首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 345 毫秒
1.
Fundamental improvement was made for genome sequencing since the next-generation sequencing (NGS) came out in the 2000s. The newer technologies make use of the power of massively-parallel short-read DNA sequencing, genome alignment and assembly methods to digitally and rapidly search the genomes on a revolutionary scale, which enable large-scale whole genome sequencing (WGS) accessible and practical for researchers. Nowadays, whole genome sequencing is more and more prevalent in detecting the genetics of diseases, studying causative relations with cancers, making genome-level comparative analysis, reconstruction of human population history, and giving clinical implications and instructions. In this review, we first give a typical pipeline of whole genome sequencing, including the lab template preparation, sequencing, genome assembling and quality control, variants calling and annotations. We compare the difference between whole genome and whole exome sequencing (WES), and explore a wide range of applications of whole genome sequencing for both mendelian diseases and complex diseases in medical genetics. We highlight the impact of whole genome sequencing in cancer studies, regulatory variant analysis, predictive medicine and precision medicine, as well as discuss the challenges of the whole genome sequencing.   相似文献   

2.
3.
The application of next-generation sequencing (NGS) technology in cancer is influenced by the quality and purity of tissue samples. This issue is especially critical for patient-derived xenograft (PDX) models, which have proven to be by far the best preclinical tool for investigating human tumor biology, because the sensitivity and specificity of NGS analysis in xenograft samples would be compromised by the contamination of mouse DNA and RNA. This definitely affects downstream analyses by causing inaccurate mutation calling and gene expression estimates. The reliability of NGS data analysis for cancer xenograft samples is therefore highly dependent on whether the sequencing reads derived from the xenograft could be distinguished from those originated from the host. That is, each sequence read needs to be accurately assigned to its original species. Here, we review currently available methodologies in this field, including Xenome, Disambiguate, bamcmp and pdxBlacklist, and provide guidelines for users.  相似文献   

4.
The congenital muscular dystrophies (CMDs) comprise a heterogeneous group of heritable muscle disorders with often difficult to interpret muscle pathology, making them challenging to diagnose. Serial Sanger sequencing of suspected CMD genes, while the current molecular diagnostic method of choice, can be slow and expensive. A comprehensive panel test for simultaneous screening of mutations in all known CMD-associated genes would be a more effective diagnostic strategy. Thus, the CMDs are a model disorder group for development and validation of next-generation sequencing (NGS) strategies for diagnostic and clinical care applications. Using a highly multiplexed PCR-based target enrichment method (RainDance) in conjunction with NGS, we performed mutation detection in all CMD genes of 26 samples and compared the results with Sanger sequencing. The RainDance NGS panel showed great consistency in coverage depth, on-target efficiency, versatility of mutation detection, and genotype concordance with Sanger sequencing, demonstrating the test''s appropriateness for clinical use. Compared to single tests, a higher diagnostic yield was observed by panel implementation. The panel''s limitation is the amplification failure of select gene-specific exons which require Sanger sequencing for test completion. Successful validation and application of the CMD NGS panel to improve the diagnostic yield in a clinical laboratory was shown.  相似文献   

5.
Next-generation sequencing (NGS) technologies have transformed genomic research and have the potential to revolutionize clinical medicine. However, the background error rates of sequencing instruments and limitations in targeted read coverage have precluded the detection of rare DNA sequence variants by NGS. Here we describe a method, termed CypherSeq, which combines double-stranded barcoding error correction and rolling circle amplification (RCA)-based target enrichment to vastly improve NGS-based rare variant detection. The CypherSeq methodology involves the ligation of sample DNA into circular vectors, which contain double-stranded barcodes for computational error correction and adapters for library preparation and sequencing. CypherSeq is capable of detecting rare mutations genome-wide as well as those within specific target genes via RCA-based enrichment. We demonstrate that CypherSeq is capable of correcting errors incurred during library preparation and sequencing to reproducibly detect mutations down to a frequency of 2.4 × 10−7 per base pair, and report the frequency and spectra of spontaneous and ethyl methanesulfonate-induced mutations across the Saccharomyces cerevisiae genome.  相似文献   

