首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The analysis of trace elements in biological samples will extend our understanding of the impact that environmental exposure to these elements has on human health. Measuring arsenic content in nails has proven useful in studies evaluating the chronic body burden of arsenic. In this study, we developed methodology with inductively coupled plasma-mass spectrometry (ICP-MS) for the determination of total arsenic in nails. We assessed the utility of the washing procedures for removing surface contamination. Four types of preanalysis treatments (water bath, sonication, water bath plus sonication, and control) after sample decomposition by nitric acid were compared to evaluate the digestion efficiencies. In addition, we studied the stability of the solution over 1 wk and the effect of acidity on the arsenic signal. Arsenic content in the digested solution was analyzed by using Ar-N2 plasma with Te as the internal standard. The results suggest that washing once with 1% Triton Χ-100 for 20 min for cleaning nail samples prior to ICP-MS analysis is satisfactory. Repeated measurement analysis of variance revealed that there was no significant difference among the various sample preparation techniques. Moreover, the measurements were reproducible within 1 wk, and acidity seemed to have no substantial influence on the arsenic signal. A limit of detection (on the basis of three times the standard deviation of the blank measurement) of 7 ng As/g toenail was achieved with this system, and arsenic recoveries from reference materials (human hair and nails) were in good agreement (95–106% recovery) with the certified/reference values of the standard reference materials. ICP-MS offers high accuracy and precision, as well as highthroughput capacity in the analysis of total arsenic in nail samples.  相似文献   

2.
Selenium belongs to a group of trace elements of special interest in biological samples for clinical diagnosis. Selenium has antioxidizing functions and is essential for providing the organism with triiodothyronine produced from thyroxine. Among several analytical techniques used to determine the Se concentration in serum, Inductively Coupled Plasma Mass Spectrometry (ICP-MS) has been used in the past because of its high sensitivity. Interference problems originating from different ions on the major Se isotopes have been described to be a limiting factor for the direct determination of Se in these matrices. Standard addition calibration or isotope dilution is often required to overcome carbon-enhanced ionisation effects in biological sample matrices. In most cases, the typical serum sample volume which is available for the analysis is limited to 0.5 ml or less, making multiple sample preparation for standard addition calibration impractical. Isotope dilution requires enriched isotopes and substantial sample preparation. Furthermore, the approximate Se concentration in every sample has to be known to adjust the appropriate amount of spike to each sample. Matrix matching with methanol has been described to overcome ionisation effects but we found limiting factors of this application when other trace elements are also determined within one sample run. This paper describes an effective sample preparation method which allows the direct determination of Se in serum without limiting the analytical capabilities for the additional determination of Al, Cu, Ni, Co, Cd, Mn and Zn in a single sample run by ICP-MS. Optimization procedures are presented and results of the analysis of reference samples are discussed, with a comparison of more than 150 serum data with those obtained by the GF-AAS method.  相似文献   

3.
The determination of trace and ultratrace elements in human serum by ICP-MS is described. The accuracy of the method is tested using a “second generation” human serum reference material. Elements determined include Fe, Co, Cu, Zn, Br, Rb, Sr, Mo, and Cs. The method is compared to nuclear analytical methods (NAA, PIXE). Perspectives for the future are also discussed.  相似文献   

4.
BackgroundHuman biomonitoring studies of trace elements in biological fluids are mostly limited to a certain number of elements or biological materials. In this study, we describe the significant extension of a biomonitoring to 73 elements being present in concentration ranges from ng/L to g/L in clinically relevant specimens such as blood, serum, erythrocytes and urine.MethodsThe samples were collected from 102 occupationally non-exposed inhabitants of northern Germany. The elements were determined either by inductively coupled plasma tandem mass spectrometry (ICP-MS/MS) in the low concentration range or by inductively coupled plasma optical emission spectrometry (ICP-OES) for essential trace elements and electrolytes.ResultsMean values and selected percentiles of element concentrations are presented for all sample materials. From the results, we calculated the distribution of elements between plasma and blood cells. Application of ICP-MS/MS improves selectivity and accuracy in the determination of elements that are strongly spectrally interfered, such as Cr, Ge, Pd or Ti in blood samples.ConclusionsThis publication provides very valuable information for occupational or environmental hygienists, toxicologists and clinical chemists due to the particularly high number of determined elements and presented concentration ranges.  相似文献   

