首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Semi-automated 96-well plate solid-phase extraction (SPE) was used for sample preparation of fluprostenol, a prostaglandin analog, in rat plasma prior to detection by gas chromatography–negative chemical ionization tandem mass spectrometry (GC–NCI-MS–MS). A liquid handling system was utilized for all aspects of sample handling prior to SPE including transferring of samples into a 96-well format, preparation of standards as well as addition of internal standard to standards, quality control samples and study samples. SPE was performed in a 96-well plate format using octadecylsilane packing and the effluent from the SPE was dried in a custom-made 96-well apparatus. The sample residue was derivatized sequentially with pentafluorobenzylbromide followed by N-methyl-N-trimethylsilyltrifluoroacetamide. The derivatized sample was then analyzed using GC–NCI-MS–MS. The dynamic range for the method was from 7 to 5800 pg/ml with a 0.1-ml plasma sample. The methodology was evaluated over a 4-day period and demonstrated an accuracy of 90–106% with a precision of 2.4–12.9%.  相似文献   

2.
Oligosaccharides attached to Asn297 in each of the CH2 domains of monoclonal antibodies play an important role in antibody effector functions by modulating the affinity of interaction with Fc receptors displayed on cells of the innate immune system. Rapid, detailed, and quantitative N-glycan analysis is required at all stages of bioprocess development to ensure the safety and efficacy of the therapeutic. The high sample numbers generated during quality by design (QbD) and process analytical technology (PAT) create a demand for high-performance, high-throughput analytical technologies for comprehensive oligosaccharide analysis. We have developed an automated 96-well plate-based sample preparation platform for high-throughput N-glycan analysis using a liquid handling robotic system. Complete process automation includes monoclonal antibody (mAb) purification directly from bioreactor media, glycan release, fluorescent labeling, purification, and subsequent ultra-performance liquid chromatography (UPLC) analysis. The entire sample preparation and commencement of analysis is achieved within a 5-h timeframe. The automated sample preparation platform can easily be interfaced with other downstream analytical technologies, including mass spectrometry (MS) and capillary electrophoresis (CE), for rapid characterization of oligosaccharides present on therapeutic antibodies.  相似文献   

3.
A high throughput preparation method for the determination of trileptal (oxcarbazepine, OXC) and its mono (MHD) and dihydroxy (DHD) metabolites in human plasma, using 96-well plate technology, has been developed and validated according to international regulatory requirements. Preparation of plasma samples (50 μl) containing the compounds to be analysed involved solid-phase extraction (SPE) on Empore C18 96-well SPE plates. Eluates from the plate were injected onto a reversed-phase column (Hypersil C18, 3 μm) with UV detection at 210 nm. Detector response was linear over the ranges 0.2–10, 0.1–200 and 0.1–20 μmol/l, for OXC, MHD and DHD, respectively, with relative standard deviations from 1 to 10% and mean accuracies within 4% of the nominal values (number of standard curves=3 in duplicate). The limits of quantitation were 0.2, 0.1 and 0.1 μmol/l, respectively. The overall mean accuracies ranged from 96 to 106% and precision was in the range 4 to 11%. Cross validation indicated no significant difference between plasma concentrations obtained using the 96-well method and the previous method using a traditional SPE method with a 50 mg C18 cartridge. About a threefold increase in sample throughput and a twofold decrease of plasma volume required for the assays, were the main advantages obtained from the previous method. The method was applied for the determination of 3000 plasma samples from clinical studies.  相似文献   

