagulation for the primary and secondary prevention of stroke in nonvalvular atrial fibrillation have been demonstrated convincingly by several randomized clinical trials. These benefits must be weighed against the real risk of major hemorrhage. For patients at low risk of stroke, the use of aspirin may be an acceptable alternative to warfarin sodium therapy.  相似文献   

3.
Recent studies have demonstrated that fibrillatory rhythms are not random phenomena but have definable patterns. However, standard mapping techniques may have limitations in their ability to identify the organization of fibrillation. The purpose of this study was to develop and apply a method, "ensemble vector mapping," for characterizing the spatiotemporal organization of fibrillation. Ventricular fibrillation was induced by burst pacing in normal mongrel dogs. In a separate protocol, atrial fibrillation was induced by epicardial aconitine application. Epicardial electrograms were recorded from a 112-electrode plaque array using a computerized mapping system. Vectors were created by summing orthogonal bipolar electrograms. The magnitude of the vectors was transformed using a logarithmic function, integrated over time, and normalized for local electrogram amplitude to produce an "ensemble vector" index whose magnitude is high when beat-to-beat activation direction is consistent and low when activation direction is variable. The mean index was 137 +/- 36 mV/s during ventricular pacing at a cycle length of 300 ms but only 39 +/- 23 mV/s during ventricular fibrillation (P < 0.001). The ensemble vector index was also lower during atrial fibrillation (60 +/- 54 mV/s) than during atrial pacing (115 +/- 27 mV/s, P < 0.01 vs. atrial fibrillation) but not as low as during ventricular fibrillation (P < 0.05, atrial vs. ventricular fibrillation). The index was also capable of distinguishing atrial tachycardia from atrial fibrillation. Ensemble vector mapping produces an objective assessment of the consistency of myocardial activation during fibrillation. The consistency of activation direction differs in different models of fibrillation and is higher during atrial than ventricular fibrillation. This technique has the potential to rapidly characterize repetitive activation patterns in fibrillatory rhythms and may help distinguish among different characteristics of fibrillatory rhythms.  相似文献   

4.
The diagnostic programmes of modern pacemakers have increased our knowledge of atrial tachyarrhythmias (ATAs) in chronically paced patients. These programmes also support the evaluation of the effects of pharmacological treatment of ATAs. The success of interruption and/or prevention of ATAs with pacemakers depends strongly on the diagnostic accuracy and the properties of the pacing algorithms, their individual programming and the site and configuration of the pacing leads. Atrial septum pacing can be beneficial in patients with paroxysmal atrial fibrillation and prolonged P wave duration. Recent large-scale studies on preventive and interruptive atrial pacing of ATAs show modestly positive or no results. Therefore, atrial pacing therapy for ATAs should be considered cautiously, serving as an adjuvant to pharmacological treatment rather than as a primary intervention. This also applies for pacing interventions for ATAs in cardiac resynchronisation therapy. The pacemaker algorithms for the detection of ATAs and atrial lead configuration are crucial for the success of pacemaker-mediated prevention or interruption of ATAs. The success of these interventions is dependant on future improvements of pacemaker technology. (Neth Heart J 2008;16 (suppl 1): S20-S24.)  相似文献   

5.
Background. Correct pacemaker (PM) diagnosis of paroxysmal atrial tachyarrhythmias is crucial for their prevention and intervention with specific atrial pacing programmes. The PM mode switch to only ventricular pacing after detection of atrial tachyarrhythmias is often used as the parameter to quantify the ‘burden’ of atrial tachyarrhythmias. Objectives. This review addresses potential errors in the detection and diagnosis of atrial tachyarrhythmias, sometimes resulting in incorrect mode switches. The interpretation of PM-stored data of patients with atrial tachyarrhythmias and the results of trials of pace prevention and intervention can be better appreciated with more insight into the technical options and pitfalls. Results. Literature and clinical experience demonstrate that the correctness of PM-derived diagnosis of atrial tachyarrhythmias depends on 1) the sensitivity setting to detect the onset and perpetuation of atrial tachyarrhythmias frequently characterised by variable and low-voltage signals, 2) the rejection of far-field R wave sensing by the atrial sense amplifier, 3) the facility for verification of mode switches by a high-quality intracardiac registration of the nonmodified atrial electrogram. The configuration of the atrial lead also contributes to the diagnostic performance of the PM. Conclusion. Not only pacing algorithms and diverse technical PM features but also the atrial lead configuration are currently the limiting factors to the fully reliable, automated detection and diagnosis of atrial tachyarrhythmias. If these technical shortcomings can be improved, better signal processing will result. Then atrial pacing to prevent or suppress atrial tachyarrhythmias will be more justified. (Neth Heart J 2008;16:201-10.)  相似文献   

