1.

Purpose

The purpose of this study was to compare the properties of the median nerve and the flexor retinaculum within the carpal tunnel with Magnetic Resonance Imaging (MRI) under two conditions: (a) fingers extended, and (b) fingers in an isometric squeeze grip.

Methods

Thirty-Four volunteers participated in this experimental study. The flexor retinaculum and median nerve characteristics were measured during both conditions using MRI.

Results

The isometric squeeze grip condition resulted in significant palmar bowing of the flexor retinaculum (t = 7.67, p<.001), a significant flattening-ratio of the median nerve (t = 4.308, p<.001), and no significant decrease in the cross-sectional area of the median nerve (t = 2.508, p = 0.017).

Conclusion

The isometric squeeze grip condition resulted in anatomical deformations within the carpal tunnel, possibly explained by the lumbrical muscles incursion into the carpal tunnel during finger flexion.  相似文献   

2.

Background

The relationship between focal pulmonary vein potential and atrial fibrillation (AF) has been confirmed. Pulmonary vein (PV) isolation and circumferential pulmonary vein ablation have been the most commonly used procedures of radiofrequency ablation. However, few studies have investigated the relationship between anatomical characteristics of PV and AF recurrences after radiofrequency ablation.

Methodology

For 267 AF patients treated by radiofrequency catheter ablation, the anatomic structure characteristics of pulmonary veins were assessed by multi-slice spiral computed tomography while the values of left atrial diameter (LAD) were measured with transesophageal ultrasonic cardiogram. After radiofrequency catheter ablation, postoperative recurrence was evaluated during a 10-month term follow-up.

Principal Findings

During follow-up, postoperative recurrence occurred in 44 patients. The mean diameters of LAD, left superior PV, right superior PV, all left PV, and all superior PV were significantly larger in patients with postoperative recurrence (Recurrence vs. Non-recurrence group; 43.9 ± 6.4 mm vs. 40.7 ± 5.6 mm; 18.4 ± 2.1 mm vs. 17.1 ± 3.1 mm; 18.2 ± 2.8 mm vs. 17.2 mm ± 3.9 mm; 16.4 ± 1.5 mm vs. 15.6 ± 2.5 mm; 18.3 ± 2.1 mm vs. 17.1 ± 3.0 mm; respectively; all P < 0.05). Multivariable survival analysis showed that the type and the course of AF, LAD, and the diameters of all superior PV were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.

Conclusions

The enlargements of all superior PV and LAD, long course of diseases, and persistent AF were the independent risk factors for the postoperative recurrence after radiofrequency catheter ablation.  相似文献   

3.

Introduction

In cross-sectional studies, patients with rheumatoid arthritis (RA) have higher coronary artery calcium (CAC) than controls. However, their rate of progression of CAC and the predictors of CAC progression have heretofore remained unknown.

Methods

Incidence and progression of CAC were compared in 155 patients with RA and 835 control participants. The association of demographic characteristics, traditional cardiovascular risk factors, RA disease characteristics and selected inflammatory markers with incidence and progression of CAC were evaluated.

Results

The incidence rate of newly detected CAC was 8.2/100 person-years in RA and 7.3/100 person-years in non-RA control subjects [IRR 1.1 (0.7-1.8)]. RA patients who developed newly detectable CAC were older (59±7 vs. 55±6 years old, p=0.03), had higher triglyceride levels (137±86 vs. 97±60 mg/dL, p=0.03), and higher systolic blood pressure (129±17 vs. 117±15 mm Hg, p=0.01) compared to those who did not develop incident CAC. Differences in blood pressure and triglyceride levels remained significant after adjustment for age (p<=0.05). RA patients with any CAC at baseline had a median rate of yearly progression of 21 (7–62) compared to 21 (5–70) Agatston units in controls. No statistical differences between RA progressors and RA non-progressors were observed for inflammatory markers or for RA disease characteristics.

Conclusions

The incidence and progression of CAC did not differ between RA and non-RA participants. In patients with RA, incident CAC was associated with older age, higher triglyceride levels, and higher blood pressure, but not with inflammatory markers or RA disease characteristics.  相似文献   

4.

