首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
A mediator-free amperometric hydrogen peroxide biosensor was prepared by immobilizing horseradish peroxidase (HRP) enzyme on colloidal Au modified platinum (Pt) wire electrode, which was modified by poly 2,6-pyridinediamine (pPA). The modified process was characterized by electrochemical impedance spectroscopy (EIS), and the electrochemical characteristics of the biosensor were studied by cyclic voltammetry, linear sweep voltammetry and chronoamperometry. The biosensor displayed an excellent electrocatalytical response to reduction of H2O2 without the aid of an electron mediator, the linear range was 4.2 × 10−7–1.5 × 10−3 mol/L (r = 0.9977), with a detection limit of 1.4 × 10−7 mol/L. Moreover, the performance and factors influencing the resulted biosensor were studied in detail. The studied biosensor exhibited permselectivity, good stability and good fabrication reproducibility.  相似文献   

2.
A convenient and effective way for fabricating amperometric hydrogen peroxide (H2O2) biosensor was designed in this paper. First, the polyaniline (PANI) nanofibers membrane with good conductance and high surface area was electropolymerized on a gold electrode surface. Then, Pt nanoparticle (PtNP) was electrochemically deposited on the PANI nanofibers membrane. Finally, the hybrid film of gold nanoparticle, chitosan, and horseradish peroxidase (HRP) was cast onto the modified electrode to form a stable biofunctional film, which was also employed as a protective layer to PtNP. The proposed biosensor exhibited a rapid response to H2O2 with the linear range from 7.0 × 10−6 to 1.4 × 10−2 M and a detection limit of 2.8 × 10−6 M (S/N = 3). The sensitivity of 558 μA mM−1 cm−2 was obtained. The Michaelis–Menten constant, K\textM\textapp K_{\text{M}}^{\text{app}} value was 1.90 mM suggesting a high affinity. Moreover, it displayed a good reproducibility and long-term stability.  相似文献   

3.
A hydrogen peroxide (H2O2) sensor was developed by electrodepositing Prussian blue (PB) on a gold electrode modified with (3-mercaptopropyl)-trimethoxysilane (MPS) polymer. The characterization of the self-assembled electrode was investigated by cyclic voltammetry and electrochemical impedance spectroscopy. The results of electrochemical experiments showed that such constructed sensor had a favorable catalytic ability to reduce H2O2. The MPS film on the modified gold electrode greatly enhanced the pH-adaptive range of PB. Large surface-to-volume ratio property of double-layer 2d-network MPS-modified PB electrode enabled stable and highly sensitive performance of the non-enzymatic H2O2 sensor. The linear range of H2O2 determined is from 2.0 × 10−6 to 2.0 × 10−4 mol L−1 with a correlation coefficient of 0.9991 and a detection limit for H2O2 of 1.8 × 10−6 mol L−1. The influences of the potentially interfering substances on the determination of H2O2 were investigated. This modified electrode exhibits a good selectivity and high sensitivity with satisfactory results.  相似文献   

4.
In this research, the enhancement of electron-transfer activity of hemoglobin (Hb) in lauric acid film was investigated for the first time. This type of composite film was made on a glassy carbon electrode by a casting method. Cyclic voltammetric result of the modified electrode displays a well-defined redox peak, which was attributed to the direct electrochemical response of Hb. Our results illustrate that Hb exchange electrons directly with electrode and exhibits the characteristics of peroxidase. When we use this modified electrode as a biosensor, it gives excellent performance in the electrocatalytic reduction of hydrogen peroxide (H2O2). The parameters such as pH and applied potential of the biosensor influencing in H2O2 detection were optimized carefully. Through the optimal conditions, the proposed biosensor shows the linear range for H2O2 determination was from 1×10−5 to 1.25×10−4 mol L−1 with a detection limit of 1×10−7 mol L−1. The biosensor retained more than 90% of the initial response after 14 d.  相似文献   