6.
Atrial fibrillation is the most common cardiac arrhythmia, affecting more than two million people in the US. Several therapies for patients with atrial fibrillation are available, but methods to help physicians select the optimal therapy for an individual patient are still required. Knowledge of whether a patient with a normal ECG will exhibit atrial fibrillation in the future, as well as whether atrial fibrillation will terminate spontaneously, would be very useful in clinical routine. The paper presents a software system for predicting the initiation and termination of atrial fibrillation from the ECG. The algorithms have been validated on ECGs from several signal databases. Prediction of the initiation of atrial fibrillation was achieved by detecting premature heart beats and analyzing the morphology of their P waves. Prediction of the termination of atrial fibrillation was based on calculation of the major atrial frequency. This frequency has been shown to decrease significantly prior to the termination of atrial fibrillation. Nevertheless, the effect is much less distinct in the large data set used for this study compared to previous studies. The initiation of atrial fibrillation, however, could be correctly predicted in approximately 75% of the data analyzed.  相似文献   

7.

Background

Current algorithms and device morphology templates have been proposed in current Implantable Cardioverter-Defibrillators (ICDs) to minimize inappropriate therapies (ITS), but this has not been completely successful.

Aim

Assess the impact of a deliberate strategy of using an atrial lead implant with standardized parameters; based on all current ICD discriminators and technologies, on the burden of ITS.

Method

A retrospective single-centre analysis of 250 patients with either dual chamber (DR) ICDs or biventricular ICDs (CRTDs) over a (41.9 ± 27.3) month period was performed. The incidence of ITS on all ICD and CRTD patients was chronicled after the implementation of standardized programming.

Results

39 events of anti-tachycardial pacing (ATP) and/or shocks were identified in 20 patients (8% incidence rate among patients). The total number of individual therapies was 120, of which 34% were inappropriate ATP, and 36% were inappropriate shocks. 11 patients of the 250 patients received ITS (4.4%). Of the 20 patients, four had ICDs for primary prevention and 16 for a secondary prevention. All the episodes in the primary indication group were inappropriate, while seven patients (43%) of the secondary indication group experienced inappropriate therapies.

Conclusions

The burden of ITS in the population of patients receiving ICDs was 4.4% in the presence of atrial leads. The proposed rationalized programming criteria seems an effective strategy to minimize the burden of inappropriate therapies and will require further validation.  相似文献   

8.
Excessive right ventricular apex pacing has significant adverse effects on the cardiac function and hence, it is necessary to clinically optimize pacing parameters and advocate suitable physiological pacing to safeguard the cardiac function after pacemaker implant. Minimizing ventricular pacing is an atrioventricular node priority function, to encourage ventricular self conduction and to reduce unnecessary right ventricular pacing. Minimized ventricular pacing reduces ventricular pacing by encouraging self atrioventricular conduction function and extending the AV interval. This study is a prospective cohort study to evaluate the changes of cardiac function in patients and serum amino-terminal natriuretic peptide (NT-proBNP) before and after pacing, and the risk of atrial fibrillation with different CUM% VP. The study has shown that the cardiac function will deteriorate with an increase in pacing rate.  相似文献   

9.
In patients with sick sinus syndrome and normal atrioventricular conduction, physiological pacing can be accomplished with either a single chamber atrial pacemaker AAI/R or a dual chamber pacemaker DDD/R. The single chamber device has the advantages of simpler implantation and lower initial costs, while the dual chamber device offers protection in case atrioventricular conduction disturbances develop in the future. When rigorous attention is paid to the pre-implantation selection criteria, the incidence of reported second- or third-degree atrioventricular block varied between 0.4 and 1.8% per annum. Medical practice, however, has shifted to predominant implantation of DDD/R pacemakers in more than 95% of patients with sick sinus syndrome. Recent publications have reported an increase in left atrial diameter, decrease in left ventricular fractional shortening and increased incidence of atrial fibrillation in patients with DDD/R pacing as compared with patients with single chamber atrial devices. These changes were proportional to the percentage of ventricular paced beats. New algorithms in dual chamber devices have been developed in order to minimise ventricular stimulation. These are being evaluated at present. In my opinion there is still a place for atrial pacing in selected patients with sick sinus syndrome with a minimum risk of developing complete atrioventricular block. (Neth Heart J 2008;16(suppl 1): S25-S27.)  相似文献   

