首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
为探讨胶原海绵对颌下腺 (submandibulargland ,SMG)导管细胞的细胞相容性 ,采用HE染色光镜观察及免疫组化观察SMG导管细胞接种于胶原海绵后 ,细胞的生长情况。光镜下可见接种后第 1d细胞数量较少 ,分散于胶原海绵支架中间 ,第 7d细胞数量明显增加 ,免疫组织化学染色抗IV型胶原抗体染色呈阳性 ,说明细胞与支架材料之间已经有细胞外基质产生。胶原海绵具有良好的细胞相容性 ,是一种理想的支架材料。与胶原海绵复合培养 ,颌下腺导管细胞仍可保持良好的增殖能力。  相似文献   

2.
3.
Particle and cell counting is used for a variety of applications including routine cell culture, hematological analysis, and industrial controls1-5. A critical breakthrough in cell/particle counting technologies was the development of the Coulter technique by Wallace Coulter over 50 years ago. The technique involves the application of an electric field across a micron-sized aperture and hydrodynamically focusing single particles through the aperture. The resulting occlusion of the aperture by the particles yields a measurable change in electric impedance that can be directly and precisely correlated to cell size/volume. The recognition of the approach as the benchmark in cell/particle counting stems from the extraordinary precision and accuracy of its particle sizing and counts, particularly as compared to manual and imaging based technologies (accuracies on the order of 98% for Coulter counters versus 75-80% for manual and vision-based systems). This can be attributed to the fact that, unlike imaging-based approaches to cell counting, the Coulter Technique makes a true three-dimensional (3-D) measurement of cells/particles which dramatically reduces count interference from debris and clustering by calculating precise volumetric information about the cells/particles. Overall this provides a means for enumerating and sizing cells in a more accurate, less tedious, less time-consuming, and less subjective means than other counting techniques6.Despite the prominence of the Coulter technique in cell counting, its widespread use in routine biological studies has been prohibitive due to the cost and size of traditional instruments. Although a less expensive Coulter-based instrument has been produced, it has limitations as compared to its more expensive counterparts in the correction for "coincidence events" in which two or more cells pass through the aperture and are measured simultaneously. Another limitation with existing Coulter technologies is the lack of metrics on the overall health of cell samples. Consequently, additional techniques must often be used in conjunction with Coulter counting to assess cell viability. This extends experimental setup time and cost since the traditional methods of viability assessment require cell staining and/or use of expensive and cumbersome equipment such as a flow cytometer.The Moxi Z mini automated cell counter, described here, is an ultra-small benchtop instrument that combines the accuracy of the Coulter Principle with a thin-film sensor technology to enable precise sizing and counting of particles ranging from 3-25 microns, depending on the cell counting cassette used. The M type cassette can be used to count particles from with average diameters of 4 - 25 microns (dynamic range 2 - 34 microns), and the Type S cassette can be used to count particles with and average diameter of 3 - 20 microns (dynamic range 2 - 26 microns). Since the system uses a volumetric measurement method, the 4-25 microns corresponds to a cell volume range of 34 - 8,180 fL and the 3 - 20 microns corresponds to a cell volume range of 14 - 4200 fL, which is relevant when non-spherical particles are being measured. To perform mammalian cell counts using the Moxi Z, the cells to be counted are first diluted with ORFLO or similar diluent. A cell counting cassette is inserted into the instrument, and the sample is loaded into the port of the cassette. Thousands of cells are pulled, single-file through a "Cell Sensing Zone" (CSZ) in the thin-film membrane over 8-15 seconds. Following the run, the instrument uses proprietary curve-fitting in conjunction with a proprietary software algorithm to provide coincidence event correction along with an assessment of overall culture health by determining the ratio of the number of cells in the population of interest to the total number of particles. The total particle counts include shrunken and broken down dead cells, as well as other debris and contaminants. The results are presented in histogram format with an automatic curve fit, with gates that can be adjusted manually as needed.Ultimately, the Moxi Z enables counting with a precision and accuracy comparable to a Coulter Z2, the current gold standard, while providing additional culture health information. Furthermore it achieves these results in less time, with a smaller footprint, with significantly easier operation and maintenance, and at a fraction of the cost of comparable technologies.  相似文献   

