首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Purpose: To determine levels of urinary aflatoxin M1 (AFM1) in children and correlate the concentrations with previously reported aflatoxin albumin adduct (AF-alb) levels in these children.

Materials and methods: Matched urine and blood samples were collected from 84 Tanzanian children aged 6–14 months old. From 31 children in one village (Kigwa), samples were collected at three time points six months apart. Samples were collected from 31 and 22 children from two different regions at the second time point only. Urinary AFM1 was measured using a commercial enzyme-linked immunosorbent assay (ELISA) kit with a modified protocol to improve sensitivity. AF-alb was measured using an established ELISA method.

Results: The relative ranking of the three villages for exposure to aflatoxin based on either AFM1 or AF-alb biomarker measurements was the same. In Kigwa village, both AFM1 and AF-alb levels were higher at six months post-harvest compared to baseline. However, at the next visit, the AFM1 levels dropped from a GM (interquartile range) of 71.0 (44.7, 112.6) at visit two to 49.3 (31.5, 77.3) pg/ml urine, whereas AF-alb levels increased from 47.3 (29.7, 75.2) to 52.7 (35.4, 78.3) pg/mg albumin between these two visits, reflecting the fact that AFM1 measures short-term exposure, whereas AF-alb measures longer term exposure. There was a correlation between AFB1 intake and AFM1 excretion (r=?0.442, p?≤?0.001).

Conclusions: Urinary AFM1 is a good biomarker for AFB1 exposure in Tanzanian children, reflecting geographical and temporal variations in exposure to this foodborne toxin.  相似文献   

2.
A sensitive and specific method was developed and validated for the quantitation of quercetin in human plasma and urine. The application of liquid chromatography-tandem mass spectrometry (LC/MS/MS) with a TurboIonspray (TIS) interface in negative mode under multiple reactions monitoring was investigated. Chromatographic separation was achieved on a C12 column using a mobile phase of acetonitrile/water with 0.2% formic acid (pH 2.4) (40/60, v/v). The detection limit was 100 pg/ml and the lower limit of quantification was 500 pg/ml for plasma samples; the detection limit was 500 pg/ml and the lower limit of quantification was 1 ng/ml for urine samples. The calibration curve was linear from 1 to 800 ng/ml for plasma samples and was linear from 1 to 200 and 50 to 2000 ng/ml for urine samples. All the intra- and inter-day coefficients of variation were less than 11% and intra- and inter-day accuracies were within +/-15% of the known concentrations. This represents a LC/MS/MS assay with the sensitivity and specificity necessary to determine quercetin in human plasma and urine. This assay was used to determine both parent quercetin and the quercetin after enzymatic hydrolysis with beta-glucuronidase/sulfatase in human plasma and urine samples following the ingestion of quercetin 500 mg capsules.  相似文献   

3.
An extractionless method for determining aflatoxin M1 (AFM1), a major metabolite of aflatoxin B1 (AFB1), in human urine was developed. The biological fluid is injected directly into the chromatographic system after simple dilution and centrifugation. A pre-column, packed with a cation-exchange phase and coupled on-line to a column-switching liquid chromatography (LC) system, is used for sample pre-treatment and concentration. The analytes are non-selectively desorbed with the LC eluent and cleaned by means of a column-switching procedure. Pre-treatment and analysis were performed within 40 min. Average AFM1 recovery reached 97% in the 10–100 ng/l range of urine. The detection limit of AFM1 in urine and milk was 2.5 ng/l for 1 ml of injected sample. A comparison with an immunoaffinity column clean-up and LC method was performed. The method was applied to determine AFM1 in the urine of AFB1 gavaged rats, and in the urine of both potentially exposed and supposedly unexposed workers. The method was also extended to milk.  相似文献   

