首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   26篇
  免费   0篇
  2023年   1篇
  2019年   1篇
  2018年   1篇
  2017年   3篇
  2015年   3篇
  2014年   3篇
  2013年   7篇
  2010年   1篇
  2008年   2篇
  2007年   1篇
  2005年   2篇
  2001年   1篇
排序方式: 共有26条查询结果,搜索用时 15 毫秒
1.
This work is concerned with the lubrication analysis of artificial knee joints, which plays an increasing significant role in clinical performance and longevity of components. Time-dependent elastohydrodynamic lubrication analysis for normal total knee replacement is carried out under the cyclic variation in both load and speed representative of normal walking. An equivalent ellipsoid-on-plane model is adopted to represent an actual artificial knee. A full numerical method is developed to simultaneously solve the Reynolds and elasticity equations using the multigrid technique. The elastic deformation is based on the constrained column model. Results show that, under the combined effect of entraining and squeeze-film actions throughout the walking cycle, the predicted central film thickness tends to decrease in the stance phase but keeps a relatively larger value at the swing phase. Furthermore, the geometry of knee joint implant is verified to play an important role under its lubrication condition, and the length of time period is a key point to influence the lubrication performance of joint components.  相似文献   
2.
Titanium alloy is one of the best materials for biomedical applications due to its superior biocompatibility, outstanding corrosion resistance, and low elastic modulus. However, the friction and wear behaviors of titanium alloys were sensitive to the environment including lubrication. In order to clarify the wear mechanism of titanium alloy under different lubrications including deionized water, physiological saline and bovine serum, the friction and wear tests were performed between Ti6Al4V plates and Si3N4 ball on a universal multi-functional tester. The friction and the wear rate of titanium alloy were measured under dry friction and three different lubrication conditions. The worn surfaces were examined by scanning electron microscopy. The results revealed that under the dry friction, the wear resistance of titanium alloy was the worst since the wear mechanism was mainly the combination of abrasive wear and oxidation wear. It was also found that Ti6Al4V alloy had low friction coefficient and wear rate under three lubrication conditions, and its wear mechanism was adhesive wear.  相似文献   
3.
Cooling and lubrication agents like triethanolamine (TEA) are essential for many purposes in industry. Due to biodegradation, they need continuous replacement, and byproducts of degradation may be toxic. This study investigates an industrial (1,200 m³) cooling-lubrication circuit (CLC) that has been in operation for 20 years and is supposedly in an ecological equilibrium, thus offering a unique habitat. Next-generation (Illumina Miseq 16S rRNA amplicon) sequencing was used to profile the CLC-based microbiota and relate it to TEA and bicine dynamics at the sampling sites, influent, machine rooms, biofilms and effluent. Pseudomonas pseudoalcaligenes dominated the effluent and influent sites, while Alcaligenes faecalis dominated biofilms, and both species were identified as the major TEA degrading bacteria. It was shown that a 15 min heat treatment at 50°C was able to slow down the growth of both species, a promising option to control TEA degradation at large scale.  相似文献   
4.
Hydrogel has been extensively studied as an articular cartilage repair and replacement material. PVA-HA-Silk composite hydrogel was prepared by freezing-thawing method in this paper. Mechanical properties were determined by experiments and the friction coefficient of PVA-HA-Silk composite hydrogel against steel ball was verified using micro-tribometer. Finite Element Method (FEM) was used to study the lubrication mechanism of PVA-HA-Silk composite hydrogel and the relation between the interstitial fluid load support and the start-up friction resistance. The results show that the elastic modulus and the permeability are 2.07 MPa and 10^-15m^4N^-1s^-1, respectively, and the start-up friction coefficients of PVA-HA-Silk composite hydrogel are in the range of 0.154).2 at different contact loads, contact time and sliding speeds. The start-up friction resistance of PVA-HA-Silk composite hydrogel increases with the contact load and contact time. With the increase in sliding speed, the start-up friction resistance of PVA-HA-Silk composite hydrogel decreases. There is an inverse relation between the start-up friction resistance and the interstitial fluid load support. The change of fluid flow with the increase in sliding displacement has an important effect on the interstitial fluid load support and friction resistance. The interstitial fluid load support decreases with the increase in contact load and contact time, while the interstitial fluid load support reinforces with the increase in sliding speed. Moreover, PVA-HA-Silk composite hydrogel has mechanical properties of recovery and self-lubricating.  相似文献   
5.
Self-lubrication of a diarthrodial joint is largely attributed to interstitial fluid pressurisation. However, the retention of synovial fluid within the intra-articular gap may also contribute to lubrication. Fluid flow in the intra-articular gap between two micro-rough cartilage surfaces was simulated with a three-dimensional numerical model. Representative surface roughness parameters were incorporated and their relative influence on gap flow resistance was quantified. Resistance changes with decreasing gap height were explored. Cartilage surface micro-topography improves the retention of viscous synovial fluid in the gap, through increased resistance to tangential flow. Local asperity contact greatly increases resistance through tortuosity of the flow path.  相似文献   
6.
