1.
We have established a highly sensitive high-performance liquid chromatographic method for the determination of an anticancer drug, UCN-01, in human plasma or urine. Using a fluorescence detector set at an excitation wavelength of 310 nm and emission monitored at 410 nm, there was a good linearity for UCN-01 in human plasma (r=0.999) or urine (r=0.999) at concentrations ranging from 0.2 to 100 ng/ml or 1 to 400 ng/ml, respectively. For intra-day assay, in plasma samples, the precision and accuracy were 1.8% to 5.6% and −10.0% to 5.2%, respectively. For inter-day assay, the precision and accuracy were 2.0% to 18.2% and 2.4% to 10.0%, respectively. In urine samples, the intra- and inter-day precision and accuracy were within 3.9% and ±2.7%, respectively. The lower limit of quantification (LLOQ) was set at 0.2 ng/ml in plasma and 1 ng/ml in urine. UCN-01 in plasma samples was stable up to two weeks at −80°C and also up to four weeks in urine samples. This method could be very useful for studying the human pharmacokinetics of UCN-01.  相似文献   

2.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid–liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1–5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83±6 and 92±6% in plasma, respectively, and 79±7 and 89±7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

3.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

4.
A sensitive and selective high-performance liquid chromatographic (HPLC) method was developed for the determination of pramipexole in human plasma and urine. Plasma/urine is made alkaline before pramipexole and BHT-920 (internal standard) are extracted by ethyl ether and back-extracted with a solution that contains heptanesulfonic acid. Separation is achieved by ion-pair chromatography on a Zorbax Rx C8 column with electrochemical detection at 0.6 V for plasma and ultraviolet detection at 286 nm for urine. The retention times of pramipexole and internal standard are approximately 14.4 and 10.7 min, respectively. The assay is linear in concentration ranges of 50 to 15 000 pg/ml (plasma) and 10 to 10 000 ng/ml (urine). The correlation coefficients are greater than 0.9992 for all curves. For the plasma method, the analysis of pooled quality controls (300, 3000, and 10 000 pg/ml) demonstrates excellent precision with relative standard deviations (R.S.D.) (n=18) of 1.1%, 2.3%, and 6.8%, respectively. For the urine method, quality control pools prepared at 30, 300, and 3000 ng/ml had R.S.D. values (n=18) of 2.9%, 1.7%, and 3.0%, respectively. The plasma and urine controls were stable for more than nine and three months, respectively. The mean recoveries for pramipexole and internal standard from plasma were 97.7% and 98.2%, respectively. The mean recoveries for pramipexole and internal standard from urine were 89.8% and 95.1%, respectively. The method is accurate with all intra-day (n=6) and overall (n=18) mean values for the quality control samples being less than 6.4 and 5.8% from theoretical for plasma and urine, respectively.  相似文献   

5.
An efficient method for the determination of atenolol in human plasma and urine was developed and validated. α-Hydroxymetoprolol, a compound with a similar polarity to atenolol, was used as the internal standard in the present high-performance liquid chromatographic analysis with fluorescence detection. The assay was validated for the concentration range of 2 to 5000 ng/ml in plasma and 1 to 20 μg.ml in urine. For both plasma and urine, the lower limit of detection was 1 ng/ml. The intra-day and inter-day variabilities for plasma samples at 40 and 900 ng/ml, and urine samples at 9.5 μg/ml were <3% (n=5).  相似文献   

6.
A rapid and sensitive method for extracting temazepam from human serum and urine is presented. Free temazepam is extracted from plasma and urine samples using n-butyl chloride with nitrazepam as the internal standard. Temazepam glucuronide is analyzed as free temazepam after incubating extracts with β-glucuronidase. Separation is achieved using a C8 reversed-phase column with a methanol—water—phosphate buffer mobile phase. An ultraviolet detector operated at 230 nm is used and a linear response is observed from 20 ng/ml to 10 μg/ml. The limit of detection is 15.5 ng/ml and the limit of quantitation is 46.5 ng/ml. Coefficients of variation are less than 10% for concentrations greater than 50 ng/ml. Application of the methodology is demonstrated in a pharmacokinetic study using eight healthy male subjects.  相似文献   