4.
High-throughput quantitative analytical method for plant N-glycan has been developed. All steps, including peptide N-glycosidase (PNGase) A treatment, glycan preparation, and exoglycosidase digestion, were optimized for high-throughput applications using 96-well format procedures and automatic analysis on a DNA sequencer. The glycans of horseradish peroxidase with plant-specific core α(1,3)-fucose can be distinguished by the comparison of the glycan profiles obtained via PNGase A and F treatments. The peaks of the glycans with (91%) and without (1.2%) α(1,3)-fucose could be readily quantified and shown to harbor bisecting β(1,2)-xylose via simultaneous treatment with α(1,3)-mannosidase and β(1,2)-xylosidase. This optimized method was successfully applied to analyze N-glycans of plant-expressed recombinant antibody, which was engineered to contain a minor amount of glycan harboring β(1,2)-xylose. These results indicate that our DNA sequencer-based method provides quantitative information for plant-specific N-glycan analysis in a high-throughput manner, which has not previously been achieved by glycan profiling based on mass spectrometry.  相似文献   

5.
High throughput methods for recombinant protein production using E. coli typically involve the use of affinity tags for simple purification of the protein of interest. One drawback of these techniques is the occasional need for tag removal before study, which can be hard to predict. In this work, we demonstrate two high throughput purification methods for untagged protein targets based on simple and cost-effective self-cleaving intein tags. Two model proteins, E. coli beta-galactosidase (βGal) and superfolder green fluorescent protein (sfGFP), were purified using self-cleaving versions of the conventional chitin-binding domain (CBD) affinity tag and the nonchromatographic elastin-like-polypeptide (ELP) precipitation tag in a 96-well filter plate format. Initial tests with shake flask cultures confirmed that the intein purification scheme could be scaled down, with >90% pure product generated in a single step using both methods. The scheme was then validated in a high throughput expression platform using 24-well plate cultures followed by purification in 96-well plates. For both tags and with both target proteins, the purified product was consistently obtained in a single-step, with low well-to-well and plate-to-plate variability. This simple method thus allows the reproducible production of highly pure untagged recombinant proteins in a convenient microtiter plate format.  相似文献   

6.

Background

The unmitigated rise in demand for the assessment of vitamin D status has taxed the ability of clinical mass spectrometry laboratories to preserve turn-around times. We aimed to improve the throughput of liquid–liquid extraction of plasma/serum for the assay of 25-hydroxy vitamin D.

Methods

We designed and fabricated a flexible rubber gasket that seals two 96-well plates together to quantitatively transfer the contents of one plate to another. Using the transfer gasket and a dry-ice acetone bath to freeze the aqueous infranatant, we developed a novel liquid–liquid extraction workflow in a 96-well plate format. We applied the technology to the mass spectrometric quantification of 25-hydroxy vitamin D.

Results

Cross-contamination between wells was ≤0.13%. The interassay imprecision over 132 days of clinical implementation was less than 10%. The method compared favorably to a standard liquid–liquid extraction in glass tubes (Deming slope = 1.018, Sx|y = 0.022). The accuracy of the assay was 102–105% as assessed with the recently released control materials from NIST.

Conclusions

The development of a plate-sealing gasket permits the liquid–liquid extraction of clinical specimens in a moderate-throughput workflow and the reliable assay of vitamin D status. In the future, the gasket may also prove useful in other sample preparation techniques for HPLC or mass spectrometry.  相似文献   

7.
Radio frequency plasma treatment of 96-well PCR polypropylene plate, using O2, decreased DNA adsorption relative to untreated plates. Furthermore, radio frequency plasma treatment with a N2/H2 gas mixture increased DNA adsorption. This technique provides a simple means of modifying DNA adsorption to PCR polypropylene plates for various applications.  相似文献   

8.
In this study, we developed a CdSe/ZnS quantum dot (QD)-based immunoassay for use in determining the presence of progesterone (P4) in human serum. Hydrophilic QDs were conjugated to anti-progesterone antibody (P4Ab) via ethyl-3-(dimethylaminopropyl)carbodiimide (EDC) and N-hydroxysuccinimide (NHS) as coupling reagents. After purification, the P4Ab–QD conjugates were immobilized onto the wells of a 96-well microtiter plate, and a direct-binding immunoassay based on the binding of P4 to immobilized P4Ab–QD conjugates had a detection limit of 0.21 ng/ml and a sensitivity of 1.37 ng/ml, with a linear range of 0.385 to 4.55 ng/ml. The proposed immunoassay was successfully used to determine the P4 concentration in real human serum, and the results showed a good correlation with the accredited radioimmunoassay (RIA).  相似文献   

