首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 39 毫秒
1.
目的:制作氧化锆基台并将其与钛基台的抗折强度相比较,从而探讨其临床应用的可行性。方法:选用纳米氧化锆粉,采用冷等静压成型和二次烧结工艺制作0sstem USⅡ系统氧化锆基台;选取氧化锆基台和成品钛基台(OSSTEM公司,韩国)各10枚,分别与0sstem USⅡ种植体装配,然后固定于不锈钢夹具中置于万能试验机,将万能试验机压头与种植体长轴成90°角施加压力,记录基台损坏时的加载力值,比较分析两组试件的强度差异。结果:氧化锆基台和钛基台的平均抗折强度分别为(540.5±84.6)N和(753.9±160.8)N,差别有统计学意义(P〈0.05)。氧化锆基台组10枚基台全部颈部折裂;钛基台组2枚种植体损坏,6枚中央固位螺钉损坏,2枚基台颈部折裂。结论:本研究制作的0sstem USⅡ系统的氧化锆基台的抗折强度虽然低于钛基台,但尚能满足临床应用要求。  相似文献   

2.
The aim of this study was to analyze the influence of three different transmucosal heights of the abutments in single and multiple implant-supported prostheses through the finite element method. External hexagon implants, MicroUnit, and EsthetiCone abutments were scanned and placed in an edentulous maxillary model obtained from a tomography database. The simulations were divided into two groups: (1) one implant with 3.75 × 10 mm placed in the upper central incisor, simulating a single implant-supported fixed prosthesis with an EsthetiCone abutment; and (2) two implants with 3.75 × 10 mm placed in the upper lateral incisors with MicroUnit abutments, simulating a multiple implant-supported prosthesis. Subsequently, each group was subdivided into three models according to the transmucosal height (1, 2, and 3 mm). A static oblique load at an angle of 45 degrees to the long axis of the implant in palatal-buccal direction of 150 and 75 N was applied for multiple and single implant-supported prosthesis, respectively. The implants and abutments were assessed according to the equivalent Von Mises stress analyses while the bone and ceramics were analyzed through maximum and minimum principal stresses. The total deformation values increased in all models, while the transmucosal height was augmented. The transmucosal height of the abutments influences the stress values at the bone, ceramics, implants, and abutments of both the single and multiple implant-supported prostheses, with the transmucosal height of 1 mm showing the lowest stress values.  相似文献   

3.
No agreement on the choice of the failure criterion to adopt for the bone tissue can be found in the literature among the finite element studies aiming at predicting fracture risk of bones. The use of stress-based criteria seems to prevail on strain-based ones, while basic bone biomechanics suggest using strain parameters to describe failure. The aim of the present combined experimental-numerical study was to verify, using subject-specific finite element models able to accurately predict strains, if a strain-based failure criterion could identify the failure patterns of bones. Three cadaver femurs were CT-scanned and subsequently fractured in a clinically relevant single-stance loading scenario. Load-displacement curves and high-speed movies were acquired to define the failure load and the location of fracture onset, respectively. Subject-specific finite element models of the three femurs were built from CT data following a validated procedure. A maximum principal strain criterion was implemented in the finite element models, and two stress-based criteria selected for comparison. The failure loads measured were applied to the models, and the computed risks of fracture were compared to the results of the experimental tests. The proposed principal strain criterion managed to correctly identify the level of failure risk and the location of fracture onset in all the modelled specimens, while Von Mises or maximum principal stress criteria did not give significant information. A maximum principal strain criterion can thus be defined a suitable candidate for the in vivo risk factor assessment on long bones.  相似文献   

4.
The surface modifications in teeth increase the retentive strength of cemented castings by providing micro as well as macro retentive ridge and groove patterns. Restoring the dental implants with cement-retained prosthesis is well known. Therefore, it is of interest to compare retentive property of implant abutments with and without circumferential grooves. Hence, 20 straight shoulder type titanium abutments were with abutment screws as well as prefabricated plastic copings and corresponding 12 mm-long stainless steel laboratory implant analogs were used. The abutments were divided into two subgroups of 10 abutments each: without grooves and with grooves. After thermocycling and storing the cemented abutments in water at 37°C water for 6 days they were assembled in the Universal testing machine and subjected to a pullout test (retention) at a crosshead speed of 5.0mm/min to record forces in Newton. Data suggest that the addition of grooves increased the retention. The mean retentive forces of standard machined abutments (plain) cemented with Resin modified GIC showed 339.34 N. Retention increased by 667.39N after addition of circumferential grooves. The surface modification of an implant abutment by means of circumferential grooves is an effective method of improving the retention of cast crowns cemented with resin modified GIC especially in short abutments.  相似文献   