4.
Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml).  相似文献   

5.
An ultra-sensitive sandwich ELISA was developed for detection of AFM1 in milk. The assay involved the immobilization of rat monoclonal antibody of AFM1 in 384 microtiter plate to capture AFM1 antigen. This was detected by tracer secondary rabbit poly-clonal antibody labelled with horseradish peroxidase upon addition of a luminol-based substrate. Milk samples with different fat percentage were analyzed after pre-treatment. Linear range of AFM1 detection 250-6.25 pg/mL was achieved in 3% fat milk. The miniaturised assay (10 μL) enabled ultra trace analysis of AFM1 in milk with much improved lower limit of detection at 0.005 pg/mL. A sensitive magnetic nanoparticles (MNPs) based ELISA was also developed and coupled with micro plate ELISA for analysis in milk. The hybrid-assay, by coupling the 1°Ab immobilized MNPs column with microwell plate assay enabled simultaneous measurement of low (0.5 pg/mL) and high AFM1 contamination (200 pg/mL). The most promising feature of this MNPs-ELISA is the small column size, high capture efficiency and lower cost over other reported materials. The proposed assay can be deployed for simultaneous analysis and monitoring of AFM1 in milk.  相似文献   

6.
Highly sensitive immunoassays have been used to quantitate aflatoxins (AF) and N-nitrosamines (NNO) in human body fluids and tissues, respectively. This approach was taken in order to quantitate environmental exposure to these agents at an individual level to facilitate the investigation of their role in the etiology of human cancer. In order to analyse AF in human urine, an immunopurification step has been developed by using AF-specific antibody bound to AH-Sepharose 4B gel in a small (4-ml gel volume) affinity column prior to enzyme-linked immunosorbent assay (ELISA). The ELISA can be used to quantitate aflatoxin B1 (AFB1) over the range 0.01 ng/ml to 10 ng/ml and the assay system has been validated by using human urine samples spiked with AFB1 over this concentration range. In addition, 29 urine samples from the Philippines have been analysed and found to contain a range of levels from zero to 4.25 ng/ml AFB1 equivalent with a mean of 0.875 ng/ml. This compared with a mean of 0.066 ng/ml AFB1 equivalent in samples from France. Radioimmunoassay of O6-methyldeoxyguanosine (O6-medG) has been performed on human oesophageal and cardiac stomach mucosal DNA from tissue samples obtained during surgery in Linxian County, People's Republic of China, an area of high risk for both oesophageal and stomach cancer. Using the methodology described and having 1 mg of hydrolyzed DNA allows the detection of approximately 25 fmol O6medG per mg DNA.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
A monoclonal antibody was obtained from BALB/c mice immunized with aflatoxin Bl (AFB1) conjugated to bovine serum albumin. This IgG2a antibody, ASCI, with K light chain has a high specificity for AFB1. In an indirect enzyme-linked immunosorbent assay the antibody litre in ascites fluid was 1: 6000 for 50% binding to plates coated with aflatoxin-poly-L-lysine. The assay is sensitive to 2.5 pg aflatoxin/assay. ASCI cross-reacts with closely related aflatoxin metabolites such as AFB2, AFM1 and AFG1. However, ASCI displays negligible cross-reactivity with other related aflatoxin analogues such as AFM2, AFP1, AFQ1 and aflatoxicol. An immunoabsorbent was prepared by coupling ASCI antibody to Ultrogel AcA 22. This immunomatrix was used to purify aflatoxins at 0–1 ng/ml levels from contaminated body fluids such as bovine milk. The antibody affinity column was regenerated and re-used several times. Owing to its high specificity for AFB1 and AFM1, ASCI will be of value in immunodetection and immunopurification of these toxins in various foodstuffs.  相似文献   

8.
We report a method for the simultaneous determination of methamphetamine, amphetamine and their hydroxylated metabolites in plasma and urine samples using a GC-NPD system. The analytical procedures are: (1) adjust the sample to pH 11.5 with bicarbonate buffer, saturate with NaCl and extract with acetate; (2) back-extract the amines in the ethyl acetate fraction with 0.1 M HCl; (3) adjust the pH of the acid fraction to 11.5 and follow by extraction in ethyl acetate; (4) reduce the volume of ethyl acetate under nitrogen and derivatize the concentrate with trifluoroacetic anhydride or heptaflourobutyric anhydride before the GC analysis. The derivatives were separated on a GC-NPD system equipped with a HP-5 column of 25 m×0.32 m I.D. and a 0.52 μm film of 5% phenylmethylsilicone. The detection limit (taking a signal-to-noise ratio of 2) of heptafluorobutyl derivatives of methamphetamine and its metabolites in plasma and the trifluoroacetyl derivatives in urine was 1 ng/ml (22 pg on column). The limit of quantitation of the heptafluorobutyl derivatives in the plasma was 1 ng/ml (22 pg on column), and that of the trifluoroacetyl derivatives in urine was 20 ng/ml (73 pg on column). The between-day variation was from 0.9 to 17.4% and within-day variation from 0.9 to 8.3%. This method was used successfully in the quantitative determination of methamphetamine and its p-hydroxylated metabolites in the plasma and urine of human subjects.  相似文献   

