首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
A thermal comfort field study has been carried out in five cities in the humid subtropical climate zone in China. The survey was performed in naturally ventilated and air-conditioned buildings during the summer season in 2006. There were 229 occupants from 111 buildings who participated in this study and 229 questionnaire responses were collected. Thermal acceptability assessment reveals that the indoor environment in naturally ventilated buildings could not meet the 80% acceptability criteria prescribed by ASHRAE Standard 55, and people tended to feel more comfortable in air-conditioned buildings with the air-conditioned occupants voting with higher acceptability (89%) than the naturally ventilated occupants (58%). The neutral temperatures in naturally ventilated and air-conditioned buildings were 28.3°C and 27.7°C, respectively. The range of accepted temperature in naturally ventilated buildings (25.0∼31.6°C) was wider than that in air-conditioned buildings (25.1∼30.3°C), which suggests that occupants in naturally ventilated buildings seemed to be more tolerant of higher temperatures. Preferred temperatures were 27.9°C and 27.3°C in naturally ventilated and air-conditioned buildings, respectively, both of which were 0.4°C cooler than neutral temperatures. This result suggests that people of hot climates may use words like “slightly cool” to describe their preferred thermal state. The relationship between draught sensation and indoor air velocity at different temperature ranges indicates that indoor air velocity had a significant influence over the occupants’ comfort sensation, and air velocities required by occupants increased with the increasing of operative temperatures. Thus, an effective way of natural ventilation which can create the preferred higher air movement is called for. Finally, the indoor set-point temperature of 26°C or even higher in air-conditioned buildings was confirmed as making people comfortable, which supports the regulation in China that in public and office buildings the set-point temperature of air-conditioning system should not be lower than 26°C.  相似文献   

2.
Air movement preferences observed in office buildings   总被引:1,自引:0,他引:1  
Office workers’ preferences for air movement have been extracted from a database of indoor environmental quality surveys performed in over 200 buildings. Dissatisfaction with the amount of air motion is very common, with too little air movement cited far more commonly than too much air movement. Workers were also surveyed in a detailed two-season study of a single naturally ventilated building. About one-half the building’s population wanted more air movement and only 4% wanted less. This same ratio applied when the air movement in workspaces was higher than 0.2 m/s, the de facto draft limit in the current ASHRAE and ISO thermal environment standards. Preference for “less air motion” exceeded that for “more” only at thermal sensations of −2 (cool) or colder. These results raise questions about the consequences of the ASHRAE and ISO standards’ restrictions on air movement, especially for neutral and warm conditions.  相似文献   

3.

1. 1. Our previous experimental results showed the thermal sensation vote was much less than the values of PMV and SET* at air velocities above 0.5 m/s.

2. 2. The method to modify SET* is presented from the results of subjective experiments taking account of decrease in clo value of summer clothing and decrease in skin wettedness due to increased air velocity.

3. 3. Thermal resistance under increased air movement on a standard summer clothing ensemble was measured. Basic thermal insulation of the summer ensemble was reduced by 25% at air velocity of 1.0 m/s.

4. 4. Thirty-two subjects were exposed at operative temperatures of 27 and 30°C under 1 m/s air movement in order to determine the amount of skin diffusion. Measured evaporation heat loss from skin surface was much smaller at air velocity of 1 m/s than that predicted by SET*.

5. 5. Estimated thermal sensation vote using modified SET* agreed well with our previous experimental results under different air velocities for the same clothing.

Author Keywords: Thermal comfort; air movement; SET*; hot and humid condition  相似文献   


4.
Balancing thermal comfort with the requirement of energy conservation presents a challenge in hot and humid areas where air-conditioning (AC) is frequently used in cooling indoor air. A field survey was conducted in Taiwan to demonstrate the adaptive behaviors of occupants in relation to the use of fans and AC in a school building employing mixed-mode ventilation where AC use was managed under a fee-for-service mechanism. The patterns of using windows, fans, and AC as well as the perceptions of students toward the thermal environment were examined. The results of thermal perception evaluation in relation to the indoor thermal conditions were compared to the levels of thermal comfort predicted by the adaptive models described in the American Society of Heating, Refrigerating, and Air-Conditioning Engineers Standard 55 and EN 15251 and to that of a local model for evaluating thermal adaption in naturally ventilated buildings. A thermal comfort-driven adaptive behavior model was established to illustrate the probability of fans/AC use at specific temperature and compared to the temperature threshold approach to illustrate the potential energy saving the fee-for-service mechanism provided. The findings of this study may be applied as a reference for regulating the operation of AC in school buildings of subtropical regions.  相似文献   

