首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 968 毫秒
1.
Rapid, direct methods are needed to assess active bacterial populations in water and foods. Our objective was to determine the efficiency of bacterial detection by immunomagnetic separation (IMS) and the compatibility of IMS with cyanoditolyl tetrazolium chloride (CTC) incubation to determine respiratory activity, using the pathogen Escherichia coli O157:H7. Counterstaining with a specific fluorescein-conjugated anti-O157 antibody (FAb) following CTC incubation was used to allow confirmation and visualization of bacteria by epifluorescence microscopy. Broth-grown E. coli O157:H7 was used to inoculate fresh ground beef (<17% fat), sterile 0.1% peptone, or water. Inoculated meat was diluted and homogenized in a stomacher and then incubated with paramagnetic beads coated with anti-O157 specific antibody. After IMS, cells with magnetic beads attached were stained with CTC and then an anti-O157 antibody-fluorescein isothiocyanate conjugate and filtered for microscopic enumeration or solid-phase laser cytometry. Enumeration by laser scanning permitted detection of ca. 10 CFU/g of ground beef or <10 CFU/ml of liquid sample. With inoculated meat, the regression results for log-transformed respiring FAb-positive counts of cells recovered on beads versus sorbitol-negative plate counts in the inoculum were as follows: intercept = 1.06, slope = 0.89, and r2 = 0.95 (n = 13). The corresponding results for inoculated peptone were as follows: intercept = 0.67, slope = 0.88, and r2 = 0.98 (n = 24). Recovery of target bacteria on beads by the IMS-CTC-FAb method, compared with recovery by sorbitol MacConkey agar plating, yielded greater numbers (beef, 6.0 times; peptone, 3.0 times; water, 2.4 times). Thus, within 5 to 7 h, the IMS-CTC-FAb method detected greater numbers of E. coli O157 cells than were detected by plating. The results show that the IMS-CTC-FAb technique with enumeration by either fluorescence microscopy or solid-phase laser scanning cytometry gave results that compared favorably with plating following IMS.  相似文献   

2.
AIMS: To compare media used in immunomagnetic separation (IMS) techniques for the isolation of Escherichia coli O157 from food. METHODS AND RESULTS: Foods, both naturally contaminated and spiked, with low numbers (< 1 g(-1)) of stressed E. coli O157 were enriched in media based on buffered peptone water (BPW), tryptone soya and EC broths incubated at 30, 37, 40 and 42 degrees C. Following immunomagnetic separation, beads were plated on a range of selective agars. CONCLUSION: BPW supplemented with vancomycin (8 mg l(-1)) incubated at 42 degrees C, followed by IMS and subsequent plating of immunobeads onto cefixime tellurite sorbitol MacConkey agar plus either Rainbow or CHROMagar agars, proved optimum for the recovery of spiked, stressed E. coli O157 in minced beef, cheese, apple juice and pepperoni. The same protocol was optimum for recovery from naturally-contaminated minced beef and cheese. SIGNIFICANCE AND IMPACT OF THE STUDY: The optimum protocol would increase isolation rates of E. coli O157 from foods.  相似文献   

3.
AIMS: To assess the detection and recovery rates achieved with commonly used cultural methods for the enumeration and recovery of Escherichia coli O157:H7 from minced beef and bovine hide. METHODS AND RESULTS: Minced beef and bovine hide were inoculated with varying concentrations (log(10) 1.58-2.58 CFU g(-1) and log(10) 2.42-4.49 CFU 100 cm(2) respectively) of E. coli O157:H7 and recovered using a direct plate method or an enrichment/immunomagnetic separation (IMS) method and then plated onto SMAC or SMAC-CT in both cases. The direct plate method detected the pathogen consistently from minced beef samples with an average recovery of 69.2-91.2%. From faecal material on the bovine hide the recovery of the pathogen ranged from 1.80 to 64.5% with fresh faeces depending on the inocula while from dried faeces on hide the results ranged from no recovery at all to 25.1%. Enrichment/IMS recovered E. coli O157:H7 at all inocula levels tested in minced beef while the pathogen was only detected consistently at an average inocula level of log(10) 2.73 CFU 100 cm(2) from fresh faeces and log(10) 4.49 CFU 100 cm(2) from dried faeces on bovine hide. CONCLUSIONS: The direct count enumeration method for E. coli O157:H7 underestimated the numbers of pathogens present. The enrichment/IMS procedure consistently detected the pathogen from minced beef but did not always detect E. coli O157:H7 from faeces on bovine hide. SIGNIFICANCE AND IMPACT OF THE STUDY: Overall this study highlights that any microbial data, used in either predictive microbiology or risk assessment, must take account of the sensitivity and associated performance of the methods employed, in order to make an accurate reflection of the true microbiology of the examined sample.  相似文献   