6.
In the last decade, there has been a flood of new technology in the sequencing arena. The onset of next-generation sequencing (NGS) technology has resulted in the vast increase in genetic diagnostic testing available to the ordering physician. Whole exome sequencing (WES) has become available as a diagnostic test performed in certified clinical laboratories. This has led to increased presence in the diagnostic marketplace, increased consumer awareness, and the question has been raised by various stakeholders to whether there is sufficient stringent regulation of WES and other NGS-based tests. We discuss the various WES services currently available in the marketplace, current regulation of WES as a laboratory developed test, the proposed FDA involvement in its oversight as well as the response of various laboratory groups that provide these diagnostic services. Overall, a rigorous process oversight and assessment of inter-lab reproducibility is strongly warranted for WES as it is used as a diagnostic test, but regulation should be mindful of the excessive administrative burden on academic and smaller diagnostic laboratories.  相似文献   

7.

Background

Cancer immunotherapy has recently entered a remarkable renaissance phase with the approval of several agents for treatment. Cancer treatment platforms have demonstrated profound tumor regressions including complete cure in patients with metastatic cancer. Moreover, technological advances in next-generation sequencing (NGS) as well as the development of devices for scanning whole-slide bioimages from tissue sections and image analysis software for quantitation of tumor-infiltrating lymphocytes (TILs) allow, for the first time, the development of personalized cancer immunotherapies that target patient specific mutations. However, there is currently no bioinformatics solution that supports the integration of these heterogeneous datasets.

Results

We have developed a bioinformatics platform – Personalized Oncology Suite (POS) – that integrates clinical data, NGS data and whole-slide bioimages from tissue sections. POS is a web-based platform that is scalable, flexible and expandable. The underlying database is based on a data warehouse schema, which is used to integrate information from different sources. POS stores clinical data, genomic data (SNPs and INDELs identified from NGS analysis), and scanned whole-slide images. It features a genome browser as well as access to several instances of the bioimage management application Bisque. POS provides different visualization techniques and offers sophisticated upload and download possibilities. The modular architecture of POS allows the community to easily modify and extend the application.

Conclusions

The web-based integration of clinical, NGS, and imaging data represents a valuable resource for clinical researchers and future application in medical oncology. POS can be used not only in the context of cancer immunology but also in other studies in which NGS data and images of tissue sections are generated. The application is open-source and can be downloaded at http://www.icbi.at/POS.

Electronic supplementary material

The online version of this article (doi:10.1186/1471-2105-15-306) contains supplementary material, which is available to authorized users.  相似文献   

8.
Available clinical human papilloma virus (HPV) diagnostics for head and neck cancer have limited sensitivity and/or fail to define the HPV genotype. Common HPV genotyping assays are costly and labor intensive. We sought to develop a next-generation sequencing (NGS)-based HPV genotyping assay that was sensitive enough to work on formalin-fixed paraffin-embedded (FFPE) samples. We developed an ion torrent NGS HPV genotyping assay using barcoded HPV PCR broad-spectrum general primers 5+/6+ (BSGP)5+/6+. To validate genotype specificity and use in archived clinical FFPE tumor samples, we compared NGS HPV genotyping at 2 sequencing centers with typing by Roche Linear Array assay in 42 oropharyngeal and cervical cancer specimens representing 10 HPV genotypes, as well as HPV-negative cases. To demonstrate the detection of a broad range of HPV genotypes, we genotyped a cohort of 266 cervical cancers. A comparison of NGS genotyping of FFPE cancer specimens with genotyping by Linear Array showed concordant results in 34/37 samples (92%) at sequencing site 1 and 39/42 samples (93%) at sequencing site 2. Concordance between sites was 92%. Designed for use with 10 ng genomic DNA, the assay detected HPV using as little as 1.25 ng FFPE-derived genomic DNA. In 266 cervical cancer specimens, the NGS assay identified 20 different HPV genotypes, including all 13 carcinogenic genotypes. This novel NGS assay provides a sensitive and specific high-throughput method to detect and genotype HPV in a range of clinical specimens derived from FFPE with low per-sample cost.  相似文献   