5.
Divergence in the acceptability to people in different regions of naturally ventilated thermal environments raises a concern over the extent to which the ASHRAE Standard 55 may be applied as a universal criterion of thermal comfort. In this study, the ASHRAE 55 adaptive model of thermal comfort was investigated for its applicability to a hot and humid climate through a long-term field survey performed in central Taiwan among local students attending 14 elementary and high schools during September to January. Adaptive behaviors, thermal neutrality, and thermal comfort zones are explored. A probit analysis of thermal acceptability responses from students was performed in place of the conventional linear regression of thermal sensation votes against operative temperature to investigate the limits of comfort zones for 90% and 80% acceptability; the corresponding comfort zones were found to occur at 20.1–28.4°C and 17.6–30.0°C, respectively. In comparison with the yearly comfort zones recommended by the adaptive model for naturally ventilated spaces in the ASHRAE Standard 55, those observed in this study differ in the lower limit for 80% acceptability, with the observed level being 1.7°C lower than the ASHRAE-recommended value. These findings can be generalized to the population of school children, thus providing information that can supplement ASHRAE Standard 55 in evaluating the thermal performance of naturally ventilated school buildings, particularly in hot-humid areas such as Taiwan.  相似文献   

6.
This paper presents the findings of an outdoor thermal comfort study conducted in Hong Kong using longitudinal experiments—an alternative approach to conventional transverse surveys. In a longitudinal experiment, the thermal sensations of a relatively small number of subjects over different environmental conditions are followed and evaluated. This allows an exploration of the effects of changing climatic conditions on thermal sensation, and thus can provide information that is not possible to acquire through the conventional transverse survey. The paper addresses the effects of changing wind and solar radiation conditions on thermal sensation. It examines the use of predicted mean vote (PMV) in the outdoor context and illustrates the use of an alternative thermal index—physiological equivalent temperature (PET). The paper supports the conventional assumption that thermal neutrality corresponds to thermal comfort. Finally, predictive formulas for estimating outdoor thermal sensation are presented as functions of air temperature, wind speed, solar radiation intensity and absolute humidity. According to the formulas, for a person in light clothing sitting under shade on a typical summer day in Hong Kong where the air temperature is about 28°C and relative humidity about 80%, a wind speed of about 1.6 m/s is needed to achieve neutral thermal sensation.  相似文献   

7.
8.
Seasonal variations of human thermal characteristics were inspected in thermal comfort and when constantly indoors. Metabolic rate, tympanic temperature, skin temperature, body fat, body weight and thermal sensation were measured under identical thermal conditions in a chamber over the course of one year. Experiments were carried out for each subject in both summer and winter. Six subjects were measured 35 times in summer and 45 times in winter. one subject was measured weekly for 14 months. Measurements for analyses were taken 40-60 min after entrance into the chamber. Results revealed the following. 1) For all subjects, the metabolic rate, tympanic temperature and body fat were lower in summer than in winter; thigh skin temperatures were higher in summer than in winter. The averaged individual ratio of seasonal difference was 11.9% for metabolic rate, 14.9% for body fat, 1.8% for thigh temperature and 0.53% for tympanic temperature. Seasonal differences of about 10% in metabolic rate were maintained in this study. 2) Seasonal variations of the variables were examined for phase relationships against the outdoor temperature. 2-1) Metabolic rate, thermal sensation, body weight and body fat changed in reverse phase, whereas skin temperature was in-phase. 2-2) Skin temperature lagged by about one month in both summer and winter. Body fat also lagged by about one month in summer, but corresponded to the phase in winter. Metabolic rates were also in-phase in winter but led about three months in summer. Thermal sensations lagged by about three months in winter but were in-phase in summer. Body weight was in-phase in summer and winter. 2-3) Summer disorders were observed particularly in seasonal variations of metabolic rates, tympanic temperature, skin temperatures, and thermal sensation, thereby suggesting that the effect of temperature exposure was altered by air-conditioner use.  相似文献   