5.
A novel third-generation biosensor for hydrogen peroxide (H2O2) has been constructed based on horseradish peroxidase (HRP) immobilized by the sol–gel (SG) technology on carbon nanotube (CNT)-modified electrode. CNT has good promotion effects on the direct electron transfer between HRP and the electrode surface and the SG network provides a biocompatible microenvironment for enzyme. The immobilized HRP retained its bioelectrocatalytic activity for the reduction of hydrogen peroxide and can respond to the change of concentration of H2O2 rapidly. The heterogeneous electron transfer rate constant was evaluated to be 2.8 ± 0.4 s−1. The amperometric response to H2O2 shows a linear relation in the range from 0.5 to 300 μmol l−1 and a detection limit of 0.1 μmol l−1 (S/N = 3). The K Mapp value of HRP immobilized on the electrode surface was found to be 1.35 mmol l−1. The biosensor exhibited high sensitivity, rapid response and excellent long-term stability.  相似文献   

6.
Direct electron transfer of hemoglobin modified with quantum dots (QDs) (CdS) has been performed at a normal graphite electrode. The response current is linearly dependent on the scan rate, indicating the direct electrochemistry of hemoglobin in that case is a surface-controlled electrode process. UV–vis spectra suggest that the conformation of hemoglobin modified with CdS is little different from that of hemoglobin alone, and the conformation changes reversibly in the pH range 3.0–10.0. The hemoglobin in a QD film can retain its bioactivity and the modified electrode can work as a hydrogen peroxide biosensor because of its peroxidase-like activity. This biosensor shows an excellent response to the reduction of H2O2 without the aid of an electron mediator. The catalytic current shows a linear dependence on the concentration of H2O2 in the range 5 × 10−7–3 × 10−4 M with a detection limit of 6 × 10−8 M. The response shows Michaelis–Menten behavior at higher H2O2 concentrations and the apparent Michaelis–Menten constant is estimated to be 112 μM.  相似文献   

7.
The report is on an electrochemical biosensor with remarkably improved sensitivity toward nitrite. In this strategy, positively charged gold nanoparticle (PCNA) is used in combination with multiwall carbon nanotubes (MWCNT) by electrostatic adsorption for fabricating PCNA/MWCNT films. Then hemoglobin (Hb) biocatalyst will easily be attached to the surface of the combination films aforementioned. After that, the Hb/PCNA films are immobilized onto the Hb/PCNA/MWCNT films through layer-by-layer assembly technique. The (Hb/PCNA)2/MWNT/GC electrode thus prepared exhibits enhanced electrocatalytic behavior to the reduction of nitrite at −0.10 V versus SCE in 0.05 M H2SO4 solution. On condition of the low detecting potential and low pH, interference caused by direct electrochemical oxidation or oxidizable substances can be prevented. Therefore, the modified electrode shows fast response time, very high sensitivity, good selectivity and stability. The current response of the sensor increases linearly with nitrite concentration from a range of 3.6 × 10−6 to 3.0 × 10−3 M with a detection limit(S /N = 3) of 9.6 × 10−7 M.  相似文献   

8.
A novel hydrogen peroxide biosensor was fabricated for the determination of H2O2. The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H2O2 in the linear range from 2.6 × 10 6 mol/L to 8.8 × 10 3 mol/L with a detection limit of 6.4 × 10 7 mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.  相似文献   

9.
Cytochrome c was immobilized covalently onto nickel oxide nanoparticles/carboxylated multiwalled carbon nanotubes/polyaniline composite (NiO-NPs/cMWCNT/PANI) electrodeposited on gold (Au) electrode. An amperometric H2O2 biosensor was constructed by connecting this modified Au electrode along Ag/AgCl as reference and Pt wire as counter electrode to the galvanostat. The modified Au electrode was characterized by cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), scanning electron microscopy (SEM) and Fourier transform infra-red spectroscopy (FTIR). Cyclic voltammetric (CV) studies of the electrode at different stages demonstrated that the modified Au electrode had enhanced electrochemical oxidation of H2O2, which offered a number of attractive features to develop an amperometric biosensor based on split of H2O2. There was a good linear relationship between the current (mA) and H2O2 concentration in the range 3–700 μM. The sensor had a detection limit of 0.2 μM (S/N = 3) with a high sensitivity of 3.3 mA μM?1 cm?2. The sensor gave accurate and satisfactory results, when employed for determination of H2O2 in different fruit juices.  相似文献   

