首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   131篇
  免费   2篇
  2023年   8篇
  2022年   1篇
  2021年   7篇
  2020年   4篇
  2019年   6篇
  2018年   15篇
  2017年   11篇
  2016年   2篇
  2015年   1篇
  2014年   15篇
  2013年   25篇
  2012年   9篇
  2011年   8篇
  2009年   7篇
  2008年   1篇
  2007年   4篇
  2006年   1篇
  2003年   4篇
  1999年   2篇
  1998年   1篇
  1992年   1篇
排序方式: 共有133条查询结果,搜索用时 15 毫秒
1.
Single photon emission computed tomography of the brain can be useful in animal experimentation directed toward cerebral conditions. A well established and understood baboon model, necessarily under anesthesia, could be especially valuable in such investigations. Six normal baboons were studied under various anesthetic agents and their combinations: ketamine, thiopentone, pentobarbitone, and halothane. Cerebral blood flow (CBF) studies were performed with 99mTc-HMPAO. CBF effects from various anesthesia were detected, requiring careful choice of the anesthesia for cerebral investigations.  相似文献   
2.
In vivo imaging of voltage-gated sodium channels (VGSCs) can potentially provide insights into the activation of neuronal pathways and aid the diagnosis of a number of neurological diseases. The iminodihydroquinoline WIN17317-3 is one of the most potent sodium channel blockers reported to date and binds with high affinity to VGSCs throughout the rat brain. We have synthesized a 125I-labeled analogue of WIN17317-3 and evaluated the potential of the tracer for imaging of VGSCs with SPECT. Automated patch clamp studies with CHO cells expressing the Nav1.2 isoform and displacement studies with [3H]BTX yielded comparable results for the non-radioactive iodinated iminodihydroquinoline and WIN17317-3. However, the 125I-labeled tracer was rapidly metabolized in vivo, and suffered from low brain uptake and high accumulation of radioactivity in the intestines. The results suggest that iminodihydroquinolines are poorly suited for tracer development.  相似文献   
3.
Coronary artery disease (CAD) is a major cause of death in Canada and the United States. Single photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a useful diagnostic test in the management of patients with CAD. The widely used SPECT MPI agents, 99mTc sestamibi and 99mTc tetrofosmin, exhibit less than ideal pharmacokinetic properties with decreasing uptake with higher flows. 123I has a similar energy as 99mTc, an ideal half life, and is readily available from cyclotrons. The objective of this study was to develop an 123I labeled MPI agent based on rotenone, a mitochondrial complex I inhibitor, as an alternative to currently available SPECT MPI agents. Methods: 123I-CMICE-013 was synthesized by radiolabeling rotenone with 123I in trifluoroacetic acid (TFA) with iodogen as the oxidizing agent at 60 °C for 45 min, followed by RP-HPLC purification. The product was formulated in 5% EtOH in 10 mM NaOAc pH 6.5. The inactive analog 127I-CMICE-013 was isolated and characterized by NMR and mass spectrometry, and the structure determined. Micro-SPECT imaging studies were carried out in normal and infarcted rats. Biodistribution studies were performed in normal rats at 2 h (n = 6) and 24 h (n = 8) post injection (p.i.). Results: 123I-CMICE-013 was isolated with >95% radiochemical purity and high specific activity (14.8–111 GBq/μmol; 400–3000 mCi/μmol). Structural analysis showed that rotenone was iodinated at 7′-position, with removal of the 6′,7′-double bond, and addition of a hydroxy group at 6′-position. MicroSPECT images in normal rats demonstrated homogeneous and sustained myocardial uptake with minimal interference from lung and liver. Absent myocardial perfusion was clearly identified in rats with permanent left coronary artery ligation and ischemia-reperfusion injury. In vivo biodistribution studies in normal rats at 2 h p.i. showed significant myocardial uptake (2.01 ± 0.48%ID/g) and high heart to liver (2.98 ± 0.93), heart to lung (4.11 ± 1.04) and heart to blood (8.37 ± 3.97) ratios. At 24 h p.i., the majority of 123I-CMICE-013 was cleared from tissues, and a significant amount of tracer was found in the thyroid, indicating in vivo deiodination of the tracer. Conclusion: 123I-CMICE-013 is a promising new radiotracer for SPECT MPI with high myocardial uptake, very good target to background ratios and favorable biodistribution characteristics.  相似文献   
4.
The presence of a parathyroid gland in ectopic position constitutes one of the leading causes of surgery failure. For this purpose, scintigraphy takes a major place in the anatomical localization of pathological parathyroid and so facilitates its treatment. The advent of hybrid cameras combining single photon emission tomography to CT (SPECT/CT) has further strengthened the contribution of this imaging modality in the precise localization of ectopic parathyroid and its anatomical relationships. The objective of our work is to illustrate the interest of hybrid imaging SPECT/CT, compared to planar scintigraphy and ultrasounds within the framework of primary hyperparathyroidism, particularly ectopic situation through three cases.  相似文献   
