首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.

Background

Paroxysmal atrial fibrillation (PAF) is defined as recurrent AF terminating spontaneously within 7 days. This definition allows the consideration of any AF occurrence lasting < 7 days as paroxysmal, irrespective of the frequency and duration of episodes. The aim of this study was to investigate symptomatic AF burden (AFB) defined as total duration of symptomatic AF episodes within 3 months prior to abalation, for prediction of outcome after pulmonary vein isolation (PVI).

Methods

A total of 320 consecutive patients with symptomatic AF (PAF=244, men=214, age=58 y) were enrolled. AFB in patients with PAF was defined as time spent in AF within 3 months prior to PVI. After the AFB cut-off point was optimized at 500 h, patients with PAF were categorized into 2 groups: Group 1 - patients with AFB< 500 h (n=192), Group 2 - patients with AFB≥ 500 h (n=52). Patients with persistent AF (PersAF, n = 76) comprised control group (Group 3). PVI was performed either with irrigated tip catheter (n=215) or using cryoballoon (n=105). The endpoint of study was first documented recurrence of AF >30 sec.

Results

Symptomatic AFB was found to be appropriate for prediction of outcome after PVI. The freedom from AF within 2 years was observed in 69%, 31%, and 43% patients in Group 1, 2 and 3, respectively (Group 1 vs. Group 2, p < .001; Group 1 vs. Group 3, p< .001; Group 2 vs. Group 3, p = 0.46).

Conclusions

Low AFB < 500 h /3 months was associated with better outcome after PVI. Patients with PAF and high AFB should be treated as patients with PersAF.  相似文献   

2.

Objectives

Left atrium (LA) plays an important role in left ventricular filling. It is well known that right ventricular apical pacing has unfavorable effects on ventricular systolic and diastolic performance. The aim of this study is to evaluate the LA mechanical functions with 2D echocardiography in patients with a permanent pacemaker after short time ventricular pacing.

Design

Echocardiographic examination was performed in 38 patients (mean age 63.0± 10.9, 18 female) with dual chamber pacemakers or defibrillators (< 20% ventricular pacing within previous 6 months, all of them on sinus rhythm) before and after 4 hours > 90% ventricular pacing at 70 beats per minute in DDD mode with an optimal AV interval. Left atrial volumes (LAV) including at the time of mitral valve opening (Vmax), at closure (Vmin), and at the onset of atrial systole (Volp) were measured. The passive emptying, conduit, active emptying and total emptying volume, stroke volumes were also calculated.

Results

No significant differences were noted at baseline and after pacing for absolute Vmax, Volp, passive emptying, conduit, active emptying, total emptying volumes as well as the volumes indexed to body surface area (p >0.05).

Conclusions

Short - time RV pacing seems to have no acute effects on left atrial mechanical functions.  相似文献   

3.

Aims

To evaluate the effects of pulmonary vein isolation (PVI) in terms of feasibility, safety and success rate on a midterm follow-up period in septuagenarians undergoing ablation with the Arctic Front Cryoballoon for atrial fibrillation (AF).

Methods and Results

We prospectively enrolled 21 patients aged 70 years or older (14 male; age 73 ± 2.5 years) elected to circumferential PVI with the 28mm cryoballoon for symptomatic drug resistant paroxysmal AF. A total number of 82 pulmonary veins (PV) were evidenced. Successful isolation could be obtained in all 82 (100%) PV ostia at the end of procedure. No major complication occurred during procedure. At a mean follow-up of 11.5 ± 4.7 months following ablation, 62% of patients did not present recurrence of atrial arrhythmias.

Conclusion

Cryoballoon ablation may be feasible and safe in older patients. Moreover a large proportion of the latter did not present AF recurrence during follow-up.  相似文献   

4.

Introduction

The aim of this study was to evaluate the differences in quality of life and psychosocial stress parameters among patients with paroxysmal atrial fibrillation (AF) and common forms of atrioventricular reentry supraventricular tachycardias (SVTs).