10.
目的:探讨起搏器术后新发房性心律失常的发生情况及其相关影响因素。方法:选择2006年1月至2007年12月于沈阳军区总医院首次植入永久起搏器的107例患者,男性50例,平均年龄65.0±11.9岁,术前通过追问病史及相关检查均排除房性心律失常(房颤、房扑、房速),术后平均随访3.9年,观察新发房性心律失常情况。按术后是否出现房性心律失常,将患者分为新发房性心律失常组和无房性心律失常组,比较两组患者术前和术后心脏超声结果的变化、心室起搏比例、起搏部位及起搏模式,并通过logistic回归分析起搏器术后发生房性心律失常的影响因素。结果:新发房性心律失常组26例(24.3%),其中房颤17例(15.9%),房扑2例(1.9%),房速7例(6.5%);无房性心律失常组81例。与无房性心律失常组比较,新发房性心律失常组左房内径明显增加(P=0.040)、二尖瓣返流程度较重(P=0.032)及左室射血分数明显下降(P=0.001),心室起搏百分比(VP%)显著升高(P=0.017)。心尖部起搏患者房性心律失常的发生率明显高于间隔部起搏(33.3%vs 16.9%,P<0.05),双腔起搏组患者房性心律失常发生率明显低于单腔起搏器组(18.7%vs 37.5%,P<0.05)。Logistic回归分析显示术后新发房性心律失常的发生与高比例的心室起搏(P=0.006)、VVI(R)起搏模式(P=0.014)及右心室起搏电极导线植于心尖部(P=0.024)显著相关。结论:起搏模式、心室起搏百分比、起搏部位是起搏器术后发生房性心律失常的影响因素。  相似文献   

11.
Endomyocardial fibrosis (EMF) is characterized by fibrous tissue deposition on the endocardial surface leading to impaired filling of one or both ventricles, resulting in either right or left heart failure or both. Although Sinus node dysfunction and tachyarrhythmia - atrial fibrillation, ventricular tachycardia, have been commonly reported, complete heart block (CHB) necessitating a pacemaker is rare in EMF. Transvenous pacing is technically limited by fibrotic obliteration of the affected ventricle that results in poor lead parameters, and alternative pacing strategy like epicardial pacing may be required in many. We report three cases of EMF, who were treated with an alternative pacing strategy.  相似文献   

12.
Atrial fibrillation (AF) is associated with morbidity and mortality of heart failure. Eicosapentaenoic acid (EPA), which is contained in fish oil, was shown to reduce the risk of cardiovascular diseases. We investigated the effects of EPA on AF associated with heart failure in a rabbit model. Rabbits were subjected to ventricular tachypacing (VTP) for 4 wk with or without EPA treatment. Continuous VTP induced heart failure status in these rabbits. The duration of AF (DAF) induced by burst pacing was analyzed by electrophysiological studies. VTP resulted in increased DAF following burst pacing. EPA treatment attenuated increased DAF. Atrial fibrosis increased in response to VTP, accompanied by extracellular signal-regulated kinase (ERK) phosphorylation and transforming growth factor-β1 (TGF-β1) expression in the atrium. Treatment with EPA attenuated atrial fibrosis, ERK phosphorylation, and TGF-β1 expression in response to VTP. EPA treatment increased adiponectin as an anti-inflammatory adipokine and decreased tumor necrosis factor-α as a proinflammatory adipokine in the atrium and epicardial adipose tissues. EPA attenuated VTP-induced AF promotion and atrial remodeling, which was accompanied by modulating the profiles of adipokine production from epicardial adipose tissue. EPA may be useful for prevention and treatment of AF associated with heart failure.  相似文献   