5.
A finite element model of the human dentate mandible has been developed to provide a comparison of fixation systems used currently for fracture reduction. Volume domains for cortical bone, cancellous bone, and teeth were created and meshed in ANSYS 8.0 based on IGES curves created from computerized tomography data. A unilateral molar clench was loaded on the model with a fracture gap simulated along the symphysis. Results based on Von Mises stress in cortical and cancellous bone surrounding the screws, and on fracture surface spatial fixation, show some relative differences between different screw-plate systems, yet all were judged to be appropriate in their reduction potential.  相似文献   

6.
《IRBM》2019,40(6):313-319
BackgroundIn a dental implant/bone system, the design factors affect the value and distributions of stress and deformations that plays a pivotal role on the stability, durability and lifespan of the implant/bone system.ObjectiveThe aim of this study was to compare the influence of different abutment designs on the biomechanical behavior of one-piece zirconia dental implants and their surrounding bone tissues using three-dimensional finite element analysis.MethodsA three-dimensional geometrical model of a zirconia dental implant and its surrounding bone tissue were created. The occlusal loading force applied to the prosthetic abutments was a combination of 114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial direction where these components represent masticatory force of 118.2 N in the angle of approximately 75° to the occlusal plane.ResultsThe system included implant abutment Model 01 showed a decrease of 9.58%, 9.92% and 3.62% at least in the average value of maximum von Mises stress compared to Model 02, Model 03 and Model 04 respectively. The results also showed that the system included implant abutment Model 01 decreases the average value of maximum deformation of 16.96%, 7.17% and 9.47% at least compared to Model 02, Model 03 and Model 04 respectively.ConclusionThe one-piece zirconia dental implant abutment Model 01 presents a better biomechanical behavior in the peri-implant bone than others. It can efficiently distribute the applied load and present more homogeneous behavior of stress distribution and has less deformation than others, which will enhance the stability of implant/bone system and prolong its lifespan.  相似文献   

7.
ObjectiveIn this research it was aimed to evaluate stress distribution on the implants supporting a complete overdenture in addition to compare between two different types of low-profile attachments for implant-retained mandibular overdenture with two techniques (with/without using connecting bar).Materials and methodsTwo 3D finite element models were constructed simulating supported lower complete overdenture with two implants and with two implants and bar. Where, models components were modeled in 3D on commercial general purpose CAD/CAM software. Four runs were carried out, two runs on each model, as linear static analysis.ResultsUsing bar is generally preferred for mucosa and cortical bone, while its effect can be considered as negligible on overdenture. On the other hand, it slightly increases the stresses on spongy bone. Using bar ensures the same level of energy transfer to the spongy bone and increases its maximum Von Mises stresses by about 50%. In addition, increase in maximum Von Mises stress was noticed by about 1% on cortical bone.ConclusionUsing bar is not recommended for patients with flat ridge.  相似文献   

8.
The aim of study was to evaluate the stress distribution in implant-supported prostheses and peri-implant bone using internal hexagon (IH) implants in the premaxillary area, varying surgical techniques (conventional, bicortical and bicortical in association with nasal floor elevation), and loading directions (0°, 30° and 60°) by three-dimensional (3D) finite element analysis. Three models were designed with Invesalius, Rhinoceros 3D and Solidworks software. Each model contained a bone block of the premaxillary area including an implant (IH, Ø4 × 10 mm) supporting a metal-ceramic crown. 178 N was applied in different inclinations (0°, 30°, 60°). The results were analyzed by von Mises, maximum principal stress, microstrain and displacement maps including ANOVA statistical test for some situations. Von Mises maps of implant, screws and abutment showed increase of stress concentration as increased loading inclination. Bicortical techniques showed reduction in implant apical area and in the head of fixation screws. Bicortical techniques showed slight increase stress in cortical bone in the maximum principal stress and microstrain maps under 60° loading. No differences in bone tissue regarding surgical techniques were observed. As conclusion, non-axial loads increased stress concentration in all maps. Bicortical techniques showed lower stress for implant and screw; however, there was slightly higher stress on cortical bone only under loads of higher inclinations (60°).  相似文献   

