首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
A high throughput bioanalytical method based on solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS), has been developed for the estimation of perindopril and its metabolite perindoprilat, an angiotensin-converting enzyme inhibitor in human plasma. Ramipril was used as internal standard (IS). The extraction of perindopril, perindoprilat and ramipril from the plasma involved treatment with phosphoric acid followed by solid phase extraction (SPE) using hydrophilic lipophilic balance HLB cartridge. The SPE eluate without drying were analyzed by LC-MS/MS, equipped with turbo ion spray (TIS) source, operating in the negative ion and selective reaction monitoring (SRM) acquisition mode to quantify perindopril and perindoprilat in human plasma. The total chromatographic run time was 1.5 min with retention time for perindopril, perindoprilat and ramipril at 0.33, 0.35 and 0.30 min. The developed method was validated in human plasma matrix, with a sensitivity of 0.5 ng/ml (CV, 7.67%) for perindopril and 0.3 ng/ml (CV, 4.94%) for perindoprilat. This method was extensively validated for its accuracy, precision, recovery, stability studies and matrix effect especially because the pattern of elution of all the analytes appears as flow injection elution. Sample preparation by this method yielded extremely clean extracts with very good and consistent mean recoveries; 78.29% for perindopril, 76.32% for perindoprilat and 77.72% for IS. The response of the LC-MS/MS method for perindopril and perindoprilat was linear over the range 0.5-350.0 ng/ml for perindopril and 0.3-40 ng/ml for perindoprilat with correlation coefficient, r>/=0.9998 and 0.9996, respectively. The method was successfully applied for bioequivalence studies in human subjects samples with 4 mg immediate release (IR) formulations.  相似文献   

2.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection has been developed for the determination of rizatriptan in human plasma. Following a single-step liquid-liquid extraction with methyl tertiarybutyl ether, the analytes were separated using a mobile phase consisting of 0.05% (v/v) triethylamine in water (adjusting to pH 2.75 with 85% phosphoric acid) and acetonitrile (92:8, v/v). Fluorescence detection was performed at an excitation wavelength of 225nm and an emission wavelength of 360nm. The linearity for rizatriptan was within the concentration range of 0.5-50ng/ml. The intra- and inter-day precisions of the method were not more than 8.0%. The lower limit of quantification (LLOQ) was 0.5ng/ml for rizatriptan. The method was sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

3.
A rapid and specific liquid chromatographic mass spectrometric (LC-MS-MS) method has been developed for the determination of paroxetine in human plasma. The procedure involves a liquid-liquid extraction of paroxetine and fluoxetine (internal standard) with cyclohexane-ethyl acetate. The standard curve was linear over a working range of 0.2-50 ng/ml. The lower limit of quantitation was 0.2 ng/ml. No endogenous compounds were found to interfere with the analysis. The absolute recovery was 70.8% for paroxetine and 84.1% for the internal standard. The accuracy of inter-assay and intra-assay accuracy was in the ranges -4.8 to -0.5% and -3.4 to 4.8%, respectively. This method proved to be suitable for bioequivalence studies by being simple, selective and reproducible.  相似文献   

4.
A sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of bufuralol enantiomers in plasma and pharmaceutical formulations. Enantiomeric resolution was achieved on a vancomycin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic V with UV detection set at 254 nm. The polar ionic mobile phase (PIM) consisting of methanol-glacial acetic acid-triethylamine (100:0.015:0.010, v/v/v) has been used at a flow rate of 0.5 ml/min. The method is highly specific where other coformulated compounds did not interfere. The stability of bufuralol enantiomers under different degrees of temperature was also studied. The results showed that the drug is stable for at least 7 days at 70 degrees C. The method was validated for its linearity, accuracy, precision and robustness. An experimental design was used during validation to evaluate method robustness. The calibration curves in plasma were linear over the range of 5-500 ng/ml for each enantiomer with detection limit of 2 ng/ml. The mean relative standard deviation (RSD) of the results of within-day precision and accuracy of the drug were 0.05) between inter- and intra-day studies for each enantiomer which confirmed the reproducibility of the assay method. The mean extraction efficiency for S-(-)- and R-(+)-bufuralol from plasma was in the range 97-102% at 15-400 ng/ml level for each enantiomer. The overall recoveries of bufuralol enantiomers from pharmaceutical formulations was in the range 99.6-102.2% with %RSD ranging from 1.06 to 1.16%. The assay method proved to be suitable as chiral quality control for bufuralol formulations by HPLC and for therapeutic drug monitoring.  相似文献   

