1.
BACKGROUND: The DUET Study is a multicenter prospective efficacy and safety evaluation of the ACS MULTI-LINK DUET coronary stainless steel balloon-expandable stent. AIMS: The primary objective was to determine the one-month incidence of MACE (major adverse cardiac events). The secondary objectives were the acute success rate, the restenosis and reocclusion rates (assessed by quantitative coronary angiography (QCA)) at six months and the occurrence of MACE in hospital and at six months. METHODS: Two hundred and ten patients were enrolled between February and June 1998 in 18 European centers. Successful stent placement was achieved in 209 patients. All patients were treated with ticlopidine 500 mg/day for one month and with aspirin >/=100 mg/day. To allow the investigators to gain familiarity with the stent system, the first one to three patients per center formed a separate lead-in population leaving an intention-to-treat population of 157 patients. The majority of the intention-to-treat population were male (79%); 28% had unstable angina, 69% had stable angina, 44% had had a previous myocardial infarction, 15% had had a previous percutaneous transluminal coronary angioplasty, and 3% had a history of stroke. The target vessel was 38.5% left anterior descending artery, 20.5% left circumflex artery and 41.0% right coronary artery. RESULTS: All but one of the intention-to-treat patients were effectively stented (17 required multiple stents). Six-month angiographic follow-up was available in 90% of the intention-to-treat population. Minimal lumen diameter (MLD) postprocedure was 2.61 +/- 0.33 mm, with a residual diameter stenosis of 16%. Six-month follow-up data showed an MLD of 1.87 +/- 0.56 mm with a residual diameter stenosis of 36%. The binary restenosis rate (>/=50% residual stenosis) was 15.6%. Up to one month following the procedure 94.9% of the population was MACE-free, with two subacute occlusions. At six months all patients were alive, of whom 82.8% were MACE-free, and 73% were free of anginal complaints. CONCLUSION: The results observed in the current DUET registry are comparable to data of other balloon-expandable-stent trials, with a low incidence of clinical events at follow-up.  相似文献   

2.
AIMS: The BiodivYsio trade mark stent (Biocompatibles Ltd, Farnham, UK) is coated with a phosphorylcholine (PC)-containing copolymer to confer biocompatibility. The SOPHOS (Study Of PHosphorylcholine coating On Stents) study was designed to assess the safety and efficacy of this novel coronary stent and by indirect comparison to indicate equivalence with other formal stent studies. METHODS AND RESULTS: Patients with angina and a single short (#x2A7F;12 mm) de novo lesion in a native coronary artery of >/=2.75 mm diameter were included. A total of 425 patients were allocated in 24 centers. Clinical data were collected at one-, six- and nine-month follow-up. Angiography was performed before and after the stent implantation. In addition, in the first 200 patients (SOPHOS A) angiography was routinely performed at six months. The following 225 patients (SOPHOS B) were merely followed up clinically. The primary end-point of the study, the six-month MACE-rate (MACE = Major Adverse Cardiac Events) was 13.4% (two cardiac death; five Q-wave/nine non-Q-wave myocardial infarctions (MI); nine CABG and 32 target lesion revascularization (TLR), which is similar to the calculated 15% MACE-rate in comparable reference studies. Secondary end-points included among others restenosis at six months in the SOPHOS A population. The target vessel diameter was 2.98 +/- 0.48 mm. Minimal lumen diameter pre/post procedure and at follow-up was 1.00 +/- 0.32, 2.69 +/- 0.37, 1.91 +/- 0.71 mm, respectively. The binary restenosis rate (>/=50% diameter stenosis at follow-up) was 17.7%. CONCLUSION: The coronary BiodivYsio stent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with stable or unstable angina pectoris. Clinical and angiographic results are in the statistical range of equivalence with comparable studies with other current stents.  相似文献   