9.
It is becoming common for plant scientists to develop projects that require the genotyping of large numbers of plants. The first step in any genotyping project is to collect a tissue sample from each individual plant. The traditional approach to this task is to sample plants one-at-a-time. If one wishes to genotype hundreds or thousands of individuals, however, using this strategy results in a significant bottleneck in the genotyping pipeline. The Ice-Cap method that we describe here provides a high-throughput solution to this challenge by allowing one scientist to collect tissue from several thousand seedlings in a single day 1,2. This level of throughput is made possible by the fact that tissue is harvested from plants 96-at-a-time, rather than one-at-a-time.The Ice-Cap method provides an integrated platform for performing seedling growth, tissue harvest, and DNA extraction. The basis for Ice-Cap is the growth of seedlings in a stacked pair of 96-well plates. The wells of the upper plate contain plugs of agar growth media on which individual seedlings germinate. The roots grow down through the agar media, exit the upper plate through a hole, and pass into a lower plate containing water. To harvest tissue for DNA extraction, the water in the lower plate containing root tissue is rapidly frozen while the seedlings in the upper plate remain at room temperature. The upper plate is then peeled away from the lower plate, yielding one plate with 96 root tissue samples frozen in ice and one plate with 96 viable seedlings. The technique is named "Ice-Cap" because it uses ice to capture the root tissue. The 96-well plate containing the seedlings can then wrapped in foil and transferred to low temperature. This process suspends further growth of the seedlings, but does not affect their viability. Once genotype analysis has been completed, seedlings with the desired genotype can be transferred from the 96-well plate to soil for further propagation. We have demonstrated the utility of the Ice-Cap method using Arabidopsis thaliana, tomato, and rice seedlings. We expect that the method should also be applicable to other species of plants with seeds small enough to fit into the wells of 96-well plates.  相似文献   

10.
We describe a 96-well plate compatible membrane-based proteomic sample processing method, which enables the complete processing of 96 samples (or multiples thereof) within a single workday. This method uses a large-pore hydrophobic PVDF membrane that efficiently adsorbs proteins, resulting in fast liquid transfer through the membrane and significantly reduced sample processing times. Low liquid transfer speeds have prevented the useful 96-well plate implementation of FASP as a widely used membrane-based proteomic sample processing method. We validated our approach on whole-cell lysate and urine and cerebrospinal fluid as clinically relevant body fluids. Without compromising peptide and protein identification, our method uses a vacuum manifold and circumvents the need for digest desalting, making our processing method compatible with standard liquid handling robots. In summary, our new method maintains the strengths of FASP and simultaneously overcomes one of the major limitations of FASP without compromising protein identification and quantification.Mass spectrometry (MS)-based proteomics is moving increasingly into the translational and clinical research arena, where robust and efficient sample processing is of particular importance. The conventional sample processing methods in proteomics, namely SDS-PAGE, or in-solution-based sample processing, are slow and laborious and thus do not easily provide the reproducibility and throughput to meet current demands. A paradigm shift was the introduction of a filter-aided sample processing method (FASP), which is initially described by Manza et al. (1) and then fully realized in practice by Wisniewski et al. (2). These filter-aided methods make use of ultrafiltration membranes with molecular weight cut offs (MWCO) in the 10 to 30 kDa range to efficiently remove small molecules and salts and to capture denatured proteins on a cellulose filter even if the molecular weight of the protein is much smaller than the nominal MWCO of the ultrafiltration membrane. Thus, the denaturation step is crucial to ensure that proteins much smaller than the nominal MWCO are efficiently retained by, e.g. a 10 kDa MWCO filter.In translational and clinical proteomics, which normally include large cohorts, the multititer-well plate is the preferred format for sample processing and storage. Although the application of FASP in the 96-well plate format has been described (3, 4), the major limitation of FASP in the 96-well plate is the much slower speed at which the 96-well plates have to be centrifuged: while a single ultrafiltration unit withstands up to 14,000 × g, the 96-well plate format can only be centrifuged at g-forces of up to 2,200 × g. This significantly lower g-force for 96-well plates results in a slow liquid transfer, which in turn considerably prolongs the required centrifugation times to hours instead of tens of minutes for the three to four necessary centrifugation steps (i) for the initial loading, reduction and alkylation, (ii) for the different washing steps, and (iii) for the elution (3).Independent of the format FASP is performed in, the conventional FASP also requires relative large volumes of high salt concentration for efficient elution of the tryptic peptides. Hence, reversed-phase-based desalting of the samples is a prerequisite for subsequent LC/MS experiments. Apart from prolonging the entire FASP procedure, the numerous additional handling steps are potentially also associated with peptide losses (5).In this study, we describe a novel sample processing workflow for MS-based proteomics that utilizes the strengths of filter-aided sample processing methods and at the same time overcomes their major limitations, without compromising the results, i.e. significantly reducing the number of identified peptides and/or proteins. The result is a significantly improved throughput as 96 samples (or multiples thereof) can be completely processed within a single workday.  相似文献   

