首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 703 毫秒
1.
A simple, rapid and sensitive high-performance liquid chromatography (HPLC) method was developed for the enantioselective analysis of the new antidepressant drug mirtazapine in human plasma. The procedure involved liquid-liquid extraction using toluene, followed by liquid chromatography coupled to UV detection at 292 nm. The chromatographic separation of the (+)-(S)- and (-)-(R)-enantiomers of mirtazapine was achieved on a Chiralpak AD column (250 mm x 4.6 mm, 10 microm particle size) protected with a CN guard column, using hexane-ethanol (98:2, v/v) plus 0.1% diethylamine as the isocratic mobile phase, at a flow rate of 1.2 ml/min. The total analysis time was less than 12 min per sample. The recoveries of (+)-(S)- and (-)-(R)-mirtazapine were in the 88-111% range with a linear response over the 6.25-625 ng/ml concentration range for both enantiomers. The quantification limit (LOQ) was 5 ng/ml. Within-day and between-day assay precision and accuracy were studied at three concentration levels (10, 50 and 250 ng/ml). For both mirtazapine enantiomers, the coefficients of variation (CV) and deviation from the theoretical value were lower than 15% at all concentration levels. The method proved to be suitable for pharmacokinetic studies.  相似文献   

2.
A modified method for the determination of gacyclidine enantiomers in human plasma by GC–MS with selected-ion monitoring using the deuterated derivative of gacyclidine (d3-gacyclidine) as internal standard was developed. Following a single-step liquid–liquid extraction with hexane, drug enantiomers were separated on a chiral fused-silica capillary column (CP-Chirasil-Dex; Chrompack). The fragment ion, m/z 266, was selected for monitoring d3-gacyclidine (retention times of 35.2 and 35.6 min for the (+)- and (−)-enantiomer, respectively) whereas the fragment ion, m/z 263, was selected for quantitation of gacyclidine (retention times of 35.4 and 35.9 min for the (+)- and (−)-enantiomer, respectively). The limit of quantitation for each enantiomer was 0.3 ng/ml, using 1 ml of sample, with a relative standard deviation (RSD) <14% and a signal-to-noise ratio of 5. The extraction recovery of both gacyclidine enantiomers from human plasma was about 75%. The calibration curves were linear (r2>0.996) over the working range of 0.312 to 20 ng/ml. Within- and between-day RSD were <9% at 5, 10 and 20 ng/ml, and <16% at 0.312, 0.625, 1.25 and 2.5 ng/ml. Intraday and interday bias were less than 11% for both enantiomers. The chromatographic behavior of d3-gacyclidine remained satisfactory even after more than 500 injections. Applicability of this specific and stereoselective assay is demonstrated for a clinical pharmacokinetic study with racemic gacyclidine.  相似文献   

3.
A validated HPLC method for the simultaneous quantitative analysis of the antidepressant mirtazapine and its demethyl metabolite in human plasma is described. The active constituents including internal standard were extracted from 1 ml of plasma with hexane and separated on a μBondapak Phenyl column with fluorescence detection. The lower limit of quantification was 0.5 ng/ml, without significant interferences with endogenous or exogenous components. Inter- and intra-assay accuracy determined at quality control levels of 2, 10 and 80 ng/ml were, respectively, 104.6–113.7% and 105.1–117.7% for mirtazapine, and 91.7–99.3% and 89.9–103.7% for demethylmirtazapine. In all cases the precision was below 6.8%.  相似文献   

4.
We have developed a simple, sensitive, specific and reproducible stereoselective high-performance liquid chromatography technique for analytical separation of cisapride enantiomers and measurement of cisapride enantiomers in human plasma. A chiral analytical column (ChiralCel OJ) was used with a mobile phase consisting of ethanol–hexane–diethylamine (35:64.5:0.5, v/v/v). This assay method was linear over a range of concentrations (5–125 ng/ml) of each enantiomer. The limit of quantification was 5 ng/ml in human plasma for both cisapride enantiomers, while the limit of detection was 1 ng/ml. Intra- and inter-day C.V.s did not exceed 15% for all concentrations except at 12.5 ng/ml for EII (+)-cisapride, which was 20 and 19%, respectively. The clinical utility of the method was demonstrated in a pharmacokinetic study of normal volunteers who received a 20 mg single oral dose of racemic cisapride. The preliminary pharmacokinetic data obtained using the method we describe here provide evidence for the first time that cisapride exhibits stereoselective disposition.  相似文献   