3.
BACKGROUND: Although safety and efficacy of the NIR trade mark stent have been reported, the long-term angiographic and clinical outcomes have yet to be investigated. The FINESS-II study (First International NIR Endovascular Stent Study) was designed to assess the procedural safety of single 9 and 16 mm NIR stent implantation, the six-month restenosis rate and finally the six- and 12-month clinical outcome of patients treated with this novel coronary stent. METHODS: Patients with angina and a single de novo lesion in a native coronary artery of >3 and <5 mm diameter were included in this multicentre, prospective, observational trial. Clinical follow-up was obtained at one, six and 12 months. Angiography was performed before and after the stent implantation and at six months. The primary endpoint included major adverse cardiac events (death, myocardial infarction and target lesion revascularization) within 30 days after the procedure. Major bleeding complications and subacute stent thrombosis within the first 30 days were also reported as specific endpoints. Secondary endpoints were major cardiac-event-free survival at six- and 12-month follow-up and angiographic restenosis at six months. RESULTS: A total of 156 patients (81% male, mean age 60 +/- 10 years), with stable (54%), unstable (40%) angina pectoris or silent ischemia (6%) were enrolled. The target vessel diameter was 2.94 +/- 0.54 mm. The minimal lumen diameter pre, post and at follow-up was 1.04 +/- 0.32 mm, 2.64 +/- 0.42 mm and 1.88 +/- 0.63 mm, respectively. Restenosis rate according to the >50% diameter stenosis criterion at six month follow-up was 19% (26/136). At 12 months, the event-free survival rate was 83% (two deaths, one Q-wave and three non-Q-wave myocardial infarctions, four bypass surgery and 17 target lesion revascularizations), while 87% of the patients were free of angina pectoris. CONCLUSION: the outcome of the FINESS-II trial is comparable to those observed in previous stent trials (Benestent II), indicating that the coronary NIR stent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with (un)stable angina pectoris.  相似文献   

4.
BACKGROUND: Although safety and efficacy of the beStent (Medtronic Inc., Santa Rosa, CA, USA) have been described, the long-term angiographic and clinical outcomes have yet to be investigated. The ROSE (Registry for Optimal beStent Evaluation) trial was designed to assess the procedural safety of single 15 mm beStent implantation, and the six-month angiographic and 12-month clinical outcomes of patients treated with this novel coronary stent. METHODS: Patients with angina and a single de novo lesion in a native coronary artery of >/=2.75 mm diameter were included in this multicenter, prospective, observational trial. Clinical follow-up was obtained at one, six and 12 months. Angiography was performed before and after the stent implantation and at six months. The primary end-point included major adverse cardiac events (death, myocardial infarction and target lesion revascularization), major bleeding complications, and thrombotic occlusions at one-month follow-up. Secondary end-points were major cardiac-event-free survival at six- and 12-month follow-up and angiographic restenosis at six months. A total of 120 patients (80% male, mean age 58.6 +/- 10.6 years) with stable (48%) or unstable (44%) angina pectoris were allocated. The target vessel reference diameter pre-procedure was 2.85 +/- 0.52 mm. RESULTS: Minimal lumen diameter pre/post and at follow-up was 0.97 +/- 0.28 mm, 2.53 +/- 0.40 mm and 1.86 +/- 0.63 mm, respectively. Restenosis rate according to the >50% diameter stenosis criterion at six-month follow-up was 21.5%. At 12 months, the event-free survival rate was 75% (no deaths, two Q-wave and seven non-Q-wave infarctions, five bypass surgery interventions and 16 target lesion revascularizations), whilst 87% of the patients were free of angina pectoris. CONCLUSION: Despite the relatively high percentage of small vessels, the outcome of the ROSE trial is comparable to those observed in previous stent trials, indicating that the coronary beStent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with (un)stable angina pectoris.  相似文献   

5.
BACKGROUND: Intravascular stents are increasingly being used to treat subclavian artery obstructive disease. This study aimed to assess the immediate and mid-term clinical outcome of subclavian artery stenting. METHODS AND RESULTS: Total occlusion of the subclavian artery was seen in 7 (28%) out of the 25 consecutive patients treated for subclavican artery stenosis. Mean lesion length was 14 +/- 4.3 mm. The mean preprocedure diameter stenosis was reduced from 83.2 +/- 14.9% to 9.6 +/- 5.4% postprocedure. Procedural success was achieved in all patients. Clinical follow-up was obtained in all patients. The initial success was maintained at follow-up (mean = 12 +/- 4 months) in 24 (96%) patients. Recurrence of symptoms occurred in 1 (4%) patient who had an angiographically documented restenosis four months after the procedure. It was successfully redilated. CONCLUSION: Stenting for subclavian artery obstructive disease is safe, technically feasible and has favorable clinical outcomes. It may be considered as the therapy of choice for subclavian artery obstructive disease.  相似文献   