Background

Treatment of breast fibroadenoma remains a subject of clinical discussion. Recommended methods include clinical observation or surgical excision of the lesion. The procedure involves hospitalisation and anaesthesia, leaving a scar on the breast.

Aim

The aim of this study was to present the Centre''s experience in removing lesions radiologically suspicious of fibroadenoma by means of an ultrasound-guided vacuum-assisted core-needle biopsy as an alternative to a classical surgery.

Materials and methods

Between March 2007 and April 2010, 196 ultrasound-guided vacuum-assisted biopsies were performed in the Mammotome Biopsy Laboratory of the 1st Surgical Oncology and General Surgery Department at the Greater Poland Cancer Centre in Poznań. The procedure was delivered to female patients aged 17–91 years (mean 40.8, median 39). Qualified for removal were ultrasound identified lesions described as fibroadenomas.

Results

The average size of excised lesions according to pre-biopsy ultrasound image was 13.53 ± 8.92 mm (median 11 mm, range 4–60 mm). In 184 cases (93.9%), benign lesions were found in the final histopathologic examination. Pre-cancer lesions were found in 10 cases, and invasive lesions in two cases. Overall, after follow-up ultrasound examination, four patients were qualified for subsequent surgical resection of lesions that had been left behind.

Conclusion

Vacuum core-needle biopsy is an effective tool enabling removal of breast fibroadenomas. It combines features of a lesion resection and histopathologic material collection providing an access with minimum invasiveness.  相似文献   

5.
This study investigated the effects of wrist angle, sex, and handedness on the changes in the median nerve cross-sectional area (MNCSA) and median nerve diameters, namely longitudinal diameter (D1) and vertical diameter (D2). Ultrasound examination was conducted to examine the median nerve at the proximal carpal tunnel in both dominant and nondominant hands of men (n = 27) and women (n = 26). A total of seven wrist angles were examined: neutral; 15°, 30°, and 45° extension; and 15°, 30°, and 45° flexion. Our results indicated sexual dimorphism and bilateral asymmetry of MNCSA, D1 and D2 measurements. MNCSA was significantly reduced when the wrist angle changed from neutral to flexion or extension positions. At flexion positions, D1 was significantly smaller than that at neutral. In contrast, at extension positions, D2 was significantly smaller than that at neutral. In conclusion, this study showed that MNCSA decreased as the wrist angle changed from neutral to flexion or extension positions in both dominant and nondominant hands of both sexes, whereas deformation of the median nerve differed between wrist flexion and extension.  相似文献   

6.

Purpose

To evaluate choroidal thickness (CT) in healthy and glaucomatous eyes using Swept Source Optical Coherence Tomography (SS-OCT).

Methods

A cross-sectional observational study of 216 eyes of 140 subjects with glaucoma and 106 eyes of 67 healthy subjects enrolled in the Diagnostic Innovations in Glaucoma Study. CT was assessed from wide-field (12×9 mm) SS-OCT scans. The association between CT and potential confounding variables including age, gender, axial length, intraocular pressure, central corneal thickness and ocular perfusion pressure was examined using univariable and multivariable regression analyses.

Results

Overall CT was thinner in glaucomatous eyes with a mean (± standard deviation) of 157.7±48.5 µm in glaucoma compared to 179.9±36.1 µm in healthy eyes (P<0.001). The choroid was thinner in both the peripapillary and macular regions in glaucoma compared to controls. Mean peripapillary CT was 154.1±44.1 µm and 134.0±56.9 µm (P<0.001) and macular CT 199.3±46.1 µm and 176.2±57.5 µm (P<0.001) for healthy and glaucomatous eyes respectively. However, older age (P<0.001) and longer axial length (P<0.001) were also associated with thinner choroid and when differences in age and axial length between glaucomatous and healthy subjects were accounted for, glaucoma was not significantly associated with CT. There was also no association between glaucoma severity and CT.

Conclusions

Glaucoma was not associated with CT measured using SS-OCT; however, older age and longer axial length were associated with thinner choroid so should be considered when interpreting CT measurements.  相似文献   

7.

Objective

To test a method for performing electrical impedance myography (EIM) in the mouse hind limb for the assessment of disease status in neuromuscular disease models.