9.
Consideration of urban microclimate and thermal comfort is an absolute neccessity in urban development, and a set of guidelines for every type of climate must be elaborated. However, to develop guidelines, thermal comfort ranges need to be defined. The aim of this study was to evaluate the behaviour of different thermal indices by investigating different thermal environments in Damascus during summer and winter. A second aim was to define the lower and upper limits of the thermal comfort range for some of these indices. The study was based on comprehensive micrometeorological measurements combined with questionnaires. It was found that the thermal conditions of different outdoor environments vary considerably. In general, Old Damascus, with its deep canyons, is more comfortable in summer than modern Damascus where there is a lack of shade. Conversely, residential areas and parks in modern Damascus are more comfortable in winter due to more solar access. The neutral temperatures of both the physiologically equivalent temperature (PET) and the outdoor standard effective temperature (OUT_SET*) were found to be lower in summer than in winter. At 80 % acceptability, the study defined the lower comfort limit in winter to 21.0 °C and the upper limit in summer to 31.3 °C for PET. For OUT_SET*, the corresponding lower and upper limits were 27.6 °C and 31.3 °C respectively. OUT_SET* showed a better correlation with the thermal sensation votes than PET. The study also highlighted the influence of culture and traditions on people’s clothing as well as the influence of air conditioning on physical adaptation.  相似文献   

10.

1. 1. The authors propose humidity reduction instead of lowering room temperature in order to reduce cooling syndrome.

2. 2. They conducted experiments with subjects in the rooms, one with controlling humidity to about 40% r.h. and another without humidity control. Air-conditioning system with humidity control has a greater promise in making a comfortable environment, even at the temperature as high as 30°C, in comparison with conventional means using temperature control alone.

3. 3. Relationship of actual mean votes on temperature sensation and comfort sensation with PMV and SET, respectively, suggests that Japanese people might be more sensitive to humidity than Westerners and so different methods from those used in the western countries should be required for human thermal environmental studies with respect to the hot humid summer in Japan.

Author Keywords: Subjective experiments; thermal sensations; humidity reduction; thermal indices; hot humid climate  相似文献   


11.
The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.  相似文献   

12.
刘畅  徐宁  宋靖达  胡尚春 《生态学报》2017,37(10):3561-3569
选择黑龙江省森林植物园内景观差异性较大的4个样地。实地测量各样地空气温度、相对湿度、风速等小气候要素数据,问卷调查游人热舒适感受,观察记录游人空间选择及行为特征。旨在寻找小气候要素与人体热舒适感受的关系,以及游人空间选择与热舒适感受评价的关联程度。结果表明:各小气候要素均对游人热舒适感受有一定的影响,其中空气温度对游人热舒适感受影响最大,其次是相对湿度和风速;不同样地内游人对热舒适感受变化的敏感程度不同,水体和植物群落除了通过増湿降温作用调节空间热舒适感受外,其观赏作用也可以降低人们对热舒适感受变化的敏感性;遮荫是夏季游人选择休憩空间的主要因素。  相似文献   

13.
This paper presents findings of a study of thermal discomfort and preferences in housing in the humid tropics. The study was conducted in Darwin, Australia. Thirty-one households, approximately half with fully airconditioned houses and half without airconditioning, were involved in the study. Data were collected by interviews, which covered topics such as use patterns of airconditioners and attitudes to airconditioning; and by comfort vote loggers, electronic devices which record temperature and humidity, and house-occupants' clothing and activity levels, experience of air movement, and vote on a thermal discomfort scale.Findings illustrate that mathematical models of thermal sensation, such as Gagge's DISC and the International Organization for Standardization's predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), are of limited use as aids in the prediction of thermal preferences in Darwin housing. For example, they cannot answer the important question of whether or not airconditioning is necessary. A major reason for this limited usefulness appears to be the lack of any predictable relationship between thermal preference and thermal discomfort or thermal sensation.  相似文献   

14.
A variety of research has linked high temperature to outdoor thermal comfort in summer, but it remains unclear how outdoor meteorological environments influence people's thermal sensation in subtropical monsoon climate areas, especially in China. In order to explain the process, and to better understand the related influential factors, we conducted an extensive survey of thermally comfortable conditions in open outdoor spaces. The goal of this study was to gain an insight into the subjects' perspectives on weather variables and comfort levels, and determine the factors responsible for the varying human thermal comfort response in summer. These perceptions were then compared to actual ambient conditions. The database consists of surveys rated by 205 students trained from 6:00 am to 8:00 pm outdoors from 21 to 25 August 2009, at Nanjing University of Information Science & Technology (NUIST), Nanjing, China. The multiple regression approach and simple factor analysis of variance were used to investigate the relationships between thermal comfort and meteorological environment, taking into consideration individual mood, gender, level of regular exercise, and previous environmental experiences. It was found that males and females have similar perceptions of maximum temperature; in the most comfortable environment, mood appears to have a significant influence on thermal comfort, but the influence of mood diminishes as the meteorological environment becomes increasingly uncomfortable. In addition, the study confirms the strong relationship between thermal comfort and microclimatic conditions, including solar radiation, atmospheric pressure, maximum temperature, wind speed and relative humidity, ranked by importance. There are also strong effects of illness, clothing and exercise, all of which influence thermal comfort. We also find that their former place of residence influences people's thermal comfort substantially by setting expectations. Finally, some relationships between thermal perception and amount of exercise, thermal experience, mood, clothing, illness and microclimate, etc., are established. Our findings also shed light on how to resist or adapt to outdoor hyperthermic conditions during summer in subtropical monsoon climate areas.  相似文献   