5.
The sentinel lymph node procedure is still under evaluation for the management of cervical and endometrial carcinomas. The aim of our study was to determine the diagnostic accuracy of single-photon emission computed tomography/computed tomography (SPECT/CT) for preoperative sentinel lymph node mapping in uterine cancers. Sixty-eight patients with cervical (n = 42) or endometrial carcinoma (n = 26) underwent preoperative lymphoscintigraphy for sentinel node mapping. Sentinel node detection rate with conventional planar imaging was similar to that of SPECT/CT (87.1 versus 91.8 %) in the whole cohort. However, SPECT/CT detected a higher number of sentinel nodes in more than one third of patients, affected by either cervical or endometrial carcinoma. The rate of non or insufficiently contributive procedures (lack of uptake or unilateral uptake) in endometrial carcinomas was 47 % with conventional planar imaging, and 30 % with SPECT/CT. Sensitivity of both procedures for the detection of metastatic nodes was 81.8 %, compared to 100 % for the intraoperative combined detection (gamma probe sonde and blue dye). The impact of SPECT/CT for the sentinel lymph node detection in cervical and endometrial carcinomas needs further evaluation. Nevertheless, SPECT/CT may provide additional information when conventional planar imaging detects only unilateral uptake, may improve identification of atypical localizations, and facilitate surgical approach.  相似文献   
6.
Gastric duplications (GD) are rare congenital digestive malformations of the child. Their diagnosis often involves multiple medical imaging modalities ranging from ultrasound to CT or MRI. Scintigraphy is an excellent diagnostic method rarely used especially when the discovery mode of GD is not associated with gastro-intestinal bleeding. We report a case of a non-communicating and non-hemorrhagic GD discovered in a 6-year-old girl whose exploration has benefited many ways including SPECT imaging after intravenous injection of Tc-99 m pertechnetate. Our goal is to focus on the role of scintigraphy in the diagnostic management of the DG of the child and to discuss the opportunity of the other imaging techniques in the exploration of this pathology.  相似文献   
7.
The α7-nicotinic acetylcholine receptor (α7-nAChR) subtype, is found to have a connection with the pathogenesis of a variety of psychiatric and neurological disorders. Herein, we report the development of radioiodinated 9-fluorenone derivatives as single-photon emission computed tomography (SPECT) imaging tracers for α7-nAChRs. Among the derivatives, the best member of the series 10 (Ki = 2.23 nM) were radiolabeled with 125I for in vitro and in vivo studies. The radiotracer [125I]10 exhibited robust brain uptake and specifically labeled α7-nAChRs with a peak uptake value of 9.49 ± 0.87%ID/g in brain. Blocking studies demonstrated that the tracer was highly specific toward α7-nAChR. Furthermore, ex vivo autoradiography and micro-SPECT/CT dynamic imaging in mice confirmed the excellent imaging properties. In addition, molecular docking was also performed to rationalize the potency of the chosen compounds towards α7-nAChRs. To conclude, compound 10 could serve as a promising radiotracer for the α7-nAChRs.  相似文献   
8.
Non-invasive longitudinal detection and evaluation of gene expression in living animals can provide investigators with an understanding of the ontogeny of a gene's biological function(s). Currently, mouse model systems are used to optimize magnetic resonance imaging (MRI), positron emission tomography (PET), single-photon emission computed tomography (SPECT), and optical imaging modalities to detect gene expression and protein function. These molecular imaging strategies are being developed to assess tumor growth and the tumor microenvironment. In addition, pre-labeling of progenitor cells can provide invaluable information about the developmental lineage of stem cells both in organogenesis and tumorigenesis. The feasibility of this approach has been extensively tested by targeting of endogenous tumor cell receptors with labeled ligand (or ligand analog) reporters and targeting enzymes with labeled substrate (or substrate analog). We will primarily discuss MRI, PET, and SPECT imaging of cell surface receptors and the feasibility of non-invasive imaging of gene expression using the tumor microenvironment (e.g., hypoxia) as a conditional regulator of gene expression.  相似文献   
9.