9.
外显子组测序是针对基因组中的蛋白质编码区,靶向富集外显子区域测序,以发现疾病相关遗传变异的技术。该技术近年越来越多地应用于发现人类基因组低频变异、鉴定单基因遗传病致病基因和肿瘤等复杂疾病易感基因研究,成为人类疾病相关变异研究的重要工具。综述了外显子组测序技术的基本原理及其在人类疾病相关基因研究中的应用。  相似文献   

10.
王翠翠  袁慧军 《遗传》2017,39(3):208-219
耳聋是一种常见的严重出生缺陷,阐明遗传性耳聋的致病机理不仅能够在临床上辅助诊断,为遗传咨询及耳聋预防提供依据,而且能促进人们更深入地了解耳聋的致病机制,开发新的治疗方法。随着基因组研究技术不断创新,以全基因组测序、全外显子组测序、目标区域测序为代表的高通量测序技术在遗传性耳聋研究中已得到广泛应用。本文总结了近5年全外显子组测序和目标区域测序在遗传性耳聋致病基因研究及临床分子诊断中应用及研究进展,希望能够有助于我国临床耳聋基因诊断技术的发展及诊断水平的提升。  相似文献   

11.
Zhu  Fangfang  Li  Jiang  Liu  Juan  Min  Wenwen 《BMC genetics》2021,22(1):1-10
Background

Next-generation sequencing (NGS) has profoundly changed the approach to genetic/genomic research. Particularly, the clinical utility of NGS in detecting mutations associated with disease risk has contributed to the development of effective therapeutic strategies. Recently, comprehensive analysis of somatic genetic mutations by NGS has also been used as a new approach for controlling the quality of cell substrates for manufacturing biopharmaceuticals. However, the quality evaluation of cell substrates by NGS largely depends on the limit of detection (LOD) for rare somatic mutations. The purpose of this study was to develop a simple method for evaluating the ability of whole-exome sequencing (WES) by NGS to detect mutations with low allele frequency. To estimate the LOD of WES for low-frequency somatic mutations, we repeatedly and independently performed WES of a reference genomic DNA using the same NGS platform and assay design. LOD was defined as the allele frequency with a relative standard deviation (RSD) value of 30% and was estimated by a moving average curve of the relation between RSD and allele frequency.

Results

Allele frequencies of 20 mutations in the reference material that had been pre-validated by droplet digital PCR (ddPCR) were obtained from 5, 15, 30, or 40 G base pair (Gbp) sequencing data per run. There was a significant association between the allele frequencies measured by WES and those pre-validated by ddPCR, whose p-value decreased as the sequencing data size increased. By this method, the LOD of allele frequency in WES with the sequencing data of 15 Gbp or more was estimated to be between 5 and 10%.

Conclusions

For properly interpreting the WES data of somatic genetic mutations, it is necessary to have a cutoff threshold of low allele frequencies. The in-house LOD estimated by the simple method shown in this study provides a rationale for setting the cutoff.

  相似文献   

12.
Delay in cancer diagnosis often results in metastasis and an inability to successfully treat the tumor. The use of broadly cancer-specific biomarkers at an early stage may improve cancer treatment and staging. This study has explored circulatory exosomal miRNAs as potential diagnostic biomarkers to identify cancer patients. Secretory exosomal miRNAs were isolated from 13 canine cancer cell lines (lymphoma, mast cell tumor, histiocytic cell line, osteosarcoma, melanoma, and breast tumor) and were sequenced by Next-Generation sequencing (NGS). We have identified 6 miRNAs (cfa-miR-9, -1841, ?1306, ?345, ?132, and ?26b) by NGS that were elevated in all cancer cell types. The miRNAs identified by NGS were then examined by Q-RT-PCR. The PCR data demonstrated similar expression patterns to those seen with NGS but provided fold differences that were much lower than those seen for NGS. Cfa-miR-9 was found to be the most consistently elevated miRNA in NGS and PCR, making it the most likely miRNA to prove diagnostic. In this study, we have demonstrated that it is possible to identify exosomal miRNAs with elevated secretion across multiple tumor types that could be used as circulatory diagnostic biomarkers for liquid biopsy in the future.  相似文献   