9.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

10.
There is an urgent need for improved tools for laboratory diagnosis of active tuberculosis (TB). Here, we describe two methods, a catch-up ELISA and a dipstick test based on the detection in urine of lipoarabinomannan (LAM). LAM is a major and specific glycolipid component of the outer mycobacterial cell wall. Preliminary experiments showed that LAM is excreted in the urine of mice injected intraperitoneally with a crude cell wall preparation of Mycobacterium tuberculosis. Both methods were highly sensitive, detecting LAM at concentrations of 1 ng/ml and 5 pg/ml, respectively. Of 15 patients with active TB, all showed intermediate to high levels of LAM in their urine (absorbance values from 0.3 to 1.2, mean 0.74). Only one sample showed an absorbance value below the chosen cut off value of 0.4. All but one of the urine samples from 26 healthy nursing workers exhibited OD value below 0.4 cut off. These methods may prove valuable for rapid and simple diagnosis of TB in particular in developing countries lacking biosafety level 3 (BSL3) facilities.  相似文献   

11.
T S Fan  G S Zhang    F S Chu 《Applied microbiology》1984,47(3):526-532
Antibodies against aflatoxin Q1 (AFQ1) were obtained from rabbits after immunization of either AFQ1-hemisuccinate or AFQ2a conjugated to bovine serum albumin. Both radioimmunoassay and enzyme-linked immunosorbent assaY (ELISA) were used for the determination of antibody titers and specificities. Antibodies obtained from rabbits after immunization with AFQ1-hemisuccinate-bovine serum albumin had the highest affinity to aflatoxin B1, whereas antibodies obtained from rabbits after immunization with AFQ2a-bovine serum albumin bound most effectively with AFQ2a. AFQ2a antibody was selected for the subsequent direct and indirect ELISA for the detection of AFQ1 in biological fluids. When AFQ2a-peroxidase and AFQ2a antibody were used, direct ELISA was able to detect as low as 2 ppb (ng/ml) of AFQ1 spiked in the urine samples that had been subjected to a Sep-Pak cleanup treatment. In indirect ELISA in which the antigen (AFQ2a-bovine serum albumin) was coated to the solid phase followed by reaction with rabbit antibody and goat anti-rabbit immunoglobulin G-peroxidase conjugate, 50-fold less antibody was used without sacrificing sensitivity. Recoveries of AFQ1 added to urine samples (2 to 40 ppb) were 46.3 to 73% and 65.8 to 85.8% for direct and indirect ELISA, respectively.  相似文献   

12.
Antibodies against aflatoxin Q1 (AFQ1) were obtained from rabbits after immunization of either AFQ1-hemisuccinate or AFQ2a conjugated to bovine serum albumin. Both radioimmunoassay and enzyme-linked immunosorbent assaY (ELISA) were used for the determination of antibody titers and specificities. Antibodies obtained from rabbits after immunization with AFQ1-hemisuccinate-bovine serum albumin had the highest affinity to aflatoxin B1, whereas antibodies obtained from rabbits after immunization with AFQ2a-bovine serum albumin bound most effectively with AFQ2a. AFQ2a antibody was selected for the subsequent direct and indirect ELISA for the detection of AFQ1 in biological fluids. When AFQ2a-peroxidase and AFQ2a antibody were used, direct ELISA was able to detect as low as 2 ppb (ng/ml) of AFQ1 spiked in the urine samples that had been subjected to a Sep-Pak cleanup treatment. In indirect ELISA in which the antigen (AFQ2a-bovine serum albumin) was coated to the solid phase followed by reaction with rabbit antibody and goat anti-rabbit immunoglobulin G-peroxidase conjugate, 50-fold less antibody was used without sacrificing sensitivity. Recoveries of AFQ1 added to urine samples (2 to 40 ppb) were 46.3 to 73% and 65.8 to 85.8% for direct and indirect ELISA, respectively.  相似文献   