9.
Turbulent pulsatile flow and wall mechanics were studied numerically in an axisymmetric three-layered wall model of a descending aorta. The transport equations were solved using the finite element formulation based on the Galerkin method of weighted residuals. A fully-coupled fluid–structure interaction (FSI) analysis was utilized in this investigation. We calculated Von Mises wall stress, streamlines and fluid pressure contours. The findings of this study show that peak wall stress and maximum shear stress are highest in the media layer. The difference in the elastic properties of contiguous layers of the wall of the aorta probably determines the occurrence of dissection in the media layer. Moreover, the presence of aortic intramural hematoma is found to have a significant effect on the peak wall stress acting on the inner layer.  相似文献   

10.
Digital image-based finite element modeling (DIBFEM) has become a widely utilized approach for efficiently meshing complex biological structures such as trabecular bone. While DIBFEM can provide accurate predictions of apparent mechanical properties, its application to simulate local phenomena such as tissue failure or adaptation has been limited by high local solution errors at digital model boundaries. Furthermore, refinement of digital meshes does not necessarily reduce local maximum errors. The purpose of this study was to evaluate the potential to reduce local mean and maximum solution errors in digital meshes using a post-processing filtration method. The effectiveness of a three-dimensional, boundary-specific filtering algorithm was found to be mesh size dependent. Mean absolute and maximum errors were reduced for meshes with more than five elements through the diameter of a cantilever beam considered representative of a single trabecula. Furthermore, mesh refinement consistently decreased errors for filtered solutions but not necessarily for non-filtered solutions. Models with more than five elements through the beam diameter yielded absolute mean errors of less than 15% for both Von Mises stress and maximum principal strain. When applied to a high-resolution model of trabecular bone microstructure, boundary filtering produced a more continuous solution distribution and reduced the predicted maximum stress by 30%. Boundary-specific filtering provides a simple means of improving local solution accuracy while retaining the model generation and numerical storage efficiency of the DIBFEM technique.  相似文献   

11.
Prediction of traumatic and mild traumatic brain injury is an important factor in managing their prevention. Currently, the prediction of these injuries is limited to peak linear and angular acceleration loading curves derived from laboratory reconstructions. However it remains unclear as to what aspect of these loading curves contributes to brain tissue damage. This research uses the University College Dublin Brain Trauma Model (UCDBTM) to analyse three distinct loading curve shapes meant to represent different helmet loading scenarios. The loading curves were applied independently in each axis of linear and angular acceleration and their effect on currently used predictors of TBI and mTBI was examined. Loading curve shape A had a late time to peak, B an early time to peak and C had a consistent plateau. The areas under the curve for all three loading curve shapes were identical. The results indicate that loading curve A produced consistently higher maximum principal strains and Von Mises stress than the other two loading curve types. Loading curve C consistently produced the lowest values of maximum principal strain and Von Mises stress, with loading curve B being lowest in only 2 cases. The areas of peak Von Mises stress and Principal strain also varied depending on loading curve shape and acceleration input.  相似文献   

12.
Kong L  Sun Y  Hu K  Liu Y  Li D  Qiu Z  Liu B 《Journal of biomechanics》2008,41(5):1124-1130
In this paper, effects of the implant neck taper and the implant-end fillet on the maximum Von Mises stresses were evaluated in jaw bones, and maximum displacements examined in an implant-abutment complex by a finite element method (FEM). The implant-neck tapers (T) ranged from 45 degrees to 70 degrees , and fillets of implant ends (R) ranged from 0.5 to 1.5mm. Results suggested that under axial load by the maximum Von Mises stresses in cortical and cancellous bones decreased by 71.6% and 14.8%, respectively, and under 45 degrees buccolingual load by 68.2% and 11.0%, respectively. The maximum displacement of implant-abutment complex decreased by 9.1% and 22.8% under axial and 45 degrees buccolingual load, respectively. When T ranged from 64 degrees to 73 degrees and R exceeded 0.8mm, minimum stress/displacement was obtained and the evaluating targets were more sensitive to T than to R. Data indicated that the taper of implant neck favored stress distribution in cortical bones more than the fillet of implant end did; taper of implant neck affected implant stability more than the fillet of implant end did; and the taper of implant neck of 64-73 degrees and fillet of implant end exceeding 0.8mm were optimal selections for the type B/2 bone in a cylinder implant by biomechanical consideration.  相似文献   