6.
BACKGROUND: Recent publications have shown an increased risk of coronary artery disease and myocardial infarction in patients with alteration of the hemochromatosis-related gene (HFE gene). The HFE gene mutation is associated with elevated iron uptake and serum iron overloading. Iron plays an important role in promoting the oxidation of LDL cholesterol. The iron deposition in the endothelium and in the media is closely associated with the progression of atherosclerosis. However, it is unclear whether the mutation of the HFE gene also influences the rate of restenosis after coronary stent implantation. METHODS: In a retrospective analysis, 137 patients (pts.) who underwent elective coronary stent implantation were angiographically reevaluated after six months. All patients were part of the OPTICUS-study population which investigated optimized stent implantation guided by intravascular ultrasound. Computerized quantitative analysis was performed in all procedures in a double-blinded fashion. At six-month follow-up, DNA fragments containing the substitution of tyrosine for cytosine at codon 282 were amplified by PCR. The results were analyzed by polyacrylamide gel electrophoresis. Statistical analysis was performed by multivariate linear regression. RESULTS: According to the HFE gene polymorphism we formed two subgroups: 129 pts. (94%) did not show changes in HFE gene (NH), 8 pts. (6%) were heterozygous for HFE Cys282Tyr (H). The groups did not differ in age, gender, extent of coronary artery disease, initial degree and length of stenosis and all patients underwent re-angiography. At six-month follow-up the average luminal narrowing in the stented vessel was 36.2 +/- 20.3% in the NH group compared with 27.8 +/- 20.0% in the H group which was statistically not significant (n. s.). The minimal luminal diameter was 1.9 +/- 0.71 mm in the NH group and 2.2 +/- 0.66 mm in the H group respectively (n. s.). 33 pts (26%) in the NH group versus 2 pts (25%) in the H group had >/= 50% diameter narrowing at follow-up (n. s.). The odds ratio of stent restenosis in H patients was 0.932. CONCLUSIONS: The authors did not find any association between restenosis rate and HFE gene alteration and therefore, we conclude that the polymorphism of the HFE gene is not a risk factor for restenosis after coronary stent implantation.  相似文献   

7.

Aims

To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs).

Methods and Results

A randomised controlled trial was performed in four hospitals in three European countries between December 2011 and December 2013. Patients with de novo lesions (>50% stenosis) in an SVG with a diameter between 2.5–6?mm were included. Primary endpoint was late lumen loss at 6 months. Secondary endpoints included procedural success and the occurrence of major adverse cardiac events (MACE) at 12 months. A total of 57 patients were randomised to STENTYS self-apposing BMS (n = 27) or PES (n = 30). Procedural success was obtained in 89.5%. No significant differences in late lumen loss were found between BMS and PES at 6 months (0.53?mm vs 0.47; p = 0.86). MACE rates at 12 months were comparable in both groups (BMS 22.2% vs. PES 26.7%; p = 0.70).

Conclusions

Treatment of SVGs with STENTYS self-expandable stents is safe and effective. No significant differences were found in late lumen loss and MACE between BMS and PES.
  相似文献   

