首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 375 毫秒
1.
《IRBM》2022,43(5):325-332
ObjectiveIn cardiac patient-care, compression of long-term ECG data is essential to minimize the data storage requirement and transmission cost. Hence, this paper presents a novel electrocardiogram data compression technique which utilizes modified run-length encoding of wavelet coefficients.MethodFirst, wavelet transform is applied to the ECG data which decomposes it and packs maximum energy to less number of transform coefficients. The wavelet transform coefficients are quantized using dead-zone quantization. It discards small valued coefficients lying in the dead-zone interval while other coefficients are kept at the formulated quantized output interval. Among all the quantized coefficients, an average value is assigned to those coefficients for which energy packing efficiency is less than 99.99%. The obtained coefficients are encoded using modified run-length coding. It offers higher compression ratio than conventional run-length coding without any loss of information.ResultsCompression performance of the proposed technique is evaluated using different ECG records taken from the MIT-BIH arrhythmia database. The average compression performance in terms of compression ratio, percent root mean square difference, normalized percent mean square difference, and signal to noise ratio are 17.18, 3.92, 6.36, and 28.27 dB respectively for 48 ECG records.ConclusionThe compression results obtained by the proposed technique is better than techniques recently introduced by others. The proposed technique can be utilized for compression of ECG records of Holter monitoring.  相似文献   

2.
This paper presents a new ECG denoising approach based on noise reduction algorithms in empirical mode decomposition (EMD) and discrete wavelet transform (DWT) domains. Unlike the conventional EMD based ECG denoising approaches that neglect a number of initial intrinsic mode functions (IMFs) containing the QRS complex as well as noise, we propose to perform windowing in the EMD domain in order to reduce the noise from the initial IMFs instead of discarding them completely thus preserving the QRS complex and yielding a relatively cleaner ECG signal. The signal thus obtained is transformed in the DWT domain, where an adaptive soft thresholding based noise reduction algorithm is employed considering the advantageous properties of the DWT compared to that of the EMD in preserving the energy in the presence of noise and in reconstructing the original ECG signal with a better time resolution. Extensive simulations are carried out using the MIT-BIH arrythmia database and the performance of the proposed method is evaluated in terms of several standard metrics. The simulation results show that the proposed method is able to reduce noise from the noisy ECG signals more accurately and consistently in comparison to some of the stateof-the-art methods.  相似文献   

3.
Electrocardiogram (ECG) compression can significantly reduce the storage and transmission burden for the long-term recording system and telemedicine applications. In this paper, an improved wavelet-based compression method is proposed. A discrete wavelet transform (DWT) is firstly applied to the mean removed ECG signal. DWT coefficients in a hierarchical tree order are taken as the component of a vector named tree vector (TV). Then, the TV is quantized with a vector–scalar quantizer (VSQ), which is composed of a dynamic learning vector quantizer and a uniform scalar dead-zone quantizer. The context modeling arithmetic coding is finally employed to encode those quantized coefficients from the VSQ. All tested records are selected from the Massachusetts Institute of Technology-Beth Israel Hospital arrhythmia database. Statistical results show that the compression performance of the proposed method outperforms several published compression algorithms.  相似文献   

4.
《IRBM》2020,41(3):161-171
BackgroundThe voice is a prominent tool allowing people to communicate and to change information in their daily activities. However, any slight alteration in the voice production system may affect the voice quality. Over the last years, researchers in biomedical engineering field worked to develop a robust automatic system that may help clinicians to perform a preventive diagnosis in order to detect the voice pathologies in an early stage.MethodIn this context, pathological voice detection and classification method based on EMD-DWT analysis and Higher Order Statistics (HOS) features, is proposed. Also DWT coefficients features are extracted and tested. To carry out our experiments a wide subset of voice signal from normal subjects and subjects which suffer from the five most frequent pathologies in the Saarbrücken Voice Database (SVD), is selected. In The first step, we applied the Empirical Mode Decomposition (EMD) to the voice signal. Afterwards, among the obtained candidates of Intrinsic Mode Functions (IMFs), we choose the robust one based on temporal energy criterion. In the second step, the selected IMF was decomposed via the Discrete Wavelet Transform (DWT). As a result, two features vector includes six HOSs parameters, and a features vector includes six DWT features were formed from both approximation and detail coefficients. In order to classify the obtained data a support vector machine (SVM) is employed. After having trained the proposed system using the SVD database, the system was evaluated using voice signals of volunteer's subjects from the Neurological department of RABTA Hospital of Tunis.ResultsThe proposed method gives promising results in pathological voices detection. The accuracies reached 99.26% using HOS features and 93.1% using DWT features for SVD database. In the classification, an accuracy of 100% was reached for “Funktionelle Dysphonia vs. Rekrrensparese” based on HOS features. Nevertheless, using DWT features the accuracy achieved was 90.32% for “Hyperfunktionelle Dysphonia vs. Rekurrensparse”. Furthermore, in the validation the accuracies reached were 94.82%, 91.37% for HOS and DWT features, respectively. In the classification the highest accuracies reached were for classifying “Parkinson versus Paralysis” 94.44% and 88.87% based on HOS and DWT features, respectively.ConclusionHOS features show promising results in the automatic voice pathology detection and classification compared to DWT features. Thus, it can reliably be used as noninvasive tool to assist clinical evaluation for pathological voices identification.  相似文献   