5.
The combination of two sensitive, selective and reproducible reversed phase liquid chromatographic (RP-HPLC) methods was developed for the determination of artesunate (AS), its active metabolite dihydroartemisinin (DHA) and mefloquine (MQ) in human plasma. Solid phase extraction (SPE) of the plasma samples was carried out on Supelclean LC-18 extraction cartridges. Chromatographic separation of AS, DHA and the internal standard, artemisinin (QHS) was obtained on a Hypersil C4 column with mobile phase consisting of acetonitrile-0.05 M acetic acid adjusted to pH 5.2 with 1.0M NaOH (42:58, v/v) at the flow rate of 1.50 ml/min. The analytes were detected using an electrochemical detector operating in the reductive mode. Chromatography of MQ and the internal standard, chlorpromazine hydrochloride (CPM) was carried out on an Inertsil C8-3 column using methanol-acetonitrile-0.05 M potassium dihydrogen phosphate adjusted to pH 3.9 with 0.5% orthophosphoric acid (50:8:42, v/v/v) at a flow rate of 1.00 ml/min with ultraviolet detection at 284 nm. The mean recoveries of AS and DHA over a concentration range of 30-750 ng/0.5 ml plasma and MQ over a concentration of 75-1500 ng/0.5 ml plasma were above 80% and the accuracy ranged from 91.1 to 103.5%. The within-day coefficients of variation were 1.0-1.4% for AS, 0.4-3.4% for DHA and 0.7-1.5% for MQ. The day-to-day coefficients of variation were 1.3-7.6%, 1.8-7.8% and 2.0-3.4%, respectively. Both the lower limit of quantifications for AS and DHA were at 10 ng/0.5 ml and the lower limit of quantification for MQ was at 25 ng/0.5 ml. The limit of detections were 4 ng/0.5 ml for AS and DHA and 15 ng/0.5 ml for MQ. The method was found to be suitable for use in clinical pharmacological studies.  相似文献   

6.
Betamethasone is a synthetic corticosteroid designed to exert a marked glucocorticoid activity. As the free alcohol, betamethasone finds widespread clinical applications related to its anti-inflammatory and immunosuppressant activity. In the present study, a fast, sensitive, robust method was developed for the determination and quantification of betamethasone in human plasma by liquid chromatography coupled with tandem mass spectrometry, using photospray ionization in negative mode. Betamethasone was extracted from 0.5 ml human plasma by liquid-liquid extraction (LLE) using chloramphenicol as internal standard. The method has a chromatographic run of 2.5 min using a C(18) analytical column (100 mm x 2.1 mm i.d.) and the linear calibration curve over the range was linear from 0.05 to 50 ng ml(-1) (r(2)>0.993). The between-run precision, based on the relative standard deviation replicate quality controls was 94.1% (0.15 ng ml(-1)), 90.7% (4.0 ng ml(-1)) and 97.2% (40 ng ml(-1)). The between-run accuracy for the above-mentioned concentrations was 11.9, 9.0 and 9.8%, respectively. The method herein described was employed in a bioequivalence study of two formulations of dexchlorpheniramine/betamethasone 2 mg/0.25 mg tablets.  相似文献   

7.
A fast liquid chromatographic assay with mass spectrometric detection (LC/MS) has been developed and validated for the simultaneous determination of methadone (MT), its primary metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP) and alprazolam, in human plasma. The extraction procedure was performed with automatic solid phase extraction, and the compounds were separated with a Sunfire column using a gradient mode. Deuterated analogues for all of the analytes of interest were used for quantitation. Limits of detection (LOD) were established between 0.5 and 1 ng/ml. Linearity was obtained over a range of 2-2,000 ng/ml with an average correlation coefficient (R(2)) of >0.99. Intra- and inter-batch coefficients of variation and relative mean errors were less than 10% for all analytes and concentrations. The recoveries were higher than 50.0% in all cases. The method proved to be suitable for evaluation of plasma obtained from patients enrolled in a MT-maintenance program who are frequently treated with alprazolam as a sedative.  相似文献   