4.
A question was posed as to how the multicomponent and polyfunctional organelle dynamically changes during metazoan ontogenesis. The centrosome structure is gradually formed and its functions are switched on during early embryogenesis, one of which is the cell center formation. During cell differentiation, the condition of the cell center and surrounding structures may be different: first, the cell center is quite distinct; second, the cell center is absent due to redistribution of the microtubule organizing centers; third, the cell center disappears due to reversible or irreversible inactivation of the centrosome and other centers of microtubule organization. The assembly of the Golgi complex does not depend directly to the cell center presence. In some cell types, the Golgi complex is topologically associated with the cell center, while in others it exists as individual dictyosomes despite the cell center presence. In some other cell types, the common Golgi complex is assembled without the cell center, but in the presence of microtubules that are formed by noncentrosome centers of microtubule organization. In still others, degradation of both the cell center and the common Golgi complex takes place in the case of centrosome inactivation.  相似文献   

5.
Counting cells is often a necessary but tedious step for in vitro cell culture. Consistent cell concentrations ensure experimental reproducibility and accuracy. Cell counts are important for monitoring cell health and proliferation rate, assessing immortalization or transformation, seeding cells for subsequent experiments, transfection or infection, and preparing for cell-based assays. It is important that cell counts be accurate, consistent, and fast, particularly for quantitative measurements of cellular responses.Despite this need for speed and accuracy in cell counting, 71% of 400 researchers surveyed1 who count cells using a hemocytometer. While hemocytometry is inexpensive, it is laborious and subject to user bias and misuse, which results in inaccurate counts. Hemocytometers are made of special optical glass on which cell suspensions are loaded in specified volumes and counted under a microscope. Sources of errors in hemocytometry include: uneven cell distribution in the sample, too many or too few cells in the sample, subjective decisions as to whether a given cell falls within the defined counting area, contamination of the hemocytometer, user-to-user variation, and variation of hemocytometer filling rate2.To alleviate the tedium associated with manual counting, 29% of researchers count cells using automated cell counting devices; these include vision-based counters, systems that detect cells using the Coulter principle, or flow cytometry1. For most researchers, the main barrier to using an automated system is the price associated with these large benchtop instruments1.The Scepter cell counter is an automated handheld device that offers the automation and accuracy of Coulter counting at a relatively low cost. The system employs the Coulter principle of impedance-based particle detection3 in a miniaturized format using a combination of analog and digital hardware for sensing, signal processing, data storage, and graphical display. The disposable tip is engineered with a microfabricated, cell- sensing zone that enables discrimination by cell size and cell volume at sub-micron and sub-picoliter resolution. Enhanced with precision liquid-handling channels and electronics, the Scepter cell counter reports cell population statistics graphically displayed as a histogram.  相似文献   

6.
7.
Cell motility is an essential phenomenon in almost all living organisms. It is natural to think that behavioral or shape changes of a cell bear information about the underlying mechanisms that generate these changes. Reading cell motion, namely, understanding the underlying biophysical and mechanochemical processes, is of paramount importance. The mathematical model developed in this paper determines some physical features and material properties of the cells locally through analysis of live cell image sequences and uses this information to make further inferences about the molecular structures, dynamics, and processes within the cells, such as the actin network, microdomains, chemotaxis, adhesion, and retrograde flow. The generality of the principals used in formation of the model ensures its wide applicability to different phenomena at various levels. Based on the model outcomes, we hypothesize a novel biological model for collective biomechanical and molecular mechanism of cell motion.  相似文献   

8.
9.
Cell     
《Cell》1991,65(5):i
  相似文献   

10.
体细胞重编程是在特定的条件下使已分化的细胞转变成为另一种细胞.体细胞重编程的方式主要有体细胞核移植技术、细胞融合技术、细胞提取物处理技术及特定转录因子转染技术.现有研究表明,细胞提取物重编程技术在体细胞重编程中发挥着一定的作用,为此,就该技术的最新研究进展和可能机制作一综述.  相似文献   

