首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A water‐soluble sulphonato‐(salen)manganese(III) complex with excellent catalytic properties was synthesized and demonstrated to greatly enhance the chemiluminescence signal of the hydrogen peroxide ? luminol reaction. Coupled with flow‐injection technique, a simple and sensitive chemiluminescence method was first developed to detect hydroquinone based on the chemiluminescence system of the hydrogen peroxide–luminol–sulphonato‐(salen)manganese(III) complex. Under optimal conditions, the assay exhibited a wide linear range from 0.1 to 10 ng mL–1 with a detection limit of 0.05 ng mL–1 for hydroquinone. The method was applied successfully to detect hydroquinone in tap‐water and mineral‐water, with a sampling frequency of 120 times per hour. The relative standard deviation for determination of hydroquinone was less than 5.6%, and the recoveries ranged from 96.8 to 103.0%. The ultraviolet spectra, chemiluminescence spectra, and the reaction kinetics for the peroxide–luminol–sulphonato‐(salen)manganese(III) complex system were employed to study the possible chemiluminescence mechanism. The proposed chemiluminescence analysis technique is rapid and sensitive, with low cost, and could be easily extended and applied to other compounds. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

2.
We developed a highly sensitive chemiluminescent (CL) assay for hydrogen peroxide using 10‐methyl‐9‐(phenoxycarbonyl) acridinium fluorosulfonate (PMAC) that produced chemiluminescence under neutral conditions and applied it to an enzyme immunoassay (EIA). One picomole of hydrogen peroxide could be detected using the optimized PMAC‐CL method and 6.2 × 10‐20 mol β‐d ‐galactosidase (β‐gal) could be detected by combining an indoxyl derivative substrate and the proposed PMAC‐CL method. This highly sensitive CL β‐gal assay was applied to an EIA for thyroid‐stimulating hormone (TSH) using β‐gal as a label enzyme; 0.02–100.0 μU/mL TSH in human serum could be assayed directly and with high reproducibility. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

3.
The effects of various boronate compounds, 4-biphenylboronic acid, 4-bromobenzeneboronic acid, trans-4-(3-propionic acid)phenylboronic acid and 4-iodophenylboronic acid, on the horseradish peroxidase (HRP) catalysed chemiluminescent oxidation of pyrogallol and purpurogallin by peroxide were investigated. trans-4-(3-Propionic acid)phenylboronic acid produced a 13.7-fold enhancement in the peak light emission from the chemiluminescent HRP catalysed pyrogallol reaction (detection limit for HRP < 1.25 fmol). At low enhancer concentration a single peak of light emission was observed and as the enhancer concentration increased the time to peak light emission became progressively longer. The chemiluminescence showed two peaks at higher concentrations (> 54.3 μmol/L) and the individual peak times depended upon the concentration of the enhancer. All of the boronates enhanced peak light emission in the chemiluminescent HRP catalysed purpurogallin reaction. 4-Biphenylboronic acid was the most effective and it enhanced peak light emission 314-fold. The practical detection limit for HRP (Type VIA) using this enhancer was 4.18 pmol (peak emission at 20 minutes). This compound also enhanced peak light emission 232-fold from a chemiluminescent HRP-purpurogallin reaction in which molecular oxygen replaced peroxide as the oxidant.  相似文献   

4.
The 3‐aminophthalic acid anion is a light emitter in luminol chemiluminescence. In the present study, the chemiluminescence of the 3‐aminophthalic acid anion itself in the presence of hydrogen peroxide–cobalt (II) was studied. The results indicated that 3‐aminophthalic acid anion is highly chemiluminescent in the typical hydrogen peroxide–cobalt (II) system. The peak wavelength of this chemiluminescence and the kinetic profile of the 3‐aminophthalic acid anion–hydrogen peroxide–cobalt (II) reaction showed similarity with that of luminol, but the chemiluminescence of 3‐aminophthalic acid anion had a much lower background signal. In addition, the chemiluminescence mechanism of 3‐aminophthalic acid anion–hydrogen peroxide–cobalt (II) was also discussed and speculated as the interaction between 3‐aminophthalic acid anion and singlet oxygen.  相似文献   

