首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new method was developed and validated for quantitating OSI-774 and its metabolite OSI-420 in human plasma. Sample preparation involved initial extraction with methyl t-butyl ether followed by back extraction with HCl and re-extraction with methyl t-butyl ether. This extraction process resulted in significant improvement in the specificity, reproducibility and sensitivity. The analytes were separated on a Water Symmetry C18 analytical column and the mobile phase consisted of acetonitrile-0.05 M potassium phosphate buffer (42:58, v/v) (pH 4.8), and monitored at a wavelength 345 nm. Values of between- and within-day precision and accuracy for both OSI-774 and OSI-420 were <20%. This method was successfully applied to study steady-state pharmacokinetics of OSI-774 and OSI-420 in a phase II clinical trial.  相似文献   

2.
A high-performance liquid-chromatographic (HPLC) assay with UV detection has been developed for the quantitative determination of erlotinib (OSI-774) in human plasma. Quantitative extraction was achieved by a single-solvent extraction involving a mixture of acetonitrile and n-butyl chloride (1:4, v/v). Erlotinib and the internal standard hydrochloride salt (OSI-597) were separated on a column packed with Nova-Pak C18 material and a mobile phase composed of acetonitrile and water, pH 2.0 (60:40, v/v). The column effluent was monitored with dual UV detection at wavelengths of 348 nm (erlotinib) and 383 nm (OSI-597). The calibration graph was linear in the range of 100-4500 ng/ml, with values for accuracy and precision ranging from 87.9 to 96.2% and 2.13 to 5.10%, respectively, for three different sets of quality control samples. The developed method was successfully applied to study the pharmacokinetics of erlotinib in a cancer patient at the recommended daily dose of 150 mg.  相似文献   

3.
A new simple and specific method was developed and validated for the quantitative determination of OSI-774 (Tarceva, Erlotinib) and its metabolite, OSI-420, in human plasma. Sample pretreatment involved a single protein precipitation step with acetonitrile. The analytes were separated on Waters X-Terra C(18) (50 x 2.1 mm I.D., 3.5 microm) analytical column and eluted with acetonitrile-water mobile (70:30, v/v) containing 0.1% formic acid. The analytes of interest were monitored by tandem mass spectrometry with electrospray positive ionization. The overall extraction efficiency was greater than 88% for OSI-774 and 62% for OSI-420, with values for within-day and between-day precision and accuracy of <15%. Compared to previous assays, this method is simple, specific, and reproducible and will be used to characterize the plasma pharmacokinetics of OSI-774 at doses of 50 to 150 mg to optimize treatment with this agent.  相似文献   

4.
Gefitinib and erlotinib are two oral tyrosine kinase inhibitors (TKI) approved for the treatment of advanced non-small cell lung cancer (NSCLC). Published methods for simultaneous analysis of erlotinib and gefitinib in plasma are exclusively based on mass spectrometry. The purpose of this study was to develop a simple and sensitive HPLC-UV method to simultaneously quantify these two TKI in plasma. Following liquid-liquid extraction, gefitinib, erlotinib and sorafenib (internal standard), were separated with gradient elution (on a C8+ Satisfaction(?) using a mobile phase of acetonitrile/20mM ammonium acetate pH 4.5). Samples were eluted at a flow rate of 0.4 ml/min throughout the 15-min run. Dual UV wavelength mode was used, with gefitinib and erlotinib monitored at 331 nm, and sorafenib at 249 nm. The calibration was linear in the range 20-1000 ng/ml and 80-4000 ng/ml for gefitinib and erlotinib, respectively. Inter- and intra-day imprecision were less than 7.2% and 7.6% for gefitinib and erlotinib, respectively. This analytical method was successfully applied to assess the steady state plasma exposure to these TKI in NSCLC patients. This simple, sensitive, accurate and cost-effective method can be used in routine clinical practice to monitor gefitinib or erlotinib concentrations in plasma from NSCLC patients.  相似文献   