The objective of this study was to understand the behavior of particulate systems under different conditions of shear dynamics before and after granulation and to investigate the efficiency of powder lubrication. Three drug powders, metronidazole, colloidal bismuth citrate, and tetracycline hydrochloride, were chosen as model drugs representing noncohesive and cohesive powder systems. Each powder was individually granulated with microcrystalline cellulose and 5%PVP as a binder. One portion from each granulation was lubricated with different levels of magnesium stearate for 5 minutes. The powder characterization was performed on the plain powders, nonlubricated and lubricated granules using powder rheometer equipped with a helical blade rotating and moving under experimentally fixed set of parameters. The profiles of interaction during the forcedistance measurements indicate that powder compresses, expands, and shears many times in a test cycle. Test profiles also clearly reveal existence of significant differences between cohesive and noncohesive powders. In all cases lubrication normalized the overall interactive nature of the powder by reducing peaks and valleys as observed from the profiles and reduced the frictional effect. The developed methods are easy to perform and will allow formulation scientists to better understand powder behavior and help in predicting potential impact of processing factors on particulate systems. Published: October 19, 2005  相似文献   
7.
For nearly a century, articular cartilage has been known for its exceptional tribological properties. For nearly as long, there have been research efforts to elucidate the responsible mechanisms for application toward biomimetic bearing applications. It is now widely accepted that interstitial fluid pressurization is the primary mechanism responsible for the unusual lubrication and load bearing properties of cartilage. Although the biomechanics community has developed elegant mathematical theories describing the coupling of solid and fluid (biphasic) mechanics and its role in interstitial lubrication, quantitative gaps in our understanding of cartilage tribology have inhibited our ability to predict how tribological conditions and material properties impact tissue function. This paper presents an analytical model of the interstitial lubrication of biphasic materials under migrating contact conditions. Although finite element and other numerical models of cartilage mechanics exist, they typically neglect the important role of the collagen network and are limited to a specific set of input conditions, which limits general applicability. The simplified approach taken in this work aims to capture the broader underlying physics as a starting point for further model development. In agreement with existing literature, the model indicates that a large Peclet number, Pe, is necessary for effective interstitial lubrication. It also predicts that the tensile modulus must be large relative to the compressive modulus. This explains why hydrogels and other biphasic materials do not provide significant interstitial pressure under high Pe conditions. The model quantitatively agrees with in-situ measurements of interstitial load support and the results have interesting implications for tissue engineering and osteoarthritis problems. This paper suggests that a low tensile modulus (from chondromalacia or local collagen rupture after impact, for example) may disrupt interstitial pressurization, increase shear stresses, and activate a condition of progressive surface damage as a potential precursor of osteoarthritis.  相似文献   
8.
Carbon Fiber (CF) reinforced polyetheretherketone (PEEK) composite is one of the most promising implant biomaterials used in orthopedics.In this article,unfilled PEEK and CF/PEEK specimens were prepared by vacuum hot pressing method,and their tribological properties were evaluated by sliding against a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy block.The influences of mass fraction of carbon fibers in CF/PEEK and the surface oxidation treatment of carbon fibers were explored.The results showed that the water contact angles on the surfaces of CF/PEEK specimens decreased,indicating that their surface wettability was improved.The hardness value of CF/PEEK was significantly improved,the friction coefficients of CF/PEEK were effectively reduced and its wear resistance was enhanced compared with unfilled PEEK.The leading effect on CF/PEEK tribological properties was the mass fraction of CF,followed by surface oxidation of CF,and the calf serum solution had better lubricity than that of saline and deionized water.  相似文献   
9.
One of the major constituents of the synovial fluid that is thought to be responsible for chondroprotection and boundary lubrication is the glycoprotein lubricin (PRG4); however, the molecular mechanisms by which lubricin carries out its critical functions still remain largely unknown. We hypothesized that the interaction of lubricin with type II collagen, the main component of the cartilage extracellular matrix, results in enhanced tribological and wear properties. In this study, we examined: (i) the molecular details by which lubricin interacts with type II collagen and how binding is related to boundary lubrication and adhesive interactions; and (ii) whether collagen structure can affect lubricin adsorption and its chondroprotective properties. We found that lubricin adsorbs strongly onto denatured, amorphous, and fibrillar collagen surfaces. Furthermore, we found large repulsive interactions between the collagen surfaces in presence of lubricin, which increased with increasing lubricin concentration. Lubricin attenuated the large friction and also the long-range adhesion between fibrillar collagen surfaces. Interestingly, lubricin adsorbed onto and mediated the frictional response between the denatured and native amorphous collagen surfaces equally and showed no preference on the supramolecular architecture of collagen. However, the coefficient of friction was lowest on fibrillar collagen in the presence of lubricin. We speculate that an important role of lubricin in mediating interactions at the cartilage surface is to attach to the cartilage surface and provide a protective coating that maintains the contacting surfaces in a sterically repulsive state.  相似文献   
10.
The role of saliva in the oral cavity is manifold; an important function is to serve as lubricant between hard (enamel) and soft (mucosal) tissues. Intraoral lubrication is of crucial importance in order to maintain functions such as deglutition, mastication and the faculty of speech. A large number of people suffer from impaired salivary functions, displaying symptoms such as ‘dry mouth’. This results in a need for methods to assess the lubricating properties of both native saliva and potential artificial saliva formulations. Here, normal as well as lateral forces, acting between adsorbed salivary films, have been measured for the first time by means of colloidal probe atomic force microscopy (AFM). It was found that the presence of salivary pellicles between hard surfaces reduces the friction coefficient by a factor of 20. This reduction of friction is consistent with the long-range purely repulsive nature of the normal forces acting between the salivary films. The lubricating mechanism is presumably based on a full separation of the sliding surfaces by the salivary films. The friction between salivary films has been investigated at normal loads that cover the clinical jaw closing forces, and it can be concluded that the lubricating properties are maintained within this load interval. The present study indicates the usefulness of colloidal probe AFM, which offers a direct and quantitative measure of lubrication at a molecular level, in the study of biotribological phenomena. In particular, the results obtained here may have implications for the development of saliva substitutes.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号