Methods and Results

The total study population included 106 patients, 54 patients with paroxysmal AF (32 males, age 56.64±12.50 years) and 52 with SVTs (25 males, age 40.46±14.96 years). General health (p<0.01), physical function (p=0.004), role emotion (p=0.002) and role physical (p<0.01) scores were lower in patients who suffered AF. SF-36 physical and mental health summary measures were also significantly lower in the AF group compared to those in SVT group (p<0.01 and p=0.001, respectively). Lower SF-36 total score was observed in patients with AF compared to those with SVTs (p<0.01). Comparing the anxiety and depression scores all the values were higher in patients with AF. Higher STAI-state scores (p<0.01), STAI-trait scores (p=0.039) and BDI scores (p=0.077) were seen in patients who suffered AF comparing to those with SVTs.

Conclusions

Quality of life is significantly impaired and the level of anxiety is significantly higher in patients with AF comparing to those with common forms of SVTs.  相似文献   

5.

Background

Ganglionated plexi (GP) ablation has been become an adjunct to pulmonary vein isolation (PVI). This study describes the long-term results of minimally invasive surgical PVI, ablation of GPs, and exclusion of the left atrial appendage for atrial fibrillation (AF).

Methods

Long-term follow-up of 55 months was performed in 139 consecutive patients (age 58.3±20.8 years) with symptomatic, drug-refractory lone AF who underwent minimally invasive surgical PVI, GPs ablation, and exclusion of the left atrial appendage. Success was defined as freedom from AF, atrial flutter, or atrial tachycardia off antiarrhythmic drugs.

Results

AF was paroxysmal in 77.7%, persistent in 12.2% and long-standing persistent in 10.1%. Single-procedure success rate was 71.7%, 59.4% and 46.6% at 12, 24 and 60 months respectively. Single-procedure success rate was 72.9%, 62.6% and 51.8% for paroxysmal AF, 64.7%, 35.3%, and 28.2% for persistent AF, 71.4%, 64.3% and 28.6% for long-standing persistent AF at 12, 24 and 60 months respectively. Duration of AF>24 months (hazard ratio [HR]: 3.09, 95% confidence interval [CI]: 1.51 to 6.32; p = 0.002), left atrial diameter≥40 mm (HR: 4.03, 95% CI: 1.88 to 8.65; p<0.001), early recurrence of AF (HR: 4.66, 95% CI: 2.25 to 9.63; p<0.001) independently predicted long-term recurrence of AF. There was no procedure-related death. One patient converted to median sternotomy because of uncontrolled bleeding. Two patients underwent perioperative cerebrovascular events.

Conclusions

At nearly 5-year of clinical follow-up, single-procedure success rate of minimally invasive surgical PVI with GP ablation was 51.8% for paroxysmal AF, 28.2% for persistent AF, 28.6% for long-standing persistent AF after initial procedure. Patients with AF duration≤24 months, left atrial diameter<40 mm and no early recurrence of AF, had favorable outcomes.  相似文献   

6.

Background

Cryoballoon-based pulmonary vein isolation (PVI) is a treatment option for atrial fibrillation (AF). Left atrial volume (LAV) and left atrial volume index (LAVi) are important parameters for long term success of PVI. Galectin-3 (Gal-3) and neutrophil to lymphocyte ratio (N/L ratio) are biomarkers to demonstrate the cardiac fibrosis and remodelling.

Methods

50 patients with symptomatic PAF despite ≥1 antiarrhythmic drug(s), who underwent PVI were enrolled. LAV, LAVi, Gal-3 and N/L ratio were calculated before ablation and after ablation at 6 and 12 months. According to AF recurrence patients were divided into two groups, recurrent AF (n?=?14) and non-recurrent AF (n?=?36).