5.
A method was developed for the quantification of matrine in human plasma using a liquid-liquid extraction procedure followed by gas-chromatography-mass spectrometry (GC/MS) analysis. Deuterated matrine, an internal standard of the analysis, was spiked into the plasma samples before extraction. Linear detection responses were obtained for matrine concentrations ranging from 10 to 500 ng/ml. The intra-day and inter-day precision ranged from 0.4 to 4.0% and 1.0-3.5%, respectively. The intra-day accuracy was between -7.3 and 4.5%. The limit of quantification for matrine was 23 ng/ml. The extraction efficiency averaged about 38%. The validated GC/MS method will be used to quantify matrine in human plasma samples collected in a clinical trial study.  相似文献   

6.
A significant percentage of psychiatric patients who are treated with antipsychotics are treated with more than one antipsychotic drug in the clinic. Thus, it is advantageous to use a rapid and reliable assay that is suitable for determination of multiple antipsychotic drugs in plasma in a single run. A simple and sensitive HPLC-UV method was developed and validated for simultaneous quantification of olanzapine, haloperidol, chlorpromazine, ziprasidone, risperidone and its active metabolite 9-hydroxyrisperidone in rat plasma using imipramine as an internal standard (I.S.). The analytes were extracted from rat plasma using a single step liquid-liquid acid solution back extraction technique with wash procedure, which provided the very clear baseline for blank plasma extraction. The compounds were separated on an Agilent Eclipse XDB C8 (150 mm x 4.6 mm i.d., 5 microm) column using a mobile phase of acetonitrile/30 mM ammonium acetate including 0.05% triethylamine (pH 5.86 adjusted with acetic acid) with gradient elution. All of the analytes were monitored using UV detection. The method was validated and the linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries, selectivity and stability were determined. The LLOQ was 2.0 ng/ml and correlation coefficient (R(2)) values for the linear range of 2.0-500.0 ng/ml were 0.998 or greater for all the analytes. The precision and accuracy for intra-day and inter-day were better than 7.44%. The recovery was above 74.8% for all of the analytes. This validated method has been successfully used to quantify the plasma concentration of the analytes for pharmacological and toxicological studies following chronic treatment with antipsychotic drugs in the rat.  相似文献   

7.
A sensitive, rapid liquid chromatographic-electrospray ionization mass spectrometric method for determination of erythromycylamine in human plasma was developed and validated. Erythromycylamine in plasma (0.2 mL) was extracted with ethyl acetate, the organic phase was transferred to another clear 1.5 mL Eppendorf tube and evaporated to dryness under gentle nitrogen stream at 45 degrees C, and the residue was dissolved in 100 microL of mobile phase. The samples were separated using a Thermo Hypersil HyPURITY C18 reversed-phase column (150 mm x 2.1 mm I.D., 5 microm). A mobile phase containing 10 mM of ammonium acetate (pH = 6.4)-acetonitrile-methanol (50:10:40, v/v/v) was used isocratically eluting at a flow rate of 0.2 mL/min. Erythromycylamine and its internal standard (IS), midecamycin, were measured by electrospray ion source in positive selective ion monitoring mode. The method demonstrated that good linearity ranged from 4.5 to 720 ng/mL with r = 0.9997. The limit of quantification for erythromycylamine in plasma was 4.5 ng/mL with good accuracy and precision. The mean extraction recovery of the method was higher than 75.1% and 72.7% for erythromycylamine and IS, respectively. The intra-day and inter-day precision ranged from 5.2% to 6.4% and 5.6-9.3% (relative standard deviation, RSD), respectively. The established method has been successfully applied to a bioequivalence study of two dirithromycin formulations for 18 healthy volunteers.  相似文献   