5.
Commercial chemiluminescent reagents emit across a broad portion of the electromagnetic spectrum (400–500 nm). A challenge to the use of chemiluminescence to monitor biological processes is the presence of interfering substances in the biological optical window. In the present study, longer wavelength emitting fluorophores (the organic dyes Alexa 568 and Alexa 647), and a semiconductor nanoparticle (QDOT800) were used to red‐shift the emission from commercially available 1,2‐dioxetane‐based chemiluminescent substrate reactions. By adding non‐conjugated fluorescent emitters into chemiluminescent reaction mixtures, an emission peak occurred at the predicted wavelength of the fluorescent emitter. The excitation and emission from QDOT800 was preserved in the presence of a 100 µm‐thick glass barrier separating it from the chemiluminescent reaction components. The maximum tissue phantom penetration by QDOT800 emission was 8.5 mm; in comparison, the native chemiluminescent emission at 500 nm was unable to penetrate the thinnest tissue phantom of 2.5 mm. The described method for red‐shifted emissions from chemiluminescent reactions does not require direct interaction between the chemiluminescent reaction and the fluorescent emitters. This suggests that the mechanism of chemiluminescent excitation of fluorophores and QDOT800 is not exclusive to chemiluminescence resonance energy transfer or sensitized chemiluminescence, but rather by broad energization from the native chemiluminescent emission. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

6.
A rapid, economic and sensitive chemiluminescent method involving flow‐injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly alkaline medium, in which vanadium(IV) acts as a catalyst. Principal chemical and physical variables involved in the flow‐injection system were optimized using a modified simplex method. The variations in the quantum yield observed when dipyrone was present in the reaction medium were used to determine the concentration of this compound. The proposed method requires no preconcentration steps and reliably quantifies dipyrone over the linear range 1–50 µg/mL. In addition, a sample throughput of 85 samples/h is possible. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

7.
Hydrogen peroxide amplifies the chemiluminescence in the oxidation of luminol by sodium hypochlorite. A linear relationship between concentration of hydrogen peroxide and light intensity was found in the concentration range 5 × 10?8?7.5 × 10?6 mol/l. At 7.5 × 10?6 mol/l H2O2 the chemiluminescence is amplified 550—fold. The chemiluminescence spectra of these reactions have a wavelength maximum at 431 nm independent of the concentration of hydrogen peroxide. The results indicate that hydrogen peroxide is a necessary component in the chemiluminescent oxidation of the luminol by sodium hypochlorite.  相似文献   

8.
《Luminescence》2003,18(3):125-130
A new flow injection chemiluminescent method has been developed for the determination of procaine hydrochloride, based on the inhibition of the chemiluminescence reaction of luminol–hydrogen peroxide by procaine hydrochloride. The influence of several surfactants and β‐cyclodextrin on the chemiluminescence intensity were studied. It was found that β‐cyclodextrin enhanced the decrease in chemiluminescence intensity. The method is simple, convenient and sensitive, with a detection limit (3 σ) of 0.08 µg/mL. The decreased chemiluminescence intensity is linear, with the concentration of procaine hydrochloride in the range 0.2–100.0 µg/mL and 100.0–400.0 µg/mL. The relative standard deviation for 10 repeated measurements were 4.5% and 3.4% for 1.0 and 20.0 µg/mL procaine hydrochloride, respectively. The method has been successfully applied to the determination of procaine hydrochloride in injection solutions of this drug. Copyright © 2003 John Wiley & Sons, Ltd.  相似文献   