11.
High-throughput screening (HTS) of small-molecule libraries against pharmacological targets is a key strategy of contemporary drug discovery. This study reports a simple, robust, and cell-based luminescent method for assaying antimalarial drugs. Using transfection technology, we generated a stable Plasmodium falciparum line with high levels of firefly luciferase expression. A luciferase assay based on this parasite line was optimized in a 96-well plate format and used to compare with the standard [3H] hypoxanthine radioisotope method. The 50% inhibitory concentrations (IC50s) of chloroquine, artesunate, artemether, dihydroartemisinin and curcumin obtained by these two methods were not significantly different (P > 0.05, ANOVA). In addition, this assay could be performed conveniently with a luminescence plate reader using unsynchronized stages within as early as 12 h. Furthermore, the luciferase assay is robust with a Z′ score of 0.77-0.92, which suggests the feasibility for further miniaturization and automation.  相似文献   

12.
The structural domains of proteins have often been identified through the use of limited proteolysis. In structural genomics studies, it is necessary to carry this out in a high-throughput manner. Here, we constructed a novel high-throughput system, which consists of cell-free protein expression and one-step affinity purification, followed by limited proteolysis using a unique new method, referred to “on beads method”. All these steps were carried out on 96-well plate formats and completed in two days, even by manual handling. The merits of the new method versus the conventional one are as follows: (1) experimental times are reduced, (2) the sample preparation for limited proteolysis experiments is simplified, and (3) both protein purification and limited digestion can be performed “in situ” on the same sample plate. This preparation method is therefore suitable for highly automated, proteolytic analyses coupled to mass spectrometry techniques at a micro-scale protein expression level. The resulting protease-resistant fragments were analyzed by MALDI-TOF-MS and protein domains of 34 mouse cDNA products were identified with this system.  相似文献   

13.
14.
15.
A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an alpha(v)beta(3) bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreen filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column-switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer interfaced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using Ultracel-PPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and <7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0.1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible.  相似文献   

16.

