首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Clinical and angiographic results with the NIR stent: First International NIR Endovascular Stent Study (FINESS-II)
Authors:Rutsch Wolfgang  Kiemeneij Ferdinand  Colombo Antonio  Macaya Carlos  Guermonprez Jean-Leon  Grip Lars  Hamburger Jaap  Umans Victor  Gotsman Mervyn  Almagor Yaron  Morice Marie-Claude  Garcia Eulogio  Chevalier Bernard  Erbel Raimund  Cobaugh Michael  Morel Marie-Angèle  Serruys Patrick W
Institution:Universit?tsklinikum Charité, Berlin, Germany.
Abstract:BACKGROUND: Although safety and efficacy of the NIR trade mark stent have been reported, the long-term angiographic and clinical outcomes have yet to be investigated. The FINESS-II study (First International NIR Endovascular Stent Study) was designed to assess the procedural safety of single 9 and 16 mm NIR stent implantation, the six-month restenosis rate and finally the six- and 12-month clinical outcome of patients treated with this novel coronary stent. METHODS: Patients with angina and a single de novo lesion in a native coronary artery of >3 and <5 mm diameter were included in this multicentre, prospective, observational trial. Clinical follow-up was obtained at one, six and 12 months. Angiography was performed before and after the stent implantation and at six months. The primary endpoint included major adverse cardiac events (death, myocardial infarction and target lesion revascularization) within 30 days after the procedure. Major bleeding complications and subacute stent thrombosis within the first 30 days were also reported as specific endpoints. Secondary endpoints were major cardiac-event-free survival at six- and 12-month follow-up and angiographic restenosis at six months. RESULTS: A total of 156 patients (81% male, mean age 60 +/- 10 years), with stable (54%), unstable (40%) angina pectoris or silent ischemia (6%) were enrolled. The target vessel diameter was 2.94 +/- 0.54 mm. The minimal lumen diameter pre, post and at follow-up was 1.04 +/- 0.32 mm, 2.64 +/- 0.42 mm and 1.88 +/- 0.63 mm, respectively. Restenosis rate according to the >50% diameter stenosis criterion at six month follow-up was 19% (26/136). At 12 months, the event-free survival rate was 83% (two deaths, one Q-wave and three non-Q-wave myocardial infarctions, four bypass surgery and 17 target lesion revascularizations), while 87% of the patients were free of angina pectoris. CONCLUSION: the outcome of the FINESS-II trial is comparable to those observed in previous stent trials (Benestent II), indicating that the coronary NIR stent is safe and effective as a primary device for the treatment of native coronary artery lesions in patients with (un)stable angina pectoris.
Keywords:
本文献已被 PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号