Background and Aim

Primary percutaneous coronary intervention (PCI) is the preferred treatment option for acute myocardial infarction (MI). Off-site PCI reduces time-to-treatment, which could potentially lead to enhanced clinical outcomes. Therefore, we investigated whether off-site PCI improves 5-year clinical outcomes compared with on-site PCI and whether this is related to in-hospital 99mTc-sestamibi single photon emission computed tomography (MIBI SPECT) parameters.

Methods

We describe the 5-year follow-up for a combined endpoint of death or re-infarction in 128 patients with acute MI who were randomly assigned to undergo primary PCI at the off-site centre (n = 68) or to transferral to an on-site centre (n = 60). Three days after PCI, MIBI SPECT was performed to estimate infarct size. A multivariate Cox regression model was created to study the relation between MIBI SPECT parameters and long-term clinical outcomes.

Results

After a mean follow-up of 5.8 ± 1.1 years, 25 events occurred. Off-site PCI significantly reduced door-to-balloon time compared with on-site PCI (94 ± 54 versus 125 ± 59 min, p = 0.003). However, infarct size (17 ± 15 versus 14 ± 12%, p = 0.34) and 5-year death or infarct rate (21% versus 18%, p = 0.75) were comparable between treatment centres. With multivariate analysis, only Killip class ≥2 and Q wave MI, but not scintigraphic data, predicted long-term clinical outcomes.

Conclusion

Off-site PCI reduced door-to-balloon time with a comparable 5-year death or infarct rate. Parameters from resting MIBI SPECT on day 3 after MI did not predict long-term clinical outcomes.  相似文献   
10.
Erythropoietin (EPO) was shown to have protective effects after myocardial infarction (MI) by neovascularization and antiapoptotic mechanisms. Beside direct receptor-dependent mechanisms, mobilization and homing of bone marrow-derived cells (BMCs) may play a pivotal role in this regard. In this study, we intended to track different subpopulations of BMCs and to assess serially myocardial perfusion changes in EPO-treated mice after MI. To allow tracking of BMCs, we used a chimeric mouse model. Therefore, mice (C57BL/6J) were sublethally irradiated, and bone marrow (BM) from green fluorescent protein transgenic mice was transplanted. Ten weeks later coronary artery ligation was performed to induce MI. EPO was injected for 3 days with a total dose of 5000 IU/kg. Subpopulations (CD31, c-kit, CXCR-4 and Sca-1) of EGFP(+) cells were studied in peripheral blood, bone marrow and hearts by flow cytometry. Myocardial perfusion was serially investigated in vivo by pinhole single-photon emission computed tomography (SPECT) at days 6 and 30 after MI. EPO-treated animals revealed an enhanced mobilization of BMCs into peripheral blood. The numbers of these cells in BM remained unchanged. Homing of all BMCs subpopulations to the ischaemic myocardium was significantly increased in EPO-treated mice. Among the investigated subpopulations, EPO predominantly affected migration of CXCR-4(+) (4.3-fold increase). Repetitively SPECT analyses revealed a reduction of perfusion defects after EPO treatment over time. Our study shows that EPO treatment after MI enhances the migration capacity of BMCs into ischaemic tissue, which may attribute to an improved perfusion and reduced size of infarction, respectively.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号