9.
Acridinium salts, due to their chemiluminogenic properties, have found several applications in biomedical analysis as labels and indicators, where the assessment of emission intensity is used for the end‐point detection. This work presents the use of chemiluminescent indicators in the form of selected acridinium esters in order to determine the antioxidant properties of exemplary formulations, namely quercetin, vitamin C and the dietary supplement, Apiextract. The principle of measurements is based on a change in the kinetics of emission decay derived from the acridinium cations in alkaline solutions of hydrogen peroxide in the presence of an antioxidant (the analyte). The proposed system makes a beneficial alternative to related methods, which mostly rely on the assessment of emission efficiency and use the luminometric standard luminol – due to superior parameters of acridinium chemiluminescence, among others ‐ high temporary emission efficiency. The features of the proposed method are manifested by a shorter time period of analysis and lower background signals associated with the environmental influences, as compared to typical approaches. The chromatographic (RP‐HPLC) analyses of the substrates and products generated during chemiluminogenic oxidation of acridinium cations under assay conditions are also presented.  相似文献   

10.
Melanins protect tissue by absorption and rapid nonradiative, nonreactive dissipation of ultraviolet (UV) light. However, melanins also produce reactive oxygen species (ROS) upon UV illumination. A chemical understanding of this dichotomy of photoprotection and phototoxicity has not been established. Herein this issue is examined by studying the UV-B induced oxidation and reduction of cytochrome c by ROS generated by different aggregation states of eumelanin. The quantum yield for superoxide anion by unaggregated oligomers is 7.4 x 10(-3), an order of magnitude greater than that characteristic of the bulk pigment. The quantum efficiency of hydrogen peroxide production by oligomers is 5.7 x 10(-3), and its production is attributed to reaction between superoxide anion and hydroquinone groups on eumelanin oligomers. Aggregation of oligomers results in a reduction of these quantum yields, having a significantly greater effect on the efficiency of hydrogen peroxide production. This effect is attributed to the decrease in surface concentration of hydroquinone sites upon aggregation. The effect of aggregation on the photogeneration of ROS serves to provide a foundation for the understanding of the dichotomy of photoprotective and phototoxic properties of melanin.  相似文献   

11.
A highly sensitive and simple chemiluminescent method for the quantitation of lipid hydroperoxides at the picomole level is described. The method is based on detecting the chemiluminescence generated during the oxidation of luminol by the reaction with hydroperoxide and cytochrome c under mild conditions. A semilogarithmic relationship was observed between the hydroperoxide added and the chemiluminescence produced. For lipid hydroperoxides, cytochrome c was a most favorable catalyst for generating the chemiluminescence, rather than cytochrome c heme peptide and horseradish peroxidase. This method had high sensitivity to methyl linoleate hydroperoxide, arachidonic acid hydroperoxide and cholesterol hydroperoxide, but low to /-butyl hydroperoxide, J-butyl perbenzoate, diacyl peroxides (lauroyl peroxode and benzoyl peroxide) and dialkyl peroxides (di-/-butyl peroxide and dicumyl peroxide).  相似文献   

12.
Today, chemiluminescence detection reactions have become popular in analytical biochemistry essentially due to their high sensitivity. A chemiluminescent synthetic system (luminol/porphyrin) was successfully used to measure serum oxalate by determination of hydrogen peroxide generated through oxalate oxidase (EC 1.2.3.4.). This new method is efficient and simple, highly sensitive and the results obtained in normal adult subjects are in good agreement with those of approved methods. This original application of such a chemiluminescent system allowed us to achieve a sensitive serum oxalate assay (detection limit of 0.2 μmol/L) characterized by a low serum volume (200 μL) required for analysis. © 1997 John Wiley & Sons, Ltd.  相似文献   

13.
We optimized the conditions for oxidation of luminol by hydrogen peroxide in the presence of peroxidase (EC 1.11.1.7) from royal palm leaves (Roystonea regia). The pH range (8.3–8.6) corresponding to maximum chemiluminescence was similar for palm tree peroxidase and horseradish peroxidase. Variations in the concentration of the Tris buffer were accompanied by changes in chemiluminescence. Note that maximum chemiluminescence was observed in the 30 mM Tris solution. The detection limit of the enzyme assay during luminol oxidation by hydrogen peroxide was 1 pM. The specific feature of palm tree peroxidase was the generation of a long-term chemiluminescent signal. In combination with the data on the high stability of palm tree peroxidase, our results indicate that this enzyme is promising for its use in analytical studies.  相似文献   

