首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An impedance biosensor based on interdigitated array microelectrode (IDAM) coupled with magnetic nanoparticle-antibody conjugates (MNAC) was developed and evaluated for rapid and specific detection of E. coli O157:H7 in ground beef samples. MNAC were prepared by immobilizing biotin-labeled polyclonal goat anti-E. coli antibodies onto streptavidin-coated magnetic nanoparticles, which were used to separate and concentrate E. coli O157:H7 from ground beef samples. Magnitude of impedance and phase angle were measured in a frequency range of 10 Hz to 1 MHz in the presence of 0.1M mannitol solution. The lowest detection limits of this biosensor for detection of E. coli O157:H7 in pure culture and ground beef samples were 7.4 x 10(4) and 8.0 x 10(5)CFU ml(-1), respectively. The regression equation for the normalized impedance change (NIC) versus E. coli O157:H7 concentration (N) in ground beef samples was NIC=15.55 N-71.04 with R(2)=0.95. Sensitivity of the impedance biosensor was improved by 35% by concentrating bacterial cells attached to MNAC in the active layer of IDAM above the surface of electrodes with the help of a magnetic field. Based on equivalent circuit analysis, it was observed that bulk resistance and double layer capacitance were responsible for the impedance change caused by the presence of E. coli O157:H7 on the surface of IDAM. Surface immobilization techniques, redox probes, or sample incubation were not used in this impedance biosensor. The total detection time from sampling to measurement was 35 min.  相似文献   

2.
A solid phase fluorescence-based immunoassay was developed for the detection of Escherichia coli O157:H7 using an antigen down competition format. A soft glass capillary tube served as the solid support, to which heat-killed E. coli O157:H7 were adsorbed. Polyclonal anti- E. coli O157:H7 antibody, conjugated with biotin, was used and the bound antigen-antibody complex was detected using avidin molecules labelled with Cy5, a fluorescent cyanine dye. Any E. coli O157:H7 in the sample would compete with the formation of this complex, reducing fluorescence. This assay was tested for sensitivity with spiked ground beef and apple cider samples. The minimum detectable number of cells present in the initial inoculum was calculated to be approximately 1 colony-forming unit (cfu) per 10g of ground beef when samples were enriched in modified EC broth for 7 h at 37°C. The minimum detectable number of cells for the apple cider samples was calculated to be ∼0.5 cfu ml-1 The E. coli cells in the cider samples were captured with immunomagnetic beads, incubated for 7 h in the enrichment broth, and detected with the solid phase fluorescence immunoassay.  相似文献   

3.
A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be detected within 16 h, including incubation for 12 h in enrichment broth and the immunoassay, which takes 4 h. Pure culture cell suspensions of 10(5) or 10(6) E. coli O157:H7 organisms per ml produced intense color reactions in the immunoassay, whereas faint but detectable reactions occurred with 10(3) CFU/ml. The sensitivity of the combined enrichment-immunoassay procedure as determined by using ground beef inoculated with E. coli O157:H7 was 0.1 to 1.3 cells per g, with a false-positive rate of 2.0%. A survey of retail ground beef using this procedure revealed that 1 of 76 samples was contaminated by E. coli O157:H7.  相似文献   

4.
A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be detected within 16 h, including incubation for 12 h in enrichment broth and the immunoassay, which takes 4 h. Pure culture cell suspensions of 10(5) or 10(6) E. coli O157:H7 organisms per ml produced intense color reactions in the immunoassay, whereas faint but detectable reactions occurred with 10(3) CFU/ml. The sensitivity of the combined enrichment-immunoassay procedure as determined by using ground beef inoculated with E. coli O157:H7 was 0.1 to 1.3 cells per g, with a false-positive rate of 2.0%. A survey of retail ground beef using this procedure revealed that 1 of 76 samples was contaminated by E. coli O157:H7.  相似文献   