8.
The Tsunami is a new, balloon-expandable, stainless steel, tubular coronary stent whose design is based on a number of radial, diamond-shaped cells joined by double connectors. The aim of this two-centre, prospective, nonrandomized study was to examine the procedural, in-hospital, and long-term clinical and angiographic outcomes of patients undergoing angioplasty with the Tsunami stent. Sixty-one consecutive unselected patients were treated by means of the implantation of 74 Tsunami stents in 72 coronary lesions. Most of the patients (64%) had unstable angina or acute myocardial infarction. The baseline lesion morphology was complex in 76% of cases, and the mean lesion length was 14 +/- 6 mm. The procedural success rate was 98%. Mean percentage diameter of the stenosis decreased after the intervention from 79 +/- 12% to 10 +/- 6%. The in-hospital major adverse cardiac event rate was 3.3%. During the six-month follow-up, there was one cardiac death and nine subjects (14.5%) underwent target vessel revascularization. The six-month event-free survival rate was 80%. The angiographic restenosis rate was 17%: a focal or limited pattern (class I or II) was found in 43% of cases, whereas the remaining 57% had a proliferative morphology (class III or IV). In conclusion, this study indicates the good clinical and angiographic performance of the Tsunami coronary stent system in consecutive unselected patients.  相似文献   

9.
Early deterioration of minimal luminal diameter immediately after PTCA, has been associated with an increase of late restenosis. Lesions with no early loss after PTCA have a low restenosis rate. Coronary stents reduce restenosis in lesions exhibiting early wall recoil. The purpose of the OCBAS study was to compare two strategies during coronary interventions; provision vs. elective stenting. 116 patients with good PTCA results were randomized to stent (n = 57) or to optimal PTCA (n = 59). After randomization in PTCA group, 13.5% of the patients crossed over to stent due to early loss (provisional stenting). Baseline demographic and angiographic characteristics were similar in both groups of patients. At 7.6 months, 96.6% of the entire population had a follow-up angiographic study; 98.2% in the stent and 94.9% in the PTCA group. Immediate and follow-up angiographic data showed that acute gain was significantly higher in the stent than in the PTCA group (1.95 vs. 1.5 mm; P < 0.03). However, late loss was significantly higher in the stent than the PTCA groups (0.63 +/- 0.59 vs. 0.26 +/- 0.44, respectively; P = 0.01). Hence, net gain with both techniques was similar (1.32 +/- 0.3 vs. 1.24 +/- 0.29 mm for the stent and PTCA groups respectively; P = NS). Angiographic restenosis rate at follow-up (19.2% in stent vs. 16.4% in PTCA; P = NS) and TVR (17.5 in stent vs. 13.5% in PTCA; P = NS) were also similar. Furthermore, event-free survival was 80.8% in the stent versus 83.1% in the PTCA group (P = NS). Overall costs (hospital and follow-up) were US$591,740 in the stent versus US$398,480 in the PTCA group (P < 0.02). The strategy of the PTCA with delay angiogram and provisional stent if early loss occurs, had similar restenosis rate and TVR than universal use of bare stents.  相似文献   

10.
BACKGROUND: Over the past 10 years stents have been used more frequently for the treatment of de novo coronary artery stenosis. Initally these devices were used primarily in coronary arteries with diameters ranging from 3.0 to 4.0 mm. Traditionally, coronary arteries less than 3.0 mm in diameter were treated with only balloon angioplasty, due to the unavailablity of flexible, low profile, small diameter stents. In the past three years, many stents have been designed to be implanted in small coronary arteries. OBJECTIVE: The objective of this study was to evaluate the safety and feasiblity of the R Stent in patients with coronary lesions located in coronary arteries with a reference diameter 2.5-3.0 mm. METHODS AND RESULTS: Between November 1998 and September 1999, 32 patients with stable (37%) and unstable (63%) angina treated with the R Stent were included in this study. The treated lesions were in the right coronary artery (RCA) (n = 13), left cirumflex coronary artery (LCX) (n = 10), and left anterior descending coronary artery (LAD) (n = 9). Of these lesions thirteen were anatomically complex. Stent deployment was successful in 97% with one crossing failure in a patient with a vessel tortuosity of greater than 75 degrees of the circumflex artery. No post-procedual major adverse cardiac and cerebrovascular event (MACCE) occurred within 30 days of stent implantation. After the procedure, patients were scheduled for a two-week telephone follow-up and a one-month clinical evaluation. At 30 days, only one patient (3%) experienced the recurrence of angina Canadian cardiovascular society classification ((CCS) Class 2). All other patients were event and angina free. CONCLUSION: This first clinical experience in patients with small vessel disease shows that the use of the R stent is safe and feasible with low rates of acute stent thrombosis.  相似文献   