11.
12.
Abstract

Mammalian cell culture has been an important technique in laboratory-scale experimentation for many decades. Developments in large-scale culture have been due to the need to grow large numbers of cells to support the growth of viruses for vaccine production, and more recently, for growing hybridoma cells as a source of monoclonal antibody. Increasingly, however, pharmaceutical products such as hormones, enzymes, growth factors, and clotting factors are being produced from cell lines which have been manipulated by recombinant DNA techniques. It is clear, therefore, that the high cost of growing mammalian cells on a large scale does not necessarily prohibit their use for biotechnology, and indeed there is considerable evidence to suggest that animal cell biotechnology will continue to be a major growth area in the future.  相似文献   

13.
14.
干细胞是具有自我更新和分化潜能的异质性细胞群体。基于细胞群体水平的干细胞研究不能满足深入认识干细胞生物学本质及实际应用的需要。近年来,单细胞相关技术不断发展和成熟,并正在干细胞基础研究及其相关领域中获得迅速应用。该文以造血干细胞为主要例举,就实验研究中常用的单细胞分离、单细胞克隆分析、单细胞移植、单细胞实时定量PCR及单细胞测序等技术原理及其应用进行综述。  相似文献   

15.
Mammalian filamins (FLNs) are a family of three large actin-binding proteins. FLNa, the founding member of the family, was implicated in migration by cell biological analyses and the identification of FLNA mutations in the neuronal migration disorder periventricular heterotopia. However, recent knockout studies have questioned the relevance of FLNa to cell migration. Here we have used shRNA-mediated knockdown of FLNa, FLNb or FLNa and FLNb, or, alternatively, acute proteasomal degradation of all three FLNs, to generate FLN-deficient cells and assess their ability to migrate. We report that loss of FLNa or FLNb has little effect on migration but that knockdown of FLNa and FLNb, or proteolysis of all three FLNs, impairs migration. The observed defect is primarily a deficiency in initiation of motility rather than a problem with maintenance of locomotion speed. FLN-deficient cells are also impaired in spreading. Re-expression of full length FLNa, but not re-expression of a mutated FLNa lacking immunoglobulin domains 19 to 21, reverts both the spreading and the inhibition of initiation of migration.Our results establish a role for FLNs in cell migration and spreading and suggest that compensation by other FLNs may mask phenotypes in single knockout or knockdown cells. We propose that interactions between FLNs and transmembrane or signalling proteins, mediated at least in part by immunoglobulin domains 19 to 21 are important for both cell spreading and initiation of migration.  相似文献   

16.
《Biophysical journal》2020,118(12):2894-2904
Cell migration is orchestrated by a complicated mechanochemical system. However, few cell migration models take into account the coupling between the biochemical network and mechanical factors. Here, we construct a mechanochemical cell migration model to study the cell tension effect on cell migration. Our model incorporates the interactions between Rac-GTP, Rac-GDP, F-actin, myosin, and cell tension, and it is very convenient in capturing the change of cell shape by taking the phase field approach. This model captures the characteristic features of cell polarization, cell shape change, and cell migration modes. It shows that cell tension inhibits migration ability monotonically when cells are applied with persistent external stimuli. On the other hand, if random internal noise is significant, the regulation of cell tension exerts a nonmonotonic effect on cell migration. Because the increase of cell tension hinders the formation of multiple protrusions, migration ability could be maximized at intermediate cell tension under random internal noise. These model predictions are consistent with our single-cell experiments and other experimental results.  相似文献   

17.
哺乳动物体细胞核移植中供体细胞的研究进展   总被引:2,自引:0,他引:2  
在哺乳动物体细胞核移植中,供体细胞是影响其效率的主要因素之一。供体细胞的类型、细胞周期、细胞的培养代数、冷藏与冷冻处理,以及供体动物的性别、年龄等都可能影响核移植胚胎的发育。根据现有资料,简要综述了在哺乳动物体细胞核移植中有关供体细胞的研究进展。  相似文献   

18.
19.
20.
在各种组学及其相应的网络研究相对成熟的基础上,集成各组学网络的细胞整合型网络或全细胞网络将大大提高对生物表型的预测能力,并成为代谢工程决策的有力武器.本文在阐述了细胞工厂设计中应该考虑细胞整合网络之后,综述了细胞整合网络的重建、分析、设计方法方面的有关问题,并进一步就研究细胞整合网络涉及的数据库、软件平台、并行计算几方面的作用作了介绍.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号