Results

In both groups (recurrent and non-recurrent), initial and 12 months follow-up LAV values were 41.39?±?18.13?ml and 53.24?±?22.11?ml vs 48.85?±?12.89?ml and 42.08?±?13.85 (p?=?0.037). LAVi were 20.9?±?8.91 ml/m2 and 26.85?±?11.28 ml/m2 vs 25.36?±?6.21 and 21.87?±?6.66 (p?=?0.05) for recurrent and non-recurrent AF groups, respectively. In both groups PVI had no significant effect on serum Gal-3 levels and N/L ratio during 12 months follow-up. The comparison between two groups at the end of 12th month showed Gal-3 values of 6.66?±?4.09?ng/ml and 6.02?±?2.95?ng/ml (p?=?0.516), N/L ratio values of 2.28?±?1.07 103/μl and 1.98?±?0.66?103/μl (p?=?0.674).

Conclusion

LAV and LAVi are useful to predict the remodelling of the left atrium and AF recurrence after cryoballoon-based PVI. However, biomarkers such as Gal-3 and N/L ratio are not associated with AF recurrence.  相似文献   

7.

Background

Silent cerebral events (SCE) have been identified on magnetic resonance imaging (MRI) in asymptomatic patients after atrial fibrillation (AF) ablation. Procedural determinants influencing the risk for SCE still remain unclear.

Objective

Comparing the risk for SCE depending on exchanges of catheters (ExCath) over a single transseptal sheath.

Methods

88 Patients undergoing pulmonary vein isolation (PVI) only ablation using either single-tip or balloon-based technique underwent pre- and post-ablation cerebral MRI. Ablations were either performed with double transseptal access and without exchanging catheters over the transseptal sheaths (group 1: no ExCath) or after a single transseptal access and exchanges of therapeutic and diagnostic catheters (group 2: ExCath). Differences in regard to SCE rates were analyzed. Multivariate analysis was performed to identify factors related to the risk for SCE.

Results

Included patients underwent PVI using single tip irrigated radiofrequency in 41, endoscopic laser balloon in 27 and cryoballoon in 20 cases. Overall SCE were identified in 23 (26%) patients. In group 1 (no ExCath; N=46) 6 patients (13%) and in group 2 (N=42) 17 patients (40%) had documented SCE (p=0.007). The applied ablation technology did not affect SCE rate. In multivariate analysis age (OR 1.1, p=0.03) and catheter exchanges over a single transseptal sheath (OR 12.1, p=0.007) were the only independent predictors of a higher risk for SCE.

Conclusions

Exchanging catheters over a single transseptal access to perform left atrial ablation is associated with a significantly higher incidence of SCE compared to an ablation technique using different transseptal accesses for therapeutic and diagnostic catheters.  相似文献   

8.

Background

Left atrial (LA) enlargement is a predictor of worse outcome after catheter ablation for atrial fibrillation (AF). Widely used two-dimensional (2D)-echocardiography is inaccurate and underestimates real LA volume (LAV). We hypothesized that baseline clinical characteristics of patients can be used to adjust 2D-ECHO indices of LAV in order to minimize this disagreement.

Methods

The study enrolled 535 patients (59 ± 9 years; 67% males; 43% paroxysmal AF) who underwent catheter ablation for AF in three specialized centers. We investigated multivariately the relationship between 2D-echocardiographic indices of LA size, specifically LA diameter in M-mode in the parasternal long-axis view (LAD), LAV assessed by the prolate-ellipsoid method (LAVEllipsoid), LAV by the planimetric method (LAVPlanimetry), and LAV derived from 3D-electroanatomic mapping (LAVCARTO).

Results

Cubed LAD of 106 ± 45 ml, LAVEllipsoid of 72 ± 24 ml and LAVPlanimetry of 88 ± 30 ml correlated only modestly (r = 0.60, 0.69, and 0.53, respectively) with LAVCARTO of 137 ± 46 ml, which was significantly underestimated with a bias (±1.96 standard deviation) of -31 (-111; +49) ml, -64 (-132; +2) ml, and -49 (-125; +27) ml, respectively; p < 0.0001 for their mutual difference. LA enlargement itself, age, gender, type of AF, and the presence of structural heart disease were independent confounders of measurement error of 2D-echocardiographic LAV.