4.
AIM: To develop and validate high throughput methods for the direct enumeration of viable and culturable Salmonella and Escherichia coli O157:H7 in ground beef, carcass, hide and faecal (GCHF) samples from cattle. METHODS AND RESULTS: The hydrophobic grid membrane filtration (HGMF) method and the spiral plate count method (SPCM) were evaluated as rapid tools for the estimation of pathogen load using GCHF samples spiked with known levels of Salmonella serotype Typhimurium. Validation studies showed that for a single determination of each sample type the low end of the detection limits were approx. 2.0 x 10(0) CFU g(-1) for ground beef, 5.0 x 10(-1) CFU (100 cm(2))(-1) for Salmonella and 8.0 x 10(-1) CFU (100 cm(2))(-1) for E. coli O157:H7 on carcasses, 4.0 x 10(1) CFU (100 cm(2))(-1) for hide and 2.0 x 10(2) CFU g(-1) for faecal samples. In addition, ground beef (n = 609), carcass (n = 1520) and hide (n = 3038) samples were collected from beef-processing plants and faecal samples (n = 3190) were collected from feed-lot cattle, and these samples were tested for the presence of Salmonella and E. coli O157:H7 by enrichment and enumeration methods. CONCLUSIONS: The direct enumeration methods described here are amenable to high throughput sample processing and were found to be cost-effective alternatives to other enumeration methods for the estimation of Salmonella and E. coli O157:H7, in samples collected during cattle production and beef processing. SIGNIFICANCE AND IMPACT OF THE STUDY: Use of the methods described here would allow for more routine testing and quantification data collection, providing useful information about the effectiveness of beef processing intervention strategies.  相似文献   

5.
The potentially low infective dose of Escherichia coli O157 makes it necessary to be able to detect low numbers in food, and the lack of sensitivitiy of direct plating has led to the development of various enrichment and detection methods. Until now, the most selective procedure for detection of E. coli O157 isolates was the immunomagnetic separation (IMS) method. The number of sorbitol non-fermenting micro-organisms other than E. coli O157 that adhere non-specifically to the magnetic beads hampers the application of IMS. The use of IMS in conjunction with 3 M Petrifilm-HECTM yielded EHEC O157 in 21 of 165 samples of minced meat (12·7%). Without advance application of IMS, Petrifilm plates often yield confluent growth and colonies too numerous to count. The Vitek Immunodiagnostic Assay SystemTM (VIDAS-ECO) showed good sensitivity when testing artificially contaminated beef samples, but only four of 21 naturally contaminated samples were recognized. The addition of 3 M Petrifilm to IMS resulted in less growth of contaminants and eliminated much of the need to test presumed colonies for confirmation. The combination of IMS with 3 M Petrifilm-HECTM is a fast and efficient screening procedure for E. coli O157 in minced meat.  相似文献   