7.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

8.
A reversed-phase high-performance liquid chromatographic assay (HPLC) was utilized for monitoring xanomeline (LY246708/NNC 11–0232) and a metabolite, desmethylxanomeline, in human plasma. Xanomeline, desmethylxanomeline and internal standard were extracted from plasma with hexane at basic pH. The organic solvent extract was evaporated to dryness with nitrogen and the dried residue was reconstituted with 0.2 M HCl-methanol (50:50, v/v). A Zorbax CN 150 × 4.6 mm I.D., 5-μm column and mobile phase consisting of 0.5% (5 ml/l) triethylamine (TEA) adjusted to pH 3.0 with concentrated orthophosphoric acid-tetrahydrofuran (THF) (70:30, v/v) produced consistent resolution of analytes from endogenous co-extracted plasma components. Column effluent was monitored at 296 nm/0.008 a.u.f.s. and the assay limit of quantification was 1.5 ng/ml. A linear response of 1.5 to 20 ng/ml was sufficient to monitor plasma drug/metabolite concentrations during clinical trials. HPLC assay validation as well as routine assay quality control (QC) samples indicated assay precision/accuracy was better than ±15%.  相似文献   

9.
A method that allows the measurement of plasma and brain levels of the centrally-acting analgesic tramadol and its major metabolite (O-desmethyl tramadol) in mice and rats was developed using gas chromatography equipped with nitrogen–phosphorus detection (GC–NPD). Plasma samples were extracted with methyl tert.-butyl ether (MTBE) and were injected directly into the GC system. Brain tissue homogenates were precipitated with methanol, the resulting supernatant was dried then acidified with hydrochloric acid. The aqueous solution was washed with MTBE twice, alkalinized, and extracted with MTBE. The MTBE layer was dried, reconstituted and injected into the GC system. The GC assay used a DB-1 capillary column with an oven temperature ramp (135 to 179°C at 4°C/min). Dextromethorphan was used as the internal standard. The calibration curves for tramadol and O-desmethyl tramadol in plasma and brain tissue were linear in the range of 10 to 10 000 ng/ml (plasma) and ng/g (brain). Assay accuracy and precision of back calculated standards were within ±15%.  相似文献   

10.
11.
A selective, accurate, precise and reproducible high-performance liquid chromatographic assay was developed for the quantitation of irbesartan, an angiotensin II antagonist, in human plasma and urine samples. The method involved solid-phase extraction of irbesartan and internal standard (I.S.) using a 100-mg Isolute CN cartridge. A portion of the eluate was injected onto an ODS analytical column connected to a fluorescence detector that was set at an excitation wavelength of 250 nm and an emission wavelength of 371 nm. The mobile phase consisted of 50% acetonitrile and a 50% weak phosphate-triethylamine solution, pH 3.5, at a flow-rate of 0.8 ml/min. The assay was linear from 1 to 1000 ng/ml with both plasma and urine. In either matrix, the lower limit of quantitation was 1 ng/ml. The analyses of quality control samples indicated that the nominal values could be predicted with an accuracy >95%. The inter- and intra-day coefficients of variation for the analyses in both matrices were <8%. Irbesartan was stable in both human plasma and urine for at least seven months at −20°C. The application of the assay to a pharmacokinetic study is described.  相似文献   

12.
A new method based on fluorescence derivatization with 5‐(dimethylamino) naphthalene‐1‐sulfonyl chloride (dansyl chloride) was developed for the quantitative determination of galantamine in human plasma and urine using high‐performance liquid chromatography. The reaction between galantamine and dansyl chloride was optimally realized in 30 min at room temperature and pH 10.5, with a reagent to galantamine molar ratio of 2.13. The derivative was extracted with dichloromethane, and the extract was dried under a nitrogen stream and dissolved in the mobile phase. Chromatographic analysis was performed with an Inertsil C18 column and a mobile phase comprising 40% acetonitrile and 60% 10 mM o‐phosphoric acid, 1.2 ml/min. The injection volume was 20 μl. The derivatives were detected with a fluorescence detector (excitation 375 nm/emission 537 nm). The retention time for the dansyl derivative of galantamine was 16.8 min. Linearity was observed between 125 and 2000 ng/ml in water, urine and plasma. The limit of detection and limit of quantification for the developed method were 6.27–70.99 and 18.81–212.97 ng/ml, respectively. Per cent recovery was calculated as 95.15 for urine and 95.78 for plasma. Interday repeatability values for urine and plasma samples (n = 6) at three different concentrations were calculated as a per cent relative standard deviation of 0.24–0.59 and 0.35–0.56. The corresponding per cent relative standard deviation values for intraday repeatability were 0.13–0.51 and 0.04–0.15, respectively.  相似文献   