5.
A sensitive gas chromatographic assay using mass selective-detection has been developed for the simultaneous quantitation of the enantiomers of (±)-gacyclidine (a non competitive N-methyl-

-aspartate antagonist) in human plasma. Gacyclidine enantiomers and phencyclidine (PCP), the internal standard, were extracted using a single-step liquid–liquid extraction with hexane at pH 8.0. Each enantiomer was separated on a chiral gas chromatography capillary column and specifically detected by mass spectrometry (MS) in selected-ion monitoring (SIM) mode. Gacyclidine enantiomers and PCP were monitored using the fragment ions at m/z 206 and 200, respectively. No interference was observed from endogenous components. The limit of quantitation (LOQ) for each enantiomer of gacyclidine was 300 pg/ml by using plasma samples of 500 μl. The calibration curves were linear (r2=0.998) over a range of 0.3125 to 20 ng/ml. The extraction efficiency was higher than 95% for both enantiomers. Intra- and inter-day bias were less than 10% at every standard curve concentration. Intra-day precision was less than 19% for (−)-gacyclidine and 15% for (+)-gacyclidine. Inter-day precision was below 15% for both enantiomers. The assay was validated for an enantioselective pharmacokinetic study in healthy male volunteers.  相似文献   

6.
A sensitive and stereoselective high-performance liquid chromatographic assay for the determination of the enantiomers of metoprolol (R- and S-) and the diastereoisomers of α-hydroxymetoprolol (IIA, IIB) in plasma is reported. Chromatography involved direct separation of enantiomers using a Chirobiotic T bonded phase column (250×4.6 mm) and a mobile phase consisting of acetonitrile–methanol–methylene chloride–glacial acetic acid–triethylamine (56:30:14:2:2, v/v). Solid-phase extraction using silica bonded with ethyl group (C2) was used to extract the compounds of interest from plasma and atenolol was used as the internal standard. The column effluent was monitored using fluorescence detection with excitation and emission wavelengths of 225 and 310 nm, respectively. S-Metoprolol,R-metoprolol, IIB and IIA eluted at about 5.9, 6.7, 7.3 and 8.2 min without any interfering peaks. The calibration curve was linear over the range of 0.5 to 100 ng/ml for each isomer of metoprolol and 1 to 100 ng/ml for each isomer of α-hydroxymetoprolol (IIA & IIB). The mean intra-run accuracies were in the range of 96.2 to 114% for R-metoprolol, 94.0 to 111% for S-metoprolol, 90.2 to 110% for IIA, and 94.6 to 106% for IIB. The mean intra-run precisions were all in the range of 2.2 to 12.0% for R-metoprolol, 2.1 to 11.1% for S-metoprolol, 1.9 to 14.5% for IIA, and 3.2 to 11.0% for IIB. The lowest level of quantitation for the enantiomers of metoprolol was 0.5 ng/ml and 1.0 ng/ml for α-hydroxymetoprolol (IIA and IIB). The absolute recoveries for each analyte was ≥95%. The validated method accurately quantitated the enantiomers of parent drug and metabolite after a single dose of an extended release metoprolol formulation.  相似文献   

7.
A sensitive and stereospecific HPLC method was developed for the analysis of (−)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-β-cyclodextrin (S-β-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)–absolute ethanol (80:20, v/v) containing 10 mM S-β-CD at a flow-rate of 0.7 ml/min. Recoveries of (−)- and (+)-pentazocine were in the range of 91–93%. Linear calibration curves were obtained in the 20–400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9–7.0% and 1.2–6.2%, respectively, for the (−)-enantiomer and 0.8– 7.6% and 1.2–4.6%, respectively, for the (+)-enantiomer (n=3).  相似文献   

8.
A sensitive, stereoselective high-performance liquid chromatographic method with fluorescence detection for the measurement of bisoprolol enantiomers in human plasma and urine has been developed. Bisoprolol was extracted at alkaline pH with chloroform, followed by solid-phase extraction. The effluent was evaporated, and the reconstituted residue was chromatographed on a Chiralcel OD column with a mobile phase of hexane—2-propanol (10:0.9, v/v) containing 0.01% (v/v) diethylamine. Within the plasma and urine enantiomeric concentration ranges of 5–100 ng/ml and 25–1250 ng/ml, respectively, a linear relationship was obtained between the peak-height ratios and the corresponding concentrations. The limit of quantitation, defined as three times the baseline noise, was 2 ng/ml for each enantiomer in plasma. A preliminary pharmacokinetic study was undertaken in three healthy male volunteers following an oral dose of 5 mg of racemic bisoprolol. The results confirm that this assay is suitable for pharmacokinetic studies of bisoprolol enantiomers in humans following oral administration of the therapeutic dose.  相似文献   