10.
A convenient and effective strategy for fabrication of hydrogen peroxide biosensor based on sodium alginate (SA) and polyvinyl butyral (PVB) as matrices was reported in this paper. The horseradish peroxidase (HRP) and SA were electro-co-deposited onto the surface of gold electrode, and the HRP–SA/Au electrode was further coated with PVB. The interaction between HRP and SA was characterized by UV–vis absorption spectroscopy, and the fabricating process of biosensor was characterized by electrochemical impedance spectroscopy (EIS). The electrochemical characteristics of the biosensor were studied by cyclic voltammetry and chronoamperometry. Experimental conditions were investigated which influence the performance of the biosensor, such as pH, and applied potential. The biosensor showed a linear response to H2O2 over a concentration range from 7.0 × 10−6 to 4.1 × 10−3 M with a detection limit of 1.8 × 10−6 M based on a signal-to-noise ratio of 3 under optimum conditions. The value of HRP in the composite was evaluated to be 1.38 mM. The biosensor obtained from this study possesses high sensitivity, good reproducibility, and long-term stability.  相似文献   

11.
A sensitive and noble amperometric horseradish peroxidase (HRP) biosensor is fabricated via the deposition of gold nanoparticles (AuNPs) onto a three-dimensional (3D) porous carbonized chicken eggshell membrane (CESM). Due to the synergistic effects of the unique porous carbon architecture and well-distributed AuNPs, the enzyme-modified electrode shows an excellent electrochemical redox behavior. Compared with bare glass carbon electrode (GCE), the cathodic peak current of the enzymatic electrode increases 12.6 times at a formal potential of −100mV (vs. SCE) and charge-transfer resistance decreases 62.8%. Additionally, the AuNPs-CESM electrode exhibits a good biocompatibility, which effectively retains its bioactivity with a surface coverage of HRP 6.39×10−9 mol cm−2 (752 times higher than the theoretical monolayer coverage of HRP). Furthermore, the HRP-AuNPs-CESM-GCE electrode, as a biosensor for H2O2 detection, has a good accuracy and high sensitivity with the linear range of 0.01–2.7 mM H2O2 and the detection limit of 3μM H2O2 (S/N = 3).  相似文献   

12.
A novel H2O2 biosensor is described which is based on immobilization of horseradish peroxidase (HRP) on DNA/electrodeposited, ZrO2/modified, gold electrode. The DNA is attached via its 5′ end to ZrO2 and this provides a microenvironment for the immobilization of various biomolecules and promotes electron transfer between HRP and the electrode surface. Under optimized conditions, the biosensor reduced H2O2 linearly between 3.5 μM and 10 mM with a detection limit of 0.8 μM at a signal-to-noise ratio of 3. In addition, the developed biosensor shows an acceptable stability and repeatability. Importantly, the analytical methodology could be further developed for the immobilization of other proteins and biocompounds.  相似文献   

13.
Summary The effect of low concentrations of hydrogen peroxide (H2O2) (5 × 10−7−9.5 × 10−7 M) on cell growth and antibody production was investigated with murine hybridoma cells (Mark 3 and anti-hPL) in culture. Cell growth, measured by flow cytometry with morphological parameters, was significantly stimulated by H2O2 (8 × 10−7 M) but H2O2 concentration of 7 × 10−6 M and above increased cell death. H2O2 stimulation of antibody production was nonsignificant. The metabolism of cells treated with 8 × 10−7 or 1 × 10−5 M H2O2 was similar to that of the control in terms of glucose and glutamine consumption, lactate and ammonia production, and amino acid concentrations in the medium. The concentrations of lactate dehydrogenase, a marker of cell death, in test and control cells were similar. However, concentrations of intracellular free radicals measured by flow cytometry with dihydrorhodamine 123 (DHR 123) and dichlorofluorescein diacetate (DCFH-DA) as fluorochromes were different. The reactive oxygen species content of cells in 8 × 10−7 M H2O2 was similar to that of the controls, but there was a sudden, marked production of superoxide anions (detected with DHR 123) and H2O2 or peroxides (detected with DCFH-DA) by cells incubated with 1 × 10−5 M H2O2 which increased with increasing H2O2 until cell death.  相似文献   

