首页 | 本学科首页   官方微博 | 高级检索  
   检索      


Infrared heater arrays for warming ecosystem field plots
Authors:BRUCE A KIMBALL  MATTHEW M CONLEY  SHIPING WANG†  XINGWU LIN†  CAIYUN LUO†  JACK MORGAN‡  DAVID SMITH‡
Institution:US Arid Land Agricultural Research Center, USDA, Agricultural Research Service, 21881 North Cardon Lane, Maricopa, AZ 85238, USA,;Key Laboratory of Adaptation and Evolution of Plateau Biota, Northwest Institute of Plateau Biology, Chinese Academy of Sciences, Xining 810008, Qinghai, China,;Crops Research Laboratory, USDA, Agricultural Research Service, Ft Collins, CO 80526, USA
Abstract:There is a need for methodology to warm open‐field plots in order to study the likely effects of global warming on ecosystems in the future. Herein, we describe the development of arrays of more powerful and efficient infrared heaters with ceramic heating elements. By tilting the heaters at 45° from horizontal and combining six of them in a hexagonal array, good uniformity of warming was achieved across 3‐m‐diameter plots. Moreover, there do not appear to be obstacles (other than financial) to scaling to larger plots. The efficiency ηh (%); thermal radiation out per electrical energy in] of these heaters was higher than that of the heaters used in most previous infrared heater experiments and can be described by: ηh= 10 + 25exp(? 0.17 u), where u is wind speed at 2 m height (m s? 1). Graphs are presented to estimate operating costs from degrees of warming, two types of plant canopy, and site windiness. Four such arrays were deployed over plots of grass at Haibei, Qinghai, China and another at Cheyenne, Wyoming, USA, along with corresponding reference plots with dummy heaters. Proportional integral derivative systems with infrared thermometers to sense canopy temperatures of the heated and reference plots were used to control the heater outputs. Over month‐long periods at both sites, about 75% of canopy temperature observations were within 0.5 °C of the set‐point temperature differences between heated and reference plots. Electrical power consumption per 3‐m‐diameter plot averaged 58 and 80 kW h day? 1 for Haibei and Cheyenne, respectively. However, the desired temperature differences were set lower at Haibei (1.2 °C daytime, 1.7 °C night) than Cheyenne (1.5 °C daytime, 3.0 °C night), and Cheyenne is a windier site. Thus, we conclude that these hexagonal arrays of ceramic infrared heaters can be a successful temperature free‐air‐controlled enhancement (T‐FACE) system for warming ecosystem field plots.
Keywords:canopy temperature  climate change  ecosystems  GIS  global change  global warming  infrared heater  rangeland  thermal radiation  wind speed
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号