5.
In recent years, the removal of electrocardiogram (ECG) interferences from electromyogram (EMG) signals has been given large consideration. Where the quality of EMG signal is of interest, it is important to remove ECG interferences from EMG signals. In this paper, an efficient method based on a combination of adaptive neuro-fuzzy inference system (ANFIS) and wavelet transform is proposed to effectively eliminate ECG interferences from surface EMG signals. The proposed approach is compared with other common methods such as high-pass filter, artificial neural network, adaptive noise canceller, wavelet transform, subtraction method and ANFIS. It is found that the performance of the proposed ANFIS–wavelet method is superior to the other methods with the signal to noise ratio and relative error of 14.97 dB and 0.02 respectively and a significantly higher correlation coefficient (p < 0.05).  相似文献   

6.
《IRBM》2020,41(1):58-70
ObjectivesObjective of this paper is to present a reliable and accurate technique for Myocardial Infarction (MI) detection and localization.Material and methodsStationary wavelet transform has been used to decompose the ECG signal. Energy, entropy and slope based features were extracted at specific wavelet bands from selected lead of ECG. k-Nearest Neighbors (kNN) with Mahalanobis distance function has been used for classification. Sensitivity (Se), specificity (Sp), positive predictivity (+P), accuracy (Acc), and area under the receiver operating characteristics curve (AUC) analyzed over 200 subjects (52 health control, 148 with MI) from Physikalisch-Technische Bundesanstalt (PTB) database has been used for performance analysis. To handle the imbalanced data adaptive synthetic (ADASYN) sampling approach has been adopted.ResultsFor detection of MI, the proposed technique has shown an AUC = 0.99, Se = 98.62%, Sp = 99.40%, PPR = 99.41% and Acc = 99.00% using 12 top ranked features, extracted from multiple leads of ECG and AUC = 0.99, Se = 98.34%, Sp = 99.77%, PPR = 99.77% and Acc = 99.05% using 12 features extracted from a single ECG lead (i.e. lead V5). For localization of MI, the proposed technique has an AUC = 0.99, Se = 98.78%, Sp = 99.86%, PPR = 98.80%, and Acc = 99.76% using 5 top ranked features from multiple leads of ECG and AUC = 0.98, Se = 96.47%, Sp = 99.60%, PPR = 96.49% and Acc = 99.28% using 8 features extracted from a single ECG lead (i.e. lead V3).ConclusionThus for MI detection and localization, the proposed technique is independent of time-domain ECG fiducial markers and can work using specific leads of ECG.  相似文献   

7.
Y. Slim  K. Raoof 《IRBM》2010,31(4):209-220
The signal to noise ratio (SNR) of surface respiratory electromyography signal is very low. Indeed EMG signal is contaminated by different types of noise especially the cardiac artefact ECG. This article explores the problem of removing ECG artefact from respiratory EMG signal. The new method uses an adaptive structure with an electrocardyographic ECG reference signal carried out by wavelet decomposition. The proposed algorithm requires only one channel to both estimating the adaptive filter input reference noise and the respiratory EMG signal. This new technique demonstrates how two steps will be combined: the first step decomposes the signal with forward discrete wavelet transform into sub-bands to get the wavelet coefficients. Then, an improved soft thresholding function was applied. And the ECG input reference signal is reconstructed with the transformed coefficients whereas, the second uses an adaptive filter especially the LMS one to remove the ECG signal. After trying statistical as well as mathematical analysis, the complete investigation ensures that all details and steps make proof that our rigorous method is appropriate. Compared to the results obtained using previous techniques, the results achieved using the new algorithm show a significant improvement in the efficiency of the ECG rejection.  相似文献   