13.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method has been developed for the determination of trenbolone in bovine urine and serum. The aim was a control of the misuse of trenbolone in food-producing animals. The procedure involved, in both cases, a preliminary solid-phase clean-up followed by a liquid-liquid extraction for urine samples after a preliminary enzymatic hydrolysis. The extracts have been directly analysed by reversed-phase LC-MS-MS in selected reaction monitoring (SRM), acquiring two diagnostic product ions from the chosen precursor [M+H](+). The procedures were validated across the concentration range of 1-1500 ng/ml. The linearity, the inter- and intra-day accuracy and precision have been determined. The procedure was specific and the accuracy values were better than 20% at the limit of quantitation of spiked samples. The limit of quantification (LOQ) and the limit of detection (LOD) were, respectively, 1 ng/ml and 350 pg/ml for urine and serum. According to the draft, SANCO/1805/2000, we determined the decision limit CCalpha and the detection capability CCbeta. The recovery values for urine ranged from 87 to 128%, and for plasma the recovery was 70+/-4%. The procedure proved to be simple and suitable for routine and confirmatory purposes such as those developed for residue studies.  相似文献   

14.
This study was undertaken to investigate whether the concentration of carbonic anhydorase isoenzyme I (CA-I) in canine feces and urine is useful as a temporary marker of occult blood. Concentrations of CA-I were measured by enzyme-linked immunosorbent assay (ELISA). Fecal CA-I concentrations in 113 healthy beagle dogs (50 male and 63 female) of various ages ranged from 4.3 to 16.7 ng/g feces (mean; 7.0 +/- 2.9 ng/g feces). One milliliter of blood from 3 healthy beagle dogs was found to contain 1,047, 1,062 and 1,150 microg CA-I. The fecal CA-I concentrations of dogs receiving intragastric infusions of autologous blood (10 ml) were very low. However, the fecal CA-I concentrations of dogs receiving infusion of autologous blood (5 ml) into the ascending colon were very high. Detection of fecal CA-I would be useful for identifying dogs with hemorrhaging of the large intestine. Of 55 urinary samples collected from healthy beagle dogs by catheter, chemical tests for occult blood were negative in 44, but CA-I concentrations ranged from 1.8 to 12.6 ng/ml (mean; 6.9 +/- 5.4 ng/ml) by ELISA. The CA-I concentrations of the other 11 samples, which tested positive for occult blood on chemical testing, ranged from 41.2 to 525.0 ng/ml by ELISA. Although CA-I is not a specific marker of erythrocytes, CA-I may be used to detect occult blood in canine feces and urine until a specific immunological test kit using antibody for Hb is developed.  相似文献   

15.
The aim of this study was to analyse the presence of vascular endothelial growth factor (VEGF) and interferon alpha (IFN-α) in the follicular fluid (FF) and their possible influence, as pro-angiogenic or anti-angiogenic factors, on in vitro fertilization outcome. The concentrations of VEGF and IFN-α were correlated with oocyte and embryo quality, concentrations of hormones in the serum, perifollicular blood flow and endometrial thickness. VEGF was detected in all FF samples (median 706.6?pg/ml, range 182.9–6638?pg/ml). IFN-α was detected in 60% of the samples (median 6.5?pg/ml, range 0–79.4?pg/ml), while in 40% of the samples its levels were below the test detection limit. VEGF and IFN-α concentrations did not correlate with the cause of infertility, concentrations of FSH, LH, E2 and prolactin, oocyte or embryo quality. Significantly higher concentrations of VEGF have been found in women with primary compared with secondary infertility (p?=?0.011, Mann Whitney test). The concentrations of VEGF and IFN-α did not correlate with the resistance index (RI) on days of hCG administration, follicular aspiration and embryo transfer. However, the concentrations of IFN-α correlated with endometrial thickness on the day of embryo transfer (Spearman correlation coefficient ρ?=?0.4107; P?<?0.05) but not on days of hCG administration and follicular aspiration. The mechanism of VEGF association with the previous ability of having a child needs to be clarified in future studies. The results of this study indicate a possible role of IFN-α in pathways of endometrial remodelling.  相似文献   