13.
Automated procedures for the determination of CGP 33 101 in plasma and the simultaneous determination of CGP 33 101 and its carboxylic acid metabolite, CGP 47 292, in urine are described. Plasma was diluted with water and urine with a pH 2 buffer prior to extraction. The compounds were automatically extracted on reversed-phase extraction columns and injected onto an HPLC system by the automatic sample preparation with extraction columns (ASPEC) automate. A Supelcosil LC-18 (5 μm) column was used for chromatography. The mobile phase was a mixture of an aqueous solution of potassium dihydrogen phosphate, acetonitrile and methanol for the assay in plasma, and of an aqueous solution of tetrabutylammonium hydrogen sulfate, tripotassium phosphate and phosphoric acid and of acetonitrile for the assay in urine. The compounds were detected at 230 nm. The limit of quantitation was 0.11 μml/l (25 ng/mol) for the assay of CGP 33 101 in plasma, 11 μmol/l (2.5 μg/ml) for its assay in urine and 21 μmol/l (5 μg/ml) for the assay of CGP 47 292 in urine.  相似文献   

14.
A new, rapid and sensitive high-performance liquid chromatographic method for the analysis of paclitaxel (Taxol) in human plasma and urine was developed and validated. After addition of an internal standard, paclitaxel was extracted from plasma or urine by a liquid–liquid extraction using diethyl ether. Extraction efficiency averaged 90%. Chromatography was performed isocratically on a reversed-phase column monitored at 227 nm. Retention times were 7.7 and 6.7 min for paclitaxel and docetaxel, respectively, and the assay was linear in the range 25–1000 ng/ml. The limits of quantification for paclitaxel were 25 and 40 ng/ml in plasma and urine, respectively. The assay was shown to be suitable for pharmacokinetic studies of children involved in a phase I clinical trial.  相似文献   

15.
Three high-performance liquid chromatographic methods are described for the detection of the novel antifolate anticancer drug (6R)-5,10-dideaza-5,6,7,8-tetrahydrofolate (lometrexol): one with fluorometric detection and two with detection by UV absorbance. An assay for plasma lometrexol using UV detection (288 nm) and reversed-phase chromatography was developed, with a quantitation limit of 0.2 μg/ml and linearity up to 10 μg/ml. This assay was modified for measurement of lometrexol in urine, with a quantitation limit of 2 μg/ml and linearity up to 25 μg/ml. An alternative assay for plasma lometrexol using derivatization and fluorescence detection (excitation at 325 nm, emission at 450 nm) was also developed, which proved twenty-fold more sensitive (quantitation limit of 10 ng/ml) than the UV assay, and which was linear up to 250 ng/ml. The fluoremetric method requires sample oxidation with manganese dioxide prior to analysis, and uses ion-pair chromatography with tetramethylammonium hydrogensulphate as an ion-pair reagent. All assays use a similar preliminary solid-phase extraction method (recovery as assessed by UV absorption >73%), with C10-desmethylene lometrexol added for internal standardisation. Each assay is highly reproducible (inter-assay precision in each assay is <10%). Applicability of the fluorescence-based assay to lometrexol in plasma and the UV-based assay lometrexol in urine is demonstrated by pharmacokinetic studies in patients treated as part of a Phase I clinical evaluation of the drug.  相似文献   

16.
An assay for the simultaneous quantitative determination of thioTEPA, TEPA and the recently identified metabolite N,N′-diethylene-N″-2-chloroethylphosphoramide (monochloroTEPA) in human urine has been developed. MonochloroTEPA was synthesized by incubation of TEPA with sodium chloride at pH 8. Thus, with this assay monochloroTEPA is quantified as TEPA equivalents. Analysis of the three analytes in urine was performed using gas chromatography with selective nitrogen–phosphorous detection after extraction with a mixture of 1-propanol and chloroform from urine samples. Diphenylamine was used as internal standard. Recoveries ranged between 70 and 100% and both accuracy and precision were less than 15%. Linearity was accomplished in the range of 25–2500 ng/ml for monochloroTEPA and 25–5000 ng/ml for thioTEPA and TEPA. MonochloroTEPA proved to be stable in urine for at least 4 weeks at −80°C. ThioTEPA, TEPA and monochloroTEPA cummulative urinary excretion from two patients treated with thioTEPA are presented demonstrating the applicability of the assay for clinical samples and that the excreted amount of monochloroTEPA exceeded that of thioTEPA on day 2 to 5 of urine collection.  相似文献   