11.
Preliminary experience with primary stenting in myocardial infarction has suggested a greater benefit in clinical outcome than has been obtained with direct balloon angioplasty. However, subacute thrombosis (SAT) remains a limitation for this new mode of therapy. In the BENESTENT II Pilot and main trials, the incidence of SAT with the heparin-coated Palmaz-Schatz stent was only 0.15%. Therefore, as a preamble to a large randomized trial, the feasibility and safety of the use of the Heparin-Coated Palmaz-Schatz trade mark Stent in Acute Myocardial Infarction (AMI) was tested in 101 patients enrolled between April and September 1996 in 18 clinical centres. In 101 stent-eligible AMI patients, as dictated by protocol, a heparin-coated stent was implanted. The primary objectives were to determine the in-hospital incidence of major adverse cardiac events (MACE: death, MI, target lesion revascularization) and bleeding complications, while the secondary objectives were the procedural success rate and the MACE, the restenosis and reocclusion rates at 6.5 months. Stent implantation (n 3 129 stents) was successful in 97 patients of the 101 who were included in this trial. During their hospital stay, two patients died and no patient experienced re-infarction, ischaemia prompting re-PTCA or CABG. Four patients suffered a bleeding complication, three major and one minor, of whom three required surgical repair. At 210 days follow-up, 81% of the patients were event free. At 6.5 months restenosis was documented in 18% of the 88 patients who underwent follow-up angiography, including three total occlusions. The results, both with respect to QCA and the occurrence of MACE, compare favourably with studies using elective stenting in both stable and unstable angina patients. As a result of this pilot study, a large randomized trial comparing direct balloon angioplasty with direct stenting in 900 patients with AMI was initiated in December 1996.  相似文献   

12.
BACKGROUND: Coronary artery stenting is particularly useful during percutaneous coronary intervention for long lesions previously associated with a low procedural success rate and a high complication rate of dissection and occlusion. Current treatment options include implantation of a single long stent, multiple contiguous stents, or 'spot' stenting. However, multiple stent implantation may result in sections of overlapping stent or gaps of unstented segments and is an independent predictor of restenosis. The early and intermediate clinical outcome of single and multiple long stent (>/= 30 mm) implantation is not established. METHODS AND RESULTS: The authors retrospectively identified 123 consecutive patients who had undergone stenting using one or more long coronary stents. Baseline clinical data, procedural outcomes and completed clinical follow-up to 52 weeks were obtained by case-note review. The majority (69%) required intervention for stable coronary disease. Seventy-seven per cent of lesions were either type B2 or C and only 2% were in saphenous vein grafts. The procedural success rate was 94%. A total of 15 major events occurred in 13 patients (11%). Ten acute events occurred and five events were during the follow-up period from 30 days to 52 weeks. Two patients died, one from uncontrolled bleeding secondary to the use of antithrombotic agents and one at four weeks due to sudden death. One patient had a postprocedural infarct. Two patients required in-hospital repeat revascularization for acute vessel closure and eight required revascularization during follow-up (three cases of occlusion/thrombosis and five cases of restenosis). CONCLUSIONS: The use of long coronary stents (>/= 30 mm) for the treatment of long diffuse native vessel disease, saphenous vein graft disease and long coronary dissections is associated with a reasonable procedural success rate and acceptable early and intermediate-term clinical outcomes.  相似文献   