13.
Implantable defibrillators are lifesavers and have improved mortality rates in patients at risk of sudden death, both in primary and secondary prevention. However, they are unable to modify the myocardial substrate, which remains susceptible to life-threatening ventricular arrhythmias. Electrical storm is a clinical entity characterized the recurrence of hemodynamically unstable ventricular tachycardia and/or ventricular fibrillation, twice or more in 24 hours, requiring electrical cardioversion or defibrillation. With the arrival of the implantable cardioverter-defibrillator, this definition was broadened, and electrical storm is now defined as the occurrence of three or more distinct episodes of ventricular tachycardia or ventricular fibrillation in 24 hours, requiring the intervention of the defibrillator (anti-tachycardia pacing or shock). Clinical presentation can be very dramatic, with multiple defibrillator shocks and hemodynamic instability. Managing its acute presentation is a challenge, and mortality is high both in the acute phase and in the long term. In large clinical trials involving patients implanted with a defibrillator both for primary and secondary prevention, electrical storm appears to be a harbinger of cardiac death, with notably high mortality soon after the event. In most cases, the storm can be interrupted by medical therapy, though transcatheter radiofrequency ablation of ventricular arrhythmias may be an effective treatment for refractory cases.This narrative literature review outlines the main clinical characteristics of electrical storm and emphasises critical points in approaching and managing this peculiar clinical entity. Finally focus is given to studies that consider transcatheter ablation therapy in cases refractory to medical treatment.  相似文献   

14.
A 62-year-old patient presented with dizzy spells after her dual chamber pacemaker (Medtronic Enrhythm P1501DR), implanted for complete AV block, had been reprogrammed to deliver antitachycardia therapy (ATP) for paroxysmal atrial tachycardia. Her symptoms were caused by inhibition of ventricular backup pacing during ATP, leading to ventricular asystoles. Inhibition was the result of premature ventricular beats occurring prior to ATP: when ventricular backup pacing is left in the default setting, this pacemaker withholds backup pacing if any of the four preceding events is a sensed event. This case illustrates the possibly hazardous effects of default pacemaker settings, especially in pacemaker-dependent patients. (Neth Heart J 2010;18:323-6.)  相似文献   

15.
Automatic mode switching (AMS) algorithms were designed to prevent tracking of atrial tachyarrhythmias (ATA) or other rapidly occurring signals sensed by atrial channels, thereby reducing the adverse hemodynamic and symptomatic consequences of a rapid ventricular response. The inclusion of an AMS function in most dual chamber pacemaker now provides optimal management of atrial arrhythmias and allows the benefit of atrioventricular synchrony to be extended to a population with existing atrial fibrillation. Appropriate AMS depends on several parameters: a) the programmed parameters; b) the characteristics of the arrhythmia; c) the characteristics of the AMS algorithm. Three qualifying aspects constitute an AMS algorithm: onset, AMS response, and resynchronization. Since AMS programs also provide data on the time of onset and duration of AMS episodes, AMS data may be interpreted as a surrogate marker of ATAs recurrence. Recently, stored electrograms corresponding to episodes of ATAs have been introduced, thus clarifying the accuracy of AMS in detecting ATAs Clinically this information may be used to assess the efficacy of an antiarrhythmic intervention or the risk of thromboembolic events, and it may serve as a valuable research tool for evaluating the natural history and burden of ATAs.  相似文献   

16.
Current pacing practice is undergoing continuous and substantial changes. Initially pacing had an exclusively palliative role, since it was reserved for patients developing complete heart block or severe symptomatic bradycardia. With the appearance of novel pacing indications such as pacing for heart failure and atrial fibrillation, the effect of pacing site on cardiac function has become a critically important issue and a subject for consideration. It seems that the classical pacing site in the right ventricular apex is no longer the gold standard because of possible disadvantageous effects on cardiac function. The aim of this review article is to discuss the effect of right ventricular apical pacing on cardiac function including cellular and hemodynamic changes. We also aim to discuss the role of alternative pacing sites in the light of cardiac function.  相似文献   