8.
基于小波变换的混合二维ECG数据压缩方法   总被引:5,自引:0,他引:5  
提出了一种新的基于小波变换的混合二维心电(electrocardiogram,ECG)数据压缩方法。基于ECG数据的两种相关性,该方法首先将一维ECG信号转化为二维信号序列。然后对二维序列进行了小波变换,并利用改进的编码方法对变换后的系数进行了压缩编码:即先根据不同系数子带的各自特点和系数子带之间的相似性,改进了等级树集合分裂(setpartitioninghierarchicaltrees,SPIHT)算法和矢量量化(vectorquantization,VQ)算法;再利用改进后的SPIHT与VQ相混合的算法对小波变换后的系数进行了编码。利用所提算法与已有具有代表性的基于小波变换的压缩算法和其他二维ECG信号的压缩算法,对MIT/BIH数据库中的心律不齐数据进行了对比压缩实验。结果表明:所提算法适用于各种波形特征的ECG信号,并且在保证压缩质量的前提下,可以获得较大的压缩比。  相似文献   

9.
Hydrological time series forecasting remains a difficult task due to its complicated nonlinear, non-stationary and multi-scale characteristics. To solve this difficulty and improve the prediction accuracy, a novel four-stage hybrid model is proposed for hydrological time series forecasting based on the principle of ‘denoising, decomposition and ensemble’. The proposed model has four stages, i.e., denoising, decomposition, components prediction and ensemble. In the denoising stage, the empirical mode decomposition (EMD) method is utilized to reduce the noises in the hydrological time series. Then, an improved method of EMD, the ensemble empirical mode decomposition (EEMD), is applied to decompose the denoised series into a number of intrinsic mode function (IMF) components and one residual component. Next, the radial basis function neural network (RBFNN) is adopted to predict the trend of all of the components obtained in the decomposition stage. In the final ensemble prediction stage, the forecasting results of all of the IMF and residual components obtained in the third stage are combined to generate the final prediction results, using a linear neural network (LNN) model. For illustration and verification, six hydrological cases with different characteristics are used to test the effectiveness of the proposed model. The proposed hybrid model performs better than conventional single models, the hybrid models without denoising or decomposition and the hybrid models based on other methods, such as the wavelet analysis (WA)-based hybrid models. In addition, the denoising and decomposition strategies decrease the complexity of the series and reduce the difficulties of the forecasting. With its effective denoising and accurate decomposition ability, high prediction precision and wide applicability, the new model is very promising for complex time series forecasting. This new forecast model is an extension of nonlinear prediction models.  相似文献   

10.
Assessment of neuromuscular fatigue is essential for early detection and prevention of risks associated with work-related musculoskeletal disorders. In recent years, discrete wavelet transform (DWT) of surface electromyography (SEMG) has been used to evaluate muscle fatigue, especially during dynamic contractions when the SEMG signal is non-stationary. However, its application to the assessment of work-related neck and shoulder muscle fatigue is not well established. Therefore, the purpose of this study was to establish DWT analysis as a suitable method to conduct quantitative assessment of neck and shoulder muscle fatigue under dynamic repetitive conditions. Ten human participants performed 40 min of fatiguing repetitive arm and neck exertions while SEMG data from the upper trapezius and sternocleidomastoid muscles were recorded. The ten of the most commonly used wavelet functions were used to conduct the DWT analysis. Spectral changes estimated using power of wavelet coefficients in the 12–23 Hz frequency band showed the highest sensitivity to fatigue induced by the dynamic repetitive exertions. Although most of the wavelet functions tested in this study reasonably demonstrated the expected power trend with fatigue development and recovery, the overall performance of the “Rbio3.1” wavelet in terms of power estimation and statistical significance was better than the remaining nine wavelets.  相似文献   