9.
A sensitive capillary electrophoretic method for the determination of carvedilol enantiomers in 100 μl of human plasma has been developed and validated. Carvedilol and the internal standard carazolol are isolated from plasma samples by liquid–liquid extraction using diethylether. A sensitive and selective detection is provided by helium–cadmium laser-induced fluorescence. The total analysis time is 17.5 min, about 30 min are needed for the sample preparation. The linearity of the assay ranges from 1.56 to 50 ng/ml per carvedilol enantiomer. The limits of quantification (LOQ) for the carvedilol enantiomers in 100 μl of human plasma are 1.56 ng/ml. The inter-day accuracy for R-carvedilol is between 95.8 and 103% (104% at LOQ) and for S-carvedilol between 97.1 and 103% (107% at LOQ); the inter-day precision values are between 3.81 and 8.64% (10.9% at LOQ) and between 5.47 and 7.86% (7.91% at LOQ) for R- and S-carvedilol, respectively. The small sample volume needed is especially advantageous for the application in clinical studies in pediatric patients. As an application of the assay concentration/time profiles of the carvedilol enantiomers in a 5-year-old patient receiving a test dose of 0.09 mg/kg carvedilol are reported.  相似文献   

10.
A valid, sensitive high-performance liquid chromatographic technique is reported for the separation of the two enantiomers of metoprolol in human plasma. The procedure involves pre-column derivatization with the homochiral reagent S-(+)-1-(1-naphthyl)-ethyl isocyanate. Once formed, the diastereomers are separated using normal-phase high-performance liquid chromatography. Fluorescence detection (220 nm excitation; no emission filter) was utilized, resulting in baseline resolution (Rs > 1.5). The peaks corresponding to metoprolol enantiomers were free from interference throughout the examined range of 5–500 ng/ml; accuracy and precision were within approximately 10%. Analysis of a plasma sample collected from a healthy volunteer demonstrated that the assay is applicable to clinical studies.  相似文献   

11.
CPT-11 {I; 7-ethyl-10-[4-(1-piperidino)-1-piperidino]carbonyloxycamptothecin} is a new anticancer agent currently under clinical development. A sensitive high-performance liquid chromatographic assay suitable for the simultaneous determination of I and its active metabolite SN-38 (II) in human plasma, and their preliminary clinical pharmacokinetics, are described. Plasma samples were processed using a solid-phase (C18) extraction step allowing mean recoveries of I, II and the internal standard camptothecin (III) of 84, 99 and 72%, respectively. The extracts were chromatographed on a C18 reversed-phase column with a mobile phase composed of acetonitrile, phosphate buffer and heptanesulphonic acid, with fluorescence detection. The calibration graphs were linear over a wide range of concentrations (1 ng/ml–10 μg/ml), and the lower limit of determination was 1 ng/ml for both I and II. The method showed good precision: the within-day relative standard deviation (R.S.D.) (5–1000 ng/ml) was 13.0% (range 4.9–19.4%) for I and 12.8% (6.7–19.1%) for II; the between-day R.S.D. (5–10 000 ng/ml was 7.9% (5.4–17.5%) for I and 9.7% (3.5–15.1%) for II. Using this assay, plasma pharmacokinetics of both I and II were simultaneously determined in three patients receiving 100 mg/m2 I as a 30-min intravenous infusion. The mean peak plasma concentration of I at the end of the intravenous infusion was 2400 ± 285 ng/ml (mean ± standard error of the mean). Plasma decay was triphasic with half-lives α, β and γ of 5.4 ± 1.8 min, 2.5 ± 0.5 h and 20.2 ± 4.6 h, respectively. The volume of distribution at steady state was 105 ± 15 l/m2, and the total body clearance was 12.5 ± 1.9 l/h · m2. The maximum concentrations of the active metabolite II reached 36 ± 11 ng/ml.  相似文献   