13.
目的建立人体髋臼骨结核三维有限元模型,探讨不同部位髋臼骨结核软骨下骨塌陷的风险。方法通过正常髋关节CT数据,利用Mimics软件和ANSYS有限元软件,建立正常髋关节三维有限元模型(模型A)、髋臼顶部骨结核(模型B)、髋臼中心部骨结核(模型C)、髋臼前部骨结核(模型D)、髋臼后部骨结核(模型E)三维有限元模型,模拟人体单脚站立进行加载,分析髋臼软骨下骨峰值Von Mises应力和初始微动值。结果建立了正常髋关节和不同部位髋臼骨结核三维有限元模型,各模型含节点269284,三维四面体单元184786个。通过加载分析结果显示:与正常髋关节相比,峰值Von Mises应力,依次增加84%、3%、21%、67%;髋臼软骨下骨初始微动值依次增加66%、11%、17%、29%。结论髋臼顶部结核软骨下骨峰值Von Mises应力和初始微动值最大,塌陷的风险最大。  相似文献   

14.
The aim of this study was to evaluate the influence of pontic and cantilever designs (mesial and distal) on 3-unit implant-retained prosthesis at maxillary posterior region verifying stress and strain distributions on bone tissue (cortical and trabecular bones) and stress distribution in abutments, implants and fixation screws, under axial and oblique loadings, by 3D finite element analysis. Each model was composed of a bone block presenting right first premolar to the first molar, with three or two external hexagon implants (4.0 × 10 mm), supporting a 3-unit splinted dental fixed dental prosthesis with the variations: M1 – three implants supporting splinted crowns; M2 – two implants supporting prosthesis with central pontic; M3 – two implants supporting prosthesis with mesial cantilever; M4 – two implants supporting prosthesis with distal cantilever. The applied forces were 400 N axial and 200 N oblique. The von Mises criteria was used to evaluate abutments, implants and fixation screws and maximum principal stress and microstrain criteria were used to evaluate the bone tissue. The decrease of the number of implants caused an unfavorable biomechanical behavior for all structures (M2, M3, M4). For two implant-supported prostheses, the use of the central pontic (M2) showed stress and strain distributions more favorable in the analyzed structures. The use of cantilever showed unfavorable biomechanical behavior (M3 and M4), mainly for distal cantilever (M4). The use of three implants presented lower values of stress and strain on the analyzed structures. Among two implant-supported prostheses, prostheses with cantilever showed unfavorable biomechanical behavior in the analyzed structures, especially for distal cantilever.  相似文献   

15.
Few studies are performed to evaluate the influence of connection type on the stress distribution of distal extension mandibular removable partial dentures (RPDs) supported by both implants and natural teeth. In this study, five three-dimensional finite element models were prepared to simulate mandibular bilateral partially edentulous arches. Four were RPDs supported by both implants and natural teeth, and the other one was RPDs supported only by natural teeth. The maximum equivalent (EQV) stress values of bone around implants, the abutments, and the mucosa displacements of the related supporting structures were measured. It was found that a non-rigid telescopic coping was more favorable to protect the implant than a rigid telescopic coping. Compared with other connection types, the easy resilient attachment (ERA) system seemed to be effective to associate implant without complications. However, the results obtained in the present study should be cautiously interpreted in the clinic.  相似文献   

16.
Although asymmetric yielding in bone is widely shown in experimental studies, previous case-specific non-linear finite element (FE) studies have mainly adopted material behaviour using the Von Mises yield criterion (VMYC), assuming equal bone strength in tension and compression. In this study, it was verified that asymmetric yielding in FE models can be captured using the Drucker-Prager yield criterion (DPYC), and can provide better results than simulations using the VMYC. A sensitivity analysis on parameters defining the DPYC (i.e. the degree of yield asymmetry and the yield stress settings) was performed, focusing on the effect on bone failure. In this study, the implementation of a larger degree of yield asymmetry improved the prediction of the fracture location; variations in the yield stress mainly affected the predicted failure force. We conclude that the implementation of asymmetric yielding in case-specific FE models improves the prediction of femoral bone strength.  相似文献   