11.
《IRBM》2019,40(3):145-156
ObjectiveElectrocardiogram (ECG) is a diagnostic tool for recording electrical activities of the human heart non-invasively. It is detected by electrodes placed on the surface of the skin in a conductive medium. In medical applications, ECG is used by cardiologists to observe heart anomalies (cardiovascular diseases) such as abnormal heart rhythms, heart attacks, effects of drug dosage on subject's heart and knowledge of previous heart attacks. Recorded ECG signal is generally corrupted by various types of noise/distortion such as cardiac (isoelectric interval, prolonged depolarization and atrial flutter) or extra cardiac (respiration, changes in electrode position, muscle contraction and power line noise). These factors hide the useful information and alter the signal characteristic due to low Signal-to-Noise Ratio (SNR). In such situations, any failure to judge the ECG signal correctly may result in a delay in the treatment and harm a subject (patient) health. Therefore, appropriate pre-processing technique is necessary to improve SNR to facilitate better treatment to the subject. Effects of different pre-processing techniques on ECG signal analysis (based on R-peaks detection) are compared using various Figures of Merit (FoM) such as sensitivity (Se), accuracy (Acc) and detection error rate (DER) along with SNR.MethodsIn this research article, a new fractional wavelet transform (FrWT) has been proposed as a pre-processing technique in order to overcome the disadvantages of other existing commonly used techniques viz. wavelet transform (WT) and the fractional Fourier transform (FrFT). The proposed FrWT technique possesses the properties of multiresolution analysis and represents signal in the fractional domain which consists of representation in terms of rotation of signals in the time–frequency plane. In the literature, ECG signal analysis has been improvised using statistical pre-processing techniques such as principal component analysis (PCA), and independent component analysis (ICA). However, both PCA and ICA are prone to suffer from slight alterations in either signal or noise, unless the basis functions are prepared with a worldwide set of ECG. Independent Principal Component Analysis (IPCA) has been used to overcome this shortcoming of PCA and ICA. Therefore, in this paper three techniques viz. FrFT, FrWT and IPCA are selected for comparison in pre-processing of ECG signals.ResultsThe selected methods have been evaluated on the basis of SNR, Se, Acc and DER of the detected ECG beats. FrWT yields the best results among all the methods considered in this paper; 34.37dB output SNR, 99.98% Se, 99.96% Acc, and 0.036% DER. These results indicate the quality of biology-related information retained from the pre-processed ECG signals for identifying different heart abnormalities.ConclusionCorrect analysis of the acquired ECG signal is the main challenge for cardiologist due to involvement of various types of noises (high and low frequency). Twenty two real time ECG records have been evaluated based on various FoM such as SNR, Se, Acc and DER for the proposed FrWT and existing FrFT and IPCA preprocessing techniques. Acquired real-time ECG database in normal and disease situations is used for the purpose. The values of FoMs indicate high SNR and better detection of R-peaks in a ECG signal which is important for the diagnosis of cardiovascular disease. The proposed FrWT outperforms all other techniques and holds both analytical attributes of the actual ECG signal and alterations in the amplitudes of various ECG waveforms adequately. It also provides signal portrayals in the time-fractional-frequency plane with low computational complexity enabling their use practically for versatile applications.  相似文献   

12.
《IRBM》2014,35(6):351-361
Nowadays, doctors use electrocardiogram (ECG) to diagnose heart diseases commonly. However, some nonideal effects are often distributed in ECG. Discrete wavelet transform (DWT) is efficient for nonstationary signal analysis. In this paper, the Symlets sym5 is chosen as the wavelet function to decompose recorded ECG signals for noise removal. Soft-thresholding method is then applied for feature detection. To detect ECG features, R peak of each heart beat is first detected, and the onset and offset of the QRS complex are then detected. Finally, the signal is reconstructed to remove high frequency interferences and applied with adaptive searching window and threshold to detect P and T waves. We use the MIT-BIH arrhythmia database for algorithm verification. For noise reduction, the SNR improvement is achieved at least 10 dB at SNR 5 dB, and most of the improvement SNR are better than other methods at least 1 dB at different SNR. When applying to the real portable ECG device, all R peaks can be detected when patients walk, run, or move at the speed below 9 km/h. The performance of delineation on database shows in our algorithm can achieve high sensitivity in detecting ECG features. The QRS detector attains a sensitivity over 99.94%, while detectors of P and T waves achieve 99.75% and 99.7%, respectively.  相似文献   