5.
BackgroundTrace elements exhibit essential functions in many physiological processes. Thus, for research focusing on trace element homeostasis and metabolism analytical methods allowing for multi-element analyses are fundamental. Small sample amounts may be a big challenge in trace element analyses especially if also other end points want to be addressed in the same sample. Therefore, the aim of the present study was to examine trace elements (iron, copper, zinc, and selenium) in murine liver tissue prepared by a RIPA buffer-based lyses method.Methods and resultsAfter centrifugation, lysates and pellets were obtained and trace elements were analyzed with TXRF in liver lysates. The results were compared to that obtained by a standard microwave-assisted acidic digestion with subsequent ICP-MS/MS analysis of the same liver tissue, liver lysates, and remaining pellets. In addition, trace element concentrations, determined in murine serum with both methods, were compared. For serum samples, both TXRF and ICP-MS/MS provide similar and highly correlating results. Furthermore, in liver lysate samples prepared with RIPA buffer, comparable trace element concentrations were measured by TXRF as with the standard digestion technique and ICP-MS/MS. Only marginal amounts of trace elements were detected in the pellets.ConclusionTaken together, the results obtained by the present study indicate that the RIPA buffer-based method is suitable for sample preparation for trace element analyses via TXRF, at least for the here investigated murine liver samples.  相似文献   

6.
Reference values for trace and ultratrace elements concentrations in healthy human serum, measured by double-focusing inductively coupled plasma-mass spectrometry (ICP-MS), are presented. Blood donors from Asturias (Spain) were selected as the reference population (n=59). Blood samples were collected, after donation, taking the necessary precautions to avoid contamination. All subjects analyzed had normal renal function and nutritional status, as shown from their creatinine and albumin levels. A total number of 14 elements (Al, Ca, Cr, Mn, Fe, Co, Cu, Zn, Rb, Sr, Mo, Cd, Pb, and U) were monitored almost simultaneously. Serum samples were diluted 1+4 with ultrapure water and matrix interferences were corrected using Sc, Ga, Y, and Tl as internal standards. Fe, Cu, and Zn were also determined by isotope dilution analysis (IDA). Reference trace element concentrations intervals observed containing 95% of the reference distribution after excluding outliers are presented. Fourteen serum samples from hemodialysis patients were also analyzed for comparison. High levels of Al, Cr, Sr, Mo, Mn, Pb, U, Co, and Cu and low levels of Fe, Zn, and Rb were found in the serum samples from hemodialysis patients compared to the corresponding reference values observed in this work.  相似文献   

7.
建立了电感耦合等离子体质谱法(ICP-MS)测定茵栀黄注射液中Pb、As、Cd、Hg、Cu 5种元素的方法。样品经微波消解后,直接用ICP-MS同时测定上述5种元素,结果5种元素的检出限分别在5~1250 ng/L之间;线性良好,线性相关系数均为r≥0.999;精密度RSD3.5%;回收率在95.7%~107.5%之间。方法操作简便、分析速度快、灵敏度高,各项分析性能指标均达到要求,适用于茵栀黄注射液中有害元素的测定。  相似文献   

8.
A flow injection-inductively coupled plasma-mass spectrometry (FI-ICP-MS) with a simple sample preparation procedure was developed for the determination of selenium, copper, and zinc in blood serum/plasma. A serum/plasma sample was filtered through a 0.45-μm membrane filter and diluted with a mixture of trace elements in a standard solution (9∶1, v/v). Measurement of the reference serum sample confirmed the accuracy of our method for selenium, copper, and zinc concentration. In the case of blood plasma samples obtained from six healthy adult males, the selenium, copper, and zinc concentrations were similar to those of a typical healthy male in Japan. These results suggest that the sample prepartive procedure coupled with FI-ICP-MS can be used for the routine determination of selenium, copper, and zinc in human blood serum/plasma.  相似文献   