Conclusion

Accuracy and precision of all 2D-echocardiographic LAV indices are poor. Their agreement with true LAV can be significantly improved by multivariate adjustment to clinical characteristics of patients.  相似文献   

9.

Background

The aim of the study was to compare in our center the effect of different ablation techniques on intermediate term freedom from atrial fibrillation (AF) or atrial tachycardia (AT) in patients affected by refractory AF.

Methods and Results

We retrospectively selected 94 patients who underwent AF ablation in our electrophysiological laboratory from June 2007 to December 2009. 29 patients underwent manual circumferential pulmonary vein isolation (mCPVI), 35 underwent remote magnetic navigation assisted CPVI (rmtCPVI) and 30 cryoballoon CPVI (cCPVI). Antiarrhythmic drugs were systematically stopped 2 months after the procedure (end of the "blanking period").At a mean follow-up of 12,64 ± 6,41 months (range 2-31), the success rate for mCPVI group was 65.5% (19 patients), 66.7 % (20 patients) for the rmtCPVI group and 65.7 % (23 patients) for the cCPVI group (p = 0.625). Procedural and fluoroscopy times were significantly reduced in the cCPVI group (both p < 0.001). Univariate Cox regression showed that no clinical variables were independently associated with recurrence.

Conclusions

In our center''s experience cCPVI and rmtCPVI have been demonstrated to be as effective as mCPVI. cCPVI seemed to be associated with lower procedural and fluoroscopy times.  相似文献   

10.
Stiff left atrial (LA) syndrome was initially reported in post-cardiac surgery patients and known to be associated with low LA compliance. We investigated the physiological and clinical implications of LA compliance by estimating LA pulse pressure (LApp) among patients with atrial fibrillation (AF) and structurally and functionally normal heart. Among 1038 consecutive patients with LA pressure measurements before AF ablation, we included 334 patients with structurally and functionally normal heart (81.7% male, 54.1±10.6 years, 77.0% paroxysmal AF) after excluding those with hypertension, diabetes, and previous ablation or cardiac surgery. We measured LApp (peak-nadir LA pressure) at the beginning of the ablation procedure and compared the values with clinical parameters and the AF recurrence rate.AF patients with normal heart were younger and more frequently male and had paroxysmal AF, a lower body mass index, and a lower LApp compared to others (all p<0.05).Based on the median value, the low LA compliance group (LApp≥13mmHg) had a smaller LA volume index and lower LA voltage (all p<0.05) compared to the high LA compliance group. During a mean follow-up of 16.7±11.8 months, low LA compliance was independently associated with two fold-higher risk of clinical AF recurrence (HR:2.202; 95%CI:1.077–4.503; p = 0.031).Low LA compliance, as determined by an elevated LApp, was associated with a smaller LA volume index and lower LA voltage and independently associated with higher clinical recurrence after catheter ablation in AF patients with structurally and functionally normal heart.  相似文献   

11.

Background

In patients undergoing coronary artery bypass surgery (CABGS), occurrence of atrial fibrillation (AF) is common in the postoperative period and is associated with increased morbidity with longer intensive unit care (ICU) and hospital stay. Prevention with antiarrhythmic drugs is of limited success and associated with significant side effects. Therefore alternative approaches, such as Bachmann Bundle pacing, are required.