13.
Magnetic anomaly detection (MAD) is a passive approach for detection of a ferromagnetic target, and its performance is often limited by external noises. In consideration of one major noise source is the fractal noise (or called 1/f noise) with a power spectral density of 1/fa (0<a<2), which is non-stationary, self-similarity and long-range correlation. Meanwhile the orthonormal wavelet decomposition can play the role of a Karhunen-Loève-type expansion to the 1/f-type signal by its decorrelation abilities, an effective energy detection method based on undecimated discrete wavelet transform (UDWT) is proposed in this paper. Firstly, the foundations of magnetic anomaly detection and UDWT are introduced in brief, while a possible detection system based on giant magneto-impedance (GMI) magnetic sensor is also given out. Then our proposed energy detection based on UDWT is described in detail, and the probabilities of false alarm and detection for given the detection threshold in theory are presented. It is noticeable that no a priori assumptions regarding the ferromagnetic target or the magnetic noise probability are necessary for our method, and different from the discrete wavelet transform (DWT), the UDWT is shift invariant. Finally, some simulations are performed and the results show that the detection performance of our proposed detector is better than that of the conventional energy detector even utilized in the Gaussian white noise, especially when the spectral parameter α is less than 1.0. In addition, a real-world experiment was done to demonstrate the advantages of the proposed method.  相似文献   

14.
In this paper, a novel Wavelet Energy based diagnostic distortion (WEDD) measure is proposed to assess the reconstructed signal quality for ECG compression algorithms. WEDD is evaluated from the Wavelet coefficients of the original and the reconstructed ECG signals. For each ECG segment, a Wavelet energy weight vector is computed via five-level biorthogonal discrete Wavelet transform (DWT). WEDD is defined as the sum of Wavelet energy weighted percentage root mean square difference of each subband. The effectiveness of this measure is validated by linear (linear polynomial and cubic polynomial) and nonlinear (logistic) regression analysis between the computed WEDD values and the mean opinion score (MOS) given by cardiologists. WEDD provides a better prediction accuracy and exhibits a statistically better monotonic relationship with the MOS ratings than Wavelet based weighted percentage root mean square difference (PRD) measure (WWPRD), PRD and other objective measures. Standard correlation coefficient and Spearman rank-order correlation coefficient (SROCC) between the WEDD/MOS ratings is 0.969 and 0.9624, respectively.  相似文献   

15.
基于经验模态分解(EMD)理论,提出一种左右手运动想象脑电信号分析方法。首先利用时间窗对脑电信号数据进行划分,对每段数据通过经验模态分解法将其分解为一组固有模态函数IMF,提取主要信号所在的IMF层去除信号中的噪声。对含有主要信号的几层IMF进行Hilbert变换,得到瞬时频率与对应的瞬时幅值。再提取左右手想象的特定频段mu节律和beta节律的能量信号作为特征,分别利用支持向量机(SVM)和Fisher进行了分类比较。对EMD和小波包在去噪和特征提取进行了比较。结果表明,EMD是一种很有效的去噪方法,经过EMD分解后提取的能量信号在区分左右手想象上更具有优势,识别率高。  相似文献   

16.
《IRBM》2020,41(1):2-17
In this work, computationally efficient and reliable cosine modulated filter banks (CMFBs) are designed for Electrocardiogram (ECG) data compression. First of all, CMFBs (uniform and non-uniform) are designed using interpolated finite impulse response (IFIR) prototype filter to reduce the computational complexity. To reduce the reconstruction error, linear iteration technique is applied to optimize the prototype filter. Then after, non-uniform CMFB is used for ECG data compression by decomposing ECG signal into various frequency bands. Subsequently, thresholding is applied for truncating the insignificant coefficients. The estimation of the threshold value is done by examining the significant energy of each band. Further, Run-length encoding (RLE) is utilized for improving the compression performance. The method is applied to MIT-BIH arrhythmia database for performance analysis of the proposed work. The experimental observations demonstrate that the proposed method has accomplished high compression ratio with the admirable quality of signal reconstruction. The proposed work provides the average values of compression ratio (CR), percent root mean square difference (PRD), percent root mean square difference normalized (PRDN), quality score (QS), correlation coefficient (CC), maximum error (ME), mean square error (MSE), and signal to noise ratio (SNR) are 23.86, 1.405, 2.55, 19.08, 0.999, 0.12, 0.054 and 37.611 dB, respectively. The proposed 8-channel uniform filter bank is used to detect the R-peak locations of the ECG signal. The comparative analysis shows that beats (locations and amplitudes) of both signals (original and reconstructed signals) are same.  相似文献   

17.
Hypothesis/objective: Prolonged QT interval is an index of propensity for dangerous ventricular tachyarrhythmias. The aim of this article is to establish an automatic algorithm for QT interval measurement.