17.
In post-core crown restorations, the significant mismatch between stiffness of artificial crowns and dental tissues leads to stress concentration at the interfaces. The aim of the present study was to reduce the destructive stresses by using a class of inhomogeneous materials called functionally graded materials (FGMs). For the purpose of the study, a 3-dimentional computer model of a premolar tooth and its surrounding tissues were generated. A post-core crown restoration with various crown materials, homogenous and FGM materials, were simulated and analyzed by finite element method. Finite element and statistical analysis showed that, in case of oblique loading, a significant difference (p < 0.05) was found at the maximum von Mises stresses of the crown margin between FGM and homogeneous crowns. The maximum von Mises stresses of the crown margin generated by FGM crowns were lower than those generated by homogenous crowns (70.8 vs. 46.3 MPa) and alumina crown resulted in the highest von Mises stress at the crown margin (77.7 MPa). Crown materials of high modulus of elasticity produced high stresses at the cervical region. FGM crowns may reduce the stress concentration at the cervical margins and consequently reduce the possibility of fracture.  相似文献   

18.
The objective of this study was to predict time-dependent bone remodeling around tissue- and bone-level dental implants used in patients with reduced bone width. The remodeling of bone around titanium tissue-level, and titanium and titanium–zirconium alloy bone-level implants was studied under 100 N oblique load for one month by implementing the Stanford theory into three-dimensional finite element models. Maximum principal stress, minimum principal stress, and strain energy density in peri-implant bone and displacement in x- and y- axes of the implant were evaluated. Maximum and minimum principal stresses around tissue-level implant were higher than bone-level implants and both bone-level implants experienced comparable stresses. Total strain energy density in bone around titanium implants slightly decreased during the first two weeks of loading followed by a recovery, and the titanium–zirconium implant showed minor changes in the axial plane. Total strain energy density changes in the loading and contralateral sides were higher in tissue-level implant than other implants in the cortical bone at the horizontal plane. The displacement values of the implants were almost constant over time. Tissue-level implants were associated with higher stresses than bone-level implants. The time-dependent biomechanical outcome of titanium–zirconium alloy bone-level implant was comparable to the titanium implant.  相似文献   

19.
The aim of this study was to investigate the stress distribution generated in a veneer restoration of an upper central incisor compared to intact teeth using the finite element analysis after applying a lingual buccal loading at the incisal edge. Methods: Two models were developed: one model contained enamel, dentine, cementum, periodontal ligament, cortical and trabecullar bones, and the other model was a veneer restoration; both models were developed using MSC/Nastran software (MacNeal-Schwendler Corporation, Los Angeles, CA, USA) as the pre- and post-processor. A 10-N load was applied at the incisal edge from the lingual to the buccal side to simulate oral conditions in this area (protrusion). Results: Von Mises stresses were then analysed for three different regions: A-B (enamel elements under the veneer or second enamel layer), A'-B' (buccal enamel and/or veneer element layer) and C-D (lingual enamel elements layer). A higher stress mode was observed for both models at the lingual cervical region. Conclusions: The presence of a veneer restoration on the incisors is a good alternative to mimic the behaviour of enamel under protrusion loading conditions. The use of veneers to replace enamel during rehabilitations is recommended.  相似文献   

20.
《Journal of biomechanics》2014,47(15):3734-3743
In this study, a three-dimensional finite element model was used to investigate the changes in tissue composition and mechanical signals within human lumbar intervertebral disc during the degenerative progression. This model was developed based on the cell-activity coupled mechano-electrochemical mixture theory. The disc degeneration was simulated by lowering nutrition levels at disc boundaries, and the temporal and spatial distributions of the fixed charge density, water content, fluid pressure, Von Mises stress, and disc deformation were analyzed. Results showed that fixed charge density, fluid pressure, and water content decreased significantly in the nucleus pulposus (NP) and the inner to middle annulus fibrosus (AF) regions of the degenerative disc. It was found that, with degenerative progression, the Von Mises stress (relative to that at healthy state) increased within the disc, with a larger increase in the outer AF region. Both the disc volume and height decreased with the degenerative progression. The predicted results of fluid pressure change in the NP were consistent with experimental findings in the literature. The knowledge of the variations of temporal and spatial distributions of composition and mechanical signals within the human IVDs provide a better understanding of the progression of disc degeneration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号