首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The purpose of this study was to determine whether surface electromyography (EMG) assessment of myoelectric manifestations of muscle fatigue is capable of detecting differences between the vastus lateralis and medialis muscles which are consistent with the results of previous biopsy studies. Surface EMG signals were recorded from the vastus medialis longus (VML), vastus medialis obliquus (VMO) and vastus lateralis (VL) muscles during isometric knee extension contractions at 60% and 80% of the maximum voluntary contraction (MVC) for 10 s and 60 s, respectively. Initial values and rate of change of mean frequency (MNF), average rectified value (ARV) and conduction velocity (CV) of the EMG signal were calculated. Comparisons between the two force levels revealed that the initial values of MNF for the VL muscle were greater at 80% MVC compared to 60% MVC (P < 0.01). Comparisons between the vasti muscles demonstrated lower initial values of CV for VMO compared to VL at 60% MVC (P < 0.01) and lower than VML and VL at 80% MVC (P < 0.01). In addition, initial values of MNF were higher for VL with respect to both VML and VMO at 80% MVC (P < 0.01) and initial estimates of ARV were higher for VMO compared to VML at both force levels (P < 0.01 at 60% MVC and P < 0.05 at 80% MVC). For the sustained contraction at 80% MVC, VL demonstrated a greater decrease in CV over time compared to VMO (P < 0.05).These findings suggest that surface EMG signals and their time course during sustained isometric contractions may be useful to non-invasively describe functional differences between the vasti muscles.  相似文献   

2.
Electromyographic (EMG) abnormalities that reveal denervation and reinnervation caused by lower motor neuron degeneration do not reflect the number of motor units that determines muscle strength. Consequently, motor unit activity potential (MUAP) parameters do not reflect muscle dysfunction.The aim of the study was to compare the value of motor unit number estimation (MUNE) and MUAP parameters as indicators of clinical muscle dysfunction in patients with amyotrophic lateral sclerosis (ALS), and to analyze the role of MUNE as a supplement to the EMG criteria for the diagnosis of ALS.In 25 patients with ALS, MUNE by the multipoint incremental method in the abductor digiti minimi (ADM) and quantitative EMG in the first dorsal interosseous (FDI) were obtained. The Medical Research Council (MRC) scale was used to evaluate clinical muscle dysfunction. A strong correlation between the number of motor units evaluated by MUNE and ADM clinical function by the MRC scale was found (P < 0.001). An increased value of surface-detected single motor action potential was associated with a decreased MRC score for ADM (P < 0.1). No relation was found between MUAP parameters in FDI and MRC scores. Our data support the value of the MUNE method for the detection of motor unit loss in ALS, and it could be postulated that MUNE studies may be considered complementary tests for ALS in a future revision of ALS criteria.  相似文献   

3.
Motor unit properties were analyzed in patients with upper motor neuron syndrome (UMNS). Multi-channel surface electromyographic (EMG) signals were recorded for 300 s from the biceps brachii muscle of seven male subacute patients (time from lesion, mean ± SE, 4.9 ± 1.0 months). In three patients, both arms were investigated, leading to 10 recorded muscles. Patients were analyzed in rest-like condition with motor units activated due to pathological muscle overactivity. For a total of 12 motor units, the complete discharge pattern was extracted from EMG decomposition. Interpulse interval variability was 7.8 ± 0.9%. At minimum discharge rate (6.4 ± 0.4 pulses per second, pps), conduction velocity was smaller than at maximum discharge rate (12.0 ± 0.9 pps) in all motor units (3.60 ± 0.21 m/s vs. 3.84 ± 0.20 m/s). Conduction velocity changed by 1.35 ± 0.48% (different from zero, P < 0.01) for each increase of 1 pps in discharge rate. It was concluded that conduction velocity of low-threshold motor units in subacute patients with UMNS had similar values as reported in healthy subjects and was positively correlated to instantaneous discharge rate (velocity recovery function of muscle fibers).  相似文献   