8.
A high-performance liquid chromatographic method for the enantiospecific quantitation of S- and R-mephenytoin and its metabolites S- and R-nirvanol and S- and R-4'-hydroxymephenytoin in plasma is described. The compounds were separated using a reversed-phase C(2) column in tandem with a chiral alpha(1)-acid glycoprotein column and were detected using ultraviolet detection at 205 nm. The lower limit of quantification was 10 ng/ml for all compounds using 0.5 ml human plasma (intra-day coefficient of variation <13%, accuracy <+/-20%). The method was validated for human plasma in the concentration range 10-2000 ng/ml for each of the six compounds. The method allows for the simultaneous characterisation of the metabolic capacity of two human drug-metabolising enzymes, CYP2C19 and CYP2B6, and may be used when investigating polymorphisms or changes in activity of these two enzymes.  相似文献   

9.
A sensitive enantioselective liquid chromatographic assay with mass spectrometric detection (LC-MS) has been developed and validated for the simultaneous determination of saliva concentrations of (R)- and (S)-methadone (Met) and (R)- and (S)-2-ethylidene-1,5-dimethyl-3,3-diphenyl-pyrrolidine (EDDP, a primary metabolite of Met). Saliva specimens were collected using Salivette devices (Sarsedt), and centrifuged; collected saliva was then spiked with deuterated internal standards, D3-Met and D3-EDDP, and directly injected into the LC-MS. Enantioselective separations were achieved on a liquid chromatographic chiral stationary phase (CSP) based upon immobilized alpha(1)-acid glycoprotein (AGP) using a mobile phase composed of acetonitrile: ammonium acetate buffer (10mM, pH 7.0) in a ratio of 18:82 (v/v), a flow rate of 0.9 ml/min and a temperature of 25 degrees C. Under these conditions, enantioselective separations were observed for methadone (alpha=1.30) and EDDP (alpha=1.17) within 15 min. Met, EDDP, D3-Met and D3-EDDP were detected using selected ion monitoring at m/z 310.20, 278.20, 313.20 and 281.20, respectively. Linear relationships between peak height ratio and drug-enantiomer concentrations were obtained for methadone in the range of 5.0-600.0 ng/ml, and for EDDP from 0.5 to 15.0 ng/ml per enantiomer with correlation coefficients better than 0.9994, where lower limit of quantification (LLOQ) for Met was 5 ng/ml and for EDDP 0.5 ng/ml. Acceptable intra- and inter-day precision of the method (CVs<4.0%) and accuracy (CVs<4.0%) were obtained. These findings demonstrate the accuracy and precision of the method used to successfully analyze saliva obtained from patients enrolled in a methadone-maintenance program.  相似文献   

10.
A rapid, selective, sensitive and reproducible liquid chromatographic method with tandem mass spectrometric detection has been developed and validated for the analysis of a new specific bradycardic agent, ivabradine (S 16257) and six potentially active metabolites in human plasma. Isolation of these compounds and of the internal standard was performed by an automated solid-phase extraction system using Oasis cartridges. Separation and detection of ivabradine and its metabolites were achieved using a C18 column and a MS–MS detector with a positive electrospray ionization source. Ivabradine and its metabolites gave a linear response ranging from 0.1 or 0.2 to 20 ng/ml and the limits of quantitation ranged from 0.1 to 0.2 ng/ml using a 0.5 ml plasma sample size. A complete validation demonstrated the method to be accurate, precise and specific for the simultaneous quantification of ivabradine and its metabolites in human plasma. The method was subsequently applied to the quantitative determination of ivabradine and its metabolites in human plasma samples from healthy volunteers participating in a clinical study to provide pharmacokinetic data.  相似文献   