12.
A sensitive method for the enantioselective high-performance liquid chromatography (HPLC) determination of nicardipine in human plasma is described. (+)-Nicardipine, (−)-nicardipine and (+)-barnidipine as an internal standard are detected by an ultraviolet detector at 254 nm. Racemic nicardipine in human plasma was extracted by a rapid and simple procedure based on C18 bonded-phase extraction. The extraction samples were purified and concentrated on a pre-column using a C1 stationary phase and the enantiomers of nicardipine are quantitatively separated by HPLC on a Sumichiral OA-4500 column, containing a chemically modified Pirkle-type stationary phase. Determination of (+)- and (−)-nicardipine was possible in a concentration range of 5–100 ng ml−1 and the limit of detection in plasma was 2.5 ng ml−1. The recoveries of (+)- and (−)-nicardipine added to plasma were 91.4–98.4% and 93.3–96.7%, respectively, with coefficients of variation of less than 9.0 and 9.4% respectively. The method was applied to low level monitoring of (+)- and (−)-nicardipine in plasma from healthy volunteers.  相似文献   

13.
In order to determine epirubicin and its metabolites at low concentrations (<38 ng/ml) in small plasma samples, a fast reliable method based on a precipitation pre-treatment and sensitive reversed-phase isocratic HPLC has been developed and validated for epirubicin in the range 5–100 ng/ml. The R.S.D. was 5–9% over this concentration range. For human serum containing 25 ng/ml of epirubicin, the inter- and intra-day variation was <10%. Recoveries of the metabolites epirubicinol, 7-deoxydoxorubicinone and 7-deoxydoxorubicinolone at 20 ng/ml ranged from 94–104%. The assay has been used to study human plasma samples taken during a 96-h infusion of epirubicin in a patient with multiple myeloma. The combined levels of the unseparated metabolites, epirubicin glucuronide and epirubicinol glucuronide, were semiquantitatively determined after treatment with β-glucuronidase. The metabolites epirubicinol and 7-deoxydoxorubicinolone, but not 7-deoxydoxorubicinone, were also detected and measured.  相似文献   

14.
A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate–acetic acid–ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate–acetic acid–ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile–methanol–ethanol–2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5–2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4–96.5% for retinol (range 100–1000 ng/ml) and 92.7–96.0% for retinyl palmitate (range 5–1000 ng/ml). Inter-assay precision was ≤5.1% and ≤6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data.  相似文献   

15.
A sensitive and selective high-performance liquid chromatographic (HPLC) method has been developed for the simultaneous determination of bufuralol enantiomers in plasma and pharmaceutical formulations. Enantiomeric resolution was achieved on a vancomycin macrocyclic antibiotic chiral stationary phase (CSP) known as Chirobiotic V with UV detection set at 254 nm. The polar ionic mobile phase (PIM) consisting of methanol-glacial acetic acid-triethylamine (100:0.015:0.010, v/v/v) has been used at a flow rate of 0.5 ml/min. The method is highly specific where other coformulated compounds did not interfere. The stability of bufuralol enantiomers under different degrees of temperature was also studied. The results showed that the drug is stable for at least 7 days at 70 degrees C. The method was validated for its linearity, accuracy, precision and robustness. An experimental design was used during validation to evaluate method robustness. The calibration curves in plasma were linear over the range of 5-500 ng/ml for each enantiomer with detection limit of 2 ng/ml. The mean relative standard deviation (RSD) of the results of within-day precision and accuracy of the drug were 0.05) between inter- and intra-day studies for each enantiomer which confirmed the reproducibility of the assay method. The mean extraction efficiency for S-(-)- and R-(+)-bufuralol from plasma was in the range 97-102% at 15-400 ng/ml level for each enantiomer. The overall recoveries of bufuralol enantiomers from pharmaceutical formulations was in the range 99.6-102.2% with %RSD ranging from 1.06 to 1.16%. The assay method proved to be suitable as chiral quality control for bufuralol formulations by HPLC and for therapeutic drug monitoring.  相似文献   

16.
A highly sensitive and selective liquid chromatography–atmospheric pressure chemical ionization tandem mass spectrometry assay was developed and validated for simultaneous determination of epimeric budesonide (BUD) and fluticasone propionate (FP) in plasma. The drugs were isolated from human plasma using C18 solid-phase extraction cartridges, and epimeric BUD was acetylated with a mixture of 12.5% acetic anhydride and 12.5% triethylamine in acetonitrile to form the 21-acetyl derivatives following the solid-phase extraction. Deuterium-labelled BUD acetate with an isotopic purity >99% was synthesized and used as the internal standard. The assay was linear over the ranges 0.05–10.0 ng/ml for epimeric BUD, and 0.02–4.0 ng/ml for FP. The inter- and intra-day relative standard deviations were <14.3% in the assay concentration range.  相似文献   