16.
Interleukin (IL)-32 is a recently identified proinflammatory cytokine that is one of the IL-18 inducible genes, and plays an important role in autoimmune and inflammatory diseases. We produced antibodies against IL-32 and studied the expression of IL-32 in human stomach cancer. We detected IL-32 secreted from K-562 cells that werw stably transfected with IL-32 and in the sera of stomach cancer patients, by a sandwich ELISA using a monoclonal antibody KU32-52 and a polyclonal antibody. In order to optimize a sandwich immunoassay, recombinant IL-32alpha was added, followed by the addition of a biotinylated KU32-52 into microtiter plate wells precoated with a goat anti-IL-32 antibody. The bound biotinylated KU32-52 was probed with a streptavidin conjugated to HRP. This sandwich ELISA was highly specific and had a minimal detection limit of 80 pg/ml (mean+/-SD of zero calibrator) and measuring up to 3,000 pg/ml. This ELISA showed no cross-reaction with other cytokines such as hIL-1alpha, hIL-1beta, hIL-2, hIL-6, hIL-8, hIL-10, hIL-18, and hTNF-alpha. Intra-assay coefficients of variation were 18.5% to 4.6% (n=10), and inter-assay coefficients were 23% to 9% (n=10). The average IL-32 level in the sera of 16 stomach cancer patients (189 pg/ml) was higher than that of 12 healthy control men (109 pg/ml). Our results indicate that serum IL-32 level can be detected by using an established ELISA, and that this immunoassay and mAb KU32-09 specific for immunohistochemistry can be used in the detection of expressed and secreted IL- 32 in stomach cancer patients.  相似文献   

17.
To investigate the endocrine cause of reproductive suppression in nonbreeding female naked mole-rats, animals from 35 colonies were studied in captivity. Urinary and plasma progesterone concentrations were elevated in pregnant females (urine: 10.0-148.4 ng/mg Cr, 27 samples from 8 females; plasma: 3.6-30.0 ng/ml, 5 samples from 5 females; Days 21-40 of pregnancy) and cyclic breeding females (urine: 0.5-97.8 ng/mg Cr, 146 samples from 7 females; plasma: less than 1.0-35.4 ng/ml, 25 samples from 7 females). The latter group showed cyclic patterns of urinary progesterone, indicating a mean ovarian cycle length of 34.4 +/- 1.6 days (mean +/- s.e.m.) with a follicular phase of 6.0 +/- 0.6 days and a luteal phase of 27.5 +/- 1.3 days (19 cycles from 9 breeding females). In non-breeding females urinary and plasma progesterone values were undetectable (urine: less than 0.5 ng/mg Cr, 232 samples from 64 females; plasma: less than 1.0 ng/ml, 7 samples from 6 females). Breeding females had higher (P less than 0.001) plasma LH concentrations (3.0 +/- 0.2 mi.u./ml, 73 samples from 24 females) than did non-breeding females (1.6 +/- 0.1 mi.u./ml, 57 samples from 44 females). Urinary and plasma progesterone concentrations in non-breeding females from wild colonies situated near Mtito Andei, Kenya, were either below the assay sensitivity limit (urine: less than 0.5 ng/mg Cr, 11 females from 2 colonies; plasma: less than 1.0 ng/ml, 25 females from 4 colonies), or very low (plasma: 1.6 +/- 0.6 ng/ml, 15 females from 4 colonies). In captivity, non-breeding females removed from their colonies (i.e. the dominant breeding female) and either paired directly with a non-breeding male (N = 2), or removed and housed singly for 6 weeks before pairing with a non-breeding male (N = 5) may develop a perforate vagina for the first time in as little as 7 days. Urinary progesterone concentrations rose above 2.0 ng/mg Cr (indicative of a luteal phase) for the first time 8.0 +/- 1.9 days after being separated. These results suggest that ovulation is suppressed in subordinate non-breeding female naked mole-rats in captive and wild colonies, and show that plasma LH concentrations are significantly lower in these non-breeding females. This reproductive block in non-breeding females is readily reversible if the social factors suppressing reproduction are removed.  相似文献   