5.
The efficacy of tryptic soy agar (TSA), modified sorbitol MacConkey agar (MSMA), modified eosin methylene blue (MEMB) agar, and modified SD-39 (MSD) agar in recovering a five-strain mixture of enterohemorrhagic Escherichia coli O157:H7 and five non-O157 strains of E. coli heated in tryptic soy broth at 52, 54, or 56 degrees C for 10, 20, and 30 min was determined. Nonselective TSA supported the highest recovery of heated cells. Significantly (P < or = 0.05) lower recovery of heat-stressed cells was observed on MSMA than on TSA, MEMB agar, or MSD agar. The suitability of MEMB agar or MSD agar for recovery of E. coli O157:H7 from heated or frozen (-20 degrees C) low- or high-fat ground beef was determined. Recovery of E. coli O157:H7 from heated ground beef was significantly (P < or = 0.05) higher on TSA than on MEMB agar, which in turn supported higher recovery than MSD agar did; MSMA was inferior. Recovery from frozen ground beef was also higher on MEMB and MSD agars than on MSMA. Higher populations were generally recovered from high-fat beef than from low-fat beef, but the relative performance of the recovery media was the same. The inability of MSMA to recover stressed cells of E. coli O157:H7 underscores the need to develop a better selective medium for enumerating E. coli O157:H7.  相似文献   

6.
AIM: To develop and validate high throughput methods for the direct enumeration of viable and culturable Salmonella and Escherichia coli O157:H7 in ground beef, carcass, hide and faecal (GCHF) samples from cattle. METHODS AND RESULTS: The hydrophobic grid membrane filtration (HGMF) method and the spiral plate count method (SPCM) were evaluated as rapid tools for the estimation of pathogen load using GCHF samples spiked with known levels of Salmonella serotype Typhimurium. Validation studies showed that for a single determination of each sample type the low end of the detection limits were approx. 2.0 x 10(0) CFU g(-1) for ground beef, 5.0 x 10(-1) CFU (100 cm(2))(-1) for Salmonella and 8.0 x 10(-1) CFU (100 cm(2))(-1) for E. coli O157:H7 on carcasses, 4.0 x 10(1) CFU (100 cm(2))(-1) for hide and 2.0 x 10(2) CFU g(-1) for faecal samples. In addition, ground beef (n = 609), carcass (n = 1520) and hide (n = 3038) samples were collected from beef-processing plants and faecal samples (n = 3190) were collected from feed-lot cattle, and these samples were tested for the presence of Salmonella and E. coli O157:H7 by enrichment and enumeration methods. CONCLUSIONS: The direct enumeration methods described here are amenable to high throughput sample processing and were found to be cost-effective alternatives to other enumeration methods for the estimation of Salmonella and E. coli O157:H7, in samples collected during cattle production and beef processing. SIGNIFICANCE AND IMPACT OF THE STUDY: Use of the methods described here would allow for more routine testing and quantification data collection, providing useful information about the effectiveness of beef processing intervention strategies.  相似文献   

7.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

8.
Escherichia coli O157:H7 in ground beef was more sensitive to heat than salmonellae, but survived for 9 months at -20 degrees C with little change in number. The organisms grew well in Trypticase soy broth (BBL Microbiology Systems) between 30 and 42 degrees C, with 37 degrees C being optimal for growth. E. coli O157:H7 grew poorly in the temperature range (44 to 45.5 degrees C) generally used for recovery of E. coli from foods.  相似文献   