Methods

An impedance measuring device consisting of a frame with electrodes embedded within an acrylic head was developed. The head was rotatable such that data longitudinal and transverse to the major muscle fiber direction could be obtained. EIM measurements were made with this device on 16 healthy mice and 14 amyotrophic lateral sclerosis (ALS) animals. Repeatability was assessed in both groups.

Results

The technique was easy to perform and provided good repeatability in both healthy and ALS animals, with intra-session repeatability (mean ± SEM) of 5% ±1% and 12% ±2%, respectively. Significant differences between healthy and ALS animals were also identified (e.g., longitudinal mean 50 kHz phase was 18±0.6° for the healthy animals and 14±1.0° for the ALS animals, p = 0.0025).

Conclusions

With this simple device, the EIM data obtained is highly repeatable and can differentiate healthy from ALS animals.

Significance

EIM can now be applied to mouse models of neuromuscular disease to assess disease status and the effects of therapy.  相似文献   

8.

Background

Reaction time for anti-saccade, in which the gaze is directed to the position opposite to an illuminated target, shortens during maintenance of neck flexion. The present study applied transcranial magnetic stimulation (TMS) to the frontal oculomotor field, and investigated the effect of maintaining neck flexion on information processing time in the anti-saccade neural pathway before the frontal oculomotor field.

Methods

The reaction time was measured with the chin resting on a stand (‘chin-on’ condition) and with voluntary maintenance of neck flexion (‘chin-off’ condition) at 80% maximal neck flexion angle, with and without TMS. The TMS timing producing the longest prolongation of the reaction time was first roughly identified for 10 ms intervals from 0 to 180 ms after the target presentation. Thereafter, TMS timing was set finely at 2 ms intervals from −20 to +20 ms of the 10 ms step that produced the longest prolongation.

Results

The reaction time without TMS was significantly shorter (21.9 ms) for the chin-off (235.9 ± 14.9 ms) than for the chin-on (257.5 ± 17.1 ms) condition. Furthermore, TMS timing producing maximal prolongation of the reaction time was significantly earlier (18.6 ms) for the chin-off than the chin-on condition. The ratio of the forward shift in TMS timing relative to the reduction in reaction time was 87.8%.

Conclusions

We confirmed that information processing time in the anti-saccade neural pathway before the frontal oculomotor field shortened while neck flexion was maintained, and that this reduction time accounted for approximately 88% of the shortening of reaction time.  相似文献   

9.

Purpose

The study investigated the effects of FIFA 11+ and HarmoKnee, both being popular warm-up programs, on proprioception, and on the static and dynamic balance of professional male soccer players.

Methods

Under 21 year-old soccer players (n = 36) were divided randomly into 11+, HarmoKnee and control groups. The programs were performed for 2 months (24 sessions). Proprioception was measured bilaterally at 30°, 45° and 60° knee flexion using the Biodex Isokinetic Dynamometer. Static and dynamic balances were evaluated using the stork stand test and Star Excursion Balance Test (SEBT), respectively.

Results

The proprioception error of dominant leg significantly decreased from pre- to post-test by 2.8% and 1.7% in the 11+ group at 45° and 60° knee flexion, compared to 3% and 2.1% in the HarmoKnee group. The largest joint positioning error was in the non-dominant leg at 30° knee flexion (mean error value = 5.047), (p<0.05). The static balance with the eyes opened increased in the 11+ by 10.9% and in the HarmoKnee by 6.1% (p<0.05). The static balance with eyes closed significantly increased in the 11+ by 12.4% and in the HarmoKnee by 17.6%. The results indicated that static balance was significantly higher in eyes opened compared to eyes closed (p = 0.000). Significant improvements in SEBT in the 11+ (12.4%) and HarmoKnee (17.6%) groups were also found.

Conclusion

Both the 11+ and HarmoKnee programs were proven to be useful warm-up protocols in improving proprioception at 45° and 60° knee flexion as well as static and dynamic balance in professional male soccer players. Data from this research may be helpful in encouraging coaches or trainers to implement the two warm-up programs in their soccer teams.  相似文献   

10.

Objective

The purpose of this study was to evaluate the morphological changes of upper airway after Twin Block (TB) treatment in growing patients with Class II division 1 malocclusion and mandibular retrusion compared with untreated Class II patients by cone beam computed tomography (CBCT).