6.
AIMS: The aims of this study were (i) to evaluate the specificity and sensitivity of three previously described PCR assays for the detection of E. coli O157 and, (ii) to compare PCR, culture, and two visual immunoassays (VIAs), BioSign and Path-Stik, for detecting E. coli O157 after enrichment culture and immunomagnetic separation (IMS) performed on various naturally contaminated raw beef, lamb and mixed meat products. METHODS AND RESULTS: Twelve sorbitol non fermenting (SNF) verocytotoxin-producing (VT+) E. coli O157, 6 SNF VT- E. coli O157, 4 sorbitol fermenting (SF) VT+ E. coli O157, 3 SF VT- E. coli O157, 23 E. coli belonging to 17 other serogroups and 12 organisms of other species were used to check the specificity of PCR reactions. Only one primer pair generated amplimers only with E. coli O157 and was used for all subsequent work. After enrichment culture and on inoculated minced beef samples, PCR was as sensitive as culture for detecting 9 of the 12 strains of E. coli O157, but up to 4 log10 more sensitive than culture for detecting three strains. Of the 120 samples of naturally contaminated meat products examined, 80 (67%) were positive by PCR, 70 (58%) were positive by BioSign, 69 (58%) were positive by culture and 67 (56%) were positive by Path-Stik. Eleven samples were positive by PCR and both VIAs, but negative by culture because culture plates were heavily overgrown with SF organisms making detection of any E. coli O157 present impossible. CONCLUSIONS: PCR and both VIAs compared well with culture of beads to CT-SMAC for detecting E. coli O157 after enrichment culture and IMS. PCR appeared to be the most sensitive method, but needed specialised equipment and was also the most expensive, laborious and technically demanding technique. Although lacking the sensitivity of PCR, the VIAs were of comparable sensitivity to culture and were extremely quick and easy to perform giving a result in less than 15 minutes. SIGNIFICANCE AND IMPACT OF THE STUDY: Culture techniques may fail to detect E. coli O157 retrieved by IMS due to overgrowth with other organisms.  相似文献   

7.
In this study, enrichment procedures and two recovery methods, a membrane surface adhesion technique and an immunomagnetic separation (IMS), were compared for use in conjunction with a multiplex polymerase chain reaction (PCR) method with a view to describing a fast (24 h) and economical test for detection of Escherichia coli O157:H7 in meat samples. The study showed no significant difference between three different enrichment media (BHI, E. coli (E.C.) broth+novobiocin, modified tryptone soya broth (mTSB)+novobiocin) or two incubation temperatures (37 or 41.5 degrees C) for growth of E. coli O157:H7 in minced beef. Minced beef samples inoculated with E. coli O157:H7 at 40 cfu g(-1) were incubated at 37 degrees C for 16 h in E.C. broth+novobiocin reaching numbers of (log(10)7.82-8.70). E. coli O157:H7 were recovered by attachment to polycarbonate membranes immersed in the enriched cultures for 15 min or by immunomagnetic separation. Subsequent treatment of recovered membranes or IMS beads with lysis buffer and phenol/chloroform/isoamyl alcohol was used to extract the DNA from the extracted E. coli O157:H7 cells. The results show when E. coli O157:H7 was present at high levels in the enriched meat sample (log(10)9.6-7.5 cfu ml(-1); >16-h enrichment), the membrane and IMS techniques recovered similar levels of the pathogen and the microorganism was detectable by PCR using both methods. At lower levels of E. coli O157:H7 (log(10)6.4), only the IMS method could recover the pathogen but at levels below this neither method could recover sufficient numbers of the pathogens to allow detection. The conclusion of the study is that with sufficient enrichment time (16 h) the membrane surface adhesion membrane extraction method used in combination with multiplex PCR has the potential for a rapid and economical detection method.  相似文献   

