首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   14篇
  免费   4篇
  2021年   1篇
  2019年   4篇
  2017年   1篇
  2015年   1篇
  2014年   4篇
  2013年   1篇
  2012年   1篇
  2007年   2篇
  2006年   1篇
  2001年   1篇
  2000年   1篇
排序方式: 共有18条查询结果,搜索用时 15 毫秒
11.
目的:观察髋关节置换治疗老年股骨颈骨骨折的效果。方法:对60岁以上老年股骨颈骨折23例施行人工股骨头或全髋关节置换术。结果:经平均2.5年随访,总满意率95.7%。结论:人工股骨头或全髋关节置换术是治疗老年人股骨颈骨折的有效方法,可促使老年人早期活动,提高生活质量。  相似文献   
12.
Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2 kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.  相似文献   
13.
Periprosthetic joint infections present a challenging problem in orthopaedics. Conventional methods for detection of arthroplasty infections rely on bacterial culture of synovial fluid aspirates. During recent years, however, molecular tests that are based on DNA amplification by the polymerase chain reaction (PCR), followed by electrophoretic analysis of the products, have been introduced. We report a simple and inexpensive assay that allows visual detection and confirmation of the PCR-amplified sequences by hybridization within minutes. The assay is performed in a dry reagent dipstick format (strip) and does not require special instrumentation. Universal primers are used for PCR of the 23S ribosomal RNA (rRNA) gene. The biotinylated amplification product is hybridized with dA-tailed probes that are specific for six pathogens commonly involved in periprosthetic joint infections. The mixture is applied to the strip, which is then immersed in the appropriate buffer. The buffer migrates along the strip by capillary action and rehydrates gold nanoparticles with oligo(dT) strands attached to their surface. The nanoparticles bind to the target DNA through hybridization, and the hybrids are captured by immobilized streptavidin at the test zone of the strip, producing a characteristic red line. Unbound nanoparticles are captured by immobilized oligo(dT) strands at the control zone of the strip, generating a second line. The dipstick test was applied to the detection of Escherichia coli, Staphylococcus aureus, Staphylococcus epidermidis, Streptococcus pneumoniae, Enterococcus faesium, and Haemophilus influenza. Twelve samples of synovial fluids from patients were analyzed for the detection and identification of the infection caused by the six pathogens. The results were compared with bacterial cultures.  相似文献   
14.
Infection of an orthopedic implant is considered a devastating complication, necessitating its complete removal and thorough debridement of the site. Osseous defects are common in such conditions and need to be addressed before a new implant may be inserted. So far bone grafting has been contraindicated in bacterially contaminated areas and could only be performed as soon as all signs of infection have ceased. Usually long term antibiotic treatment and a multitude of surgical interventions within a period of several months is required until a definitive supply can be achieved. Allograft bone may be impregnated with high loads of antibiotics using special incubation techniques. Based on this technology 48 exchange procedures of infected orthopaedic implants were performed in a single stage, all of them without the use of bone cement. There were 37 infected hips, 8 knees and 3 infected osteosyntheses. Two hips required re-revision because of persisting infection, the remaining 46 patients stayed infect free for a period between 1 and 7 years after surgery. No adverse side effects could be found. Incorporation appeared as after grafting with unimpregnated bone grafts. Antibiotic loaded allograft bone is a powerful tool in septic revision surgery, enabling restoration of bone stock, insertion of a new implant and control of infection in a single operation.  相似文献   
15.
Failures of orthopaedic procedures that use morselized cancellous bone (MCB) graft for load bearing are often due to gross displacement within the graft material. For this reason the mechanical behavior of MCB must be better understood. Our purpose is to present a detailed testing methodology for the mechanical characterization of MCB, and to illustrate how this methodology can be used to study the influence of water and fat content. Complete one-dimensional consolidation testing was performed on bovine cancellous bone processed to represent MCB typically used in surgery (52% water, 31% fat). The one-dimensional consolidation strain under a stress of 1.09 MPa was 30.9% and the confined modulus was 8.0 MPa. The coefficient of consolidation (rate of consolidation) was 2.2×10−5 cm2/s and the coefficient of secondary strain (steady-state creep rate) was 1.9%. While reducing the water content alone had some influence on properties, reducing the fat content improved both the static and dynamic behavior. A sample of MCB which had fat intentionally minimized and a lower overall moisture content (56% water, 5% fat) demonstrated 23.1% strain, a confined modulus of 9.6 MPa, a coefficient of consolidation of 3.4×10−3 cm2/s, and a coefficient of secondary strain of 0.9%. The test methods described in this technical note can be used to evaluate the influence of fluid content on the mechanical behavior of MCB.  相似文献   
16.