Materials and Methods

Thirty growing patients who have completed TB treatment were recruited into TB group. The control group (n = 30) was selected from the patients with the same diagnosis and without TB treatment. CBCT scans of the pre-treatment (T1) and post-treatment (T2) data of TB group and control data were collected. After three-dimensional (3D) reconstruction and registration of T1 and T2 data, the morphological changes of upper airway during TB treatment were measured. The statistical differences between T1 and T2 data of TB group as well as T2 and control data were accessed by t-test.

Results

During the TB treatment, the mandible moved advanced by 3.52±2.14 mm in the horizontal direction and 3.77±2.10 mm in the vertical direction. The hyoid bone was in a more forward and inferior place. The upper airway showed a significant enlargement in nasopharynx, oropharynx and hypopharynx. In addition, the nasopharynx turned more circular, and the oropharynx became more elliptic in transverse shape. However, the transverse shape of the hypopharynx showed no significant difference. After comparison between T2 and control data, only the horizontal movement of the hyoid bone, the volumetric expansion of the oropharynx and hypopharynx, and changes of the oropharyngeal transverse shape showed significant difference.

Conclusion

Compared to the untreated Class II patients, the upper airway of growing patients with Class II division 1 malocclusion and mandibular retrusion showed a significant enlargement in the oropharynx and hypopharynx as well as a more elliptic transverse shape in the oropharynx, and the hyoid bone moved to an anterior position after TB treatment.  相似文献   

11.

Purpose

To evaluate intraocular lens (IOL) tilt and decentration by anterior segment optical coherence tomography (AS-OCT) using 3-dimensional (3D) reconstruction method.

Design

Prospective observational case series.

Participants

Thirty-nine patients (39 eyes) were included.

Methods

The IOL positions of all eyes were examined by AS-OCT. Images were obtained in 4 axes (0–180 degrees, 45–225 degrees, 90–270 degrees, and 135–315 degrees) using the quadrant-scan model. The cross-sectional images were analyzed with MATLAB software.

Main Outcome Measures

The angle (θ) between the reference pupillary plane and the IOL plane, the distances between the center points of the pupil circle and the IOL on the x-axis (dx) and y-axis (dy) and the spatial distance (ds) were calculated after 3D-reconstruction.

Results

The mean angle (θ) between the pupillary plane and the IOL plane was 2.94±0.99 degrees. The mean IOL decentration of dx and dy was 0.32±0.26 mm and 0.40±0.27 mm, respectively. The ds of the IOL decentration was 0.56±0.31 mm. There was no significant correlation between the ocular residual astigmatism (ORA) and the tilted angle or the decentration distance. There was a significant correlation between the ORA and total astigmatism (r = 0.742, P<0.001). There was no significant correlation between the postoperative best corrected visual acuity (BCVA) and the ORA (r = 0.156; P = 0.344), total astigmatism (r = 0.012; P = 0.942), tilted angle (θ; r = 0.172; P = 0.295) or decentration distance (dx: r = 0.191, P = 0.244; dy: r = 0.253, P = 0.121; ds: r = 0.298, P = 0.065).

Conclusions

AS-OCT can be used as an alternative for the analysis of IOL tilt and decentration using 3D-reconstruction.  相似文献   

12.

Aim

To verify the reproducibility of patients irradiated after mastectomy on the immobilization system designed and manufactured for our hospital and to compare the Internal Protocol (IP) with the modified-No Action Level Protocol.

Background

Application of forward IMRT techniques requires a good reproducibility of patient positioning. To minimize the set-up error, an effective immobilization system is important.

Materials and methods

The study was performed for two groups of 65 each. In the first group, portal images for anterior field were taken in 1–3 fractions and, subsequently, three times a week. In this group, the mNAL protocol was used. In the second group, the IP was used. The portal images from the anterior field and from the gantry 0 were taken during the 1–3 and 10 fractions. In both groups, image registration was performed off-line. For each group the systematic and random errors and PTV margin were calculated.