15.
This study was conducted to obtain basic data in improving the health of Koreans, saving energy and protecting environments. This study investigated the effects of wearing thermal underwear for keeping warm in the office in winter where temperature is not as low as affecting work efficiency, on thermoregulatory responses and subjective sensations. In order to create an environment where every subject feels the same thermal sensation, two experimental conditions were selected through preliminary experiments: wearing thermal underwear in 18 degrees C air (18-condition) and not wearing thermal underwear in 23 degrees C air (23-condition). Six healthy male students participated in this study as experiment subjects. Measurement items included rectal temperature (T(re)), skin temperature (T(sk)), clothing microclimate temperature (T(cm)), thermal sensation and thermal comfort. The results are as follows: (1) T(re) of all subjects was maintained constant at 37.1 degrees C under both conditions, indicating no significant differences. (2) (T)(sk) under the 18-condition and the 23-condition were 32.9 degrees C and 33.7 degrees C, respectively, indicating a significant level of difference (p<0.05). (3) Among local skin temperature, trunk part (forehead and abdomen) did not show significant differences. After 90-min exposure, the skin temperature of hands and feet under the 18-condition was significantly lower than that under the 23-condition (p<0.001). (4) More than 80% of all the respondents felt comfortable under both conditions. It was found (T)(sk) decreased due to a drop in the skin temperature of hands and feet, and the subjects felt cooler wearing only one layer of normal thermal underwear at 18 degrees C. Yet, the thermal comfort level, T(re) and T(cm) of chest part under the 18-condition were the same as those under the 23-condition. These results show that the same level of comfort, T(re) and T(cm) can be maintained as that of an environment about 5 degrees C higher in the office in winter, by wearing one layer of thermal underwear. In this regard, this study suggests that lowering indoor temperature by wearing thermal underwear in winter can contribute to saving energy and improving health.  相似文献   

16.
This paper reports on studies of the effect of temperature step-change (between a cool and a neutral environment) on human thermal sensation and skin temperature. Experiments with three temperature conditions were carried out in a climate chamber during the period in winter. Twelve subjects participated in the experiments simulating moving inside and outside of rooms or cabins with air conditioning. Skin temperatures and thermal sensation were recorded. Results showed overshoot and asymmetry of TSV due to the step-change. Skin temperature changed immediately when subjects entered a new environment. When moving into a neutral environment from cool, dynamic thermal sensation was in the thermal comfort zone and overshoot was not obvious. Air-conditioning in a transitional area should be considered to limit temperature difference to not more than 5°C to decrease the unacceptability of temperature step-change. The linear relationship between thermal sensation and skin temperature or gradient of skin temperature does not apply in a step-change environment. There is a significant linear correlation between TSV and Qloss in the transient environment. Heat loss from the human skin surface can be used to predict dynamic thermal sensation instead of the heat transfer of the whole human body.  相似文献   

17.

1. 1. An investigation was carried out on 3 male and 4 female elderly people, from 65 to 78 years ol.d The first survey was made in August and September of 1990 (in summer) and the second in January and February of 1991 (in winter).

2. 2. Matters for investigation were human subjects and thermal environmental elements of houses which were recorded by a portable thermo-recorder and a vinyl resin globe thermometer. Dry bulb temperatures at a height of 0.1 and 1.2 m and wet bulb and globe temperatures at 1.2 m high were recorded in the living room, bedroom, toilet etc., the thermo-recorders which measured air and wet bulb temperatures were kept out of the sun.

3. 3. Data was recorded constantly for 7 days at 20 min intervals. Plans of houses and furniture arrangement which influence the thermal conditions were drawn from video recordings. Physical and psychological surveys of individuals were carried out over 2 days of daily life.

4. 4. Subjects carried the thermo-recorders (YM1, YM2) on their side. Rectal, back of hand, sole of foot and ambient temperatures were measured every 2 min and with thermistor sensors. At the same time, behaviour and clothes, assessment of thermal sensation, comfort sensation and sensation of estimated room temperature were reported.

5. 5. Thermal radiation was measured with thermographs during the winter. Human activity was recorded every minute for 33 h. This report is the result of surveys in summer and winter.