4.
Little is known about the motor control of the lumbo-pelvic musculature in microgravity and its simulation (bed-rest). Analysis of spectral and temporal electromyographic variables can provide information on motor control relevant for normal function. This study examined the effect of 56-days of bed-rest with 1-year follow-up in 10 male subjects on the median frequency and the activation timing in surface electromyographic recordings from five superficial lumbo-pelvic muscles during a repetitive knee movement task. Trunk fat mass (from whole body-composition measurements) and movement accuracy as possible explanatory factors were included. Increased median frequency was observed in the lumbar erector spinae starting late in bed-rest, but this was not seen in its synergist, the thoracic erector spinae (p < .0001). These changes persisted up to 1-year after bed-rest and were independent of changes in body-composition or movement accuracy. Analysis suggested decreases of median frequency (p < .0001) in the abdominal and gluteal muscles to result from increased (p < .01) trunk fat levels during and after bed-rest. No changes in lumbo-pelvic muscle activation timing were seen. The results suggest that bed-rest particularly affects the shorter lumbar erector spinae and that the temporal sequencing of superficial lumbo-pelvic muscle activation is relatively robust.  相似文献   

5.
Studies have demonstrated that the electromyographic (EMG) amplitude versus submaximal isometric force relationship is relatively linear. The purpose of this investigation was to determine the minimum number of contractions required to study this relationship. Eighteen men (mean age = 23 years) performed isometric contractions of the leg extensors at 10–90% of the maximum voluntary contraction (MVC) in 10% increments while surface EMG signals were detected from the vastus lateralis and vastus medialis. Linear regression was used to determine the coefficient of determination, slope coefficient, and y-intercept for each muscle and force combination with successively higher levels included in the model (i.e., 10–30%,  10–90% MVC). For the slope coefficients, there was a main effect for force combination (P < .001). The pairwise comparisons showed there was no difference from 10–60% through 10–90% MVC. For the y-intercepts, there were main effects for both muscle (vastus lateralis [4.3 μV RMS] > vastus medialis [−3.7 μV RMS]; P = .034) and force combination (P < .001), with similar values shown from 10–50% through 10–90% MVC. The linearity of the absolute EMG amplitude versus isometric force relationship for the vastus lateralis and vastus medialis suggests that investigators may exclude high force contractions from their testing protocol.  相似文献   

6.
The purposes of this study were to attempt to record surface electromyography (EMG) from the superficial region of vastus intermedius (VI) and to investigate the influence of adjacent muscle activity on surface EMG of VI. First, serial axial magnetic resonance imaging of the thigh was performed for 45 healthy young men to determine morphological characteristics of the VI. Second, surface EMG activity of the VI and other quadriceps femoris (QF) muscle group components were recorded in maximum voluntary contraction during isometric knee extension from 11 healthy young men. To test cross-talk of EMG signals between VI and the nearest adjacent muscle, vastus lateralis (VL), we applied cooling for 20-min on VL to selectively alter activity. Cooling the skin above a muscle is known to decrease median frequency (MF) of EMG signal of the muscle. All subjects displayed a superficial region in VI sufficiently large (14 cm2) to record surface EMG. Surface EMG of VI could be detected in the same scale as other QF muscle group components. Cooling induced a significant MF decrease only in VL (from 92.5 to 44.2 Hz, p < 0.001), but no significant change was observed in VI (from 63.8 to 61.7 Hz). From this result, we concluded the muscle activity of VL is negligible on surface EMG detected from VI during isometric contraction.  相似文献   

7.
This study compares muscle fiber conduction velocities estimated using surface electromyography during isometric maximal voluntary contraction in different stages of diabetic neuropathy. Eighty-five adults were studied: 16 non-diabetic individuals and 69 diabetic patients classified into four neuropathy stages, defined by a fuzzy expert system: absent (n = 26), mild (n = 21), moderate (n = 11) and severe (n = 11). Average muscle fiber conduction velocities of gastrocnemius medialis, tibialis anterior, vastus lateralis and biceps femoris were assessed using linear array electrodes, and were compared by ANOVA. Conduction velocities were significantly decreased in the moderate neuropathy group for the vastus lateralis compared to other groups (from 18% to 21% decrease), and were also decreased in all diabetic groups for the tibialis anterior (from 15% to 20% from control group). Not only the distal anatomical localization of the muscle affects the conduction velocity, but also the proportion of muscle fiber type, where the tibialis anterior with greater type I fiber proportion is affected earlier while the vastus lateralis with greater type II fiber proportion is affected in later stages of the disease. Generally, the muscles of the lower limb have different responsiveness to the effects of diabetes mellitus and show a reduction in the conduction velocity as neuropathy progresses.  相似文献   