Method: The proposed method is based on the continuous wavelet transform. In this method, the concepts of the rescaled wavelet coefficients and dominant scales of the electrocardiogram (ECG) components are used to perform detection of ECG characteristic points. A new concept of rescaled maximum energy density is introduced so as to perform the estimation of the QT interval.

Results and conclusion: We have applied the algorithm to the PTB database of the Physiobank?Physionet in lead II. Then, the results were evaluated using pertinent reference QT. The criterion used for evaluation of the method's performance is the root mean square (RMS) error. The method approached the RMS error of 27.89 ms for 549 subjects. The proposed method is fast, simple and is applicable to a wide range of ECG cardio cycle morphologies.  相似文献   

18.
《IRBM》2020,41(1):18-22
ObjectivesElectromyography (EMG) is recording of the electrical activity produced by skeletal muscles. The classification of the EMG signals for different physical actions can be useful in restoring some or all of the lost motor functionalities in these individuals. Accuracy in classifying the EMG signal indicates efficient control of prosthesis.Material and methodsThe flexible analytic wavelet transform (FAWT) is used for classification of surface electromyography (sEMG) signals for identification of physical actions. FAWT is an efficient method for decomposition of sEMG signal into eight sub-bands, features namely neg-entropy, mean absolute value (MAV), variance (VAR), modified mean absolute value type 1 (MAV1), waveform length (WL), simple square integral (SSI), Tsallis entropy, integrated EMG (IEMG) are extracted from the sub-bands. Extracted features are fed into an extreme learning machine (ELM) classifier with sigmoid activation function.ResultsComprehensive experiments are conducted on the input sEMG signals and the accuracy, sensitivity and specificity scores are used for performance measurement. Experiments showed that among all sub-bands, the seventh sub-band provided the best performance where the recorded accuracy, sensitivity and specificity values were 99.36%, 99.36% and 99.93%, respectively. The comparison results showed best efficiency of proposed method as compared to other methods on the same dataset.ConclusionThis paper investigates the usage of the FAWT and ELM on sEMG signal classification. The results show that the proposed method is quite efficient in classification of the sEMG signals. It is also observed that the seventh sub-band of the FAWT provides the best discrimination property. In the future works, recent wavelet transform methods will be used for improving the classification performance.  相似文献   

19.
Electrocardiogram (ECG) is the P-QRS-T wave, representing the cardiac function. The information concealed in the ECG signal is useful in detecting the disease afflicting the heart. It is very difficult to identify the subtle changes in the ECG in time and frequency domains. The Discrete Wavelet Transform (DWT) can provide good time and frequency resolutions and is able to decipher the hidden complexities in the ECG. In this study, five types of beat classes of arrhythmia as recommended by Association for Advancement of Medical Instrumentation (AAMI) were analyzed namely: non-ectopic beats, supra-ventricular ectopic beats, ventricular ectopic beats, fusion betas and unclassifiable and paced beats. Three dimensionality reduction algorithms; Principal Component Analysis (PCA), Linear Discriminant Analysis (LDA) and Independent Component Analysis (ICA) were independently applied on DWT sub bands for dimensionality reduction. These dimensionality reduced features were fed to the Support Vector Machine (SVM), neural network (NN) and probabilistic neural network (PNN) classifiers for automated diagnosis. ICA features in combination with PNN with spread value (σ) of 0.03 performed better than the PCA and LDA. It has yielded an average sensitivity, specificity, positive predictive value (PPV) and accuracy of 99.97%, 99.83%, 99.21% and 99.28% respectively using ten-fold cross validation scheme.  相似文献   

20.
本文描述了基于二进制小波变换(DyWT),ECG信号中QRS综合波的检测。设计-小波它适合于QRS检测,将基于心电信号的特殊的特征的特征为小波的尺度。DyWT较之其它方法最基本的优点为强有力的抑制噪声检测以及在分析随时间变化ECG波形时的灵活性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号