13.
As our understanding of the driver mutations necessary for initiation and progression of cancers improves, we gain critical information on how specific molecular profiles of a tumor may predict responsiveness to therapeutic agents or provide knowledge about prognosis. At our institution a tumor genotyping program was established as part of routine clinical care, screening both hematologic and solid tumors for a wide spectrum of mutations using two next-generation sequencing (NGS) panels: a custom, 33 gene hematological malignancies panel for use with peripheral blood and bone marrow, and a commercially produced solid tumor panel for use with formalin-fixed paraffin-embedded tissue that targets 47 genes commonly mutated in cancer. Our workflow includes a pathologist review of the biopsy to ensure there is adequate amount of tumor for the assay followed by customized DNA extraction is performed on the specimen. Quality control of the specimen includes steps for quantity, quality and integrity and only after the extracted DNA passes these metrics an amplicon library is generated and sequenced. The resulting data is analyzed through an in-house bioinformatics pipeline and the variants are reviewed and interpreted for pathogenicity. Here we provide a snapshot of the utility of each panel using two clinical cases to provide insight into how a well-designed NGS workflow can contribute to optimizing clinical outcomes.  相似文献   

14.
15.
脓毒血症是一种严重威胁生命的感染,精准、快速的病原学诊断可帮助临床医师优化抗菌药物的使用。目前,基于病原菌培养的方法仍是脓毒血症病原学诊断的主要手段,但具有耗时长、灵敏度低等不可忽视的缺点。近年来出现了一些不依赖培养的病原学诊断方法,其中基于聚合酶链反应(polymerase chain reaction,PCR)的方法已发展较为成熟。但PCR只能检测已知的特定病原体,临床定量PCR仅用于检测病毒及少数细菌,脓毒血症中的病原体PCR多仅为定性检测。目前,二代测序技术不断成熟并用于临床,成为病原学诊断的有力手段。与血培养等传统病原学检测方法相比,其具有快速、非选择性、可定量或半定量分析的优点。现阶段二代测序仍存在公认判读标准缺乏、测序结果与治疗关系不明确、耐药基因检测困难等不足,亦缺乏较大规模的二代测序与传统诊断方法比较验证的研究结果,尚有待更高级的循证医学证据支持。  相似文献   

16.

Background

One of the most significant issues surrounding next generation sequencing is the cost and the difficulty assembling short read lengths. Targeted capture enrichment of longer fragments using single molecule sequencing (SMS) is expected to improve both sequence assembly and base-call accuracy but, at present, there are very few examples of successful application of these technologic advances in translational research and clinical testing. We developed a targeted single molecule sequencing (T-SMS) panel for genes implicated in ovarian response to controlled ovarian hyperstimulation (COH) for infertility.

Results

Target enrichment was carried out using droplet-base multiplex polymerase chain reaction (PCR) technology (RainDance®) designed to yield amplicons averaging 1 kb fragment size from candidate 44 loci (99.8% unique base-pair coverage). The total targeted sequence was 3.18 Mb per sample. SMS was carried out using single molecule, real-time DNA sequencing (SMRT® Pacific Biosciences®), average raw read length = 1178 nucleotides, 5% of the amplicons >6000 nucleotides). After filtering with circular consensus (CCS) reads, the mean read length was 3200 nucleotides (97% CCS accuracy). Primary data analyses, alignment and filtering utilized the Pacific Biosciences® SMRT portal. Secondary analysis was conducted using the Genome Analysis Toolkit for SNP discovery l and wANNOVAR for functional analysis of variants. Filtered functional variants 18 of 19 (94.7%) were further confirmed using conventional Sanger sequencing. CCS reads were able to accurately detect zygosity. Coverage within GC rich regions (i.e.VEGFR; 72% GC rich) was achieved by capturing long genomic DNA (gDNA) fragments and reading into regions that flank the capture regions. As proof of concept, a non-synonymous LHCGR variant captured in two severe OHSS cases, and verified by conventional sequencing.

Conclusions

Combining emulsion PCR-generated 1 kb amplicons and SMRT DNA sequencing permitted greater depth of coverage for T-SMS and facilitated easier sequence assembly. To the best of our knowledge, this is the first report combining emulsion PCR and T-SMS for long reads using human DNA samples, and NGS panel designed for biomarker discovery in OHSS.