Methods and Results

154 consecutive patients, mean age 58±8.8 years, including 134 males and 20 females, were randomized to three groups; Group I : No pacing n= 54, Group II : RA pacing n= 52, Group III : Bachmann Bundle pacing n= 48. All the groups were well matched with regard to age, left atrial size, ejection fraction and use of beta blockers. Patients in Groups II and III were continually paced at a rate of 100 beats per minute (bpm) or at 10 bpm more than patients'' intrinsic heart rate. All the patients were monitored for 72 hours by telemetry and occurrence of AF was noted. Incidence of AF was 0% (none of 48 patients) in Group III as compared to 16.6% in Group I (9 of 54 patients) (p 0.003) and 12.5% in Group II (5 of 52 patients) (p 0.03). There was a trend towards shorter ICU stay in Group III (3.9 days) as compared to Group II (4.5 days) and Group I (4.1 days). Among the three groups, the reduction in mean P wave duration also was greater in Bachmann bundle paced group.

Conclusion

In patients undergoing CABGS, Bachmann bundle pacing is superior to right atrial / no pacing in the post operative period for preventing occurrence of AF and reducing ICU stay, commensurate with a reduction in mean P wave duration on surface ECG.  相似文献   

12.

Background

Atrial fibrillation (AF) is the most common arrhythmia encountered in clinical practice. Elective electrical cardioversion is often performed in patients with persistent AF to attempt sinus rhythm (SR) restoration. However, AF recurrences are frequent after successful cardioversion and several predictors have been identified.

Aim of the study

The present study was designed to prospectively analyse the correlation between NT-pro-BNP levels and AF recurrence in consecutive patients referred for electrical cardioversion of persistent atrial fibrillation.

Results

Forty consecutive patients referred for elective cardioversion of AF were enrolled in the study. Cardioversion restored sinus rhythm in 34/40 patients but 2 of them presented an early recurrence of AF before discharge. Patients were then followed for 6 months to assess AF recurrence. Cox regression analysis was performed using the parameters found predictive on univariate survival analysis (NT-pro-BNP quartiles, beta-blockers). The only independent predictor of AF recurrence on Cox-regression analysis was a level of NT-pro-BNP in the fourth quartile (HR 3.21 95%CI 1.26-8.14, p=0.014). On receiver operating curve (ROC) analysis, NT-pro-BNP levels above 1707 pg/ml had a specificity of 92% (and a sensitivity of 36%) in predicting atrial fibrillation recurrence by 6 months.

Conclusions

Baseline NT-pro-BNP levels are an independent predictor of AF recurrence at 6 months follow-up in candidates for elective direct current cardioversion.  相似文献   

13.

Background

Paroxysmal atrial tachyarrhythmias frequently occur in beta-thalassemia major (β-TM) patients.The aim of our study was to investigate the role of maximum P-wave duration (P max) and dispersion (PD), calculated trough a new manually performed measurement with the use of computer software from all 12-ECG-leads,as predictors of atrial-fibrillation (AF) in β-TM patients with conserved systolic or diastolic cardiac function during a twelve-months follow-up.

Materials and Methods

50 β-TM-patients (age38.4±10.1; 38M) and 50-healthy subjects used as controls, matched for age and gender, were studied for the occurrence of atrial arrhythmias during a 1-year follow-up, through ECG-Holter-monitoring performed every three months. The β-TM-patients were divided into two groups according to number and complexity of premature-supraventricular-complexes at the Holter-Monitoring (Group1: <30/h and no repetitive forms, n:35; Group2: >30/h or couplets, or run of supraventricular tachycardia and AF, n:15).

Results

Compared to the healthy control-group, β-TM patients presented increased P-max (107.5± 21.2 vs 92.1±11ms, P=0.03) and PD-values (41.2±13 vs 25.1±5 ms,P=0.03). In the β-TM population, the Group2 showed a statistically significant increase in PD (42.8±8.6 vs 33.2±6.5ms, P<0.001) and P-max (118.1±8.7 vs 103.1±7.5ms, P<0.001) compared to the Group1. Seven β-TM patients who showed paroxysmal AF during this study had significantly increased P-max and PD than the other patients of the Group2. Moreover, P-max (OR:2.01; CI:1.12-3.59; P=0.01) and PD (OR=2.06;CI:1.17-3.64;P=0.01) demonstrated a statistically significant association with the occurrence of paroxysmal AF,P min was not associated with AF-risk (OR=0.99; CI:0.25-3.40; P=0.9) in β-TM-patients. A cut-off value of 111ms for P-max had a sensitivity of 80% and a specificity of 87%, a cut-off value of 35.5ms for PD had a sensitivity of 90% and a specificity of 85% in identifying β-TM patients at risk for AF.