Results

In the first group the value of the population systematic errors and random errors were 1.6 ± 1.6 mm for the left–right, and 1.5 ± 1.7 mm for the cranial–caudal directions, respectively, 1.7 ± 1.3 mm, and 1.9 ± 1.3 mm for the second group. The PTV margins for the left–right and cranial–caudal directions were 5.1 and 4.9 mm for the first group and 5.4 and 6.4 mm for the second group.

Conclusions

For patients immobilized with our support device treated according to the mNAL protocol or IP, a good set-up reproducibility was obtained. Implementation of IP limits the number of required images.  相似文献   

13.

Aim

To analyze intrafraction movement in patients undergoing frameless robotic radiosurgery and evaluate the influence of image acquisition frequency on global accuracy.

Background

Stereotactic radiosurgery requires high spatial accuracy in dose delivery. In conventional radiosurgery, a rigid frame is used to guarantee a correct target alignment and no subsequent movement. Frameless radiosurgery with thermoplastic mask for immobilization cannot completely eliminate intrafraction patient movement. In such cases, it is necessary to evaluate its influence on global treatment accuracy.

Materials and methods

We analyzed the intrafraction motion of the first 15 patients undergoing intracranial radiosurgery (39 fractions) with the CyberKnife VSI system at our institution. Patient position was measured at a 15–90-s interval and was used to estimate intrafraction patient movement.

Results

With our acquisition image protocol and immobilization device, the 99% displacement error was lower than 0.85 mm. The systematic movement components were lower than 0.05 mm and the random component was lower than 0.3 mm in the 3 translational axes. Clear linear time dependence was found in the random component.

Conclusions

Selection of the X-ray image acquisition time is necessary to meet the accuracy required for radiosurgery procedures with the CyberKnife VSI system. We verified that our image acquisition protocol met the 1-mm criterion.  相似文献   

14.

Rationale

There is growing evidence that obstructive sleep apnea is associated with coronary artery disease. However, there are no data on the course of coronary stenosis after percutaneous coronary intervention in patients with obstructive sleep apnea.

Objectives

To determine whether sleep apnea is associated with increased late lumen loss and restenosis after percutaneous coronary intervention.

Methods

78 patients with coronary artery disease who underwent elective percutaneous coronary intervention were divided in 2 groups: 43 patients with an apnea hypopnea – Index < 10/h (group I) and 35 pt. with obstructive sleep apnea and an AHI > 10/h (group II). Late lumen loss, a marker of restenosis, was determined using quantitative coronary angiography after 6.9 ± 3.1 months.

Main results

Angiographic restenosis (>50% luminal diameter), was present in 6 (14%) of group I and in 9 (25%) of group II (p = 0.11). Late lumen loss was significant higher in pt. with an AHI > 10/h (0.7 ± 0.69 mm vs. 0.38 ± 0.37 mm, p = 0.01). Among these 35 patients, 21(60%) used their CPAP devices regularly. There was a marginally lower late lumen loss in treated patients, nevertheless, this difference did not reach statistical significance (0.57 ± 0.47 mm vs. 0.99 ± 0.86 mm, p = 0.08). There was no difference in late lumen loss between treated patients and the group I (p = 0.206).

Conclusion

In summary, patients with OSA and coronary artery disease have a higher degree of late lumen loss, which is a marker of restenosis and vessel remodeling after elective percutaneous intervention.  相似文献   

15.

Objectives

To evaluate the accuracy of advanced non-linear registration of serial lung Computed Tomography (CT) images using Large Deformation Diffeomorphic Metric Mapping (LDDMM).

Methods

Fifteen cases of lung cancer with serial lung CT images (interval: 62.2±26.9 days) were used. After affine transformation, three dimensional, non-linear volume registration was conducted using LDDMM with or without cascading elasticity control. Registration accuracy was evaluated by measuring the displacement of landmarks placed on vessel bifurcations for each lung segment. Subtraction images and Jacobian color maps, calculated from the transformation matrix derived from image warping, were generated, which were used to evaluate time-course changes of the tumors.

Results

The average displacement of landmarks was 0.02±0.16 mm and 0.12±0.60 mm for proximal and distal landmarks after LDDMM transformation with cascading elasticity control, which was significantly smaller than 3.11±2.47 mm and 3.99±3.05 mm, respectively, after affine transformation. Emerged or vanished nodules were visualized on subtraction images, and enlarging or shrinking nodules were displayed on Jacobian maps enabled by highly accurate registration of the nodules using LDDMM. However, some residual misalignments were observed, even with non-linear transformation when substantial changes existed between the image pairs.