14.
Accurate and highly sensitive evaluation of the sirtuin 1 (SirT1) level is becoming increasingly important for understanding the contribution of SirT1 in metabolism pathways. Here, a novel electrochemical immunoassay of SirT1 based on crosslinked hyperbranched azo-polymer decorated with gold colloids (Au–HAP) as sensing platform and titanium dioxide (TiO2)–Au nanocomposites to immobilize secondary antibody–horseradish peroxidase (Ab2–HRP) as electrochemical labels has been designed. Greatly enhanced sensitivity was achieved by exploiting the excellent conductivity of Au nanoparticle, the amplification effect of Au–HAP and TiO2–Au, and the favorable catalytic ability of HRP. The nanocomposites of Au–HAP and TiO2–Au could attach numerous capture antibodies on the surface for significant immune recognition efficiency. Meanwhile, the TiO2–Au-labeled Ab2–HRP using an HRP–thionine–H2O2 (hydrogen peroxide) detection system could further induce signal readout. Under optimal conditions, the signal intensity was linearly related to the concentration of SirT1 in the range of 1–500 ng ml−1, and the limit of detection was 0.28 ng ml−1. The developed biosensor exhibits attractive performance for the analysis of SirT1, with rapid response, high sensitivity, and high accuracy, and could become a promising technique for protein detection.  相似文献   

15.
Kinetics of 1-hydroxypyrene (1-HP) oxidation catalyzed with recombinant Coprinus cinereus (rCiP) and horseradish (HRP) peroxidases was investigated with a special emphasis for developing a nanomolar hydrogen peroxide (H2O2) detection system. At pH 8.0 the bimolecular constants of 1-HP oxidation with the ferryl compounds of rCiP and HRP were equal to (1.0 ± 0.3) × 108 M−1 s−1 and (0.6 ± 0.2) × 108 M−1 s−1, respectively. High bimolecular constants and fluorescence quantum yield of 1-HP (0.66) permitted detection as low as 21 nM of H2O2. To optimize the detection system 1-HP oxidation was modeled at steady-state conditions in the range pH 5.0 to pH 8.0. The 1-HP based detection system was compared with the Amplex Red system. The peroxidase-catalyzed 1-HP oxidation system was used for determination of ozone in the air.  相似文献   

16.
A direct electrochemical immunoassay system based on the immobilization of α-1-fetoprotein antibody (anti-AFP), as a model system, on the surface of core-shell Fe2O3/Au magnetic nanoparticles (MNP) has been demonstrated. To fabricate such an assay system, anti-AFP was initially covalently immobilized on to the surface of core-shell Fe2O3/Au MNP. Anti-AFP-modified MNP (bio-nanoparticles) were then attached to the surface of carbon paste electrode with the aid of a permanent magnet. The performance and factors influencing the performance of the resulting immunosensor were studied. α-1-Fetoprotein antigen was directly determined by the change in current or potential before and after the antigen–antibody reaction versus saturated calomel electrode. The electrochemical immunoassay system reached 95% of steady-state potential within 2 min and had a sensitivity of 25.8 mV. The linear range for AFP determination was from 1 to 80 ng AFP ml−1 with a detection limit of 0.5 ng AFP ml−1. Moreover, the direct electrochemical immunoassay system, based on a functional MNP, can be developed further for DNA sensor and enzyme biosensor. Revisions requested 2 November 2005; Revisions received 17 January 2006  相似文献   