13.
BACKGROUND: The mechanism for the disappointing late outcome following stenting of bifurcation lesions is unclear. This prospective observational study aims to evaluate culotte stent deployment and dimensions with intravascular ultrasound (IVUS). PATIENTS AND METHODS: Patients with bifurcation stenoses were treated using two stents in a culotte configuration. After optimizing the angiographic appearance of both stents, IVUS was used to evaluate both limbs of the culotte. The main outcome measures were cross-sectional area (CSA) and minimal lumen diameter (MLD) assessed by IVUS. RESULTS: Within the culotte stent, the final mean CSA in the main limb was 6.1 mm(2) (97% of reference) and in the side-limb was 5.9 mm(2) (97% of reference). However, in each case, the minimum CSA and IVUS MLD of both limbs was at the bifurcation point. For all patients, the final mean CSA at the bifurcation point of the main limb was 4.3 mm(2) (70% of main stent) and of the side-limb was 4.4 mm(2) (75% of side stent). The IVUS MLD at the bifurcation point of the main limb was 2.1 mm (78% of main stent) and of the side-limb was 2.1 mm (84% of the side stent). Importantly, this significant residual stenosis was not detectable with quantitative coronary angiography. CONCLUSIONS: IVUS evaluation of culotte stents is feasible. The minimum IVUS CSA and MLD of both limbs of the culotte stent is at the bifurcation point. Despite an optimal angiographic appearance a significant residual stenosis was noted with IVUS at each bifurcation point.  相似文献   

14.
Objectives. Stenting for native and recurrent coarctation (COA) in adults has become an important therapeutic strategy. In this prospective observational study we evaluated the intermediate-term outcome of stent implantation for either native or recurrent (re)COA in adults. Methods. All adults who underwent stent implantation in our institution between January 2003 and December 2008 were included. Diagnosis of (re)COA was based upon a combination of clinical signs, noninvasive imaging or invasive gradient measurements. NuMED stents were implanted under general anaesthesia. Results. Twenty-four patients (50% male) underwent stent implantation for native (n=6) or reCOA (n=18) at a median age of 36 (18 to 60) years. There was significant improvement in pre- versus post-stent invasive systolic gradient (19 vs. 0 mmHg, p<0.001) and COA diameter (10 vs. 16 mm, p<0.001). Acute complications (12.5%) included death due to aortic rupture despite immediate successful coverage with a covered stent (n=1) and groin haematoma (n=2). During a median follow-up period of 33 (8 to 77) months (n=22), late complications occurred in three patients (13.6%): stent migration to the ascending aorta (n=1), pseudoaneurysm at the site of the initial stent (n=1), and occluded external iliac artery (n=1). Stent implantation did not reduce the need for antihypertensive medication or blood pressure at last follow-up. Conclusion. COA stenting results in a significant gradient decrease and increase in vessel diameter. However, serious complications do occur and hypertension remains in the majority of patients. (Neth Heart J 2010;18:430-6.)  相似文献   

15.
Granulocyte-colony-stimulating-factor (G-CSF) induces mobilization of progenitor cells but may also exert pro-inflammatory and pro-thrombotic effects. Treatment with recombinant G-CSF after acute myocardial infarction is currently under examination and has been associated with in-stent restenosis. However, it is not known whether plasma levels of endogenous G-CSF are also associated with an increased cardiovascular risk. Therefore we included 280 patients with angiographically proven stable coronary artery disease. G-CSF was measured by specific ELISA and patients were followed for a median of 30 months for the occurrence of major adverse cardiovascular events (MACE: death, myocardial infarction, re-hospitalization). Those with cardiac events during follow-up showed significant higher G-CSF levels (32.3 pg/mL IQR 21.4–40.5 pg/mL vs. 24.6 pg/mL IQR 16.4–34.9 pg/mL; p<0.05) at baseline. Patients with G-CSF plasma levels above the median had a 2-fold increased risk for MACE (p<0.05). This was independent from established cardiovascular risk factors. In addition, G-CSF above the median was a predictor of clinical in-stent restenosis after implantation of bare-metal stents (6.6% vs. 19.4%; p<0.05) but not of drug-eluting stents (7.7% vs. 7.6%; p = 0.98). This data suggests that endogenous plasma levels of G-CSF predict cardiovascular events independently from established cardiac risk factors and are associated with increased in-stent restenosis rates after implantation of bare metal stents.  相似文献   