Conclusion

Our results indicate that P-max and PD are useful electrocardiographic markers for identifying the β-TM-high-risk patients for AF onset, even when the cardiac function is conserved.  相似文献   

14.

Background

Our aim was to assess how atrial fibrillation (AF) induction, chronicity, and RR interval irregularity affect left atrial (LA) function and size in the setting of underlying heart failure (HF), and to determine whether AF effects can be mitigated by vagal nerve stimulation (VNS).

Methods

HF was induced by 4-weeks of rapid ventricular pacing in 24 dogs. Subsequently, AF was induced and maintained by atrial pacing at 600 bpm. Dogs were randomized into control (n = 9) and VNS (n = 15) groups. In the VNS group, atrioventricular node fat pad stimulation (310 μs, 20 Hz, 3–7 mA) was delivered continuously for 6 months. LA volume and LA strain data were calculated from bi-weekly echocardiograms.

Results

RR intervals decreased with HF in both groups (p = 0.001), and decreased further during AF in control group (p = 0.014), with a non-significant increase in the VNS group during AF. LA size increased with HF (p<0.0001), with no additional increase during AF. LA strain decreased with HF (p = 0.025) and further decreased after induction of AF (p = 0.0001). LA strain decreased less (p = 0.001) in the VNS than in the control group. Beat-by-beat analysis showed a curvilinear increase of LA strain with longer preceding RR interval, (r = 0.45, p <0.0001) with LA strain 1.1% higher (p = 0.02) in the VNS-treated animals, independent of preceding RR interval duration. The curvilinear relationship between ratio of preceding and pre-preceding RR intervals, and subsequent LA strain was weaker, (r = 0.28, p = 0.001). However, VNS-treated animals again had higher LA strain (by 2.2%, p = 0.002) independently of the ratio of preceding and pre-preceding RR intervals.

Conclusions

In the underlying presence of pacing-induced HF, AF decreased LA strain, with little impact on LA size. LA strain depends on the preceding RR interval duration.  相似文献   

15.

Background

Atrial fibrillation (AF) can be managed with rhythm- or rate-control strategies. There are few data from routine clinical practice on the frequency with which each strategy is used and their correlates in terms of patients’ clinical characteristics, AF control, and symptom burden.

Methods

RealiseAF was an international, cross-sectional, observational survey of 11,198 patients with AF. The aim of this analysis was to describe patient profiles and symptoms according to the AF management strategy used. A multivariate logistic regression identified factors associated with AF management strategy at the end of the visit.

Results

Among 10,497 eligible patients, 53.7% used a rate-control strategy, compared with 34.5% who used a rhythm-control strategy. In 11.8% of patients, no clear strategy was stated. The proportion of patients with AF-related symptoms (EHRA Class > = II) was 78.1% (n = 4396/5630) for those using a rate-control strategy vs. 67.8% for those using a rhythm-control strategy (p<0.001). Multivariate logistic regression analysis revealed that age <75 years or the paroxysmal or persistent form of AF favored the choice of a rhythm-control strategy. A change in strategy was infrequent, even in patients with European Heart Rhythm Association (EHRA) Class > = II.

Conclusions

In the RealiseAF routine clinical practice survey, rate control was more commonly used than rhythm control, and a change in strategy was uncommon, even in symptomatic patients. In almost 12% of patients, no clear strategy was stated. Physician awareness regarding optimal management strategies for AF may be improved.  相似文献   

16.