目的:观察钛颗粒对小鼠颅骨中OPG/RANKL mRNA及其蛋白表达的影响,探讨关节置换术后骨溶解的发生机制。方法:取成年BALB/C小鼠40只,随机分为假手术组、钛颗粒低剂量组、钛颗粒中剂量组及高剂量组,每组10只。除假手术组外,其余各组分别将钛颗粒15、30、60 mg涂抹于小鼠颅骨表面后缝合切口。8周后取颅骨组织及外周血,运用real-time PCR及ELISA技术测定OPG/RANKL基因及蛋白表达情况。结果:与假手术组相比,钛颗粒低剂量组外周血中OPG蛋白表达及颅骨组织中OPG mRNA的表达均显著上升(P0.01),外周血中RANKL蛋白表达降低,但无统计学差异,颅骨组织中RANKL mRNA表达无显著差异;中剂量组及高剂量组外周血中OPG蛋白表达显著降低(p0.01),RANKL蛋白表达显著升高(P0.01),OPG mRNA表达显著降低(P0.01),RANKL mRNA表达显著升高(P0.01)。低中高三种不同剂量钛颗粒组组间相比,外周血中OPG、RAKNL蛋白及颅骨组织中其mRNA表达均存在明显差异(P0.01),高剂量组对OPG、RANKL蛋白及mRNA表达的影响更显著。结论:钛颗粒可以改变OPG/RANKL的mRNA及蛋白表达量,这可能是其导致关节置换术后体骨溶解进而产生松动的原因之一。  相似文献   
17.
Objectives:To evaluate three different analgesic techniques, continuous epidural analgesia (EA), continuous intra-articular (IA) infusion analgesia and continuous femoral nerve block (FNB) in postoperative pain management, length of hospital stay (LOS), and time of patient mobilization after total knee arthroplasty (TKA).Methods:Seventy-two patients undergoing TKA were randomly allocated into three groups according to the analgesic technique used for postoperative pain management. Group EA patients received epidural analgesia (control group), group IA received intra-articular infusion and group FNB received femoral nerve block.Results:Upon analyzing the Numerical Rating Scale (NRS) scores at rest, at passive and active movement, up to 3 days postoperatively, we observed no statistically significant differences at any time point among the three groups. Similarly, no association among these analgesic techniques (EA, IA, FNB) was revealed regarding LOS. However, significant differences emerged concerning the time of mobilization. Patients who received IA achieved earlier mobilization compared to FNB and EA.Conclusions:Both IA and FNB generate similar analgesic effect with EA for postoperative pain management after TKA. However, IA appears to be significantly more effective in early mobilization compared to EA and FNB. Finally, no clinically important differences could be detected regarding LOS among the techniques studied.  相似文献   
18.
Ankle osteoarthritis is a debilitating condition affecting about 1% of the population with approximately 50,000 new instances annually. One treatment is total ankle arthroplasty (TAA), however, its effects on balance are not well understood. This study analyzed balance over a two-year period following TAA. 408 subjects (177 left, 231 right ankles) diagnosed with end-stage ankle osteoarthritis performed quiet standing trials while center of pressure (COP) data were collected. Data were compared across three time points (pre-op, 1-year, and 2-years post-op) and between surgical and non-surgical limbs using a linear mixed model with significance set at P = 0.05. COP excursions in the feet-together condition were not significantly different between limbs after 2 years in anteroposterior or mediolateral directions (P = 0.06, 0.08) after being significantly different between limbs in the anteroposterior (P = 0.014) and mediolateral direction (P < 0.001) pre-op. The vertical ground reaction force significantly decreased across time in the non-surgical limb, while reciprocally increasing in the surgical limb (P < 0.001). After 2 years, no significant difference in vertical ground reaction force between limbs existed (P = 0.20). Limb asymmetry indices decreased at each time point in both conditions (all P < 0.001) and were not significantly different from zero after 2 years in the feet-together condition (P = 0.290). In conclusion, surgical limb balance improved compared to pre-op, resulting in increased symmetry between limbs after 2 years. Vertical ground reaction forces on both limbs converge and limb asymmetry indices approach zero two years post-op. Differences in the COP excursion-loading symmetry relationship between limbs could be useful for identifying instability in other pathologies.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号