17.
A sensitive high-performance liquid chromatographic assay has been developed and validated for the determination of methyl N-[5-[[4-(2-pyridinyl)-1-piperazinyl]carbonyl]-1H-benzimidazol-2-yl] carbamate (CDRI compound 81/470) in normal rat blood. The method described herein is simple, with improved selectivity and sensitivity over a previously reported HPLC method. The limit of quantitation is 10 ng/ml (method 1) and 2.5 ng/ml (method 2) in blood, as compared with 40 ng/ml for the previous method. The standard curve in blood is linear over the concentration range 10–1000 ng/ml in method 1 and 2.5–1000 ng/ml in method 2 and the extraction recovery is higher than 80% for both methods.  相似文献   

18.
A sensitive and specific high-performance liquid chromatographic method with fluorescence detection (excitation wavelength: 280 nm; emission wavelength: 360 nm) was developed and validated for the determination of vinorelbine in plasma and blood samples. The sample pretreatment procedure involved two liquid–liquid extraction steps. Vinblastine served as the internal standard. The system uses a Spherisorb cyano analytical column (250×4.6 mm I.D.) packed with 5 μm diameter particles as the stationary phase and a mobile phase of acetonitrile–80 mM ammonium acetate (50:50, v/v) adjusted to pH 2.5 with hydrochloric acid. The assay showed linearity from 1 to 100 ng/ml in plasma and from 2.5 to 100 ng/ml in blood. The limits of quantitation were 1 ng/ml and 2.5 ng/ml, respectively. Precision expressed as RSD was in the range 3.9 to 20% (limit of quantitation). Accuracy ranged from 92 to 120%. Extraction recoveries from plasma and blood averaged 101 and 75%, respectively. This method was used to follow the time course of the concentration of vinorelbine in human plasma and blood samples after a 10-min infusion period of 20 mg/m2 of this drug in patients with metastatic cancer.  相似文献   

19.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of albendazole sulfoxide (ABZSO) enantiomers and albendazole sulfone (ABZSO2) in human plasma. The resolution of ABZSO enantiomers and ABZSO2 was obtained on a Chiralpak® AD column using hexane–isopropanol–ethanol (81:14.25:4.75, v/v/v) as the mobile phase. The drugs were detected by fluorescence (λexc=280 nm, λem=320 nm). The drugs were extracted from 500 μl plasma with ethyl acetate, and after solvent evaporation, the residues were dissolved in the mobile phase and chromatographed. The method was precise and accurate for the three compounds, as judged by the coefficients of variation and relative errors observed. Linear standard curves were obtained in the concentration range of 5–2500 ng/ml for ABZSO enantiomers and 1–500 ng/ml for ABZSO2. A typical plasma concentration–time profile is presented for one patient under treatment for neurocysticercosis.  相似文献   

20.
A simple and highly sensitive high-performance liquid chromatography (HPLC) method for the simultaneous quantitative determination of lansoprazole enantiomers and their metabolites, 5-hydroxylansoprazole enantiomers and lansoprazole sulfone, in human plasma have been developed. Chromatographic separation was achieved with a Chiral CD-Ph column using a mobile phase of 0.5M NaClO(4)-acetonitrile-methanol (6:3:1 (v/v/v)). The analysis required only 100 microl of plasma and involved a solid-phase extraction with Oasis HLB cartridge, with a high extraction recovery (>94.1%) and good selectivity. The lower limit of quantification (LOQ) of this assay was 10 ng/ml for each enantiomer of both lansoprazole and 5-hydroxylansoprazole, and 5 ng/ml for lansoprazole sulfone. The coefficient of variation of inter- and intra-day assay was <8.0% and accuracy was within 8.4% for all analytes (concentration range 10-1000 ng/ml). The linearity of this assay was set between 10 and 1000 ng/ml (r2>0.999 of the regression line) for each of the five analytes. This method is applicable for accurate and simultaneous monitoring of the plasma levels of lansoprazole enantiomers and their metabolites in the renal transplant recipients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号