8.
A simple, sensitive and robust liquid chromatography/electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) method was developed and validated for quantification of chlorpromazine in rat plasma and brain tissue. Chlorpromazine was extracted from rat plasma and brain homogenate using liquid-liquid extraction. The compounds were separated on a Waters Atlantis dC-18 (30 mm x 2.1 mm i.d., 3 microm) column using a mobile phase of acetonitrile/20 mM ammonium formate (pH 4.25 adjusted with formic acid) with gradient elution. Chlorpromazine was detected in positive ion mode using multiple reaction monitoring (MRM). The method was validated and the specificity, linearity, lower limit of quantitation (LLOQ), precision, accuracy, recoveries and stability were determined. The LLOQ was 0.2 ng/ml for plasma and 0.833 ng/g for brain tissue. The method was linear over the concentration range from 0.2 to 200.0 ng/ml for plasma and from 0.833 to 833.3 ng/g for brain tissue. The correlation coefficient (R(2)) values were more than 0.998 for both plasma and brain homogenate. The precision and accuracy for intra-day and inter-day were better than 7.54%. The relative and absolute recovery was above 84.9% and matrix effects were lower than 5.6%. This validated method has been successfully used to quantify the rat plasma and brain tissue concentration of chlorpromazine after chronic treatment.  相似文献   

9.
An analytical method based on liquid chromatography with positive ion electrospray ionization (ESI) coupled to tandem mass spectrometry detection (LC-MS/MS) was developed for the determination of a potent 5-HT(1B/1D) receptor agonist, rizatriptan in human plasma using granisetron as the internal standard. The analyte and internal standard were isolated from 100 microL plasma samples by liquid-liquid extraction (LLE) and chromatographed on a Lichrospher C18 column (4.6mm x 50mm, 5 microm) with a mobile phase consisting of acetonitrile-10mM aqueous ammonium acetate-acetic acid (50:50:0.5, v/v/v) pumped at 1.0 mL/min. The method had a chromatographic total run time of 2 min. A Varian 1200 L electrospray tandem mass spectrometer equipped with an electrospray ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 270-->201 (rizatriptan) and 313.4-->138 (granisetron) used for quantitation. The assay was validated over the concentration range of 0.05-50 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was above 98%. The intra-day accuracy of the assay was within 12% of nominal and intra-day precision was better than 13% C.V. Following a 10mg dose of the compound administered to human subjects, mean concentrations of rizatriptan ranged from 0.2 to 70.6 ng/mL in plasma samples collected up to 24h after dosing. Inter-day accuracy and precision results for quality control samples run over a 5-day period alongside clinical samples showed mean accuracies of within 12% of nominal and precision better than 9.5% C.V.  相似文献   

10.
Nicotine (NIC), cotinine (COT) and trans-3'-hydroxycotinine (OHCOT) are the most prevalent and abundant tobacco biomarkers in meconium. We have developed and validated an accurate and precise method for the measurement of these analytes in meconium in which potassium hydroxide is used to digest the meconium sample, followed by solid phase extraction from the liquified sample. The precision of OHCOT, COT and NIC measurements (intra-day and inter-day) were 4.8-10.6%, 3.4-11.6% and 9.3-15.8%, respectively. Evaluation of accuracy indicated bias of -4.0, 2.0 and 0.8% for OHCOT at concentrations of 0.5, 2.5 and 7.5 ng/g. The accuracy estimates for COT at concentrations of 0.5, 2.5 and 7.5 ng/g are 4.0, 4.0 and 5.7%, respectively. For NIC at 2, 10 and 30 ng/g the accuracy was calculated to be 3.0, 5.0 and 5.1%, respectively. The linear range of standard solutions was 0.125-37.5 ng/mL for OHCOT and COT, and 0.75-150 ng/mL for NIC. This method was applied to the analysis of 374 meconium samples from infants of both smoking and nonsmoking mothers. Positive correlations with r(2)≥0.63 were observed between NIC and COT, COT and OHCOT, NIC and OHCOT, and NIC and (OHCOT+COT) in these samples.  相似文献   