16.
Stress-induced release of IL-1alpha and fibroblast growth factor-1 is dependent on intracellular copper and is a major driver of neointimal hyperplasia. Therefore, we assessed the effect of tetrathiomolybdate (TTM), a clinically proven copper chelator, on in-stent restenosis. Nine pigs were treated with TTM (5 mg/kg po) twice daily for 2 wk before stent implantation and for 4 wk thereafter, and nine pigs served as controls. In-stent restenosis was assessed by quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), and histomorphometry. Serum ceruloplasmin activity was used as a surrogate marker of copper bioavailability. In TTM-treated animals, ceruloplasmin dropped 70 +/- 10% below baseline levels. Baseline characteristics were comparable in TTM-treated and control animals. At 4-wk follow-up, all parameters relevant to in-stent restenosis were significantly reduced in TTM-treated animals: minimal lumen diameter by QCA was 2.03 +/- 0.57 and 1.47 +/- 0.45 mm in TTM-treated and control animals, respectively (P < 0.05), percent stenosis diameter was 39% less in TTM-treated animals (27.1 +/- 16.6% vs. 44.5 +/- 16.1%, P < 0.05), minimal lumen area by IVUS was 60% larger in TTM-treated animals (4.27 +/- 1.56 vs. 2.67 +/- 1.19 mm(2), P < 0.05), and neointimal volume by histomorphometry was 37% less in TTM-treated animals (34.9 +/- 11.5 vs. 55.2 +/- 19.6 mm(3), P < 0.05). We conclude that systemic copper chelation with a clinically approved chelator significantly inhibits in-stent restenosis.  相似文献   

17.
目的:探讨ST段抬高急性心肌梗死(ST-elevation myocardial infarction,STEMI)患者靶血管长病变(病变>25 mm)急诊经皮冠状动脉介入(percutaneous coronary intervention,PCI)治疗的临床疗效及安全性。方法:回顾性收集2009年1月-2010年6月因STEMI就诊于沈阳军区总医院并急诊行PCI处理的患者442例,以靶病变长度分为两组,即≤25 mm为短病变组(n=235)和>25mm为长病变组(n=207),均急诊行PCI治疗,分析和比较两组患者术前的基线资料、术中资料及并发症的发生情况、辅助措施(临时起搏、IABP、血栓抽吸装置)应用情况,术后30天、2年电话或临床随访,记录主要不良心血管事件(major adverse cardiac events,MACE)的发生情况。结果:与短病变组比较,长病变组吸烟者更多(81.6%vs 62.6%,P=0.000);以三支病变偏多(34.8%vs 24.7%,P=0.037);多枚支架使用率更高(1.47±0.63 vs 1.04±0.28,P=0.000),平均支架总长度显著增加(29.80±7.02 mm vs 22.95±5.58mm,P=0.000),手术成功率、术中并发症及辅助措施应用情况比较差异无统计学意义(P>0.05),30天及2年随访MACE的发生率比较差异无统计学意义(P>0.05)。结论:与急诊PCI治疗的STEMI短病变患者对比,长病变患者虽然病变复杂,多枚支架使用率高,平均支架总长度增加,但术中并发症、30天、2年内MACE与短病变患者相当,提示在以药物洗脱支架为主的介入治疗时代,急诊PCI处理STEMI靶血管长病变具有良好的疗效及安全性。  相似文献   

18.
The loss of the corneal endothelial cells, especially in a first postoperative year, has been observed in patients who underwent penetrating keratoplasty (PK). The implantation of new generation of "iris claw" phakic IOL (Verisyse) in refractive cases has been shown to cause clinicaly insignificant endothelial cell loss. In our prospective case series we investigated the endothelial cell loss and clinical outcome in patients that either underwent PK and implantation of PCIOL or PK and implantation of Verisyse IOL. In the first group of 9 patients scheduled for PK, implantation of Verisyse was performed due to the absence of the posterior capsule support. 2 of these patients had angle supported ACIOL, 4 patients were aphakic and 3 had posttraumatic cataract with ruptured posterior capsule. The second group of 12 patients had standard "triple" procedure (PK + ECCE + PCIOL). BCVA of both groups of patients prior the operation was hand movement in 12 patients, light perception in 7 patients and 0.05 in 3 patients. The preoperative endothelial cell count of the donor grafts obtained from the eye bank was 2800 cells/mm2 on average. The follow up was 6-10 months. Six months after the operation all "Verysise" patients maintained transparent graft. Postoperative visual acuity improvement was recorded in 18 out of 21 eyes (85.7%). Best spectacle corrected visual acuity of > or = 0.3 was achived in 55.5% in the Verisyse group and in 50.0% of "triple procedure" group. The endothelial cell count and morphology were estimated on the specular microscope on a monthly basis. Mean endothelial cells loss in patients with PK and Verysise was 40 +/- 8% and in patients with "triple" procedure was 42 +/- 12% at 10 postoperative months. There was no significant difference in the endothelial cell loss and clinical outcome between the group of patients who had PK and Verysise as compared to those with implanted PCIOL.  相似文献   