11.
A practical and sensitive high-performance liquid chromatographic method using normal solid-phase extraction has been developed for the determination of methotrexate (MTX) and its main metabolite 7-hydroxymethotrexate (7-OH-MTX) in human urine. A urine specimen followed by the addition of pH 5.0 acetate buffer was purified by solid-phase extraction on a Sep-Pak silica cartridge. The analyte was chromatographed on a reversed-phase Inertsil ODS-2 column using phosphate buffer-acetonitrile at pH 5.3 as the mobile phase, and the effluent from the column was monitored at 303 nm. A good linear relationship between peak height and concentration was found for both of MTX and 7-OH-MTX in the range 5 to 1000 ng/ml of human urine. The inter-day coefficients of variation for the assay (n=5) were 8.8% (5 ng/ml), 3.4% (50 ng/ml) and 2.0% (500 ng/ml) for MTX, and 7.2, 2.7 and 2.3% for 7-OH-MTX in urine, respectively. The present method should prove useful for the evaluation of urinary drug excretion in patients undergoing MTX low-dose therapy.  相似文献   

12.
It has been suggested that GTS-21 can improve the learning deficits and inhibit the neuro-degeneration in patients with Alzheimer's disease. This paper describes a reversed-phase high-performance liquid chromatographic assay with visible detection at 405 nm for determination of GTS-21 and its metabolite, 4-hydroxy-GTS-21 in rat plasma. The method uses solid-phase extraction with a Bond Elut C18 column. A quantitation limit of 1.0 ng/ml was achieved using 0.5 ml of rat plasma. In the validation study, the coefficients of variation and the relative errors of each compound were less than 10%. Also freeze-thaw and storage stability were confirmed. This method has proved to be applicable to the pharmacokinetic study of GTS-21 in rats.  相似文献   

13.
A reversed phase high-performance liquid chromatographic (HPLC) method with UV detection was developed for the simultaneous determination of imatinib (Gleevec, Glivec, STI571) and AMN107 in cultured tumour cells, using clozapine as an internal standard. The compounds of interest were extracted by liquid-liquid extraction using TOXI-TUBES((R)) A extraction tubes. Chromatographic separation was performed on a Phenomenex Gemini C18 reversed phase column (150 mm x 2.0 mm, 5 microm particle size), using a mixture of 65% CH(3)OH (methanol) and 35% NH(4)Ac (Ammonium acetate) buffer (20mM, pH 10). Separation was achieved under isocratic conditions at a flow rate of 0.5 ml/min. Imatinib, clozapine and AMN107 are detected by UV detection at 260 nm. Calibration curves were linear from 50 to 7500 ng/ml with correlation coefficients (r(2)) better than 0.998. The limit of quantitation (LOD) was 50 ng/ml. The method has been successfully applied to a cellular kinetics study.  相似文献   

14.
A sensitive chromatographic assay has been developed for m-iodobenzylguanidine (MIBG) in human plasma based on the derivatization with benzoin. MIBG is first isolated from plasma using solid-phase extraction on a cyanopropyl-modified silica phase. After evaporation of the eluate, a fluorescent derivative is formed using benzoin. The derivative is analysed by reversed-phase liquid chromatography using a mixture 60% (v/v) acetonitrile, 30% (v/v) water and 10% (v/v) of the 0.5 M Tris buffer (pH 8.0) as the eluent and fluorescence detection at 320 nm for excitation and 435 nm for emission, respectively. In the evaluated concentration range (2–200 ng/ml) precisions 10% and accuracies in between 90 and 100% have been found, with 2 ng/ml being the lower limit of quantification using a 0.5-ml plasma sample volume. The assay can also be used without the internal standard benzylguanidine. The assay was successfully used to obtain a pharmacokinetic curve of MIBG.  相似文献   

15.
A high-performance liquid chromatographic assay, suitable for pharmacokinetic studies, has been developed for the new tricyclic antidepressant Ro 11-2465, at present under clinical investigation. For concentrations above 0.5 ng/ml, the method involves a simple extraction at basic pH with an organic solvent followed by direct chromatography of this extract on a silica gel column using fluorescence detection. For concentrations below 0.5 ng/ml, an extensive clean-up procedure is required. In both procedures, however, evaporation of the extract and reconstitution of the residue is avoided. The detection limit, using 1 ml of plasma, is about 0.1 ng/ml. This sensitivity is sufficient for following single-dose kinetics of Ro 11-2465 in man.  相似文献   