9.
A potential may exist for survival of and resistance development by Escherichia coli O157:H7 in environmental niches of meat plants applying carcass decontamination interventions. This study evaluated (i) survival or growth of acid-adapted and nonadapted E. coli O157:H7 strain ATCC 43895 in acetic acid (pH 3.6 +/- 0.1) or in water (pH 7.2 +/- 0.2) fresh beef decontamination runoff fluids (washings) stored at 4, 10, 15, or 25 degrees C and (ii) resistance of cells recovered from the washings after 2 or 7 days of storage to a subsequent lactic acid (pH 3.5) stress. Corresponding cultures in sterile saline or in heat-sterilized water washings were used as controls. In acetic acid washings, acid-adapted cultures survived better than nonadapted cultures, with survival being greatest at 4 degrees C and lowest at 25 degrees C. The pathogen survived without growth in water washings at 4 and 10 degrees C, while it grew by 0.8 to 2.7 log cycles at 15 and 25 degrees C, and more in the absence of natural flora. E. coli O157:H7 cells habituated without growth in water washings at 4 or 10 degrees C were the most sensitive to pH 3.5, while cells grown in water washings at 15 or 25 degrees C were relatively the most resistant, irrespective of previous acid adaptation. Resistance to pH 3.5 of E. coli O157:H7 cells habituated in acetic acid washings for 7 days increased in the order 15 degrees C > 10 degrees C > 4 degrees C, while at 25 degrees C cells died off. These results indicate that growth inhibition by storage at low temperatures may be more important than competition by natural flora in inducing acid sensitization of E. coli O157:H7 in fresh meat environments. At ambient temperatures in meat plants, E. coli O157:H7 may grow to restore acid resistance, unless acid interventions are applied to inhibit growth and minimize survival of the pathogen. Acid-habituated E. coli O157:H7 at 10 to 15 degrees C may maintain a higher acid resistance than when acid habituated at 4 degrees C. These responses should be evaluated with fresh meat and may be useful for the optimization of decontamination programs and postdecontamination conditions of meat handling.  相似文献   

10.
AIM: To develop an improved, rapid and sensitive sample preparation method for PCR-based detection of Escherichia coli O157:H7 in ground beef. METHODS AND RESULTS: Fresh ground beef samples were experimentally inoculated with varying concentrations of E. coli O157:H7. PCR inhibitors were removed and bacterial cells were concentrated by filtration and centrifugation, and lysed using enzymatic digestion and successive freeze/thaw cycles. DNA was purified and concentrated via phenol/chloroform extraction and the Shiga toxin 1 gene (stx1) was amplified using PCR to evaluate the sample preparation method. Without prior enrichment of cells in broth media, the detection limit was 103 CFU g-1 beef. When a 6 h enrichment step was incorporated, the detection limit was 1 CFU g-1 beef. The total time required from beginning to end of the procedure was 12 h. CONCLUSIONS: The sample preparation method developed here enabled substantially improved sensitivity in the PCR-based detection of E. coli O157:H7 in ground beef, as compared to previous reports. SIGNIFICANCE AND IMPACT OF THE STUDY: Superb sensitivity, coupled with quick turn-around time, relative ease of use and cost-effectiveness, makes this a useful method for detecting E. coli O157:H7 in ground beef.  相似文献   

11.
AIMS: The effect of a lactic acid producing bacterial (LAB) inoculant on the elimination of Escherichia coli O157:H7 from barley forage was assessed. METHODS AND RESULTS: Triplicate mini-silos were prepared for four treatments and six sampling times (1, 3, 7, 15, 30 and 42 d post-ensiling). The treatments were (i) 10(5) cfu g(-1) Pediococcus pentosaceus and Propionibacterium jenzenii (P2); (ii) 10(5) cfu g(-1) E. coli O157:H7 strain 3081 and 10(5) cfu g(-1) E. coli Biotype 1 strains 719IE10, 719IE14 and 614ME49 (EC); (iii) P2 + EC; and (iv) the control (sterile distilled water). Triplicate mini-silos were opened at each sampling time for pH, volatile fatty acid (VFA) and lactate determinations and E. coli, E. coli O157:H7 and LAB were enumerated. On d 3 and 7, numbers of E. coli O157:H7 in P2 + EC were significantly lower than in EC (P < 0;05). Escherichia coli O157:H7 was not detected in P2 + EC and EC at 7 and 15 d post-ensiling, respectively. On d 15 through 42, E. coli Biotype 1 was not detected in P2 + EC or EC. Populations of LAB were higher in P2 and P2 + EC than in the control and EC on d 3 and 7 (P < 0.05). After 3 d of ensiling, lactate levels were higher (P < 0.05) and pH was lower (P < 0.05) in P2 and P2 + EC as compared to the control and EC. Bacteriocins of P2 were not found to be inhibitory to E. coli O157:H7 using the agar-spot procedure. Escherichia coli O157:H7 inoculated into the control silage at a level of 10(3) cfu g(-1) and exposed to aerobic conditions at 22 degrees C was not detected after 1 d and remained undetectable for the 28 d exposure period. CONCLUSIONS: Silage inoculant P2 increased lactate levels and decreased pH more rapidly during ensiling, which appeared to hasten the elimination of E. coli O157:H7 from the silage. SIGNIFICANCE AND IMPACT OF THE STUDY: Results emphasize the importance of adequate ensiling since E. coli O157:H7 may be maintained and spread among cattle through feed.  相似文献   