8.
AIMS: This study was conducted to evaluate the effect of supplementing barley- or corn-based diets with canola oil on faecal shedding of Escherichia coli O157:H7 by experimentally inoculated feedlot cattle. METHODS AND RESULTS: Four groups of yearling steers fed on barley- or corn-based feedlot diets containing 0% (BA; CO) or 6% canola oil (BA-O; CO-O) were inoculated with 10(10) CFU of a mixture of four nalidixic acid-resistant strains of E. coli O157:H7. The inoculated strains were tracked in oral (mouth swab) and environmental (water, water bowl interface, feed, faecal pat) samples by enrichment and immunomagnetic separation (IMS) for 12 weeks, and in rectally collected faecal samples for 23 weeks (enumeration by dilution plating for 12 weeks; detection by IMS for a further 11 weeks). Levels of E. coli O157:H7 shed in faecal samples over the course of the enumeration period were similar (P = 0.14) among treatments. Disappearance of the inoculated strains from faeces was more rapid (P = 0.009) with barley than with corn, but shedding levels at the end of the enumeration period were similar (P = 0.21) across grain types. Canola oil supplementation did not affect (P = 0.71) the rate of disappearance of E. coli O157:H7 from faeces. The numbers of steers culture positive for E. coli O157:H7 during the enumeration period were similar (P = 0.57) among treatments. During the 11-week detection period, however, more (P < 0.001) steers were E. coli O157:H7-positive in the BA group (15/64) than in BA-O (two of 64), CO (two of 56), or CO-O (one of 56). The organism was present in two of 48 water samples (both CO-O), one of 48 water bowl swabs (BA-O), four of 48 feed samples (two of 12 BA; two of 12 CO-O), 30 of 48 pen floor faecal pat samples, and 296 of 540 mouth swabs (81/144 BA, 80/144 BA-O, 74/126 CO and 61/126 CO-O). CONCLUSION: Supplementing corn or barley-based diets with canola oil did not affect shedding of E. coli O157:H7 by feedlot cattle. SIGNIFICANCE AND IMPACT OF THE STUDY: High-shedding individuals (i.e. 'super shedders') may be responsible for disseminating E. coli O157:H7 among penmates. Faeces on pen floors appears to be a more significant source of infection than are feed or drinking water.  相似文献   

9.
AIM: To quantify the effect of enrichment, immunomagnetic separation (IMS), and selective plating procedures on isolation of Shiga-toxigenic Escherichia coli O157 (STEC O157) and non-Shiga-toxigenic Escherichia coli O157 (non-STEC O157) from naturally contaminated bovine faeces. METHODS AND RESULTS: Two broth enrichment times, two IMS strategies, and two selective plating media were evaluated. STEC O157 and non-STEC O157 strains were often isolated from the same faecal specimen and responded differently to the isolation protocols. A large-volume IMS system was more sensitive than a conventional small-volume IMS method, but was also more expensive. STEC O157 was more frequently isolated from 6 h enriched broth and ChromAgar plates containing 0.63 mg l(-1) potassium tellurite (TCA). Non-STEC O157 was more frequently isolated from un-enriched broth and ChromAgar plates without tellurite (CA). CONCLUSIONS: The combination of 6-h enrichment in Gram-negative broth containing vancomycin, cefixime and cefsuludin, large volume IMS and selective plating on TCA maximized STEC O157 recovery from naturally contaminated cattle faecal specimens. SIGNIFICANCE AND IMPACT OF THE STUDY: The pairing of proper enrichment with a specific plating procedure is key for STEC O157 recovery from naturally contaminated bovine faeces. Incorporating tellurite into an E. coli O157 detection strategy may select for the subset of E. coli O157 that contains the Shiga-toxin genes.  相似文献   

10.
Sensitivities of direct plate culture (DPC) method, immunomagnetic separation (IMS) method, and polymerase chain reaction (PCR) assay for successful detection Escherichia coli O157 in the food samples were compared. Three lots of minced beef and three lots of radish sprout, both of which were commercially retailed, were enriched with non-selective broth media at 36 degrees C for 6 h. After enrichment, the cultures of the minced beef and those of the radish sprout were found to have background microflora at ca.10(5)-10(7) CFU/ml and ca.10(8) CFU/ml, respectively. The cultures were then experimentally inoculated with E. coli O157 strains at various final concentrations ranging from ca.10 to 10(7) CFU/ml. The samples thus prepared were subjected to the above three methods to evaluate their detection limits. For the samples of minced beef, the detection limits of the DPC method was 10(2) CFU/ml whilst that of the IMS method was ca.10 CFU/ml. For the samples of radish sprout, the detection limits of the DPC method, the IMS method, and the PCR assay were ca.10(4) CFU/ml, ca.10(2) CFU/ml, and ca.10(6) CFU/ml, respectively. There results strongly suggest that the IMS method is most sensitive method for the detection of O157 from food samples among the methods currently available.  相似文献   