16.
A high-performance liquid chromatographic method has been developed for the determination of pipotiazine in human plasma and urine. After selective extraction, pipotiazine and the internal standard (7-methoxypipotiazine) are chromatographed on a column packed with Spherosil XOA 600 (5 μm) using a 7:3 (v/v) mixture of diisopropyl ether—isooctane (1:1, v/v) + 0.2% triethylamine and diisopropyl ether—methanol (1:1, v/v) + 0.2% triethylamine + 2.6% water. The eluted compounds are measured by fluorescence detection. The sensitivity of the method was established at 0.25 ng/ml pipotiazine in plasma and 2 ng/ml pipotiazine in urine (C.V. < 5%). The method has been successfully applied to a pharmacokinetic study following a single oral administration of 10 mg of pipotiazine.  相似文献   

17.
A simple, rapid, sensitive and specific reversed-phase high performance liquid chromatographic (RP-HPLC) method involving ultraviolet detection (lambda = 210 nm) was developed for analysis of indinavir along with propranolol in samples obtained from ex vivo intestinal permeability studies. Chromatography was carried out on C-18 column with mobile phase comprising of phosphate buffer-acetonitrile (68:32, v/v) pumped at flow rate of 1 ml/min. The proposed method has a short run time of 12 min and involves a simple sample preparation for the purpose of reducing permeability model artifacts and to concentrate the samples. Fluorescein was used as internal standard. The proposed method has been validated with regard to specificity, detection limit, recovery, accuracy and precision. For both the drugs, method was found to be selective, linear (R(2) approximately 0.999), accurate (recovery = 100-105%) and precise (<3% R.S.D.) in the range of 2-20 microg/ml. The limit-of-detection and limit-of-quantification of the method were 40 ng/ml and 100 ng/ml for indinavir, and 30 and 80 ng/ml for propranolol, respectively. Indinavir, a widely prescribed HIV protease inhibitor, suffer from bioavailability problems where involvement of P-glycoprotein mediated drug efflux may play a significant role. The proposed method was successfully applied for intestinal permeability of indinavir to estimate the contribution of P-glycoprotein in limiting its oral bioavailability. The advantage of the developed method lies in the simultaneous determination of propranolol, a passive integrity marker, routinely employed in permeability studies and its selectivity in presence of various P-gp modulators and permeability markers.  相似文献   

18.
A simple and sensitive column-switching HPLC method has been developed for the simultaneous determination of NK-104 (HMG–CoA reductase inhibitor) and its lactone in human and dog plasma. Plasma sample was extracted with methyl tert-butyl ether and then the extract was subjected to methylation with diazomethane to prevent the mutual conversion between NK-104 and its lactone. The extract was injected into the column-switching HPLC system. The calibration curves of NK-104 and NK-104 lactone were linear over the ranges 0.5 to 100 ng/ml for human plasma samples and 0.5 to 500 ng/ml for dog plasma, respectively. The intra-day and inter-day C.V. values of these analytes were less than 13.3%. The intra-day and inter-day accuracies of these analytes were between −14.0 and 6.5%. The proposed method has been applied to plasma samples obtained after oral administration of a single 2 mg dose of NK-104 to volunteers.  相似文献   

19.
A method based on LC-MS-MS is described for the determination of methyldopa in human plasma using dopa-phenyl-D3 as the internal standard. The method has a chromatographic run time of 5.5 min and was linear in the range of 20-5000 ng/ml. The limit of quantitation was 20 ng/ml, the intra-day precisions were 7.3, 5.4 and 4.3% and the intra-day accuracies were -8.0, -1.3 and -2.0% for 30, 600 and 3000 ng/ml, respectively. The inter-day precisions were 7.7, 0.5 and 0.7% and the inter-day accuracies were 0.2, -1.1 and -2.3%, respectively, for the above concentrations. This method was employed in a bioequivalence study of two tablet formulations of methyldopa.  相似文献   

20.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号