11.
An ultra-violet high-performance liquid chromatographic method was developed for the determination of sertindole, an atypical antipsychotic drug and its main metabolites dehydrosertindole and norsertindole, in human plasma. With a small sample volume, after a single-step liquid-liquid extraction, the compounds were separated on a reversed-phase XTerra RP(18) column, eluted with 45% of acetonitrile and 55% of ammonium acetate buffer (0.05 M, adjusted pH 8) and detected at 256 nm within 11 min. This method shows a good linearity for plasma concentration between 5-100 ng/ml and 100-1000 ng/ml, a good precision (inter and intra day CV < 11%) and a good inter-assay accuracy (bias < 11%). The limit of quantification concentration was 5 ng/ml. The absolute recovery of sertindole was higher than 99%. This rapid and sensitive method could be used for therapeutic drug monitoring as well as for overdose management.  相似文献   

12.
A sensitive method for the determination of CQP propionic acid in rat plasma was developed and validated after solid-phase extraction. Chromatographic separation was achieved on a reversed-phase Alltima C18 column with the mobile phase of methanol-0.15% (v/v) phosphoric acid solution (pH 2.5) and step gradient elution resulted in a total run time of about 20min. The analytes were detected by using UV detector at 345nm. A good linear relationship was obtained in the concentration range of 50-12,800ng/mL (r=0.9998). The intra-day RSDs and the inter-day RSDs at the concentration of 200, 800, 6400 and 12,800ng/mL were less than 7.0% and 11.0%, respectively. The intra-day accuracy ranged from 96.3 to 106.5% and the inter-day accuracy ranged from 98.6 to 113.4%, respectively. Average extraction recoveries ranged from 83.6 to 94.3% in plasma at the concentrations of 200, 800, 6400 and 12,800ng/mL. This method was successfully applied to the pharmacokinetic studies on rats.  相似文献   

13.
An HPLC-MS/MS assay for the determination of an HIV integrase inhibitor, 5-(1,1-dioxido-1,2-thiazinan-2-yl)-N-(4-fluorobenzyl)-8-hydroxy-1,6-naphthyridine-7-carboxamide (I) in human plasma has been developed and validated. Compound I and a stable isotope labeled internal standard (II) were isolated from 0.5 mL plasma samples by solid phase extraction using an Ansys SPEC C-8 96-well plate. Extracts were separated on a Hypersil BDS C-18 HPLC column (3.0 mmx50 mm, 3 microm) with a mobile phase consisting of 25 mM ammonium formate pH 3.0:acetonitrile (60:40) vol%/vol% pumped at 0.5 mL/min. A Sciex API 365 mass spectrometer equipped with an atmospheric pressure chemical ionization source was operated in selected reaction monitoring (SRM) mode with the precursor-to-product ion transitions m/z 431-->109 (I) and m/z 437-->115 (II) used for quantitation. The assay was validated over the concentration range of 10-5000 ng/mL and was found to have acceptable accuracy, precision, linearity, and selectivity. The mean extraction recovery from spiked plasma samples was 69%. The intra-day accuracy of the assay was within 4% of nominal and intra-day precision was better than 4% C.V. Following a 200 mg dose of the compound administered to human subjects, concentrations of I ranged from 21.1 to 1500 ng/mL in plasma samples collected up to 12 h after dosing. Inter-day accuracy and precision results for quality control samples run over a 3-month period alongside clinical samples showed mean accuracies of within 6% of nominal and precision better than 3.5% C.V.  相似文献   