9.
The preparation of hair for the determination of elements is a critical component of the analysis procedure. Open-beaker, closedvessel microwave, and flowthrough microwave digestion are methods that have been used for sample preparation and are discussed. A new digestion method for use with inductively coupled plasma-mass spectrometry (ICP-MS) has been developed. The method uses 0.2 g of hair and 3 mL of concentrated nitric acid in an atmospheric pressurelow-temperature microwave digestion (APLTMD) system. This preparation method is useful in handling a large numbers of samples per day and may be adapted to hair sample weights ranging from 0.08 to 0.3 g. After digestion, samples are analyzed by ICP-MS to determine the concentration of Li, Be, B, Na, Mg, Al, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ge, As, Se, Rb, Sr, Zr, Mo, Pd, Ag, Cd, Sn, Sb, I, Cs, Ba, Pt, Au, Hg, Tl, Pb, Bi, Th, and U. Benefits of the APLTMD include reduced contamination and sample handling, and increased precision, reliability, and sample throughput.  相似文献   

10.
BackgroundAs part of Government of Canada’s Chemical Management Plan, substances containing aluminum (Al), bismuth (Bi), cerium (Ce), chromium (Cr), germanium (Ge), lanthanum (La), lithium (Li), neodymium (Nd), praseodymium (Pr), tellurium (Te), titanium (Ti) and yttrium (Y) were identified as priorities for risk assessment. Generating exposure estimates from all routes of exposure from multiple sources using a traditional approach for these elements can be challenging. The use of human biomonitoring (HBM) data would allow for direct and more precise assessment of the internal concentrations from all routes and all sources of exposure. There are no Canadian or North American population-level whole blood HBM data for the elements listed above. Therefore, this is the first biomonitoring project carried out to determine the concentrations of these elements from a nationally representative sample of Canadians.ObjectivesThe objective of this study was to generate whole blood concentrations for Al, Bi, Ce, Cr, Ge, La, Li. Nd, Pr, Te, Ti and Y in the Canadian population using biobank samples from the Canadian Health Measures Survey (CHMS) cycle 2 (2009–2011) for use in characterizing exposure in screening assessments and for establishing baseline concentrations to determine how exposures are changing over time.MethodsThe sample analysis was conducted by ICP-MS. A rigorous quality control and quality assurance process was implemented in order to generate data with high accuracy and precision while measuring low concentrations and minimizing possible inadvertent contamination.ResultsOf the elements analysed, the whole blood concentrations (μg/L) of Al, Ce, Cr, Ge, La, Nd, Pr, Te, Ti and Y in the Canadian population aged 3–79 years were below their respective method reporting limit (MRL). Two elements, Bi and Li were detected in 5 % and 66 % of the Canadian population. The median Li concentration was 0.47 μg/L.ConclusionThe results of this study provide information on concentrations of these elements in the Canadian population which can be utilized to characterize exposure in screening assessments and there by the potential for harm to human health. In addition, this study provides baseline HBM data which can be used as a comparative HBM dataset for other populations with similar exposure patterns.  相似文献   

11.
The ICP-MS for simultaneous trace element determination in human blood has prevailed as the most suitable methodology for clinical aims because of its rapidity, detection limits and minimal sample quantity needed for analysis.As the proteic matrix is high, it is necessary to fine-tune the ICP-MS Agilent 7500i with autosampler CETAC ASX-500 and ISIS System connected, and further we have to the sample pre-treatment in order to obtain good results.The study of the results shows that the best pre-treatment for blood serum samples consists of a basic treatment by 1/10 dilution with a solution of EDTA and NH4OH, with a detection limit of the order of μg/L and a reduction of the necessary patient sample volume to 2 mL.  相似文献   