11.
AIMS: Escherichia coli O157 is considered to be one of most important human pathogens of animal origin which causes serious clinical complications. One of the most common methods to isolate E. coli O157 is the immunomagnetic separation (IMS) technique which employs specific antibodies coupled to magnetic beads to bind and extract cells from enrichment broths followed by plating onto sorbitol MacConkey agar supplemented with cefixime and potassium tellurite (CT-SMAC) plates. The aim of this study was to determine strain variation by pulsed-field gel electrophoresis (PFGE) among E. coli O157 on IMS/CT-SMAC plates. METHODS AND RESULTS: Every suspect colony of E. coli O157 was tested following isolation by the IMS/CT-SMAC technique. From 124 colonies detected; six XbaI-PFGE profiles were identified. CONCLUSIONS: Our results demonstrate that mixed populations of E. coli O157 with distinguishable PFGE profiles that are simultaneously present in bovine faeces can be isolated with IMS/CT-SMAC technique. SIGNIFICANCE AND IMPACT OF THE STUDY: If the aim of the study was to analyse diversity of PFGE profiles of E. coli O157 in a faecal sample following isolation by the IMS/CT-SMAC technique, at least five colonies per sample should be analysed to detect different PFGE subtypes if present.  相似文献   

12.
Fifty-four of 310 (17%) samples of raw beef products contained Vero cytotoxin (VT)-producing Escherichia coli (VTEC) detected by DNA probes for the VT genes. VTEC strains examined in detail from a selection of the positive samples belonged to several O serogroups, some of which have been associated with human diarrhoea or haemolytic uraemic syndrome. Some of the strains possessed properties that may contribute to virulence in man. None of the food samples contained VT-producing E. coli O157 when tested by a combination of VT probe tests and colony immunoblotting with commercially available anti-O157 serum. Quantification of the immunoblotting technique indicated that O157 VTEC could be recovered from artificially-inoculated meat samples at a level of less than one organism per gram. Five of the food samples carried E. coli O157 strains that did not produce VT and differed in other properties from O157 VTEC.  相似文献   

13.
AIM: To develop and validate a direct plating method applicable to epidemiological studies for enumerating Escherichia coli O157 in cattle faeces. METHODS AND RESULTS: The spiral plate count method was used to enumerate E. coli O157 in faecal samples. The accuracy and variation of counts was then assessed using faecal samples inoculated with E. coli O157. There was good agreement between inoculated levels of E. coli O157 and those recovered from faeces, particularly when counts were > 10(2) CFU g(-1) of faeces. The method was applied to a small study assessing short-term survival of E. coli O157 in naturally infected cattle faeces. E. coli O157 was found to survive in faeces for over 10 days at concentrations above 10(3) CFU g(-1) of faeces. Populations of E. coli O157 were also found to increase 100-fold in the first few hours after defecation. CONCLUSIONS: The enumeration method is easy to implement and enables a quick throughput of large numbers of samples. The method is accurate and reliable and enables the inherent variation in count data to be explored but needs to be used in combination with a more sensitive method for samples containing < 10(2) CFU g(-1) of faeces. SIGNIFICANCE AND IMPACT OF THE STUDY: The method described is appropriate for enumeration of E. coli O157 in cattle faeces in large-scale epidemiological studies.  相似文献   

14.
Artificially inoculated Escherichia coli O157:H7 was directly enumerated in ground beef and beef exudate, without enrichment or selection, by the antibody-direct epifluorescent filter technique (Ab-DEFT). The total assay time of the Ab-DEFT was less than 1 h. The beef was homogenized, treated for 15 min with trypsin and Triton X-100, and passed through a 5-microns-pore-size prefilter and then through a 0.2-microns-pore-size black polycarbonate filter. The final filter was stained directly with fluorescein-labeled anti-O157 polyclonal antibody, rinsed, and examined by epifluorescence microscopy. The sensitivity of the Ab-DEFT was compared with that of a standard enrichment culture technique. Both methods reliably determined the presence of the pathogen in beef at 16 CFU/g. The Ab-DEFT was also useful for quantifying the pathogen and monitoring its growth in beef.  相似文献   