14.
A rapid, sensitive and selective method was developed for the quantitative determination of hederagenin in rat plasma and cerebrospinal fluid (CSF) by ultra fast liquid chromatography-tandem mass spectrometry (UFLC-MS/MS). It has been successfully applied in a pharmacokinetic study of hederagenin in the central nervous system (CNS). Sample pretreatment involved a simple protein precipitation with methanol and a one-step extraction with ethyl acetate. Separation was carried out in a Shim-pack XR-ODS II (75 mm × 2.0 mm, i.d., 2.1 μm) column with gradient elution at a flow rate of 0.35 mL/min. The mobile phase was 5mM ammonium acetate and acetonitrile. Detection was performed in a triple-quadruple tandem mass spectrometer by multiple-reaction-monitoring mode via electrospray ionization. A linear calibration curve for hederagenin was obtained over a concentration range of 0.406 (lower limit of quantification, LLOQ) to 203 ng/mL (r2 > 0.99) for both plasma and CSF. The intra-day and inter-day precision (relative standard deviation, RSD) values were less than 15%. At all quality control (QC) levels, the accuracy (relative error, RE) was within -9.0% and 11.1% for plasma and CSF, respectively. The pharmacokinetics results indicated that hederagenin could pass through the blood-brain barrier. This UFLC-MS/MS method demonstrates higher sensitivity and sample throughput than previous methods. It was also successfully applied to the pharmacokinetic study of hederagenin following oral administration of Fructus akebiae extract in rats.  相似文献   

15.
A rapid and sensitive method using liquid chromatography-tandem mass spectroscopy (LC-MS/MS) was developed and validated for simultaneous quantitative determination of valproic acid and three major metabolites (3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid) in human plasma. The analytes and internal standard were isolated from 200 μL samples by solid phase extraction using a ZORBAX SB-C? column (3.5 μm, 2.1×100 mm) with an isocratic mobile phase consisting of methanol-10mM ammonium acetate (80:20, v/v) containing 0.1% formic acid at a flow rate of 0.3 mL/min. The method had a chromatographic total run time of 2.0 min. The lower limit of quantification of valproic acid, 3-OH-valproic acid, 4-ene-valproic acid and 5-OH-valproic acid of the method was 2030, 51.5, 50.15 and 51.25 ng/mL, respectively. The method was linear for valproic acid and the three metabolites with correlation coefficients >0.995 for all analytes. The intra-day and inter-day accuracy and precision of the assay were less than 15.0%. This analytical method was successfully used to assay plasma concentrations of valproic acid and the three metabolites in human plasma from epileptic patients.  相似文献   

16.
A selective and sensitive high-performance liquid chromatographic assay for a novel cognitive enhancer, X9121 (I), and its mono N-oxide metabolite, XG696 (II), in dog plasma has been developed. Compounds I, II and internal standard (I.S.) were first extracted from dog plasma using a solid-phase Bond Elut Certify I 10-ml LRC reservoir extraction cartridge. Chromatographic separation of I, II and I.S. was conducted on a reversed-phase Zorbax Stable Bond cyano column. Ammonium acetate buffer (0.05 M, pH 6)-acetonitrile-triethylamine (75:25:0.1, v/v) was used as the mobile phase. Detection of all three compounds was by UV light absorbance at 313 nm. Using 0.5 ml of dog plasma for extraction, the minimum quantifiable limit was 10 ng/ml and the assay was linear from 10 to 5400 ng/ml. The coefficients of variation for intra-day precision ranged from 2.2 to 8.5% for I and from 2.5 to 9.8% for II. The coefficients of variation for the inter-day precision for these two compounds ranged from 2.6 to 9.0% and from 3.6 to 16.2%, respectively. The absolute percent differences for the accuracy results were within 11.0% of the spiked concentrations. Compounds I and II were stable in frozen plasma at −20°C for at least 67 days.  相似文献   