12.
Inductively coupled plasma-mass spectrometry (ICP-MS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES) were used to determine age-related changes in the concentrations of constituent elements in the livers of Wistar rats of 1 week to 12 months old. At first, sample preparation and analytical conditions were investigated in order to set up a simple routine procedure for measuring multiple elements simultaneously. Seventeen elements in the standard reference samples of bovine and pork livers as well as rat liver samples could be determined with a reasonable precision and reproducibility. They were P, K, Na, Fe, Mg, Ca, Zn, Rb, Cu, Mn, Mo, Al, Co, Sr, Cs, Pb, and Cd in order of the levels of concentration in the adult rat livers. Of these elements, the five major elements (P, K, Na, Fe, Mg, Ca) were determined with ICP-AES and the others with ICP-MS. Although the number of animals was too small to draw a statistically definite conclusion, it seems that age-related changes in the concentrations of these elements could be categorized into three general patterns: (1) remaining essentially constant throughout the animal ages, as observed for P, K, Na, Mg, Ca, Rb, Sr, Cs, and Pb, (2) increasing with age, as observed for Fe, Mn, Mo, Co, and Cd, and (3) decreasing with age, especially in the early stages of growth, as observed for Cu and Zn.  相似文献   

13.
Native mussels, Diplodon chilensis, were sampled from four lakes in Nahuel Huapi National Park, Northern Patagonia, Argentina in order to evaluate heavy-metal distribution in the region and to assess the contribution of this compartment of the trophic web to their circulation in the food chain. The concentration of potential pollutants Ag, As, Cr, Hg, Sb, and Se, and other nine elements of interest (Ba, Br, Ca, Co, Cs, Fe, Na, Sr, and Zn) were determined in Diplodon chilensis pooled samples. Digestive glands were analyzed separately from soft tissues. Geological tracers Sc, Ta, Th, and rare earth elements were also determined in order to discriminate lithophile contributions. Elemental concentrations of Ba, Br, Fe, Sr, Se, and Zn in total soft tissues samples do not show significant differences among sampling sites. Arsenic and Cr contents in total soft tissues and digestive gland pooled samples are higher in sampling points close to zones with human settlements. Silver contents in samples collected in Lake Nahuel Huapi were higher than in the other lakes studied, and up to 50-fold higher than the sample collected in Lake Traful, considered as the reference. Mercury highest concentration values measured in total soft tissues pooled samples from lakes Nahuel Huapi and Moreno were found to be similar to those observed in other reported Hg contamination situations, and they are three to five times higher than those of the reference samples collected in Lake Traful.  相似文献   

14.
Concentrations of 14 trace elements (Bi, Cd, Co, Cs, Cu, Hg, Mn, Pb, Rb, Sb, Sn, Sr, Tl, and Zn) were determined by inductively coupled plasma mass spectrometry (ICP-MS) in 120 whole-blood and 121 plasma samples of 56 patients with angiographically documented coronary heart disease (CHD). One serum and two wholeblood reference materials were analyzed for quality control. At baseline, patients had elevated Co plasma as well as diminished Cu blood concentrations compared to healthy adults. The Zn concentrations in whole blood were below or at the lower end of the normal range, but the concentrations in plasma were elevated. All other trace elements were within the normal concentration ranges for healthy adults. After initial investigations, patients were randomly assigned to an experimental group (N = 27) and to a usual care group (N = 29). Experimental group patients were prescribed a lifestyle program that included a low-fat diet and a weekly moderate exercise. Patients were examined at baseline, after 6 and 12 mo for clinical assessment and fasting venous blood samples. No significant time-course changes in concentrations of trace elements in blood and plasma during the clinical treatment in both groups of patients could be observed. The experimental group patients lost weight and had lower blood pressure after 12 mo compared to baseline. The interventional therapy reduced the need for further revascularization procedures.  相似文献   

15.
A method is described for the determination of mercury in human blood serum and packed blood cells employing neutron activation analysis. Great attention was devoted to the collection and manipulation of the samples. The accuracy and precision of the method were tested by analyzing biological reference materials and by comparing the concentrations measured in a number of serum samples to those obtained by another, independent technique (cold vapor atomic absorption spectrometry) in the same samples. The article reports the levels measured in blood serum and packed blood cells samples from 15 adult volunteers, as well as the figures determined in a “second-generation” biological reference material (freeze-dried human serum), prepared and conditioned at the University of Ghent.  相似文献   