Conclusions

LDDMM provides accurate registration of serial lung CT images, and temporal subtraction images with Jacobian maps help radiologists to find changes in pulmonary nodules.  相似文献   

16.

Background

Hernia repair is the most common surgical procedure in the world. Augmentation with synthetic meshes has gained importance in recent decades. Most of the published work about hernia meshes focuses on the surgical technique, outcome in terms of mortality and morbidity and the recurrence rate. Appropriate biomechanical and engineering terminology is frequently absent. Meshes are under continuous development but there is little knowledge in the public domain about their mechanical properties. In the presented experimental study we investigated the mechanical properties of several widely available meshes according to German Industrial Standards (DIN ISO).

Methodology/Principal Findings

Six different meshes were assessed considering longitudinal and transverse direction in a uni-axial tensile test. Based on the force/displacement curve, the maximum force, breaking strain, and stiffness were computed. According to the maximum force the values were assigned to the groups weak and strong to determine a base for comparison. We discovered differences in the maximum force (11.1±6.4 to 100.9±9.4 N/cm), stiffness (0.3±0.1 to 4.6±0.5 N/mm), and breaking strain (150±6% to 340±20%) considering the direction of tension.

Conclusions/Significance

The measured stiffness and breaking strength vary widely among available mesh materials for hernia repair, and most of the materials show significant anisotropy in their mechanical behavior. Considering the forces present in the abdominal wall, our results suggest that some meshes should be implanted in an appropriate orientation, and that information regarding the directionality of their mechanical properties should be provided by the manufacturers.  相似文献   

17.

Purpose

This study aimed to calculate the flexion-extension axis (FEA) of the knee through in-vivo knee kinematics data, and then compare it with two major anatomical axes of the femoral condyles: the transepicondylar axis (TEA) defined by connecting the medial sulcus and lateral prominence, and the cylinder axis (CA) defined by connecting the centers of posterior condyles.

Methods

The knee kinematics data of 20 healthy subjects were acquired under weight-bearing condition using bi-planar x-ray imaging and 3D-2D registration techniques. By tracking the vertical coordinate change of all points on the surface of femur during knee flexion, the FEA was determined as the line connecting the points with the least vertical shift in the medial and lateral condyles respectively. Angular deviation and distance among the TEA, CA and FEA were measured.

Results

The TEA-FEA angular deviation was significantly larger than that of the CA-FEA in 3D and transverse plane (3.45° vs. 1.98°, p < 0.001; 2.72° vs. 1.19°, p = 0.002), but not in the coronal plane (1.61° vs. 0.83°, p = 0.076). The TEA-FEA distance was significantly greater than that of the CA-FEA in the medial side (6.7 mm vs. 1.9 mm, p < 0.001), but not in the lateral side (3.2 mm vs. 2.0 mm, p = 0.16).

Conclusion

The CA is closer to the FEA compared with the TEA; it can better serve as an anatomical surrogate for the functional knee axis.  相似文献   

18.

Purpose

To assess the prevalence of pseudoexfoliation (PEX) and its associations in a population-based setting.

Design

Population-based, cross-sectional study.

Methods

The Central India Eye and Medical Study included 4711 individuals. All study participants underwent a detailed ophthalmological examination. After medical pupil dilation, PEX was assessed by an experienced ophthalmologist using slit-lamp based biomicroscopy.

Results

Slit lamp examination results were available for 4646 (98.6%) study participants with a mean age of 49.3±13.3 years (range: 30–100 years). PEX was detected in 87 eyes (prevalence: 0.95±0.10% (95%CI: 0.75, 1.15) of 69 subjects (prevalence: 1.49±0.18% (95%CI: 1.14, 1.83). PEX prevalence increased significantly (P<0.001) from 0% in the age group of 30–39 years, to 2.85±0.56% in the age group of 60–69 years, to 6.60±1.21% in the age group of 70–79 years, and to 12.3±4.11% in the age group of 80+ years. In multivariate analysis, PEX prevalence was associated with higher age (P<0.001; regression coefficient B:0.11; odds ratio (OR): 1.11 (95%CI: 1.09, 1.13)), lower body mass index (P = 0.001; B: −0.12; OR: 0.88 (95CI: 0.82, 0.95)) and higher diastolic blood pressure (P = 0.002; B: 0.02; OR: 1.03 (95%CI: 1.01, 1.04)). In the multivariate analysis, PEX was not associated with retinal nerve fiber layer cross section area (P = 0.76) and presence of open-angle glaucoma (P = 0.15).