18.
Contamination of milk and dairy products with aflatoxin M1 (AFM1) presents a risk for human health. The aim of this study was to investigate the presence of AFM1 in pasteurized milk samples in Fariman, located in the province of Khorasan Razavi, Iran, by enzyme-linked immunosorbent assay (ELISA). Forty-five samples of pasteurized milk from different supermarkets were collected during 3 months in summer (July to September, 2012). AFM1 contamination was detected in all of milk samples. The mean concentration of aflatoxin M1 was 27.2 ng/l. The range of AFM1 content was 8.8–64 ng/l. Thirteen (28.8 %) of the samples had AFM1 levels exceeding the maximum levels (50 ng/l) accepted by the European Union. Due to the fact that milk is used by all the age groups including infants and children in Fariman city, it is necessary to minimize the health risk from AFM1 contamination in milk. For this reason, the level of its precursor, aflatoxin B1 (AFB1), in dairy feeds must be reduced, requiring constant aflatoxin monitoring of relevant agricultural commodities.  相似文献   

19.
A rapid, reliable and specific reversed-phase high-performance liquid chromatographic procedure is described for the determination of diphenylpyraline hydrochloride at nanogram concentrations in plasma and urine. After extraction of the drug with n-pentane-2-propanol (50:1) from alkalinized samples, the organic extract was evaporated to dryness, reconstituted with methanol and chromatographed using a 5-μm Asahipak ODP-50 C18 column with UV detection at 254 nm. The elution time for diphenylpyraline was 7.9 min. The overall recovery of diphenylpyraline from spiked plasma and urine samples at concentrations ranging from 53 to 740 ng/ml were 94.65% and 92.29%, respectively. Linearity and precision data for plasma and urine standards after extraction were acceptable. The limit of detection was 15 ng/ml for both plasma and urine samples at 0.002 AUFS.  相似文献   

20.
Intravesical immunotherapy for bladder cancer is the most effective form of tumour immunotherapy. Following repeated instillations of bacillus Calmette-Guérin (BCG) organisms into the bladder large 0quantities of several cytokines are detected in the urine. These cytokines include interleukins IL-1β, IL-2, IL-4, IL-6, IL-8, IL-10, tumour necrosis factor α (TNFα), interferon γ (IFNγ) and also soluble intercellular adhesion molecule ICAM-1. In the work reported here we simultaneously quantified urinary levels of TNFα, TNFβ, TNF receptor I and TNF receptor II by enzyme-linked immunosorbent assay (ELISA) techniques and compared this with bioactive levels of TNF. This was undertaken with a limited number of patients throughout a course of six instillations of immuno therapy. Sequential instillations of BCG induced secretion of TNFα and TNFβ into urine. These cytokines were not always secreted simultaneously, perhaps suggesting differential regulation of their synthesis. Maximal concentrations of TNFα were 675 pg/ml and TNFβ 47 pg/ml. High levels of both species of soluble TNF receptor were readily identified in urine. Maximal levels of sTNF-RI were 6200 pg/ml (range from 0) and for sTNF-RII 7800 pg/ml (range from 0). Contrasting with earlier published observations concerning cytokine levels, the concentration of soluble receptor did not increase with repeated instillation. In apparent contrast with the ELISA data, very low levels of bioactive TNF were identified by the L929 bioassay (maximum concentration 1 U/ml) despite the elevated concen t ration of immunoreactive TNF. The large concentrations of soluble TNF receptor in patients’ urine samples could account for the apparently low bioactivity as determined by the L929 cytotoxicity assay. The precise nature of the role of TNF in BCG immunotherapy remains undetermined; however, it is thought that proinflammatory cytokines are in part responsible for the clinical efficacy of this therapeutic approach. Whether other cytokines are antogonised by soluble binding proteins remains to be determined. Furthermore, whether TNF is bioactive in the bladder wall and only neutralised in the urine also requires investigation. Received: 24 August 1994 / Accepted: 17 October 1994  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号