12.
There was no significant difference (P > 0.05) in the percentages of Escherichia coli O157:H7 cells recovered on BCM O157:H7 (+) agar (69.7%) and MacConkey sorbitol agar containing 5-bromo-4-chloro-3-indoxyl-beta-D-glucuronic acid (MSA-BCIG) (76.8%) vs Tryptic soy agar. Three E. coli O157:H7 strains (ATCC 35150, 43890 and 43894) were separately inoculated into raw ground beef at low (mean 0.32 cfu g-1) and high (mean 3.12 cfu g-1) levels. Using the United States Department of Agriculture (USDA) m-EC + novobiocin enrichment broth, BCM O157:H7 (+) medium surpassed MSA-BCIG agar with overall percentage sensitivities for BCM O157:H7 (+) of 92.1 and 94.4 compared with 52.6 and 84.7 for MSA-BCIG at low and high levels, respectively. A comparison of BCM O157:H7 (+) and MSA-BCIG agars using naturally contaminated beef samples was made utilizing presumptively positive enrichment broths previously identified by rapid methods. The E. coli O157:H7 cells in these broths were concentrated with Dynabeads anti-E. coli O157 before inoculating the agars. The respective percentage sensitivity and specificity values were 90.0 and 78.5 for BCM O157:H7 (+) and 70.0 and 46.4 for MSA-BCIG. Thus, under identical pre-plating conditions, BCM O157:H7 (+) medium displayed a greater sensitivity than MSA-BCIG for detecting E. coli O157:H7 in artificially inoculated beef, and both greater sensitivity and specificity upon examining naturally contaminated beef samples.  相似文献   

13.
Human disease caused by Escherichia coli O157:H7 is a function of the number of cells that are present at potential sites of infection and host susceptibility. Such infectious doses are a result, in part, of the quantity of cells that are ingested and that survive human host defenses, such as the low-pH environment of the stomach. To more fully understand the kinetics of E. coli O157:H7 survival in gastric fluid, individual E. coli O157:H7 strains were suspended in various media (i.e., saline, cooked ground beef [CGB], and CGB containing a commercial antacid product [CGB+A]), mixed at various proportions with simulated human gastric fluid (SGF), and then incubated at 37 degrees C for up to 4 h. The highest inactivation rate among nine E. coli O157:H7 strains was observed in saline. Specifically, the average survival rates in 100:1 and 10:1 proportions of SGF-saline were -1.344 +/- 0.564 and -0.997 +/- 0.388 log(10) CFU/h, respectively. In contrast, the average inactivation rate for 10 E. coli O157:H7 strains suspended in 10:1 SGF-CGB was -0.081 +/- 0.068, a rate that was 12-fold lower than that observed for SGF-saline. In comparison, the average inactivation rate for Shigella flexneri strain 5348 in 100:1 and 10:1 SGF-saline was -8.784 and -17.310, respectively. These latter inactivation rates were 7- to 17-fold higher than those for E. coli O157:H7 strains in SGF-saline and were 4-fold higher than those for E. coli O157:H7 strains in SGF-CGB. The survival rate of E. coli O157:H7 strain GFP80EC increased as the dose of antacid increased from one-half to twice the prescribed dose. A similar trend was observed for the matrix pH over the range of pH 1.6 to 5.7, indicating that pH is a primary factor affecting E. coli O157:H7 survival in SGF-CGB+A. These results can be used in risk assessment to define dose-response relationships for E. coli O157:H7 and to evaluate potential surrogate organisms.  相似文献   