19.
Percutaneous coronary intervention of chronic total occlusions (CTO) is associated with a significantly higher incidence of reocclusion and restenosis compared with non-total occlusions. Randomized and observational trials have demonstrated the effectiveness of intracoronary brachytherapy (ICBT) for the prevention of recurrent in-stent restenosis. However, limited data are available on the effectiveness of ICBT in patients with totally occluded in-stent restenosis. The authors assessed the long-term outcome of patients treated with intracoronary gamma radiation for totally occluded in-stent restenotic lesions. Percutaneous coronary intervention and subsequent catheter-based irradiation with iridium-192 was performed in 100 patients (103 vessels) with diffuse in-stent restenosis. At baseline, CTO of the target vessel at the site of the stent was present in 15 vessels (14.5%). Follow-up data were collected during follow-up visits and from telephone interviews. Repeat coronary angiography was performed in symptomatic patients with clinical restenosis. Clinical and angiographic characteristics were similar between the two groups, although there was a trend towards more unstable angina at the index procedure in CTO patients (66.7% versus 41.4%; p = 0.12) compared with patients without non-total occlusions. A higher percentage of patients (53.3%) with CTO required longer radiation sources (14 seeds, covering a length of 55 mm), compared with 23.9% of patients with non-total occlusion (p = 0.04). With a mean follow-up period of 47.5 +/- 24.0 months, major adverse cardiac events (MACE) were observed in 10 of 15 patients (66.7%) with CTO compared with 25 out of 88 patients (28.4%) without CTO (p = 0.009). According to multivariate analysis, total occlusion of the target vessel at baseline was the single independent predictor of MACE at one-year follow-up (relative risk 16.2, 95% confidence interval 4.2-62.9; p < 0.0001). This study shows that the use of gamma radiation for the prevention of recurrence of in-stent restenosis in patients with CTO does not seem to be as effective as in patients with non-total occlusions. Furthermore, CTO was an independent predictor of worse outcome at long-term follow-up in this study.  相似文献   

20.
The objective of the study was to evaluate the efficacy of endovascular revascularization treatment using drug-eluting stents in patients with atherosclerotic proximal vertebral artery (VA) stenosis. Thirty-two patients (61 ± 10 years old) were implanted with 35 sirolimus and tacrolimus eluting stents (3 patients had them from two sides). 27 patients (84%) had vertebrobasilar symptoms at enrollment. All patients were pretreated with dual antiplatelet therapy. The intervention was technically successful in 89% cases. No stroke, myocardial infarction, or death occurred in perioperative period. On duplex scanning the stents remained completely functional. In the late postoperative period 29 (91%) patients, with 32 implanted stents were followed- up. The mean follow-up was 9.5 months. No stroke occurred in patients during this period. Recurrence of vertebrobasilar insufficiency symptoms was noted in 3 patients. VA renarrowing was detected in 16 (50%) arteries in 15 patients, and 12 (80%) of them were asymptomatic. Restenosis ≥50% (n = 13) and reocclusion (n = 3) were more frequent in those with implantation of tacrolimus eluting stents compared to those with sirolimus eluting stents: 10 (71%) of 14 observations to 6 (33%) of 18 cases (p = 0.1794), respectively. Stent fracture was observed in 2 cases (6%), followed by restenosis. Restenosis rate prevailed in men (p = 0.0173). Thus, stenting of VA extracranial portion is reasonably safe procedure with a good clinical effect. The use of drug-eluting stents looks promising but does not solve the problem of high restenosis rate in the late postoperative period.  相似文献   