15.
We report here the use of immunomagnetic (IM) electrochemiluminescence (ECL) for quantitative detection of Esherichia coli O157:H7 in water samples following enrichment in minimal lactose broth (MLB). IM beads prepared in-house with four commercial anti-O157 monoclonal antibodies were compared for efficiency of cell capture. IM-ECL responses for E. coli O157:H7 (strain SEA13B88) were similar for all four commercial anti-O157 LPS monoclonal antibodies. The ECL signal was linearly correlated with E. coli O157:H7 cell concentration, indicating a constant ECL response per cell. Twenty-two strains of E. coli O157:H7 or O157:NM gave comparable ECL signals using IM beads prepared in-house. To assess the potential for interference from background bacteria in MLB-enriched water samples, 10(4) cells of E. coli O157:H7 (strain SEA13B88) were added to enriched samples prior to analysis. There was considerable variability in recovery of E. coli O157:H7 cells; net ECL signals ranged from 1% to 100% of expected values (i.e., percent inhibition from 0% to 99%). Cultures of Klebsiella pneumoniae, Klebsiella oxytoca, and Enterobacter cloacae, subsequently isolated from MLB-enriched water samples via IM separation (IMS), were observed to interfere with the binding of E. coli O157:H7 cells to IM beads. Recoveries of 10(4) E. coli O157:H7 cells were 相似文献   

16.
Both 25-g single-size ground beef samples and 375-g composite ground beef samples were tested by a method combining an immunomagnetic separation (IMS) technique with a sandwich enzyme-linked immunosorbent assay (ELISA) system (IMS-ELISA). The results demonstrated that IMS-ELISA could detect the target, Escherichia coli O157:H7, at the level of 10(-1) CFU/g of sample in either the 25- or 375-g sample size.  相似文献   

17.
The distribution of Escherichia coli O157 in bovine feces was examined by testing multiple samples from fecal pats and determining the density of E. coli O157 in immunomagnetic separation (IMS)-positive fecal samples. The density of E. coli O157 in bovine feces was highly variable, differing by as much as 76,800 CFU g(-1) between samples from the same fecal pat. The density in most positive samples was <100 CFU g(-1), the limit of reliable detection by IMS. Testing only one 1-g sample of feces per pat with IMS may result in a sensitivity of detection as low as 20 to 50%. It is therefore probable that most surveys have greatly underestimated the prevalence of E. coli O157 shedding in cattle and the proportion of farms with shedding cattle. The sensitivity of the detection of E. coli O157 in bovine feces can be as much as doubled by testing two 1-g samples per pat rather than one 1-g sample.  相似文献   

18.
Escherichia coli O157:H7, a major foodborne pathogen, has been associated with numerous cases of foodborne illnesses. Rapid methods have been developed for the screening of this pathogen in foods in order to circumvent timely plate culture techniques. Unfortunately, many rapid methods are presumptive and do not claim to confirm the presence of E. coli O157:H7. The previously developed method, enzyme-linked immunomagnetic chemiluminescence (ELIMCL), has been improved upon to allow for fewer incidences of false positives when used to detect E. coli O157:H7 in the presence of mixed cultures. The key feature of this assay is that it combines the highly selective synergism of both anti-O157 and anti-H7 antibodies in the sandwich immunoassay format. This work presents application of a newly semi-automated version of ELIMCL to the detection of E. coli O157:H7 in pristine buffered saline yielding detection limits of approximately 1 x 10(5) to 1 x 10(6) of live cells/mL. ELIMCL was further demonstrated to detect E. coli O157:H7 inoculated into artificially contaminated ground beef at ca. 400 CFU/g after a 5 h enrichment and about 1.5 h assay time for a total detection time of about 6.5 h. Finally, ELIMCL was compared with USFDA's Bacteriological Analytical Manual method for E. coli O157:H7 in a double-blind study. Using McNemar's treatment, the two methods were determined to be statistically similar for the detection of E. coli O157:H7 in ground beef inoculated with mixed cultures of select bacteria.  相似文献   