8.
The purpose of this study was to investigate whether age-related changes in motor unit (MU) contractile properties are reflected in parameters of motor unit action potentials (MUAPs). MUs of the medial gastrocnemius muscle were functionally isolated in anaesthetized Wistar rats. A control group of young animals (5–10 mo) was compared to two groups of old rats (24–25 mo and 28–30 mo). The basic contractile properties of MUs as well as the amplitude, total duration, peak-to-peak time, and number of turns within MUAPs were measured. Effects of aging were mainly observed for fast fatigable MUs (a prolongation of MUAPs and increased number of turns). The MUAP amplitude did not change significantly with aging in either MU type, but it correlated to the twitch or tetanic forces, which tended to increase with age, especially for slow MUs. We concluded that the prolongation of MUAPs and the greater incidence of signal turns was probably a result of a decrease in muscle fiber conduction velocity and/or an increase in their dispersion, and enlargement of MU territories – presumably caused by axonal sprouting of surviving motoneurons. The latter might also be responsible for the observed age-related tendency for a increase in MUAP amplitudes in slow MUs.  相似文献   

9.
The purpose of this study was to examine the influence of interelectrode distance (IED) over the estimated innervation zone (IZ) for the vastus lateralis muscle and normalization on the torque-related patterns of responses for electromyographic (EMG) amplitude and mean power frequency (MPF) during concentric isokinetic, eccentric isokinetic, and isometric muscle actions of the leg extensors. Eight men performed submaximal to maximal concentric isokinetic, eccentric isokinetic, and isometric muscle actions of the dominant leg extensors. Surface EMG signals were recorded simultaneously with two bipolar electrode arrangements in single differential configuration (20 and 40 mm IEDs) placed over the estimated IZ for the vastus lateralis muscle and a third electrode arrangement in single differential configuration (20 mm IED) placed distal to the estimated IZ. The results indicated that there were only a few (six of 90 statistical comparisons) significant (p < 0.05) mean differences among the three electrode arrangements for absolute EMG amplitude. There were no mean differences among the three electrode arrangements for absolute or normalized EMG MPF values or normalized EMG amplitude for the three types of muscle actions. Thus, it may be possible to reduce the potential influence of the IZ on amplitude and spectral parameters of the EMG signal through normalization.  相似文献   

10.
Fibromyalgia is a common chronic pain condition in the population (2–4%), which often is associated with prominent negative consequences with respect to participation in daily activities. There are several reports in the literature concerning the effects of acute experimental pain on motor control. However, a more heterogeneous picture exists in the literature with respect to whether chronic pain conditions affect motor control.This study compares firing rate and conduction velocity (CV) of single motor units (MUs) in the trapezius muscle of fibromyalgia patients (FM) and healthy controls (CON). Multi-channel surface electromyography was used to estimate both MU firing rate and CV because this technique allows simultaneous estimation of both these variables and the measurements are easy and non-invasive. In this study, 29 FM and 30 CON subjects participated and performed isometric shoulder elevations using weights up to 4 kg. No significant differences in the firing rate of MUs in the trapezius muscle were found between the FM and CON groups (95% confidence interval was −1.9 and 1.3 pulses per second). There were no significant differences in CV between the groups at 1 and 2 kg load. However, the FM group had significantly higher CV in contractions without external load (p = 0.004).We were unable to confirm the pain-adaptation model since no differences in firing rate between the two groups were found. CV was significantly higher in FM than in healthy controls; this might be due to alterations in histopathology and microcirculation.  相似文献   

11.
Two experiments were conducted to examine effects of muscle fatigue on motor-unit synchronization of quadriceps muscles (rectus femoris, vastus medialis, vastus lateralis) within and between legs. We expected muscle fatigue to result in an increased common drive to different motor units of synergists within a leg and, hence, to increased synchronization, i.e., an increased coherence between corresponding surface EMGs. We further expected fatigue-related motor overflow to cause motor-unit synchronization of homologous muscles of both legs, although to a lesser extent than for synergists within a leg. In the first experiment, different levels of fatigue were induced by varying posture (knee angle), whereas in the second experiment fatigue was induced in a fixed posture by instructing participants to produce different force levels. EMG coherence was found in two distinct frequency bands (6–11 and 13–18 Hz) and was higher within a leg than between legs. The fatigue-related increase of 6–11 Hz inter-limb synchronization resembled the increased motor overflow during unimanual contractions and thus hinted at an increase in bilateral coupling. Synchronization at 13–18 Hz was clearly different and appeared to be related to posture.  相似文献   