Electronic supplementary material

The online version of this article (doi:10.1186/s12864-015-1451-2) contains supplementary material, which is available to authorized users.  相似文献   

17.
采用二代和三代测序技术分别对金针菇单核体菌株“6-3”进行测序,应用4种组装策略进行基因组的de novo组装,对比组装效果。基因组组装的参数方面,仅使用二代测序组装的效果最差,长度大于10kb的Contig全长只有24.6Mb,Contig N50只有23kb,组装率只有59.27%。采用三代组装二代校正的组装策略效果最好,长度大于10kb的Contig全长为38.3Mb,Contig N50为2.8Mb,组装率高达92.16%。保守单拷贝基因拼接效果方面,4种组装策略获得基因组序列与BUSCO数据库里的担子菌的保守单拷贝基因比对,基因完整性均大于94%。在组装准确性方面,经过PCR扩增、Sanger测序验证,三代组装二代校正的基因组序列完整并且连续,同时序列上碱基的SNP、InDel数量最少。综上所述,三代组装二代校正得到的基因组序列具有Contig N50值大、组装率高、碱基准确性高的特点,是食用菌基因组测序较为理想的方案。  相似文献   

18.
19.
Next-generation sequencing of cell-free circulating solid tumor DNA addresses two challenges in contemporary cancer care. First this method of massively parallel and deep sequencing enables assessment of a comprehensive panel of genomic targets from a single sample, and second, it obviates the need for repeat invasive tissue biopsies. Digital SequencingTM is a novel method for high-quality sequencing of circulating tumor DNA simultaneously across a comprehensive panel of over 50 cancer-related genes with a simple blood test. Here we report the analytic and clinical validation of the gene panel. Analytic sensitivity down to 0.1% mutant allele fraction is demonstrated via serial dilution studies of known samples. Near-perfect analytic specificity (> 99.9999%) enables complete coverage of many genes without the false positives typically seen with traditional sequencing assays at mutant allele frequencies or fractions below 5%. We compared digital sequencing of plasma-derived cell-free DNA to tissue-based sequencing on 165 consecutive matched samples from five outside centers in patients with stage III-IV solid tumor cancers. Clinical sensitivity of plasma-derived NGS was 85.0%, comparable to 80.7% sensitivity for tissue. The assay success rate on 1,000 consecutive samples in clinical practice was 99.8%. Digital sequencing of plasma-derived DNA is indicated in advanced cancer patients to prevent repeated invasive biopsies when the initial biopsy is inadequate, unobtainable for genomic testing, or uninformative, or when the patient’s cancer has progressed despite treatment. Its clinical utility is derived from reduction in the costs, complications and delays associated with invasive tissue biopsies for genomic testing.  相似文献   

20.
Next‐generation sequencing (NGS) is increasingly used for diet analyses; however, it may not always describe diet samples well. A reason for this is that diet samples contain mixtures of food DNA in different amounts as well as consumer DNA which can reduce the food DNA characterized. Because of this, detections will depend on the relative amount and identity of each type of DNA. For such samples, diagnostic PCR will most likely give more reliable results, as detection probability is only marginally dependent on other copresent DNA. We investigated the reliability of each method to test (a) whether predatory beetle regurgitates, supposed to be low in consumer DNA, allow to retrieve prey sequences using general barcoding primers that co‐amplify the consumer DNA, and (b) to assess the sequencing depth or replication needed for NGS and diagnostic PCR to give stable results. When consumer DNA is co‐amplified, NGS is better suited to discover the range of possible prey, than for comparing co‐occurrences of diet species between samples, as retested samples were repeatedly different in prey detections with this approach. This shows that samples were incompletely described, as prey detected by diagnostic PCR frequently were missed by NGS. As the sequencing depth needed to reliably describe the diet in such samples becomes very high, the cost‐efficiency and reliability of diagnostic PCR make diagnostic PCR better suited for testing large sample‐sets. Especially if the targeted prey taxa are thought to be of ecological importance, as diagnostic PCR gave more nested and consistent results in repeated testing of the same sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号