16.
Isotope ratio determination in boron analysis   总被引:1,自引:0,他引:1  
Traditionally, boron (B) isotope ratios have been determined using thermal ionization mass spectrometry (TIMS) and, to some extent, secondary ion mass spectrometry (SIMS). Both TIMS and SIMS use a high-resolution mass analyzer, but differ in analyte ionization methods. TIMS uses electrons from a hot filament, whereas SIMS employs an energetic primary ion beam of Ga+, Cs+, or O- for analyte ionization. TIMS can be used in negative or positive ion modes with high sensitivity and precision of B isotope ratio determination. However, isobaric interferences may be a problem, if the sample is not well purified and/or memory of the previous sample is not removed. Time-consuming sample preparation, analyte (B) purification, and sample determination processes limit the applications of TIMS for routine analyses. SIMS can determine B and its isotope ratio in intact solid samples without destroying them, but has poorer resolution and sensitivity than TIMS, and is difficult to standardize for biological samples. Development of plasma-source mass spectrometry (MS) enabled the determination of B concentration and isotope ratio without requiring sample purification. Commonly used plasma-source MS uses an Ar inductively coupled plasma (ICP) as an ionization device interfaced to a low-resolution quadrupole mass analyzer. The quadrupole ICP-MS is less precise than TIMS and SIMS, but is a popular method for B isotope ratio determination because of its speed and convenience. B determination by ICP-MS suffers no spectroscopic interferences. However, sample matrices, memory effects, and some instrument parameters may affect the accuracy and precision of B isotope ratio determination if adequate precautions are not taken. New generations of plasma-source MS instruments using high-resolution mass analyzers provide better sensitivity and precision than the currently used quadrupole ICP-MS. Because of the convenience and high sample throughput, the high-resolution ICP-MS is expected to be the method of choice for B isotope ratio determination. The current state of instrumental capabilities is adequate for B isotope determination. However, precision and accuracy are primarily limited by sample preparation, introduction, and analytical methodology, including 1. Analyte loss and isotope fractionation during sample preparation. 2. The precision of B isotope determination in small samples, especially those containing low concentrations. 3. Difficult matrices. 4. Memory effects. Sample preparation by alkali fusion allows rapid and complete decomposition of hard-to-digest samples, but high-salt environments of the fused materials require extensive sample purification for B ratio determination. The alternative wet-ashing sample decomposition with HF also results in B loss and isotopic fractionation owing to the high volatility of BF3. Open-vessel dry- or wet-ashing methods usually do not work well for animal samples, and are also prone to B loss and contamination. Closed-vessel microwave digestion overcomes these problems, but the digests of biological materials have high C contents, which cause spectral interference on 11B and affect 11B/10B ratios. Exchange separation/preconcentration of B using exchange (cation or anion exchange, B-specific resin, e.g., Amberlite IRA-743) tend to cause B isotope fractionation, and C eluting from these resin columns may interfere with B isotope ratio determination. Memory effects of B that occur during sample determination may cause serious errors in B isotope ratio determination, especially when samples varying in B concentrations and/or isotope composition are analyzed together. Although the utilization of high-resolution plasma-source MS will undoubtedly improve analytical precision, it is the sample preparation, sample introduction, and analytical methodology that represent the primary limitation to accurate and precise B isotope ratio determination.  相似文献   

17.
A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00–500 ng/mL, corresponding to a concentration range of 0.0300–15.0 μg/mL in 50 μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2 g strontium ranelate.  相似文献   