17.
A simple method for creatinine determination was developed using high-performance liquid chromatography (HPLC) to more accurately monitor serum creatinine levels in experimental animal models when compared to the Jaffé method. The new HPLC procedure will replace the traditional Jaffé method for rhesus monkey kidney function studies. We developed an isocratic method using a polymeric, hydrophilic, silica-based strong cation-exchange bed with a 5.0 mmol/l lithium acetate matrix, pH 4.9, which isolates creatinine with no detectable impurities as determined by three-dimensional ultraviolet–visible spectral analysis. Sample preparation includes deproteination with acetonitrile, evaporation, and resolubilization in mobile phase followed by quantitation with UV detection at 234 nm. Extraction efficiency across the measured range was 96±2%. From numerous extracted rhesus monkey creatinine curves (n=38) a slope of 251 100±756 (95% CI) and an intercept of 675.6±712.7 (95% CI) was calculated. Extraction efficiency and peak purity tests with human plasma were cross-compared with rhesus monkey serum producing equivalent results. An average of 120 samples can be run daily.  相似文献   

18.
A selective high-performance liquid chromatographic (HPLC) assay for a sigma receptor antagonist, DuP 734 (I), in rat plasma has been developed. Compound I and internal standard, XC031 (I.S.), were first extracted from plasma into an ethyl acetate—toluene mixture (3:7, v/v) and then back-extracted into freshly prepared phosphoric acid (0.03 M). Separation of I and I.S. with no interference from endogenous substances was achieved on a reversed-phase octyl column and detection was by UV at 229 nm. The mobile phase consisted of acetonitrile—glacial acetic acid—triethylamine—0.05 M ammonium acetate (670:4:2:2000, v/v). Using 0.5 ml of rat plasma for extraction, the limit of quantitation was 43 ng/ml and the assay was linear from 43 to 8536 ng/ml. The intra- and inter-day coefficients of variation ranged from 0.7 to 3.0%, and from 1.4 to 14.5%, respectively, over the entire concentration range. The accuracy was within 16.1% of the spiked concentrations. I was stable in frozen plasma at −20°C for at least 68 days.  相似文献   

19.
A high-performance liquid chromatographic method for the quantitation of nimesulide in human plasma is presented. The method is based on protein precipitation with methanol and reversed-phase chromatography with spectrophotometric detection at 404 nm. The separation was performed on a Nucleosil 120-5 C18, 50×4-mm I.D. column and the mobile phase consisted of acetonitrile–methanol–15 mM potassium dihydrogenphosphate buffer, pH 7.3 (30:5:65, v/v). Only 250 μl of plasma are used for sample preparation and no internal standard is necessary. The limit of quantitation is 80 ng/ml and the calibration curve is linear up to 10 000 ng/ml. More than 20 samples can be analysed within 1 h. Within-day and between-day precision expressed by relative standard deviation is less than 5% and inaccuracy does not exceed 8%. The assay was used for pharmacokinetic studies.  相似文献   

20.
A high-performance liquid chromatographic assay for O6-benzylguanine utilizing liquid-liquid extraction and reversed-phase chromatography has been developed. Plasma samples were alkalinized, extracted into ethyl acetate, evaporated, and the residues were constituted and chromatographed. Separation was accomplished by gradient elution with a mobile phase of methanol, acetonitrile, and phosphate buffer, pH 3.2. Eluted compounds were detected spectrophotometrically at 280 nm. Sample quantitation was obtained from the regression line of six-point standard curves ranging from 25 to 400 ng/ml. O6-Benzylguanine peak heights were compared to peak heights of O6-(p-chlorobenzyl)guanine (internal standard). The average regression coefficient was 0.999 (n = 4). High concentration (305 ng/ml) and low concentration (38 ng/ml) quality control samples were determined with a day-to-day relative standard deviation of 7 and 8%, respectively (n = 18). The within-day relative standard deviations were 2.7 and 3.0% (n = 18) for the high and low concentration quality control specimens, respectively. Sample quantitation was reliable to 25 ng/ml with a signal-to-noise ratio of 8:1. This method was applied to plasma samples obtained from patients in a clinical trial of O6-benzylguanine.  相似文献   