Introduction

The advent of electroanatomical mapping (EAM) systems for pulmonary vein isolation (PVI) has dramatically decreased radiation exposure. However, the need for some fluoroscopy remains for obtaining left atrial (LA) access. The aim was to test the feasibility of fluoroscopy-free PVI in patients with atrial fibrillation (AF) and a patent foramen ovale (PFO) guided solely by an EAM system.

Methods

Consecutive patients with AF undergoing PVI and documented PFO were studied. An EAM-guided approach without fluoroscopy and ultrasound was used. After completing the map of the right atrium, the superior vena cava and the coronary sinus, a catheter pull-down to the PFO was performed allowing LA access. The map of the LA and subsequent PVI was also performed without fluoroscopy.

Results

30 patients [age 61±12 years, 73% male, ejection fraction 0.64 (0.53–0.65), LA size in parasternal long axis 38±7 mm] undergoing PVI were included. The time required for right atrial mapping including transseptal crossing was 9±4 minutes. Total procedure time was 127±37 minutes. Fluoroscopy-free PVI was feasible in 26/30 (87%) patients. In four patients, fluoroscopy was needed to access (n = 3) or to re-access (n = 1) the LA. In these four patients, total fluoroscopy time was 5±3 min and the DAP was 14.9±13.4 Gy*cm2. Single-procedure success rate was 80% (24/30) after a median follow-up of 12 months.

Conclusion

In patients with a documented PFO, completely fluoroscopy-free PVI is feasible in the vast majority of cases.  相似文献   

17.

Background

Galectin-3 (Gal-3) is an emerging biomarker in heart failure that is involved in fibrosis and inflammation. However, its potential value as a prognostic marker in atrial fibrillation (AF) is unknown. The aim of this study was to assess the impact of AF catheter ablation on Gal-3 and evaluate its prognostic impact for predicting rhythm outcome after catheter ablation.

Methods

Gal-3 was measured at baseline and after 6 months using specific ELISA. AF recurrences were defined as any atrial arrhythmia lasting longer than 30 sec within 6 months after ablation.

Results

In 105 AF patients (65% males, age 62±9 years, 52% paroxysmal AF) undergoing catheter ablation, Gal-3 was measured at baseline and after 6 months and compared with an AF-free control cohort (n=14, 50 % males, age 58±11 years). Gal-3 was higher in AF patients compared with AF-free controls (7.8±2.9 vs. 5.8±1.8, ng/mL, p=0.013). However, on multivariable analysis, BMI (p=0.007) but not AF (p=0.068) was associated with Gal-3. In the AF cohort, on univariable analysis higher Gal-3 levels were associated with female gender (p=0.028), higher BMI (p=0.005) and both CHADS2 (p=0.008) and CHA2DS2-VASC (p=0.016) scores, however, on multivariable analysis only BMI remained significantly associated with baseline Gal-3 (p=0.016). Gal-3 was similar 6 months after AF catheter ablation and was not associated with sinus rhythm maintenance.

Conclusions

Although galectin-3 levels are higher in AF patients, this is driven by cardiometabolic co-morbidities and not heart rhythm. Gal-3 is not useful for predicting rhythm outcome of catheter ablation.  相似文献   

18.

Objectives

Atrial fibrillation (AF) is a significant public health issue due to its high prevalence in the general population, and is associated with an increased risk of cardiovascular (CV) events including systemic thrombo-embolism, heart failure, and coronary artery disease. The relationship between plasma B-type natriuretic peptide (BNP) and CV risk in real world AF subjects remains unknown.

Methods

The subject of the study (n = 228; mean age = 69 years) was unselected individuals with AF in a community-based population (n = 15,394; AF prevalence rate = 1.5%). The CV event free rate within each BNP tertile was estimated, and Cox regression analysis was performed to examine the relative risk of the onset of CV events among the tertiles. The prognostic ability of BNP was compared to an established risk score for embolic events (CHADS2 score). In addition, to determine the usefulness of BNP as a predictor in addition to CHADS2 score, we calculated Net Reclassification Improvement (NRI) and Integrated Discrimination Improvement (IDI) indices.