19.
A.R. BENNETT, S. MACPHEE AND R.P. BETTS. 1996. The use of immunomagnetic separation (IMS) techniques has been reported to reduce the total test time, and improve the sensitivity, of microbiological tests done on foods. This approach is being adopted in epidemiological investigations into suspected foodborne outbreaks of Escherichia coli O157 infection and has gained acceptance by public health laboratories and the food industry. This study demonstrated the ability of a commercially available IMS procedure, Dynabeads anti- E. coli O157, to enable detection of a few cells of E. coli O157 in 25 g of inoculated minced beef, giving results 1 d earlier than a cultural analysis of similar sensitivity. With correct choice of enrichment broths, IMS may increase isolation rate of E. coli O157 compared to that obtained using conventional cultural methods. It is suggested that this may be due to an increase in relative concentration of E. coli O157 compared with the background microflora present in minced beef, which may reduce reliability of non-IMS detection procedures by masking or mimicking target cells on selective/differential solid media. The use of an immunoassay incorporating an IMS step, EHEC-Tek (Organon-Teknika), enabled detection of a few cells of E. coli O157 in 25 g of minced beef. Comparison of the IMS-ELISA with a standard ELISA procedure (Tecra) indicated the sensitivity of the latter system to be greater, perhaps resulting in the higher isolation rate. The use of a method to reliability isolate and detect extremely low levels of E. coli O157 in a food is necessary to aid reduction in the incidence of this most serious of foodborne pathogens.  相似文献   

20.
A protocol for the quantitative detection of Escherichia coli O157 in raw and concentrated surface waters using immunomagnetic electrochemiluminescence (IM-ECL) was developed and optimized. Three antibody sandwich formats were tested: commercial anti-O157:H7 IM beads, IM beads made in-house with a polyclonal anti-O157:H7 immunoglobulin G (IgG), or IM beads made in-house with a monoclonal anti-O157:H7 IgG coupled with a polyclonal anti-O157:H7 IgG to which an electrochemiluminescent label (TAG) was attached. The monoclonal IM bead-polyclonal TAG format was chosen for optimization because it gave lower background levels and linear regression slopes of ca. 1.0, indicative of a constant ECL signal per cell. The dynamic range was ca. 10(1) to 10(5) cells ml(-1) in phosphate-buffered saline and in raw water samples. The monoclonal IM beads selectively captured E. coli O157 cells in the presence of ca. 10(8) cells of a non-O157 strain of E. coli ml(-1). Background ECL signals from concentrated (100-fold) water samples were substantially higher and more variable than raw water samples. The background signal was partially eliminated by the addition of polyvinylpolypyrrolidone. Successive cell capture incubations, termed sequential bead capture (SBC), were optimized for establishing baseline ECL values for individual water samples. The linear dynamic range with SBC was ca. 10(2) to 10(5) E. coli O157 cells ml of concentrated water(-1). To validate the protocol, 10-liter surface water samples were spiked with ca. 5,000 E. coli O157 (Odwalla) cells and concentrated by vortex filtration, and 1- or 3-ml aliquots were analyzed by IM-ECL. Differential ECL signals (SBC) from 1- and 3-ml samples were statistically significant and were generally consistent with standard curves for these cell concentrations. Enrichments were conducted with aliquots of spiked raw water and concentrated water using EC broth and minimal lactose broth (MLB). All tubes with concentrated water became turbid and gave a positive ECL response for E. coli O157 (>10,000 ECL units); MLB gave a somewhat higher detection rate with spiked raw water. The potential sensitivity of the IM-ECL assay is ca. 25 E. coli O157 cells ml of raw water(-1), 25 cells 100 ml of 100-fold concentrated water(-1), or 1 to 2 viable cells liter(-1) with concentration and enrichment. The IM-ECL assay appears suitable for routine analysis and screening of water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号