14.
In this study, a high sensitivity chemiluminescence enzyme immunoassay (CLEIA) based on novel enhancers was developed. Under optimal conditions, we developed an enhanced chemiluminescence reaction (ECR) catalyzed by horseradish peroxidase (HRP‐C) in the presence of 3‐(10'‐phenothiazinyl) propane‐1‐sulfonate (SPTZ) and 4‐morpholinopyridine (MORP) as enhancers. The limit of detection of the newly prepared chemiluminescent cocktail for HRP was 0.33 pg/well, which is lower than that of commercial Super Signal substrate. The results showed that this novel chemiluminescent cocktail can significantly increase the light output of HRP‐catalyzed ECR, which can be translated into a corresponding improvement in sensitivity. Similar improvements were observed in CLEIA for the determination of chloramphenicol in milk. In addition, the ECR of N‐azoles as secondary enhancer was also presented. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

15.
Assays of peroxy compounds are commonly performed after chromatographic separation of analysed mixtures. In high‐performance liquid chromatography (HPLC), solvent reservoirs are sparged by helium or inline vacuum‐degassed in order to control the compressibility of the solvents for efficient pumping. In this study, we investigated the influence of degassing the reaction solution on the light output of the hemin‐catalyzed luminol oxidation by various oxidants. We found that, when t‐butyl hydroperoxide, hydrogen peroxide, n‐butyl hydroperoxide, iodosobenzene and iodobenzene diacetate were used as oxidants, the luminol chemiluminescence was lowered by 50–70% compared with an equilibrated and degassed solution. The opposite effect was observed when dibenzoyl peroxide and 3‐chloroperoxybenzoic acid were used as oxidants, as the chemiluminescence increased by approximately 20–30%. The reduced chemiluminescence was explained based on the known role of dioxygen in luminol chemiluminescence. The enhancement of chemiluminescence was rationalized by suggesting an alternative mechanism of luminol oxidation valid for peroxyacids and diacyl peroxides in which the reaction of a peroxyacid anion with the diazaquinone led to light emission with a higher quantum yield than the usual path, which is suppressed by the removal of dioxygen from the reaction solution. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

16.
Indolizine derivatives are of great interest as fluorescent emitters for peroxyoxalate chemiluminescence. The reaction of peroxyoxalates such as bis‐(2,4,6‐trichlorophenyl) oxalate (TCPO) with H2O2 can transfer energy to fluorescer via the formation of dioxetanedione intermediate. Four indolizine derivatives were used as a novel fluorescer in the chemiluminescence (CL) systems in this study. The relationship between CL intensity and the concentration of fluorescer, peroxyoxalate, sodium salicylate and hydrogen peroxide was investigated. Optimum conditions were obtained for four fluorescers and it was found that the indolizine can be used as an efficient green fluorescence emitter. Vitamin B6 induces a sharp decrease in the CL intensity of the TCPO–hydrogen peroxide–sodium salicylate system. A simple, rapid and sensitive CL method for the determination of vitamin B6 has been developed. The results showed a linear relationship between vitamin B6 concentration and peroxyoxalate CL intensity in the range 7.0 × 10−8–1.0 × 10−4. A detection limit of 2.3 × 10−8 M and relative standard deviation (RSD) of < 4.5% were obtained. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
We optimized the conditions for luminol oxidation by hydrogen peroxide in the presence of peroxidase (EC 1.11.1.7) from royal palm leaves (Roystonea regia). The pH range (8.3-8.6) corresponding to maximum chemiluminescence was similar for palm tree peroxidase and horseradish peroxidase. Variations in the concentration of the Tris buffer were accompanied by changes in chemiluminescence. Note that maximum chemiluminescence was observed in the 30 mM solution. The detection limit of the enzyme assay during luminol oxidation by hydrogen peroxide was 1 pM. The specific feature of palm tree peroxidase was the generation of a long-term chemiluminescent signal. In combination with the data on the high stability of palm tree peroxidase, our results indicate that this enzyme is promising for its use in analytical studies.  相似文献   