12.
The purpose of this study was to use a wavelet-based signal processing technique to examine the influence of electrode placement over the innervation zone (IZ) on the shape of the electromyographic (EMG) frequency spectrum. Ten healthy males (mean ± SD age = 23.6 ± 3.0 years) performed isometric muscle actions of the dominant leg extensors at 10%, 40%, 70%, and 100% of the maximum voluntary contraction (MVC). Surface EMG signals were detected simultaneously from the vastus lateralis with two bipolar electrode arrangements. One of the electrode arrangements had its center point located directly over the IZ, while the other arrangement had its center point distal to the IZ (i.e., 20 mm away). All EMG signals were processed with a wavelet-based procedure. The results showed that for all isometric torque levels, the EMG signals from the distal electrode arrangement demonstrated greater total intensity values than those for the IZ arrangement for frequencies ranging from approximately 2 to 110 Hz. There were no consistent differences, however, between the IZ and distal electrode arrangements for total EMG intensity values above 110 Hz. Thus, these findings indicated that electrode placement over the IZ affected primarily the low-, rather than the high-frequency portion of the EMG frequency spectrum.  相似文献   

13.
Motor unit behavior differs between contraction types at submaximal contraction levels, however is challenging to study during maximal voluntary contractions (MVCs). With multi-channel surface electromyography (sEMG), mean physiological characteristics of the active motor units can be extracted. Two 8-electrode sEMG arrays were attached on biceps brachii muscle (one on each head) to examine behavior of sEMG variables during isometric, eccentric and concentric MVCs of elbow flexors in 36 volunteers.On average, isometric (364 ± 88 N) and eccentric (353 ± 74 N) MVCs were higher than concentric (290 ± 73 N) MVC (p < 0.001). Mean muscle fiber conduction velocity (CV) was highest during eccentric MVC (4.42 ± 0.49 m/s) than concentric (4.25 ± 0.49 m/s, p < 0.01) and isometric (4.14 ± 0.45 m/s, p < 0.001) MVCs. Furthermore, eccentric MVC showed lower sEMG amplitude at the largest elbow joint angles (120–170°) and higher CV at the smallest (70–150°) elbow joint angles (p < 0.05–0.001) than concentric MVC.The differences in CV and sEMG amplitude between the MVCs suggest that the control strategy of motor units differs between the contraction types during MVCs, and is dependent on the muscle length between the dynamic MVCs.  相似文献   

14.
The central- and peripheral mechanisms by which heat strain limits physical performance are not fully elucidated. Nevertheless, pre-cooling is often used in an attempt to improve subsequent performance. This study compared the effects of pre-cooling vs. a pre-thermoneutral application on central- and peripheral fatigue during 60% of isometric maximum voluntary contraction (MVC) of the right quadriceps femoris muscle. Furthermore, the effects between a pre-cooling and a pre-thermoneutral application on isometric MVC of the right quadriceps femoris muscle and subjective ratings of perceived exertion (RPE) were investigated. In this randomized controlled trial, 18 healthy adults voluntarily participated. The participants received either a cold (experimental) application (+8 °C) or a thermoneutral (control) application (+32 °C) for 20 min on their right thigh (one cuff). After the application, central (fractal dimension – FD) and peripheral (muscle fiber conduction velocity – CV) fatigue was estimated using sEMG parameters during 60% of isometric MVC. Surface EMG signals were detected from the vastus medialis and lateralis using bidimensional arrays. Immediately after the submaximal contraction, isometric MVC and RPE were assessed. Participants receiving the cold application were able to maintain a 60% isometric MVC significantly longer when compared to the thermoneutral group (mean time: 78 vs. 46 s; p=0.04). The thermoneutral application had no significant impact on central fatigue (p>0.05) compared to the cold application (p=0.03). However, signs of peripheral fatigue were significantly higher in the cold group compared to the thermoneutral group (p=0.008). Pre-cooling had no effect on isometric MVC of the right quadriceps muscle and ratings of perceived exertion. Pre-cooling attenuated central fatigue and led to significantly longer submaximal contraction times compared to the pre-thermoneutral application. These findings support the use of pre-cooling procedures prior to submaximal exercises of the quadriceps muscle compared to pre-thermoneutral applications.  相似文献   