6. 6. The following results were obtained: (i) the air conditioning is used sometimes in the houses of the elderly; (ii) thermal sensation range reported is narrow; (iii) skin surface temperatures of the elderly are relatively high and their range of change is narrow, and the range of rectal temperature in a day is narrow; (iv) high activity and excessive heating cause a rise of rectal temperature and the rectal temperatures are lower at rest time.

Author Keywords: Thermal environment; residential thermal environments; the elderly  相似文献   


18.
Plant growth and development are proportional to biological time, or the thermal time of the species, which can be defined as the integral of the temperature over time between the lower and upper temperature developmental thresholds. The objective of this study was to investigate the efficiency of the growing degree-day (GDD) approach for vines of the ‘Niagara Rosada’ cultivar pruned in winter and summer seasons, and physiological phases (mobilisation and reserve accumulation) in a humid subtropical region. The experiment was carried out on 13-year-old plants in Piracicaba, São Paulo State-Brazil, evaluating 24 production cycles, 12 from the winter pruning, and 12 from the summer pruning. The statistical design was comprised of randomised blocks, using the pruning dates as treatment: 20 July, 4 August, 19 August, and 3 September (winter); 1 February, 15 February, 2 March, and 16 March (summer). Comparison of the mean values of GDD among pruning dates was evaluated by the Tukey test, and comparison between pruning seasons was made by the F test for orthogonal contrasts, both at the 5% probability level. The results showed good agreement between the values of GDD required to complete the cycle from the winter pruning until harvest when compared with other studies performed with the same cultivar grown in the Southern and Southeastern regions of Brazil. However, there was a consistent statistical difference between GDD computed for winter and summer pruning, which allowed us to conclude that this bio-meteorological index is not sufficient to distinguish vines pruned in different seasons and physiological phases applied in humid subtropical climates.  相似文献   

19.
Many field surveys have shown that naturally ventilated buildings are favorable to human thermal comfort and may allow higher cooling temperatures than air-conditioned buildings. Recreating natural wind characteristics with a mechanical cooling system may diminish the drawbacks of conventional cooling systems such as drafts and high energy demands.Natural wind characteristics (wind velocity, direction, turbulent intensity, temperature and relative humidity) were recorded in a mountain environment and correlated with the human thermal sensation of 48 subjects. Natural wind fluctuation characteristics were analyzed using the Fast Fourier Transform (FFT) analysis. The dynamic characteristics of natural wind were averaged through the power spectrum exponent (β−value), which represents the energy distribution of the turbulent flow of natural wind. The power spectrum exponent (β−value) of the natural wind will decrease when the mean velocity increases, while it will increase when the turbulent intensity increases. The power spectrum exponent (β−value) was correlated (Spearman's rank coefficient=0.56, p<0.001) with thermal comfort. The power spectrum exponent (β-value) for people feeling comfortable has a median value of 1.62 [1.41–1.80 for the first and third quartiles, respectively] and the β−value for people feeling uncomfortable has a median value of 1.10 [0.97–1.25].  相似文献   

20.
The effects of solar radiation on thermal comfort   总被引:1,自引:0,他引:1  
The aim of this study was to investigate the relationship between simulated solar radiation and thermal comfort. Three studies investigated the effects of (1) the intensity of direct simulated solar radiation, (2) spectral content of simulated solar radiation and (3) glazing type on human thermal sensation responses. Eight male subjects were exposed in each of the three studies. In Study 1, subjects were exposed to four levels of simulated solar radiation: 0, 200, 400 and 600 Wm−2. In Study 2, subjects were exposed to simulated solar radiation with four different spectral contents, each with a total intensity of 400 Wm−2 on the subject. In Study 3, subjects were exposed through glass to radiation caused by 1,000 Wm−2 of simulated solar radiation on the exterior surface of four different glazing types. The environment was otherwise thermally neutral where there was no direct radiation, predicted mean vote (PMV)=0±0.5, [International Standards Organisation (ISO) standard 7730]. Ratings of thermal sensation, comfort, stickiness and preference and measures of mean skin temperature (tsk) were taken. Increase in the total intensity of simulated solar radiation rather than the specific wavelength of the radiation is the critical factor affecting thermal comfort. Thermal sensation votes showed that there was a sensation scale increase of 1 scale unit for each increase of direct radiation of around 200 Wm−2. The specific spectral content of the radiation has no direct effect on thermal sensation. The results contribute to models for determining the effects of solar radiation on thermal comfort in vehicles, buildings and outdoors.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