Results

During the follow-up period 58 subjects experienced CV events (52 per 1,000 person-years). The event-free ratio was significantly lower in the highest tertile (p < 0.02). After adjustment for established CV risk factors, the hazard ratio (HR) of the highest tertile was significantly higher than that of the lowest tertile (HR = 2.38; p < 0.02). The predictive abilities of plasma BNP in terms of sensitivity and specificity for general CV events were comparable to those of CHADS2 score. Adding BNP to the CHADS2 score only model improved the NRI (0.319; p < 0.05) and the IDI (0.046; p < 0.05).

Conclusion

Plasma BNP is a valuable biomarker both singly or in combination with an established scoring system for assessing general CV risk including stroke, heart failure and acute coronary syndrome in real-world AF subjects.  相似文献   

19.

Background

Autonomic fluctuations are associated with the initiation and possibly maintenance of atrial fibrillation (AF). However, little is known about the relationship between orthostatic blood pressure change, a common manifestation of autonomic dysfunction, and incident AF.

Methods

We examined whether supine-to-standing changes in systolic blood pressure (SBP) are associated with incident AF in 12,071 African American and white men and women aged 45–64 years, enrolled in the Atherosclerosis Risks in Communities (ARIC) study. Orthostatic hypotension (OH) was defined as a supine-standing drop in SBP by ≥20 mmHg or diastolic blood pressure by ≥10 mmHg. AF cases were identified based on study scheduled 12-lead ECG, hospital discharge ICD codes, and death certificates through 2009.

Results

OH was seen in 603 (5%) at baseline. During an average follow-up of 18.1 years, 1438 (11.9%) study participants developed AF. Incident AF occurred more commonly among those with OH than those without, a rate of 9.3 vs. 6.3 per 1000 person years, (p<0.001). The age, gender, and race adjusted hazard ratio (95%CI) of AF among those with OH compared to those without was 1.62 (1.34, 2.14). This association was attenuated after adjustment for common AF risk factors to HR 1.40 (1.15, 1.71), a strength similar to that of diabetes or hypertension with AF in the same model. A non-linear relationship between orthostatic change in SBP and incident AF was present after multivariable adjustment.

Conclusions

OH is associated with higher AF incidence. Whether interventions that decrease OH can reduce AF risk remains unknown.  相似文献   

20.

Background

Colorectal cancer (CRC) and atrial fibrillation/flutter (AF) share several risk factors including increasing age and obesity. However, the association between CRC and AF has not been thoroughly examined, especially in African Americans. In this study we aimed to assess the prevalence of AF and its risk factors in colorectal neoplasia in an African American.

Methods

We reviewed records of 527 African American patients diagnosed with CRC and 1008 patients diagnosed with benign colonic lesions at Howard University Hospital from January 2000 to December 2012. A control group of 731 hospitalized patients without any cancer or colonic lesion were randomly selected from the same time and age range, excluding patients who had diagnosis of both CRC and/or adenoma. The presence or absence of AF was based upon ICD-9 code documentation. The prevalence of AF in these three groups was compared by multivariate logistic regression.

Results

The prevalence of AF was highest among CRC patients (10%) followed by adenoma patients (7.2%) then the control group (5.4%, P for trend = 0.002). In the three groups of participants, older age (P<0.008) and heart failure (P<0.001) were significantly associated with higher risk of AF. After adjusting for these risk factors, CRC (OR: 1.4(95%CI):0.9–2.2, P = 0.2) and adenoma (OR: 1.1(95%CI):0.7–1.6, P = 0.7) were not significantly associated AF compared to control group.

Conclusions

AF is highly prevalent among CRC patients; 1 in 10 patients had AF in our study. The predictors of AF in CRC was similar to that in adenoma and other patients after adjustment for potential confounders suggesting that the increased AF risk in CRC is explained by higher prevalence of AF risk factors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号