17.
Coupled pacing (CP), a method for controlling ventricular rate during atrial fibrillation (AF), consists of a single electrical stimulation applied to the ventricles after each spontaneous activation. CP results in a mechanical contraction rate approximately one-half the rate during AF. Paired stimulation in which two electrical stimuli are delivered to the ventricles has also been proposed as a therapy for heart failure. Although paired stimulation enhances contractility, it greatly increases energy consumption. The primary hypothesis of the present study is that CP improves cardiac function during acute AF without a similar increase in energy consumption because of the reduced rate of ventricular contractions. In a canine model, CP was applied during four stages: sinus rhythm (SR), acute AF, cardiac dysfunction (CD), and AF in the presence of cardiac dysfunction. The rate of ventricular contraction decreased in all four stages as the result of CP. In addition, we determined the changes in external cardiac work, myocardial oxygen consumption, and myocardial efficiency in the each of four stages. CP partially reversed the effects of AF and CD on external cardiac work, whereas myocardial oxygen consumption increased only moderately. In all stages but SR, CP increased myocardial efficiency because of the marked increases in cardiac work compared with the moderate increases in total energy consumed. Thus this pacing therapy may be a viable therapy for patients with concurrent atrial fibrillation and heart failure.  相似文献   

18.
After implantation of a permanent pacemaker, patients may experience severe symptoms of dyspnea, palpitations, malaise, and syncope resulting from pacemaker syndrome. Although pacemaker syndrome is most often ascribed to the loss of atrioventricular (A-V) synchrony, more recent data may also implicate left ventricular dysynchrony caused by right ventricular pacing. Previous studies have not shown reductions in mortality or stroke with rate-modulated dual-chamber (DDDR) pacing as compared to ventricular-based (VVI) pacing. The benefits in A-V sequential pacing with the DDDR mode are likely mitigated by the interventricular (V-V) dysynchrony imposed by the high percentage of ventricular pacing commonly seen in the DDDR mode. Programming DDDR pacemakers to encourage intrinsic A-V conduction and reduce right ventricular pacing will likely decrease heart failure and pacemaker syndrome. Studies are currently ongoing to address these questions.  相似文献   

19.
目的:探讨植入心脏起搏器的老年阵发性房颤患者再发房颤(包括无症状性房颤)发生率及左房容积指数对再发房颤的影响。方法:收集2012年1月-2013年12月在我院起搏器门诊长期随访且未服用抗心律失常药物的起搏器术后老年阵发性房颤患者148例,记录基线特征、超声心动图参数及随访期间内房颤发生情况。分别根据左房容积指数及房颤负荷进行分组,应用Cox回归分析探讨起搏器检测的再发房颤及房颤高负荷的危险因素。结果:患者平均随访时间为22.79个月,期间57.43%的患者再发房颤,22.97%的患者为房颤高负荷,15.54%的患者为无症状房颤。多因素Cox回归分析发现左房增大分别是再发房颤及房颤高负荷的独立危险因素。结论:左房容积指数是预测起搏器术后老年阵发性房颤患者房颤复发及房颤高负荷的独立危险因素。  相似文献   

20.
摘要 目的:探究永久起搏器程控在心房颤动诊断中的临床应用及意义。方法:选择78例我院收治的心房颤动患者随机分为程控组和非程控组2组,其中观察组患者给与永久起搏器程控诊断,非程控组则仅给植入永久起搏器,但非程控。对比分析两组患者基本资料、房颤负荷、心房与心室起搏比、心房结构重构及左心功能、P波结果;比较永久起搏器程控诊断与临床诊断结果的差异,分析永久起搏器程控在心房颤动诊断敏感度。结果:程控组和非程控组患者的男女比例、年龄、心率失常的类型、存在的基础性疾病以及使用过的治疗药物比较,差异均无统计学意义(P>0.05);程控组和非程控组患者的房颤负荷、VP值和P波最小时限均显著小于非程控组,AP值、P波最大时限和P波离散度则显著大于非程控组(P<0.05);程控组和非程控组患者的LAD、RAD、LVEDD和LVEF值在植入前和植入后均不存在显著性差异(P>0.05)。与临床诊断结果比较可以发现,永久起搏器程控对心房颤动检出率为97.44 %,且永久起搏器程控应用于诊断心房颤动敏感度高达98.72 %。结论:对心房颤动患者采用永久起搏器程控进行诊断,可以在心电图检查的各项指标结果上对患者的心房颤动给与准确的判断,具有较高的临床应用价值,值得临床推广使用。  相似文献   