14.
We found effective enrichment procedures for detecting Escherichia coli O26 in foods using methods that are used for E. coli O157. Ground beef or radish sprouts inoculated with approximately 6 colony-forming units of E. coli O26 were homogenized in 225 ml of various broths. After static incubation at 37 degrees C or 42 degrees C for 6 h or 18 h, we isolated the inoculated bacterium by plating onto Rainbow Agar O157 with novobiocin. In combination with the immunomagnetic separation method, E. coli O26 was isolated from all samples by using enrichment in tryptone soy broth at 37 degrees C for 6 h and in modified E. coli broth with novobiocin (mEC + n) at 42 degrees C for 18 h in ground beef and radish sprouts, respectively. Enrichment in mEC + n at 42 degrees C for 18 h was effective for isolating both E. coli O26 and E. coli O157 from both ground beef and radish sprouts.  相似文献   

15.
A sensitive, specific procedure was developed for detecting Escherichia coli O157:H7 in food in less than 20 h. The procedure involves enrichment of 25 g of food in 225 ml of a selective enrichment medium for 16 to 18 h at 37 degrees C with agitation (150 rpm). The enrichment culture is applied to a sandwich enzyme-linked immunosorbent assay (ELISA) with a polyclonal antibody specific for E. coli O157 antigen as the capture antibody and a monoclonal antibody specific for enterohemorrhagic E. coli of serotypes O157:H7 and O26:H11 as the detection antibody. The ELISA can be completed within 3 h. The sensitivity of the procedure, determined by using E. coli O157:H7-inoculated ground beef and dairy products, including different varieties of cheese, was 0.2 to 0.9 cell per g of food. A survey of retail fresh ground beef and farm raw milk samples with this procedure revealed that 3 (2.8%) of 107 ground beef samples and 11 (10%) of 115 raw milk samples were positive for E. coli O157:H7. Most-probable-number determinations revealed E. coli O157:H7 populations of 0.4 to 1.5 cells per g in the three ground beef samples. In addition to being highly specific, sensitive, and rapid, this procedure is easy to perform and is amenable to use by laboratories performing routine microbiological testing.  相似文献   

16.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0. 95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

17.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

18.
Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.  相似文献   

19.
AIMS: To determine the prevalence of four bacterial zoonotic pathogens in beef cattle at time of slaughter in Northern Ireland (NI), in order to assess their potential for reducing beef safety. METHODS AND RESULTS: Faeces were collected postmortem from beef cattle (n =220) at seven EU registered abattoirs. Standard enrichment culturing methods were employed, plus immunomagnetic enrichment in the case of Escherichia coli O157:H7. Campylobacter spp. were found in 52 samples (24.8%), Listeria monocytogenes in 10 (4.8%), E. coli O157:H7 in 2 (0.9%) whilst Salmonella spp. were isolated from six out of 200 samples (3.0%). Five salmonellas were Salmonella Chandans and one was Salmonella Liverpool. CONCLUSIONS: Campylobacter spp. were the most frequently isolated pathogen, despite being relatively rare in beef. Genotyping showed the campylobacters to be very diverse, indicating cattle encounter campylobacters from many sources. The remaining three pathogens, which are associated with meats, occurred at relatively low frequencies, especially E. coli O157:H7. The Salmonella serovars found rarely infect humans. SIGNIFICANCE AND IMPACT OF THE STUDY: The low prevalence of E. coli O157:H7 in NI beef cattle was confirmed and the reasons for this merit further study. The four pathogens should have little impact on beef quality.  相似文献   

20.
Gallbladders and rectal contents were collected from cattle (n=933) at slaughter to determine whether the gallbladder harbors Escherichia coli O157:H7. Both gallbladder mucosal swabs and homogenized mucosal tissues were used for isolation. Only five gallbladders (0.54%) were positive for E. coli O157:H7. Fecal prevalence averaged 7.1%; however, none of the cattle that had E. coli O157:H7 in the gallbladder was positive for E. coli O157:H7 in feces. Therefore, the gallbladder does not appear to be a common site of colonization for E. coli O157:H7 in beef cattle.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号