18.
The extract of the luminous mushroom Panellus stipticus wasonly slightly chemiluminescent but, when treated with methylamine,it developed a strong capability of chemiluminescence whichcorresponds to the total light emission in 4–5 h fromthe fresh, brightly luminescing specimens before extraction.The chemiluminescent compounds thus formed, as well as the precursorcompounds that yielded the chemiluminescent compounds, werepurified and their properties were investigated. The purifiedchemiluminescent compounds (3 kinds) were orange coloured solids(absorption maxima 210 nm and 488 nm) and showed yellowish fluorescence(emission maximum 520–530 nm) when dissolved in variousorganic solvents or in aqueous buffer solutions containing asurfactant. The precursor compounds (2 kinds) were colourlessoils (absorption maximum 215 nm) and non-fluorescent. The chemiluminescencereaction in aqueous pH 8?0 buffer solutions required the presenceof , O2, and a surfactant. The spectral distributionand intensity of chemiluminescence was significantly affectedby the type of surfactant used, resulting in emission peaksof various intensities in a broad wavelength range of 480 nmto 530 nm. Various lines of evidence suggest that the chemiluminescencereaction studied might be closely related with the bioluminescencereaction of P. stipticus (emission maximum 530 nm). Key words: Superoxide anion, chemiluminescence, bioluminescence, luminous fungi  相似文献   

19.
Addition of oxygen to whole cells of Escherichia coli suspended in the presence of the chemiluminescent probe bis-N-methylacridinium nitrate (lucigenin) resulted in a light emission increase of 200% of control. Addition of air to cells showed a chemiluminescent response far less than the response to oxygen. The redox cycling agents paraquat and menadione, which are known to increase intracellular production of O2- and H2O2, were also found to cause a measurable increase in lucigenin chemiluminescence in E. coli cells when added at concentrations of 1 and 0.1 mM, respectively. The oxygen-induced chemiluminescent response was not suppressed by extracellularly added superoxide dismutase or catalase. Further, the lucigenin-dependent chemiluminescent response of aerobically grown E. coli to oxygen was significantly greater than that of cells grown anaerobically. Heat-killed cells showed no increase in chemiluminescence on the addition of either oxygen, paraquat, or menadione. These results show that lucigenin may be used as a chemiluminescent probe to demonstrate continuous intracellular production of reactive oxygen metabolites in E. coli.  相似文献   

20.
A system was designed for chemiluminescent measurement of lipid hydroperoxides by their site-specific reaction in sodium dodecylsulfate micelles. Ferrous ion-induced decomposition of lipid hydroperoxides in the sodium dodecylsulfate micelles resulted in strong chemiluminescence of the Cypridina luciferin analog, 2-methyl-6-phenyl-3,7-dihydroimidazo[1,2-alpha]pyrazin-3-one (CLA). After addition of ferrous sulfate to the micelles containing lipid hydroperoxide and luciferin, the chemiluminescence intensity reached a maximum rapidly and then decreased. The sequence of this reaction was elucidated by theoretical analysis, which demonstrated that the maximum chemiluminescence intensity is proportional to the initial concentration of hydroperoxide. Good linear relationships were observed between the maximum counts of chemiluminescence and the amounts of hydroperoxides of linoleic acid, phosphatidylcholine, choresterol (5 alpha), cumene and tert-butyl and hydrogen peroxide. This chemiluminescence method was simple and sensitive enough to detect picomole levels of linoleic acid and phosphatidylcholine hydroperoxides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号