17.
A new amperometric biosensor for the detection of sugars was prepared. A glassy carbon electrode was modified with Prussian blue (PB) nanoparticles protected by chitosan (CS) and poly(diallyldimethylammonium chloride) (PDDA), and then gold nanoparticles were assembled onto the electrode followed by the assembly of 4-mercaptophenylboronic acid (MPBA) onto the surface of gold nanoparticles through a sulfur–Au bond to fabricate a self-assembled biosensor. The PB nanoparticles protected by CS and PDDA were characterized using transmission electron microscopy and UV–vis absorption spectroscopy. The characterization of the self-assembled electrode was investigated by cyclic voltammetry and electrochemical impedance spectroscopy. The pK a values of the MPBA monolayer before and after combining with sugars were determined. The fabricated electrode exhibited excellent performances for determining d(+)-glucose, d(+)-mannose, and d(−)-fructose on the basis of the change in i p of the Fe(CN)63−/4− ion in the presence of sugars.  相似文献   

18.
A novel amperometric hydrogen peroxide biosensor based on the immobilization of hemoglobin on the 2,6-pyridinedicarboxylic acid (PDC) polymer, thionine and nano-Au was successfully fabricated. In this strategy, PDC polymer acted as the matrices to covalently immobilize the thionine, and then hemoglobin was successfully adsorbed on the nano-Au which was electro-deposited on to thionine modified electrode surface. The preparation process of modified electrode was characterized with electrochemical impedance spectroscopy and atomic force microscope. The analytical performance of proposed biosensor toward H2O2 was investigated by cyclic voltammetry and chronoamperometry. The resulted biosensor exhibited fast amperometric response (within 6 s) to H2O2, and linear range was from 9.1 μM to 5.0 mM with the detection limit of 2.6 μM (S/N = 3). The apparent Michaelis–Menten constant (K Mapp) was evaluated to be 3.2 mM. Furthermore, the resulted biosensor showed good stability and reproducibility.  相似文献   

19.
Ming L  Xi X  Liu J 《Biotechnology letters》2006,28(17):1341-1345
A platinized carbon paste prepared via electrodeposition had a preferential electrocatalytic action toward H2O2. Therefore, we have developed a new amperometric glucose biosensor based on the immobilization of glucose oxidase on to the electrochemically platinized carbon paste. The proposed biosensor is free of potential interferences due to its cathodic detection of glucose at the potential of 0.0 V (vs. Ag/AgCl). It also shows acceptable analytical performance in terms of linearity (6 × 10−5 to 1.2 × 10−2 M, r = 0.998), detection limit (2 × 10−5 M), response time (20–30 s), reproducibility (RSD = 4.4%), and storage life (t 0.80 = 45 days). All these advantages of the biosensor raise potential possibilities for its medical or other biotechnical applications.  相似文献   

20.
A simple and sensitive electrochemical DNA biosensor based on in situ DNA amplification with nanosilver as label and horseradish peroxide (HRP) as enhancer has been designed. The thiolated oligomer single-stranded DNA (ssDNA) was initially directly immobilized on a gold electrode, and quartz crystal microbalance (QCM) gave the specific amount of ssDNA adsorption of 6.3 ± 0.1 ng/cm2. With a competitive format, hybridization reaction was carried out via immersing the DNA biosensor into a stirred hybridization solution containing different concentrations of the complementary ssDNA and constant concentration of nanosilver-labeled ssDNA, and then further binding with HRP. The adsorbed HRP amount on the probe surface decreased with the increment of the target ssDNA in the sample. The hybridization events were monitored by using differential pulse voltammetry (DPV) with the adsorbed HRP toward the reduction of H2O2. The reduction current from the enzyme-generated product was related to the number of target ssDNA molecules in the sample. A detection of 15 pmol/L for target ssDNA was obtained with the electrochemical DNA biosensor. Additionally, the developed approach can effectively discriminate complementary from non-complementary DNA sequence, suggesting that the similar enzyme-labeled DNA assay method hold great promises for sensitive electrochemical biosensor applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号