17.
A selective and sensitive method for the determination of the HIV protease inhibitor saquinavir in human plasma, saliva, and urine using liquid-liquid extraction and LC-MS-MS has been developed, validated, and applied to samples of a healthy individual. After extraction with ethyl acetate, sample extracts were chromatographed isocratically within 5 min on Kromasil RP-18. The drug was detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source and 2H(5)-saquinavir as internal standard. The limit of quantification was 0.05 ng/mL. The accuracy of the method varied between -1 and +10% (SD within-batch) and the precision ranged from +4 to +10% (SD batch-to-batch). The method is linear at least within 0.05 and 87.6 ng/mL. After a regular oral dose (600 mg) saquinavir concentrations were detectable for 48 h in plasma and were well correlated with saliva concentrations (r(2)=0.9348, mean saliva/plasma ratio 1:15.1). The method is well suited for low saquinavir concentrations in different matrices.  相似文献   

18.
A precise and accurate high-performance liquid chromatography (HPLC) method with photodiode array detection has been developed and validated for raltegravir, a human immunodeficiency virus integrase strand transfer inhibitor (HIV-1 INSTI). Plasma (300 μL) was extracted with dichloromethane/hexane 50:50 (v/v) after addition of the internal standard, 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline. The compounds were separated using a dC18 column and detected with ultraviolet detection at 320 nm. The limit of quantification was 10 ng/mL for raltegravir. The method was linear and validated over a concentration range of 0–10,000 ng/mL. The intra-day precision ranged from 3.1 to 12.3%, while the intra-day accuracy ranged from ?15.0 to ?0.5%, the inter-day precision and accuracy were less than 7%. The mean recovery was 76.8%. Application to clinical samples taken from patients treated with raltegravir indicated that the method is suitable for measuring plasma concentrations of raltegravir in pharmacokinetic studies of clinical trials.  相似文献   

19.
A selective and sensitive method for the simultaneous determination of hypericin and hyperforin--the two main active ingredients of St. John's Wort (SJW) extract--in human plasma depending on liquid/liquid-extraction and LC/MS/MS detection has been developed, validated after specifying the stability of the photosensitive hypericin in plasma samples during light exposure and applied to samples of a patient. After extraction with ethyl acetate/n-hexane in the darkness, sample extracts were chromatographed isocratically within 6 min on a Kromasil RP-18 column. The analytes were detected with tandem mass spectrometry in the selected reaction monitoring mode using an electrospray ion source. The limit of quantification was 0.05 ng/mL for hypericin and 0.035 ng/mL for hyperforin. The accuracy of the method varied between 101.9 and 114.2% and the precision ranged from 4.7 to 15.4% (S.D., batch-to-batch) for both analytes. The method was linear at least between 0.05 and 10 ng/mL for hypericin and between 0.035 and 100 ng/mL for hyperforin. Using this method hypericin and hyperforin were determined successfully in a patient over seven days following discontinuation of exposure with therapeutic doses of St. John's Wort extract.  相似文献   

20.
An analytical method was developed and validated for the quantitative determination of the cyclic depsipeptide FK228 (romidepsin, formerly FR901228; NSC 630176), a histone deacetylase inhibitor, in human and mouse plasma. Calibration curves were linear in the concentration range of 2-1000 ng/mL. Sample pretreatment involved a liquid-liquid extraction of 0.1 mL aliquots of plasma with ethyl acetate. FK228 and the internal standard, harmine, were separated on a Zorbax SB C18 column (75 mm x 2.1mm, 3.5 microm), using a mobile phase composed of methanol and 0.2% formic acid. The column eluent was monitored by mass spectrometry with electrospray ionization. Accuracy and precision of four concentrations of quality control samples ranged from 101.5 to 106.4% and 0.7 to 3.5% in human plasma and 93.6 to 100.6% and 0.6 to 6.5%, in mouse plasma, respectively. This method represents a significant improvement over our previously published analytical assay for this agent, decreasing the sample volume requirements, increasing the accuracy and precision (through addition of a suitable internal standard), expanding the analytical range and validating in additional biological matrices. The developed method was applied to study the pharmacokinetics of FK228 in over 1000 clinical and preclinical samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号