15.
High-density surface electromyography was used to examine whether gross sarcolemmal function is impaired in m. biceps brachii after intensive eccentric elbow flexor exercise, when measured at wide range of isometric contraction levels.Root mean square (RMS), mean power frequency (MNF) and mean muscle fibre conduction velocity (CV) were calculated before and up to four days post-exercise.Maximal isometric voluntary (MVC) force decreased by 21.3 ± 5.6% two hours after exercise, and by 12.6 ± 11.1% two days post-exercise. CV and MNF decreased both during MVC (CV from 4.1 ± 0.3 m/s to 3.8 ± 0.4 m/s and MNF from 92.6 ± 10 Hz to 85.2 ± 11 Hz) and during electrically evoked maximal M-wave (CV from 4.1 ± 0.3 m/s to 3.0 ± 0.5 m/s and MNF from 97.1 ± 27.2 Hz to 78.0 ± 24.4 Hz) two hours post-exercise. Furthermore, at submaximal isometric force levels, CV and MNF decreased only at higher contraction levels (40%, 50% and 75% of MVC) two hour post-exercise.It can be concluded that intensive exercise can temporarily impair gross sarcolemmal function. In addition, since this only occurred at high force levels, based on Henneman’s size principle, it seems that higher threshold motor units were predominantly affected.  相似文献   

16.
The purpose of the present study was to examine the patterns of responses for torque, electromyographic (EMG) amplitude, EMG mean power frequency (MPF), mechanomyographic (MMG) amplitude, and MMG MPF across 30 repeated maximal isometric (ISO) and concentric (CON) muscle actions of the leg extensors. Twelve female subjects (21.1 ± 1.4 yrs; 63.3 ± 7.4 kg) performed ISO and CON fatigue protocols with EMG and MMG signals recorded from the vastus lateralis. The relationships for torque, EMG amplitude, EMG MPF, MMG amplitude, and MMG MPF versus repetition number were examined using polynomial regression. The results indicated there were decreases (p < 0.05) across the ISO muscle actions for torque (r2 = 0.95), EMG amplitude (R2 = 0.44), EMG MPF (r2 = 0.62), and MMG MPF (r2 = 0.48), but no change in MMG amplitude (r2 = 0.07). In addition, there were decreases across the CON muscle actions for torque (R2 = 0.97), EMG amplitude (R2 = 0.46), EMG MPF (R2 = 0.86), MMG amplitude (R2 = 0.44), and MMG MPF (R2 = 0.80). Thus, the current findings suggested that the mechanisms of fatigue and motor control strategies used to modulate torque production were similar between maximal ISO and CON muscle actions.  相似文献   

17.
Assessment of intra-session repeatability of muscle activation pattern is of considerable relevance for research settings, especially when used to determine changes over time. However, the repeatability of lower limb muscles activation pattern during pedaling is not fully established. Thus, we tested the intra-session repeatability of the activation pattern of 10 lower limb muscles during a sub-maximal cycling exercise.Eleven triathletes participated to this study. The experimental session consisted in a reference sub-maximal cycling exercise (i.e. 150 W) performed before and after a 53-min simulated training session (mean power output = 200 ± 12 W). Repeatability of EMG patterns was assessed in terms of muscle activity level (i.e. RMS of the mean pedaling cycle and burst) and muscle activation timing (i.e. onset and offset of the EMG burst) for the 10 following lower limb muscles: gluteus maximus (GMax), semimembranosus (SM), Biceps femoris (BF), vastus medialis (VM), rectus femoris (RF), vastus lateralis (VL), gastrocnemius medianus (GM) and lateralis (GL), soleus (SOL) and tibialis anterior (TA).No significant differences concerning the muscle activation level were found between test and retest for all the muscles investigated. Only VM, SOL and TA showed significant differences in muscle activation timing parameters. Whereas ICC and SEM values confirmed this weak repeatability, cross-correlation coefficients suggest a good repeatability of the activation timing parameters for all the studied muscles.Overall, the main finding of this work is the good repeatability of the EMG pattern during pedaling both in term of muscle activity level and muscle activation timing.  相似文献   