Conclusions

In a rural Central Indian population aged 30+ years, PEX prevalence (mean: 1.49±0.18%) was significantly associated with older age, lower body mass index and higher diastolic blood pressure. It was not significantly associated with optic nerve head measurements, refractive error, any ocular biometric parameter, nuclear cataract, early age-related macular degeneration and retinal vein occlusion, diabetes mellitus, smoking, and dyslipidemia.  相似文献   

19.

Background

To achieve decreased invasiveness and lower morbidity, minimally invasive esophagectomy (MIE) was introduced in 1997 for localized esophageal cancer. The combined thoracoscopic-laparoscopic esophagectomy (left neck anastomosis, defined as the McKeown MIE procedure) has been performed since 2007 at our institution. From 2007 to 2011, our institution subsequently evolved as a high-volume MIE center in China. We aim to share our experience with MIE, and have evaluated the outcomes of 142 patients.

Methods

We retrospectively reviewed 142 consecutive patients who had presented with esophageal cancer undergoing McKeown MIE from July 2007 to December 2011. The procedure, surgical outcomes, disease-free and overall survival of these cases were assessed.

Results

The average total procedure time was 270.5±28.1 min. The median operation time for thoracoscopy was 81.5±14.6 min and for laparoscopy was 63.8±9.1 min. The average blood loss associated with thoracoscopy was 123.8±39.2 ml, and for laparoscopic procedures was 49.9±14.3 ml. The median number of lymph nodes retrieved was 22.8. The 30 day mortality rate was 0.7%. Major surgical complications occurred in 24.6% and major non-surgical complications occurred in 18.3% of these patients. The median DFS and OS were 36.0±2.6 months and 43.0±3.4 months respectively.

Conclusions

Surgical and oncological outcomes following McKeown MIE for esophageal cancer were acceptable and comparable with those of open-McKeown esophagectomy. The procedure was both feasible and safe – properties that can be consolidated by experience.  相似文献   

20.

Objective

To report normative data for retinal thickness in wild-type C57BL/6 mouse utilizing a miniature SD-OCT system.

Methods

Thirty adult mice (range: 3–5 months) were anesthetized and secured into the Bioptigen Spectral Domain Ophthalmic Imaging System. Right eye SD-OCT images were standardized by centralizing the optic nerve head (ONH) prior to image acquisition. Global and quadrant total retinal thickness (TRT) values were measured from retinal nerve fiber layer to retinal pigment epithelial layer. Posterior segment analyses also included the outer retinal layer (ORL) and inner retinal layer (IRL). Further sublayer analyses of four layers from the ORL and three layers comprising the IRL were also performed.

Results

The overall mean±SD global TRT in a C57BL/6 mouse model was 204.41±5.19 µm. Quadrant mean TRT values were 204.85±5.81 µm inferiorly, 204.97±6.71 µm nasally, 205.08±5.44 µm temporally, and 202.74±4.85 µm superiorly. Mean±SD thickness for ORL, and IRL were 126.37±10.01 µm, and 107.03±10.98 µm respectively. The mean±SD estimates for the four layers of the ORL were 18.23±2.73 µm, 26.04±4.21 µm, 63.8±6.23 µm, and 19.22±4.34 µm. Mean±SD values for the three IRL sublayers were 27.82±4.04 µm, 59.62±6.66 µm and 19.12±3.71 µm.

Conclusion

This study established normative values for the total retinal thickness and sublayer thickness for the wild-type C57BL/6 mice. Moreover, it provides a standard of retinal morphology, in a commonly used animal model, for evaluating therapeutic interventions and retinal disease pathophysiology.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