Background  

Analyzing apoptosis has been an integral component of many biological studies. However, currently available methods for quantifying apoptosis have various limitations including multiple, sometimes cell-damaging steps, the inability to quantify live, necrotic and apoptotic cells at the same time, and non-specific detection (i.e. "false positive"). To overcome the shortcomings of current methods that quantify apoptosis in vitro and to take advantage of the 96-well plate format, we present here a modified ethidium bromide and acridine orange (EB/AO) staining assay, which may be performed entirely in a 96-well plate. Our method combines the advantages of the 96-well format and the conventional EB/AO method for apoptotic quantification.  相似文献   

17.
In this study, the in vitro activities of a natural sesquiterpene, α-cyperotundone, isolated from the root bark of Maytenus retusa and a cobalt(II)-complex of a natural occurring prenyl hydroxynaphthoquinone (lapachol) were evaluated against the trophozoite stage of Acanthamoeba castellanii Neff using a previously developed colorimetric 96-well microtiter plate assay, based on the oxido-reduction of Alamar Blue®. The obtained activities showed that these two compounds were able to inhibit the in vitro growth of the amoebae at relatively low concentrations. Further identification of the molecular targets of these products and their effects on acanthamoebae should be determined to evaluate their possible therapeutic use.  相似文献   

18.
In microorganisms, and more particularly in yeasts, a standard phenotyping approach consists in the analysis of fitness by growth rate determination in different conditions. One growth assay that combines high throughput with high resolution involves the generation of growth curves from 96-well plate microcultivations in thermostated and shaking plate readers. To push the throughput of this method to the next level, we have adapted it in this study to the use of 384-well plates. The values of the extracted growth parameters (lag time, doubling time and yield of biomass) correlated well between experiments carried out in 384-well plates as compared to 96-well plates or batch cultures, validating the higher-throughput approach for phenotypic screens. The method is not restricted to the use of the budding yeast Saccharomyces cerevisiae, as shown by consistent results for other species selected from the Hemiascomycete class. Furthermore, we used the 384-well plate microcultivations to develop and validate a higher-throughput assay for yeast Chronological Life Span (CLS), a parameter that is still commonly determined by a cumbersome method based on counting “Colony Forming Units”. To accelerate analysis of the large datasets generated by the described growth and aging assays, we developed the freely available software tools GATHODE and CATHODE. These tools allow for semi-automatic determination of growth parameters and CLS behavior from typical plate reader output files. The described protocols and programs will increase the time- and cost-efficiency of a number of yeast-based systems genetics experiments as well as various types of screens.  相似文献   

19.
Luminescent Identification of Functional Elements in 3’UTRs (3’LIFE) allows the rapid identification of targets of specific miRNAs within an array of hundreds of queried 3’UTRs. Target identification is based on the dual-luciferase assay, which detects binding at the mRNA level by measuring translational output, giving a functional readout of miRNA targeting. 3’LIFE uses non-proprietary buffers and reagents, and publically available reporter libraries, making genome-wide screens feasible and cost-effective. 3’LIFE can be performed either in a standard lab setting or scaled up using liquid handling robots and other high-throughput instrumentation. We illustrate the approach using a dataset of human 3’UTRs cloned in 96-well plates, and two test miRNAs, let-7c and miR-10b. We demonstrate how to perform DNA preparation, transfection, cell culture and luciferase assays in 96-well format, and provide tools for data analysis. In conclusion 3''LIFE is highly reproducible, rapid, systematic, and identifies high confidence targets.  相似文献   

20.
We describe two alternative assays for measuring collagenolytic activity using (3)H-acetylated collagen. Both assays have been developed for the 96-well plate format and measure the amount of radiolabeled collagen fragments released into the supernatant from an insoluble (3)H-acetylated collagen fibril preparation. The first method separates digested solubilized fragments from the intact fibril by sedimentation of the undigested collagen by centrifugation. The second method achieves this separation by filtration of the supernatant through the membrane of a 96-well filtration plate which retains the undigested collagen fibril. Both methods give linear dose- and time-dependent responses of collagenase activity > or = 70% of total collagen lysis. In addition, both assays can be simply modified to measure tissue inhibitors of metalloproteinases (TIMPs) inhibitory activity, which is also linear between 20 and 75% of total collagen lysis with the amount of TIMP added.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号