18.
The value of electromyography (EMG) is sensitive to many physiological and non-physiological factors. The purpose of the present study was to determine if the torque–velocity test (T–V) can be used to normalize EMG signals into a framework of biological significance. Peak EMG amplitude of gluteus maximus (GMAX), vastus lateralis (VL), rectus femoris (RF), biceps femoris long head (BF), gastrocnemius medialis (GAS) and soleus (SOL) was calculated for nine subjects during isometric maximal voluntary contractions (IMVC) and torque–velocity bicycling tests (T–V). Then, the reference EMG signals obtained from IMVC and T–V bicycling tests were used to normalize the amplitude of the EMG signals collected for 15 different submaximal pedaling conditions. The results of this study showed that the repeatability of the measurements between IMVC (from 10% to 23%) and T–V (from 8% to 20%) was comparable. The amplitude of the peak EMG of VL was 99 ± 43% higher (p < 0.001) when measured during T–V. Moreover, the inter-individual variability of the EMG patterns calculated for submaximal cycling exercises differed significantly when using T–V bicycling normalization method (GMAX: 0.33 ± 0.16 vs. 1.09 ± 0.04, VL: 0.07 ± 0.02 vs. 0.64 ± 0.14, SOL: 0.07 ± 0.03 vs. 1.00 ± 0.07, RF: 1.21 ± 0.20 vs. 0.92 ± 0.13, BF: 1.47 ± 0.47 vs. 0.84 ± 0.11). It was concluded that T–V bicycling test offers the advantage to be less time and energy-consuming and to be as repeatable as IMVC tests to measure peak EMG amplitude. Furthermore, this normalization method avoids the impact of non-physiological factors on the amplitude of the EMG signals so that it allows quantifying better the activation level of lower limb muscles and the variability of the EMG patterns during submaximal bicycling exercises.  相似文献   

19.
The influence of the knee flexion on muscle activation and transmissibility during whole body vibration is controversially discussed in the literature. In this study, 34 individuals had electromyography activity (EMG) of the vastus lateralis and the acceleration assessed while squatting with 60° and 90° of knee flexion either with or without whole-body vibration (WBV). The conditions were maintained for 10 s with 1 min of rest between each condition. The main findings were (1) the larger the angle of knee flexion (90° vs. 60°), the greater the EMG (p < 0.001), with no difference on acceleration transmissibility; (2) for both angles of knee flexion, the addition of WBV produced no significant difference in EMG and higher acceleration compared to without WBV (p < 0.001). These results suggest that the larger the knee flexion angle (60° vs. 90°), the greater the muscle activation without acceleration modification. However, the addition of WBV increases the transmissibility of acceleration in the lower limbs without modification in EMG of vastus lateralis.  相似文献   

20.
The aims of this study were to examine if surface EMG signals can be detected from the quadriceps femoris muscle of severely obese patients and to investigate if differences exist in quadriceps force and myoelectric manifestations of fatigue between obese patients and lean controls.Fourteen severely obese patients (body mass index, BMI, mean ± SD: 44.9 ± 6.3 kg/m2) and fourteen healthy controls (BMI: 23.7 ± 2.5 kg/m2) were studied. The vastus medialis and lateralis of the dominant thigh were concurrently investigated during voluntary isometric contractions (10-s long at submaximal and maximal intensities and intermittent submaximal contractions until exhaustion) and sustained (120-s long) electrically elicited contractions.We found that the detection of surface EMG signals from the quadriceps is feasible also in severely obese subjects presenting increased thickness of the subcutaneous fat tissue. In addition, we confirmed and extended previous findings showing that the volume conductor properties determine the amplitude and spectral features of the detected surface EMG signals: the lower the subcutaneous tissue thickness, the higher the amplitude and mean frequency estimates. Further, we found no differences in the mechanical and myoelectric manifestations of fatigue during intermittent voluntary and sustained electrically elicited contractions between obese patients and lean controls.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号