18.
Magnetic sector field inductively coupled plasma-mass spectrometry (ICP-MS) was applied to the reliable determination of the 8 essential trace elements cobalt (Co), chromium (Cr), copper (Cu), iron (Fe), manganese (Mn), nickel (Ni), selenium (Se), and vanadium (V) as well as the 7 nonessential and toxic elements silver (Ag), aluminum (Al), arsenic (As), gold (Au), platinum (Pt), scandium (Sc), and titanum (Ti) in 27 transitory and mature human milk samples and in 4 selected infant formulas. This advanced instrumentation can separate spectral overlaps from the analyte signal hampering significantly the determination of many trace elements by conventional ICP-MS. Moreover, superior detection limits in the picogram per liter range can be obtained with such magnetic sector field instruments. Therefore, this is the first study to report the concentrations of the elements Ag, Au, Pt, Sc, Ti, and V in human milk and in infant formulas. Concentrations of Ag (median: 0.41 μg/L; range: <0.13–42 μg/L) and Au (median: 0.29 μg/L; range 0.10–2.06 μg/L) showed large variations in human milk that might be associated with dental fillings and jewelry. Pt concentrations were very low with most of the samples below the method detection limit of 0.01 μg/L. Human milk concentrations of Co (median: 0.19 μg/L), Fe (380 μg/L), Mn (6.3 μg/L), Ni (0.79 μg/L), and Se (17 μg/L) were at the low end of the corresponding reference ranges. Concentrations of Cr (24.3 μg/L) in human milk were five times higher than the high end of the reference range. For Al (67 μg/L), As (6.7 μg/L), and V (0.18 μg/L), most of the samples had concentrations well within the reference ranges. All elemental concentrations in infant formulas (except for Cr) were approximately one order of magnitude higher than in human milk.  相似文献   

19.
Selected drugs from benzodiazepine, anabolic agent and non-steroidal anti-inflammatory drug (NSAID) therapeutic classes were extracted from water and serum using a supercritical CO2 mobile phase. The samples were extracted at a pump pressure of 329 MPa, an extraction chamber temperature of 45°C, and a restrictor temperature of 60°C. The static extraction time for all samples was 2.5 min and the dynamic extraction time ranged from 5 to 20 min. The analytes were collected in appropriate solvent traps and assayed by modified literature HPLC procedures. Analyte recoveries were calculated based on peak height measurements of extracted vs. unextracted analyte. The recovery of the benzodiazepines ranged from 80 to 98% in water and from 75 to 94% in serum. Anabolic drug recoveries from water and serum ranged from 67 to 100% and 70 to 100%, respectively. The NSAIDs were recovered from water in the 76 to 97% range and in the 76 to 100% range from serum. Accuracy, precision and endogenous peak interference, if any, were determined for blank and spiked serum extractions and compared with classical sample preparation techniques of liquid-liquid and solid-phase extraction reported in the literature. For the benzodiazepines, accuracy and precision for supercritical fluid extraction (SFE) ranged from 1.95 to 3.31 and 0.57 to 1.25%, respectively (n=3). The SFE accuracy and precision data for the anabolic agents ranged from 4.03 to 7.84 and 0.66 to 2.78%, respectively (n=3). The accuracy and precision data reported for the SFE of the NSAIDs ranged from 2.79 to 3.79 and 0.33 to 1.27%, respectively (n=3). The precision of the SFE method from serum was shown to be comparable to the precision obtained with other classical preparation techniques.  相似文献   

20.
A method for the determination of L-756 423, a novel HIV protease inhibitor, in human plasma and urine is described. Plasma and urine samples were extracted using 3M Empore extraction disk cartridges in the C18 and MPC (mixed-phase cation-exchange) formats, respectively. The extract was analyzed using HPLC with fluorescence detection (ex 248 nm, em 300 nm), and included a column switching procedure to reduce run-time. The assay was linear in the concentration range 5 to 1000 ng/ml when 1-ml aliquots of plasma and urine were extracted. Recoveries of L-756 423 were greater than 84% over the calibration curve range using the described sample preparation procedures. Intra-day precision and accuracy for this assay was less than 9% RSD and within 7%, respectively. Inter-day variabilities for the plasma (n=17) and urine (n=10) were less than 5% and 3% for low (15 ng/ml) and high (750 ng/ml) quality control samples. Bovine serum albumin (0.5%) was used as an additive to urine to prevent precipitation of L-756 423 during the storage of clinical samples. The assay was used in support of human clinical trials.  相似文献   